• Title/Summary/Keyword: Codex

Search Result 405, Processing Time 0.032 seconds

Saxitoxin and Its Analogues: Toxicity, Analytical Method, Occurrence and Safety Management (삭시톡신과 그 유사체: 독성, 분석법, 국내외 오염도 및 관리 동향)

  • Lee, Sang Yoo;Im, Ju Hee;Woo, So Young;Choi, Hwa Young;Park, Su Been;Yoo, Cha Nee;Chun, Hyang Sook
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.6
    • /
    • pp.521-534
    • /
    • 2020
  • Paralytic shellfish poisoning (PSP) occurs when saxitoxin (STX), which is produced by harmful algae (dinoflagellates) and then accumulated in bivalve shellfish by filter-feeding, is consumed by humans. With recent advances in analysis technology, it has been reported that dinoflagellates also produce a variety of analogues such as the gonyautoxin (GTX) group and the N-sulfo-carbamoyl toxin (C toxin) group, in addition to STX. Accordingly, CODEX and the EFSA are stepping forward to manage STX and analogues as STX groups requiring safety management. In Korea, the occurrence of dinoflagellates producing STX analogues has already been reported, and contamination of analogues (GTX group, C toxin group) in live mussels has also been reported. In this study, in order to provide the basis for systematic monitoring and safety management of STX and analogues, their physicochemical characteristics, occurrence of dinoflagellates, toxicity and toxic equivalency factor, analytical method and occurrence were widely reviewed. This review is expected to contribute to strengthening the safety management of STX and its analogues.

Determination of Heavy Metal Concentration in Herbal Medicines by GF-AAS and Automated Mercury Analyzer

  • Kim, Sang-A;Kim, Young-Jun
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.4
    • /
    • pp.281-288
    • /
    • 2021
  • This study was conducted to analyze and compare the concentrations of heavy metals in 430 different products of 20 types of herbal medicines available in the domestic market in Korea by Graphite Furnace-Atomic Absorption Spectrometry (GF-AAS) and automated mercury analyzer. The accuracy for lead (Pb), arsenic (As), cadmium (Cd), and mercury (Hg) was in the range 92.67-102.56%, and the precision was 0.21-6.00 relative standard deviation (RSD%), which was in compliance with the Codex acceptable range. Furthermore, the Food Analysis Performance Assessment Scheme (FAPAS) quality control (QC) material showed a recovery range of 96.7-102.0% and 0.33-4.93 RSD%. The average contents (㎍/kg) of Pb, As, Cd, and Hg in herbal medicines were 254.9 (not detected (N.D.)-2,515.2), 171.0 (N.D.-2,465.2), 99.2 (N.D.-797.1), and 6.0 (N.D.-83.6), respectively. Based on the quantitative analysis results, the heavy metal contents of 20 types of herbal medicines distributed in Korea are within the acceptable range according to the standards issued by the Ministry of Food and Drug Safety (MFDS). By using the manufacturer of herbal products as the standard for QC, the Pb, As, Cd, and Hg contents were investigated in the packaging process just before distribution to determine the actual conditions of residual heavy metals in herbal medicines. Thus, these result may contribute to monitoring the QC of herbal medicines distributed in Korea and could provide basic data for supplying safe herbal medicines to the public.

Determination of Sodium Alginate in Processed Food Products Distributed in Korea

  • Yang, Hyo-Jin;Seo, Eunbin;Yun, Choong-In;Kim, Young-Jun
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.6
    • /
    • pp.474-480
    • /
    • 2021
  • Sodium alginate is the sodium salt of alginic acid, commonly used as a food additive for stabilizing, thickening, and emulsifying properties. A relatively simple and universal analysis method is used to study sodium alginate due to the complex pretreatment process and extended analysis time required during the quantitative method. As for the equipment, HPLC-UVD and Unison US-Phenyl column were used for analysis. For the pretreatment condition, a shaking apparatus was used for extraction at 150 rpm for 180 minutes at room temperature. The calibration curve made from the standard sodium alginate solution in 5 concentration ranges showed that the linearity (R2) is 0.9999 on average. LOD and LOQ showed 3.96 mg/kg and 12.0 mg/kg, respectively. Furthermore, the average intraday and inter-day accuracy (%) and precision (RSD%) were 98.47-103.74% and 1.69-3.08% for seaweed jelly noodle samples and 99.95-105.76% and 0.59-3.63% for sherbet samples, respectively. The relative uncertainty value was appropriate for the CODEX standard with 1.5-7.9%. To evaluate the applicability of the method developed in this study, the sodium alginate concentrations of 103 products were quantified. The result showed that the detection rate is highest from starch vermicelli and instant fried noodles to sugar processed products.

