• Title/Summary/Keyword: Coherent sources

Search Result 61, Processing Time 0.029 seconds

Status and Prospect of Free Electron Lasers (자유전자레이저의 개발현황과 전망)

  • Lee, Byung-Cheol;Jeong, Young-Ug;Park, Seong-Hee;Hahn, Sang-June
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.5
    • /
    • pp.435-450
    • /
    • 2006
  • Free electron lasers (FELs) are promising sources of coherent radiation that can provide users with radiations having a wide-range frequency-tunability and good spectral characteristics for basic science and industrial applications. Especially in Terahertz or X-ray ranges of spectrum, FELs can generate much stronger radiations than conventional light sources. In this paper, we introduce the working principles and key technologies of FELs, the status and the prospects of FEL developments.

Localization of coherent/incoherent sources-simulation and experiment (독립/비독립 음원의 위치 탐지 방법)

  • 김시문;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.86-91
    • /
    • 1995
  • 음원의 위치를 찾는 문제에 있어서 비독립 음원들이 존재하는 경우, 근접장에서는 음원으로부터 나오는 파형을 평면파로 가정할 수 없고 구면파로 가정해야 하며, 여러개의 비독립 음원이 존재한다고 가정하여 각각의 음원의 위치를 변화시켜 가면서 MUSIC파워를 계산하여야 한다. 실제 음원의 갯수보다 가정한 음원의 갯수가 작으면 정확한 음원의 위치를 가르키지 못하며 MUSIC 파워 값도 작다. 실제 음원의 갯수와 가정한 음원의 갯수가 같으면 정확한 음원의 위치를 가르치며 MUSIC 파워 값이 크게 얻어진다. 실제 음원의 갯수보다 가정한 음원의 갯수가 큰 경우 실제의 음원의 위치를 포함하여 다른 음원의 위치를 얻을 수 있으나 그 음원의 세기는 무시할 정도로 작다. 즉 실제 음원의 갯수보다 많은 수의 음원을 가정하여 음원을 탐지할 수 있다. 일반 음장 즉 독립 음원과 비독립 음원이 공존하는 경우 실제의 음원의 갯수만큼 가정한다면 음원이 위치를 찾을 수 있다.

  • PDF

Transfer Path Analysis and Estimation of the Road Noise for the Driving Vehicle (주행 차량의 로드 노이즈 예측을 위한 각 입력원의 기여도 평가)

  • Yang, In-Hyung;Jeong, Jae-Eun;Yoon, Ji-Hyun;Oh, Jae-Eung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.11
    • /
    • pp.1071-1077
    • /
    • 2010
  • The reduction of the vehicle interior noise has been the main interest of noise and vibration harshness(NVH) engineers. A passenger vehicle has various and complicated transmission paths of sound and vibration. In order to identify the mechanism of transfer path, estimation of excitation force and exact modeling of transfer path are required. This paper presents method for estimating the noise source contribution on the road noise of the vehicle in a multiple input system where the input sources may be coherent with each other. And vector synthesis technique is employed to identify the characteristics of road noise and its transmission to vehicle compartment through noise and vibration analysis. Vibration reduction efficiency of each transfer path is evaluated by comparing individual vector components obtained virtual simulation.

The Identification of Vibration Sources in Optical Disk Drive Using PCF Method (PCF 기법을 이용한 광디스크 드라이브의 진동원 규명)

  • 함경훈;장영배;박노철;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.127-133
    • /
    • 2002
  • After the vibration source is searched in optical disk drive as an information storage device broadly used the influence of it against FES(Focusing Error Signal) which is a kind of positioning error of pick up from the circuit is carefully examined. For that Purpose, partial coherence function method is applied on a simple multi-degree of freedom model made for the theoretical verification and it is practically introduced in optical disk drive for analyzing the effect of vibration source. Finally, partial coherence output spectrum is attentively observed in order to know which vibration source is a great influence on FES.

