• 제목/요약/키워드: Coil Design

검색결과 998건 처리시간 0.023초

Magnetic Particle Separation by an Optimized Coil: A Graphical User Interface

  • Rouhi, Kasra;Hajiaghajani, Amirhossein;Abdolali, Ali
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.214-219
    • /
    • 2017
  • Magnetic separators that clean the fluid stream from impurities, protect the installations in numerous industries. This paper introduces a graphical user interface (GUI) which proposes an optimized coil separating magnetic particles with a radius from 1 up to 500 µm. High gradient magnetic fields are employed in an arbitrary user defined fluidic channel which is made of a nonmetallic material. The effects of coil parameters are studied and adjusted to design an optimum coil with a minimum Ohmic loss. In addition, to design the coil scheme based on the particle movements, a mathematical particle-tracing model within the fluid channels has been utilized. In comparison to conventional magnetic separators, this model is reconfigurable by the user, produces a weaker magnetic field, allows for continuous purifying and is easy to install, with high separation efficiency. The presented GUI is simple to use, where the coil's manufacturing limitations can be specified.

5 T급 고온초전도마그넷의 설계 및 제작 (Design and Fabrication of 5 T HTS Insert Magnet)

  • 구명환;김동락;최연석;차귀수
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.28-32
    • /
    • 2012
  • The critical current of the HTS(High Temperature Superconductor) tape is governed by cooling temperature, magnetic field and its angle to HTS tape originated from its geometrical structure. At the HTS coil design stage, the critical current of the coil is calculated by considering the Ic-B characteristics of the 2G tape and the operating current is determined based on the critical current. The operating current and the structure of the 5 T coil are suggested through the FEM (Finite Elements Method) analysis and calculation. As a part of our on-going research on a 20 T LTS/HTS magnet, we have designed and constructed a 5 T HTS insert coil and tested it in liquid helium temperature.

One Coil을 이용한 VCB의 PMA 설계 (Design of Permanent Magnetic Actuator for VCB with One Coil)

  • 김진철;김지호;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.878-880
    • /
    • 2004
  • In this paper, a new design of permanent magnetic actuator (PMA) for vacuum circuit breaker (VCB) with one coil is proposed. Electromagnetic characteristic analysis is performed numerically using finite element method (FEM) considering the nonlinearity of magnetic core and permanent magnet. The characteristics of proposed PMA with one coil is similar with that of the conventional PMA with two coils. The proposed PMA can simplify the control circuit because of the usage of one coil. Therefore, the reliability of VCB can be improved with the proposed model.

  • PDF

Double-Loop Coil Design for Wireless Power Transfer to Embedded Sensors on Spindles

  • Chen, Suiyu;Yang, Yongmin;Luo, Yanting
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.602-611
    • /
    • 2019
  • The major drawbacks of magnetic resonant coupled wireless power transfer (WPT) to the embedded sensors on spindles are transmission instability and low efficiency of the transmission. This paper proposes a novel double-loop coil design for wirelessly charging embedded sensors. Theoretical and finite-element analyses show that the proposed coil has good transmission performance. In addition, the power transmission capability of the double-loop coil can be improved by reducing the radius difference and width difference of the transmitter and receiver. It has been demonstrated by analysis and practical experiments that a magnetic resonant coupled WPT system using the double-loop coil can provide a stable and efficient power transmission to embedded sensors.

Minimum-Inductance MRI Gradient Coil Design with Arbitrarily-Selected Shape (자기공명 영상촬영을 위한 임의로 선택된 모양의 최소인덕턴스 경사자계코일의 설계)

  • 이종권;양윤정;이윤;조장희;오창현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 춘계학술대회
    • /
    • pp.85-87
    • /
    • 1994
  • This paper proposes a new inductance minimization scheme for a gradient system of arbitrarily selected shape. Although it is important to minimize the gradient coil inductance to reduce the current switching time, such minimization has been possible only for cylindrical or parallel biplanar coils. By using small current loops on arbitrarily selected surface as optimization elements, the inductance of the whole circuit can be minimized using the loop's self- and mutual-inductances. Wire positions can be easily derived from the loop current distribution. Preliminary studies for the design of x-directional surface gradient coil show the utility of tile proposed gradient coil design scheme.