Determination and Validation of Synthetic Antioxidants in Processed Foods Distributed in Korea

  • Park, Hyeon-Ju;Seo, Eunbin;Park, Jin-Wook;Yun, Choong-In;Kim, Young-Jun
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.5
    • /
    • pp.297-305
    • /
    • 2022
  • Antioxidants are food additives that extend the shelf life of food products by preventing lipid rancidity caused by active oxygen. They can either be naturally-derived or manufactured synthetically via chemical synthesis. In this study, method validation of five synthetic antioxidants, namely butylated hydroxyanisole, butylated hydroxytoluene, tertiary butylhydroquinone, propyl gallate, and disodium ethylenediaminetetraacetic acid, was performed using a high performance liquid chromatography-ultraviolet visible detector, and the method applicability was evaluated by analyzing foods containing antioxidants. The coefficient of determination (R2) average was 0.9997, while the limit of detection and limit of quantification were 0.02-0.53 and 0.07-1.61 mg/kg, respectively. The intra and inter-day accuracies and precisions were 83.2±0.7%-98.7±2.1% and 0.1%-5.7% RSD, respectively. Inter-laboratory validation for accuracy and precision was conducted using the Food Analysis Performance Assessment Scheme quality control material. The results satisfied the guidelines presented by the AOAC International. In addition, the expanded uncertainty was less than 16%, as recommended by CODEX. Consequently, to enhance public health safety, the results of this study can be used as basis data for evaluating the intake of synthetic antioxidants and assessing their risks in Korea.

Study Analysis of Isocycloseram and Its Metabolites in Agricultural Food Commodities

  • Ji Young Kim;Hyochin Kim;Su Jung Lee;Suji Lim;Gui Hyun Jang;Guiim Moon;Jung Mi Lee
    • Korean Journal of Environmental Agriculture
    • /
    • v.42 no.1
    • /
    • pp.71-81
    • /
    • 2023
  • An accurate and easy-to-use analytical method for determining isocycloseram and its metabolites (SYN549431 and SYN548569) residue is necessary in various food matrixes. Additionally, this method should satisfy domestic and international guidelines (Ministry of Food and Drug Safety and Codex Alimentarius Commission CAC/GL 40). Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) was used to determine the isocycloseram and its metabolites residue in foods. To determine the residue and its metabolites, a sample was extracted with 20 mL of 0.1% formic acid in acetonitrile, 4 g magnesium sulfate anhydrous and 1 g sodium chloride and centrifuged (4,700 G, 10 min, 4℃). To remove the interferences and moisture, d-SPE cartridge was performed before LC-MS/MS analysis with C18 column. To verify the method, a total of five agricultural commodities (hulled rice, potato, soybean, mandarin, and red pepper) were used as a representative group. The matrix-matched calibration curves were confirmed with coefficients of determination (R2) ≥ 0.99 at a calibration range of 0.001-0.05 mg/kg. The limits of detection and quantification were 0.003 and 0.01 mg/kg, respectively. Mean average recoveries were 71.5-109.8% and precision was less than 10% for all five samples. In addition, inter-laboratory validation testing revealed that average recovery was 75.4-107.0% and the coefficient of variation (CV) was below 19.4%. The method is suitable for MFDS, CODEX, and EU guideline for residue analysis. Thus, this method can be useful for determining the residue in various food matrixes in routine analysis.

Chemical characteristics of Soils Cultivated by the Conventional Farming, Greenhouse Cultivation and Organic Farming and Accumulation of $NO_3^-$ in Chinese Cabbage and Lettuce (관행농법, 시설재배 및 유기농법 재배지 토양의 화학적 특성과 배추, 상추의 $NO_3^-$ 집적량 차이)

  • 손상목;한도희;김영호
    • Korean Journal of Organic Agriculture
    • /
    • v.5 no.1
    • /
    • pp.149-165
    • /
    • 1996
  • In order to get some basic datas on environmental friendly funtion against soil and water pollution and safe vegetable production by organic farming, chemical characteristics of soils cultivated by the conventional farming, greengouse cultivation and organic farming and acumulation of NO3--N in chinese cabbage and lettuce were analysed. The highest value of NO3--N in 0-30cm subsoil of organic farming was found among the 3 different farming systems, and it was 3.6 and 6.6 times higher than those of conventional farming in chinese cabbage and lettuce respectively. P2O5 also show high accumulation in the rhizosphere of organic farming compared to convnetional farming. The accumulation of NO3--N and P2O5 in the rhizosphere of organic farming were simial to those of greenhouse cultivation. The NO3- accumulation in chinese cabbage and lettuce by organic farming reach 3224ppm in chinese cabbage and 2543ppm in lettuce and it were 4.7 and 6.4 times higher than those of convnetional farming. It is urgently necessary to introduce the basic standard of IFOAM, EU and FAO/WHO Codex on organic agriculture into korean organic agriculture for operation of environmental friendly system and production of safe vegetable in terms of NO3-.

