• 제목/요약/키워드: Coefficient of Permeability

검색결과 609건 처리시간 0.03초

교란효과와 배수저항을 고려한 연직 배수재 설계 (Design of Vertical Drain in Consideration of Smear Effect and Well Resistance)

  • 이달원
    • 한국농공학회지
    • /
    • 제42권4호
    • /
    • pp.115-123
    • /
    • 2000
  • This study compared the degree of consolidation by hyperbolic, curve fitting , Asaoka's and methods using values measured with a theoretical curve in consideration of smear effect and well resistance. The degree of consolidation by the Hyperboilc method was underestimated than the degree of consolidation by Curve fitting. Asaoka's , and Monden's methods. The typical range of the coefficient of horizontal consolidation was Ch=(2-3)Cv in the case considering smear effect and well resistance, and Ch =(0.5-2.1) Cv in the case disregarding smear effect and well resistance. The degree of consolidation obtained by ground settlement monitoring was nearly the same value when the coefficient of smear zone permeability by back analysis was shown to be half that of in-situ and the diameter of the smear zone was shown to be double that of mandrel. By increasing the diameter reduction ratio of the drain, the time of consolidation was delayed. The effect of well resistance showed that the case of a small coefficient of permeability was much more than in the case of a large coefficient of permeability . It was recommended that when designing diameter reduction of a drain, well resistance should be considered.

  • PDF

원전콘크리트의 물리적 특성 변화 (A variation of physical properties of NPP concrete)

  • 이호재;김도겸;이장화;김재환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.379-380
    • /
    • 2010
  • 본 연구는 국내 원전구조물에 사용된 실제 재료와 배합조건으로 시편을 제작하여 공학적 방벽의 재령에 따른 물리적 특성의 변화를 관찰하였다. 압축강도, 탄성계수, 투기계수, 투수계수를 측정하여 원전 콘크리트의 물리적 특성을 성능을 평가한다.

  • PDF

배수용 Geotextlle의 평면투수 성능분석 (Analysis on Character and Ability of In -Plane Permeability of Geotextiles Used for Darainage)

  • 이상호
    • 한국지반공학회지:지반
    • /
    • 제8권3호
    • /
    • pp.61-74
    • /
    • 1992
  • Geoteztile drain의 설계를 위한 기초자료를 제시하기 위하여 배수용 geotextile을 대상으로 평면투수성능을 실험적으로 분석하였다. 일반적으로 압축응력의 증가에 대한 geotextile의 두께, 평면투수계수 및 전수성은 10KN/m2 정도 이하에서 현자한 감소를 보였으며 Geotextile의 평면투수계수는 장섬유부직포가 단섬유부직포나 복합포 보다 낮게 나타났다. 또한 Geotextile의 압축률은 PES. 계부직포가 PP계 부직포 보다 큰 경향을 보였으며 geotextile의 압축음력 e(KN In)와 압축률 Cr(oA)의 관계식은 Cr=13.37 In+23.28로 표시되었고 2KN In"를 기준 으로 한 압축률 Cr'와 평면 투수계수 감소율 Pr의 관계식은 Pr=1.250r'로 표시되었다.

  • PDF

미세 Diatom 입자 이동에 의한 모래지반의 투수 특성 변화 (Change of Hydraulic Properties of Sand due to Fine Diatom Particle Migration)