  • PDF

Detection of Human Vital Signs and Estimation of Direction of Arrival Using Multiple Doppler Radars

  • An, Yong-Jun;Jang, Byung-Jun;Yook, Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.250-255
    • /
    • 2010
  • This paper presents a non-contact measurement method of vital signal by the use of multiple-input multiple-output (MIMO) bio-radar system, configured with two antennas that are separated by a certain distance. The direction of arrival (DOA) estimation algorithm for coherent sources was applied to detect vital signals coming from different spatial angles. The proposed MIMO bio-radar system was composed of two identical transceivers sharing single VCO with a PLL. In order to verify the performance of the system, the DOA estimation experiment was completed with respect to the human target at angles varying between $-50^{\circ}$ and $50^{\circ}$ where the bio-radar system was placed at distances (corresponding to 50 cm and 95 cm) in front of a human target. The proposed MIMO bio-radar system can successfully find the direction of a human target.

Surface Emitting Terahertz Transistor Based on Charge Plasma Oscillation

  • Kumar, Mirgender;Park, Si-Hyun
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.544-550
    • /
    • 2017
  • This simulation based study reports a novel tunable, compact, room temperature terahertz (THz) transistor source, operated on the concept of charge plasma oscillation with the capability of radiating within a terahertz gap. A vertical cavity with a quasi-periodic distributed-Bragg-reflector has been attached to a THz plasma wave transistor to achieve a monochromatic coherent surface emission for single as well as multi-color operation. The resonance frequency has been tuned from 0.5 to 1.5 THz with the variable quality factor of the optical cavity from 5 to 290 and slope efficiency maximized to 11. The proposed surface emitting terahertz transistor is able to satisfy the demand for compact solid state terahertz sources in the field of teratronics. The proposed device can be integrated with Si CMOS technology and has opened the way towards the development of silicon photonics.

On the Source Identification by Using the Sound Intensity Technique in the Radiated Acoustic Field from Complicated Vibro-acoustic Sources (음향 인텐시티 기법을 이용한 복잡한 진동-음향계의 방사 음장에 대한 음원 탐색에 관하여)

  • 강승천;이정권
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.8
    • /
    • pp.708-718
    • /
    • 2002
  • In this paper, the problems in identifying the noise sources by using the sound intensity technique are dealt with for the general radiated near-field from vibro-acoustic sources. For this purpose, a three-dimensional model structure resembling the engine room of a car or heavy equipment is considered. Similar to the practical situations, the model contains many mutually coherent and incoherent noise sources distributed on the complicated surfaces. The sources are located on the narrow, connected, reflecting planes constructed with rigid boxes, of which a small clearance exists between the whole box structure and the reflecting bottom. The acoustic boundary element method is employed to calculate the acoustic intensity at the near-field surfaces and interior spaces. The effects of relative source phases, frequencies, and locations are investigated, from which the results are illustrated by the contour map, vector plot, and energy streamlines. It is clearly observed that the application of sound intensity technique to the reactive or reverberant field, e.g., scanning over the upper engine room as is usually practiced, can yield the detection of fake sources. For the precise result for such a field, the field reactivity should be checked a priori and the proper effort should be directed to reduce or improve the reactivity of sound field.

A Cost-effective Light Emitting Diode-acoustic System for Preclinical Ocular Applications