  • PDF

Environmental Friendly Function and Safe Food Production by Organic Agriculture in Europe (선진 유럽유기농업의 환경보전 기능과 안전농산물 생산-한국유기농업의 발전을 위한 농업정책적 제안-)

  • 정길생;손상목;이윤건
    • Korean Journal of Organic Agriculture
    • /
    • v.5 no.1
    • /
    • pp.45-66
    • /
    • 1996
  • In Korea there is still no basic standard for organic agriculture and organic farmers in Korea do not follow the minimum requirements of IFOAM basic standard Most of them just practice the organic agriculture applying organic fertilizer, commercial seed without legume, rotation and green manure. But they believe this system is a absolutely environmental friendly agricultural system and it produce a safe agricultural product since they are not aware of the basic standard of organic agriculture at all. The overuse of organic fertilizer by some organic farmer have caused some severe problems risk for nitrate and phosphate leaching. In soil profile showed the potential risk for nitrate and phosphate leaching. In the paper, it is discussed on the environmental friendly function and the safe vegetable production by european organic agriculture which keeps the internationally recognized basic standards of organic agriculture. Therefore it is strongly recommended that korean organic farmer have to follow the IFOAM it is strongly in order to practice the environmental agriculture and produce the safe food. And it is also necessary to introduce to Korea the basic standard of organic agriculture which coincides with IFOAM's and Codex of FAO/WHO immediately if they really want to practice an organic agriculture in the country.

  • PDF

Breastfeeding and Melatonin (모유 수유와 멜라토닌)

  • Song, Minyu;Park, Won Seo;Yoo, Jayeon;Ham, Jun-Sang
    • Journal of Dairy Science and Biotechnology
    • /
    • v.36 no.3
    • /
    • pp.133-145
    • /
    • 2018
  • Breastfeeding is highly recommended due to its benefits for both the infant and mother; however, most mothers predominantly use formula feed. Breastfeeding affords protection against a wide variety of medical conditions that may emerge at different time points over the lifespan, including hospital admissions for respiratory infections and neonatal fever, offspring childhood obesity, and cancer as well as cardiovascular disease, hyperlipidemia, hypertension, and diabetes. Moreover, breastfeeding is expected to decrease the risk of adolescent depression and other psychopathologies. It is also important for the development of the gut, gut-brain axis, and immune system, and night-time breast milk is likely to have higher antioxidant, anti-inflammatory, and immune regulatory effects due to the impact of breast milk melatonin on the infant's developing microbiome and gut permeability. Melatonin can be added to a night-time-specific formula feed; however, it is not included in the Korean Food Additive Codex.

Harmonization of MRL Setting for Compounds Used Both as Pesticides and as Veterinary Drugs with Regulatory Aspects - Cypermethrin in Food of Animal Origin (농약 및 동물용의약품으로 사용되는 약제의 잔류허용기준 설정 개선 - 축산물 중 cypermethrin의 잔류 사례)

  • Kwon, Jin-Wook
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.1
    • /
    • pp.89-97
    • /
    • 2011
  • BACKGROUND: Cypermethrins, possess eight isomers, used both as pesticide and as veterinary drug, were set different MRLs for livestock by CCPR and CCRVDF of Codex Alimentarius. Korea Food Code designates MRLs for livestock only as pesticide. METHODS AND RESULTS: This study presented necessaries of harmonization of MRL setting for compounds used both as pesticides and as veterinary drugs with regulatory aspects, showing an example of cypermethrin residue in livestock. CONCLUSION(S): For harmonization, following factors must be considered and recommended; designation of marker residue; alpha-cypermethrin, zeta- cypermethrin, and cypermethrin, clarification of the definition of target tissues; meat, fat, muscle, by-product, eggs, milk, and etc., method of analysis; clarification of target analytes of isomers, quantitation and calculation method as a principle of residue analysis.

Calibration: Theory and Practice (분석표준화와 검량선 작성의 국제적 동향)

  • Lee, Kyu-Seung;Kwon, Jin-Wook
    • Applied Biological Chemistry
    • /
    • v.46 no.4
    • /
    • pp.271-279
    • /
    • 2003
  • Various definitions and terminology applied to measurement in analytical chemistry are not always consistent. But, internationally integrated terminology and interpretation of definitions play an essential role in analytical chemistry fields. The review in this paper focused on problems associated with terminology, definitions, statistical theories, and practical performance of calibration and validation.