  • 표원미;이종섭;이주용;홍원택
    • 한국지반공학회논문집
    • /
    • 제34권2호
    • /
    • pp.19-32
    • /
    • 2018
  • 심해저 지반에서 가스하이드레이트를 추출하는 경우 diatom과 같은 미세 입자 이동으로 인하여 해저 사면파괴 및 생산성 저하가 발생할 수 있으므로, 미세 입자 이동과 동반한 해저 지반특성 변화에 대한 연구가 요구된다. 본 연구에서는, 모래 지반에 대하여 투수가 발생할 시 미세 diatom 입자 이동으로 인한 지반의 수리 특성 변화를 평가하고자 하였다. 우선 동해 울릉분지 가스하이드레이트 퇴적층을 모사하기 위하여 주문진 표준사와 diatom 혼합 시료를 부피비에 따라 15개의 시료로 조성 및 변수위 투수실험을 수행하였다. 또한 diatom 부피비 50% 및 0%인 교호층 시료의 상 하부 수압차를 3kPa, 6kPa, 9kPa로 조정하여 정수위 투수실험을 수행함으로써 미세 diatom 입자 이동을 모사하고 입자이동 구간에서의 투수계수 및 전기비저항을 측정하였다. 변수위 투수 실험 결과, diatom의 부피비가 증가할수록 시료의 투수계수가 감소하였고, 투수계수 감소 곡선은 diatom 부피비가 10% 이하일 때보다 10%~50% 구간에서 기울기가 완만해 졌으며, diatom 부피비가 50%이상일 때 다시 기울기가 증가하였다. 정수위 투수 실험 결과, diatom이 이동하여 diatom 입자 이동 구간의 투수계수는 감소하고 전기비저항은 증가하였다. 본 연구는 미세 입자 이동이 교호층 지반의 투수계수를 감소시키며, 투수계수와 전기비저항의 반비례관계를 바탕으로 미세 입자 이동으로 인한 혼합시료의 거동을 예측할 수 있음을 보여준다.

하중증가비에 따른 충주댐 퇴적지반의 압밀 특성 (Consolidation Characteristics of Chungju Dam Deposit Soil in the Load Increment Ratio)

  • 이준대;오세욱
    • 한국안전학회지
    • /
    • 제15권4호
    • /
    • pp.123-126
    • /
    • 2000
  • This study shows consolidation properties resulted from the experiment made on changes by load increment ratio and consolidation duration of standard consolidation test using deposit soil of Chungju Dam. Though the comparison and analysis of the result turned out that void ratio by load increment ratio was unchanged greatly, the result was inclined as followes : the smaller load increment ratio is, the bigger void ratio is, while the bigger load increment ratio is the bigger settlement is. Also coefficient of consolidation is increased in inverse ratio to load increment ratio. Coefficient of permeability is increased in proportion to load increment ratio, it is not fixed changes by consolidation duration, however. Degree of consolidation is increased to load increment ratio.

  • PDF

실내모형실험을 통한 연직배수재 타설에 의한 스미어존의 평가 (An Estimation of Smear Zone Induced by Vertical Drain Construction Based on the Laboratory Model test)

  • 김홍택;한연진;김승욱;황정순
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.279-282
    • /
    • 2007
  • When ground disturbance takes place due to vertical drain construction through mandrel penetration, that affects excess pore water pressure dissipation time because of soft clay coefficient of permeability decreasing. Eventually, consolidation time is influenced. In this research, we measure process of excess pore water pressure dissipation before and after each other different shape's mandrel penetration through model test, and calculates range of smear zone, coefficient of permeability and horizontal coefficient of consolidation after model test. Using of test result, we grasp a degree of drainage ability drop resulting from vertical drain construction.

  • PDF

콘크리트에 도포된 도막의 투기계수 측정을 통한 장기 중성화 깊이 예측 (Prediction of Long-Term Carbonation Depth by Measurement of the Air Permeability Coefficient of Coating on Concrete)

  • 박동천;남민석;김용로;고효진;류동우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.113-114
    • /
    • 2023
  • This study measured the thickness and speculation coefficient of the coating for existing buildings and calculated the diffusion coefficient of the coating to predict the depth of carbonation through numerical analysis in order to evaluate the impact of the external finish and local environment. As a result, it was possible to predict the short-term and long-term carbonation depth of reinforced concrete buildings coated with coating film with considerable reliability.

  • PDF

피에조 콘 시험과 실내시험을 이용한 양산점토의 투수특성 평가 (Evaluation of Permeability Characteristics of Yangsan Clay using Piezocone Penetration Tests and Laboratory Tests)