  • PDF

반용융 알루미늄 합금의 재가열 및 Thixoforging 부품의 기계적 성질 (Reheating of Semi-Solid Aluminum Alloys and Mechanical Properties of Thixoforged Product)

  • 정홍규;강충길
    • 소성∙가공
    • /
    • 제8권5호
    • /
    • pp.437-448
    • /
    • 1999
  • The reheating of the billet in the semi-solid state as quickly and homogeneously as possible is one of the most imposrtant parts. To obtain a fine globular microstructure in cross section of billet, the optimal design of the induction coil for variation of alloys and specimen sizes is necessary. For the thixo-forging process the construction of the reheating data base is very important, because the reheating conditions are different for variation of SSM and billet sizes. So in this study, the optimal coil design of A356 (ALTHIX) and Aι2024 with d×ι=60×90 (mm) to obtain the globular microstructure is theoretically proposed. The suitability of an optimal coil design will be demonstrated by reheating experiments. Finally, the thixoformability of an arbitrarily shaped product is evaluated by its forming variables. The defects and mechanical properties are also investigated.

  • PDF

설계 민감도법을 이용한 유도 전기장 분포 제어를 위한 철심구조 최적화 연구 (Optimization of Iron Core Structure for Controlling Induced Electric Field Distribution Using the Continuum Design Sensitivity Analysis (CDSA))

  • 박준구
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권8호
    • /
    • pp.397-400
    • /
    • 2006
  • An optimized iron core structure of stimulating coil are presented in order to control the induced electric field distribution using the Continuum Design Sensitivity Analysis (CDSA) combined with a commercially available generalized finite element code (OPERA). The results show that a Figure-Of-Eight (FOE) coil as well as a circular coil with the proposed iron core structure can increase induced electric field intensity by more than two times and make better field localization, compared with those of existing stimulation coil with a air core. After considering manufacturing constraints, a practical iron core structure based on the proposed optimized one is proposed and its performance is analyzed.

모터 고정자 코일 권선기의 동특성 개선 연구 (A Study on the Improvement of Dynamic Characteristics of the Motor Stator Coil Winding Machine)

  • 김동성;김광영;함상용;손영수
    • 대한기계학회논문집A
    • /
    • 제27권9호
    • /
    • pp.1589-1596
    • /
    • 2003
  • In this paper, we performed the improvement study for the dynamic characteristics enhancement of the motor stator coil vertical winding machine. The dynamic characteristics improvement was done by means of the optimized design and the weight reduction of the flyer configuration, modified design of the servo control system for the flyer and the former actuation, and the development of jump timing digital circuit for the reduction of former jumping error. As the results, the maximum winding speed pattern of the developed machine was attained up to 3000rpm and also reduced the jumping error. In conclusion, domestic design technology for manufacturing the motor coil vertical winding machine was established through this study.

자기공명영상촬영을 위한 표면경사자계코일의 저전력 설계 (Low-Power Design of the Surface Gradient Coil for Magnetic Resonance Imaging)

  • 오창현;이종권;이윤;김민기
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.33-35
    • /
    • 1993
  • A new low-power, high-order optimization scheme to design surface gradient coils (SGC) is proposed for magnetic resonance imaging (MRI). Although previous SGCs have been designed and constructed just to get strong linear gradients, this paper proposes more systematic ways of SGC design by minimizing electrical power consumption in the gradient coil and by removing unnecessary high-order field distortions in the imaging region. By assuming continuous current flow on the coil surface which may be or may not be planar, power consumption in the coil is minimized. According to the simulation results, the SGC designed by using the proposed scheme seems to produce much more uniform linear gradient field using less electrical power compared to the previously proposed SGCs.

  • PDF

자기공명영상 촬영 장치에서 다채널 RF Coil에 이용되는 기본 구조 RF Coil의 B1 Field 분석 (Basic RF Coils Used in Multi-channel RF Coil and Its B1 Field Distribution for Magnetic Resonance Imaging System)

  • 김용권
    • 한국산학기술학회논문지
    • /
    • 제11권12호
    • /
    • pp.4891-4895
    • /
    • 2010
  • 본 자기공명영상장치(MRI: Magnetic Resonance Imaging)의 구성 요소인 RF Coil의 성능은 영상의 신호대 잡음비(Signal to Noise Ratio)를 결정하는 장치이다. RF Coil의 성능은 민감도(Sensitivity)와 라디오주파수 필드 균질성(RF Field Uniformity)으로 나타내고, RF Coil에 의해 유기되는 라디오 주파수 자기장(B1 Field)의 세기는 RF Coil의 구조 및 배열에 따라 공간적으로 달라진다. MRI 신호의 크기는 RF Coil이 만들어내는 자기장의 세기에 의해 결정되기 때문에 RF Coil에 의해 형성되는 공간상의 B1 Field의 분포를 확인할 수 있어야 한다. 본 논문에서는 다채널 RF Coil 설계에 있어서 가장 기본이 되는 형태의 RF Coil 구조와 이의 B1 Field 분포를 Matlab을 이용하여 모의실험을 통해 확인 하였다. Matlab을 이용하여 계산된 기본 구조의 RF 코일이 형성하는 B1 Field 분포는 다채널 RF 코일 설계시 매우 유용하게 사용될 수 있을 것이다.