  • Choi, Hojong;Ryu, Jaemyung;Yeom, Jung-Yeol
    • Current Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.59-68
    • /
    • 2018
  • Opto-acoustic systems provide structural and functional information regarding biological tissues. Conventional opto-acoustic systems typically employ continuous or pulsed lasers as transmission sources. Compared to lasers, light emitting diodes (LEDs) are cost-effective and relatively portable excitation sources but are non, coherent. Therefore, in this study, a relatively low cost lens - a type of Ramsden eyepiece - was specially designed to theoretically calculate the illumination and achieve a constant brightness across the pupil of an eye. In order to verify the capability of the developed light-emitting diode-acoustic (LEDA) systems, we carried out experiments on bovine and bigeye tuna eyeball samples, which are of similar size to the human eye, using low frequency (10 MHz) and high frequency (25 MHz) ultrasound transducers. High frequency ultrasound transducers are able to provide higher spatial resolution compared to low frequency ultrasound transducers at the expense of penetration depth. Using the 10 MHz and 25 MHz ultrasound transducers, acceptable echo signals (3.82, 3.94, and 5.84 mV at 10 MHz and 282, 1557, 2356 mV at 25 MHz) from depth greater than 3 cm and 6 cm from the anterior surface of the eye were obtained. We thereby confirmed that the LEDA system using a pulsed LED with the designed Ramsden eyepiece lens, used in conjunction with low and high frequency ultrasound transducers, has the potential to be a cost-effective alternative method, while providing adequate acoustic signals from bovine and bigeye tuna ocular areas.

Study of Optical Fiber Sensor Systems for the Simultaneous Monitoring of Fracture and Strain in Composite Laminates (복합적층판의 변형파손 동시감지를 위한 광섬유 센서 시스템에 관한 연구)

  • 방형준;강현규;홍창선;김천곤
    • Composites Research
    • /
    • v.16 no.3
    • /
    • pp.58-67
    • /
    • 2003
  • To perform the realtime strain and fracture monitoring of the smart composite structures, two optical fiber sensor systems are proposed. The two types of the coherent sources were used for fracture signal detection - EDFA with FBG and EDFA with Fabry-Perot filter. These sources were coupled to EFPI sensors imbedded in composite specimens. To understand the characteristics of matrix crack signals, at first, we performed tensile tests using surface attached PZT sensors by changing the thickness and width of the specimens. This paper describes the implementation of time-frequency analysis such as short time Fourier transform (STFT) and wavelet transform (WT) for the quantitative evaluation of fracture signals. The experimental result shows the distinctive signal features in frequency domain due to the different specimen shapes. And, from the test of tensile load monitoring using optical fiber sensor systems, measured strain agreed with the value of electric strain gage and the fracture detection system could detect the moment of damage with high sensitivity to recognize the onset of micro-crack fracture signal.

Proeutectoid ${\alpha}$ Reaction at Sub-eutectoid Temperatures in Binary Bypoeutectoid Ti-Co, Ti-Fe Alloys (2원계 아공석 Ti-Co, Ti-Fe 합금의 공석반응 온도 아래의 온도에서 초석 ${\alpha}$ 반응)

  • Lee, Hwack-Joo
    • Applied Microscopy
    • /
    • v.24 no.3
    • /
    • pp.78-86
    • /
    • 1994
  • A TEM study on proeutectoid ${\alpha}$ reaction at sub-eutectoid temperatures has been made in hypoeutectoid Ti-3.gw/o Co and Ti-5.2w/o Fe alloys. Widmanstatten ${\alpha}$ plates were formed in both alloys within the ${\beta}$ matrix with some modification of degenerate forms. These degenerate plates were formed by the sympathetic nucleation of ${\alpha}$ plates at ${\alpha}:{\beta}$ interphase boundaries. Three types of sympathetic nucleation, i.e., edge-to-edge, face-to-edge, face-to-face, were found in both alloys. The edge-to-edge sympathetically nucleated crystals formed a low-angle boundary between two crystals. The ${\alpha}:{\beta}$ interphase boundaries were found to be partially coherent interfaces which consist of regularly spaced misfit dislocations. The growth of these interphase boundaries were accomplished by the lateral movement of growth ledges. The intersection points of two ${\alpha}$ plates or the low angle boundaries which had formed by edge-to-edge sympathetic nucleation played a role as the potential sources of growth ledges during the growth of plate. The interfacial structures and the spatial morphologies of the degenerate proeutectoid ${\alpha}$ plates would be expected to influence the nucleation and growth of the succeeding eutectoid decomposition process.

  • PDF