  • 구남실;김영민;박재환
    • 한국지반환경공학회 논문집
    • /
    • 제12권12호
    • /
    • pp.47-54
    • /
    • 2011
  • 점성토 지반의 거동은 압축성뿐만 아니라 투수특성에 크게 영향을 받으며, 특히, 투수특성은 흙의 특성, 이방성에 따라 다르게 나타난다. 투수계수는 주로 실내 압밀시험과 현장 피에조 콘 시험으로부터 산정이 가능하다. 피에조 콘에 의한 투수계수 산정방법은 과잉간극수압의 소산시험 결과로부터 추정할 수 있다. 본 논문에서는 간극수압 소산시험 및 실내시험결과(Oedometer test)를 이용하여 기존의 투수성 평가에 이용되는 이론 해들의 적용성을 검토하고자 하며, 점성토지반 특성에 따른 ${k_{h}/k_{v}}$의 변화를 파악하여 원위치 ${k_{h}/k_{v}}$를 합리적으로 추정할 수 있는 적합한 해를 선정하였다. 연구대상지반은 경남 양산물금 지역의 점성토층이며 원위치 시험인 피에조 콘 소산시험과 비교란 시료에 대한 실내압밀시험(Oedometer test)을 실시하고 각 투수계수 추정해 별로 비교 분석을 실시하였다. 연구결과 피에조 콘 소산시험으로 산정된 투수계수비가 5.85로 나타나 실내시험(Rowe cell/Oedometer)으로 산정된 투수계수비 5.28과 매우 유사한 값을 나타냈다.

폐타이어 파우더 혼합토의 동상 특성 (Frost-Heaving Characteristics of Soil Mixed with Discarded Tire Powder)

  • 김학삼;서상열;중촌대;복전정기;산하총;영목휘지
    • 한국지반공학회논문집
    • /
    • 제26권4호
    • /
    • pp.15-26
    • /
    • 2010
  • 폐타이어 파우더 혼합에 따른 동상억제 메커니즘을 규명하기 위해, 부동수, 열전도율, 동상실험 등 3종류의 실내실험을 수행하였다. 본 연구에서는 폐타이어 혼합에 따른 투수계수 변화에 주목하여 먼저 마동결토의 불포화 투수계수를 계산하였고 ice-impeding factor, 혼합토내 토립자와 폐타이어 단면적을 고려하여 동결토frozen fringe내의 온도변화에 따른 투수계수 특성을 분석하였다. 그 결과 흡수속도와 투수계수 사이에는 비례관계가 존재함을 확인하였고, 동상성 저하의 주된 원인은 폐타이어 파우더 혼합에 따른 부동수분량과 투수계수의 감소임을 알 수 있었다. 또한 폐타이어 파우더 혼합토 구성성분의 체적비를 이용하여 흙과 폐타이어 간극내의 수분량을 정량적으로 산출하였다.

Rapid Measurement of $NH_3$ and Weak Acid Permeation Through Liposomes and Renal Proximal Tubule Membranes

  • Bae, Hae-Rahn;Suh, Duck-Joon;Lee, Sang-Ho
    • The Korean Journal of Physiology
    • /
    • 제28권2호
    • /
    • pp.203-214
    • /
    • 1994
  • Using the methods of stopped-flow and epifluorescence microscopy with entrapped fluorophore, membrane permeability of $NH_3$ and weak acids in liposomes, renal brush border (BBMV) and basolateral membrane vesicles (BLMV), and primary culture cells from renal proximal tubule was measured. Permeability coefficient (cm/sec) of $NH_3$ was $(2.9{\times}10^{-2}$ in phosphatidylcholine liposome $25^{\circ}C)$, $5.9{\times}10^{-2}$ in renal proximal tubule cell $(37^{\circ}C)$, $4.0{\times}10^{-2}\;and\;2.4{\times}10^{-2}$ in BBMV and BLMV $(25^{\circ}C)$, respectively. Formic acid has the highest permeability coefficient among the weak acids tested, which was $4.9{\times}10^{-3}$ in liposome, $5.0{\times}10^{-3}$ in renal proximal tubule cell, $9.1{\times}10^{-3}$ in BBMV and $3.8{\times}10^{-3}$ in BLMV. There was a linear relationship between external concentration of nonionized formic acid and initial rate of flux of formic acid in liposome, and the slope coincided with the value of permeability coefficient of formic acid measured in pH 7.0. These results show that techniques of stopped-flow and epifluorescence microscopy with entrapped fluorophore provide the precise method of measurement of very rapid transport of nonelectrolytes through membranes with the advantages of instantaneous mixing effect, good resolution time and easy manipulation.

  • PDF