• 제목/요약/키워드: Cobra

검색결과 83건 처리시간 0.027초

IRMA 법 Curve에 관하여 (How about IRMA Curve)

  • 장현영;신선영;이현주;우재룡;이호영
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.156-161
    • /
    • 2012
  • IRMA법의 실험결과 측정 시 각 축의 설정과 곡선 유형에 따라서 값이 다르게 계산되어 나온다. 시약의 안내서에 있는 대로 설정을 하되 안내가 되어 있지 않은 경우에는 안내서의 도표를 참고하여 설정을 하거나. 어려가지 실험을 통해서 가장 최적화된 설정 값을 찾아내야 한다. 본 실험에서 Immunotech사의 TSH에서는 Linear-Logit 값이 가장 좋은값을 나타낸다고 사료된다. 작은 규모의 실험실에서 감마카운터가 고장 시 SR-300을 이용하여 CPM만 측정 후 EXCEL을 이용하여 결과값을 계산 후 보고해도 좋을 것같다.

  • PDF

Comparison of the Electromyographic Activity in the Lower Trapezius Muscle According to Four Different Types of Exercises in Healthy Adults

  • Seo, Gyeong Ju;Park, Ji Won;Kwon, Yonghyun
    • The Journal of Korean Physical Therapy
    • /
    • 제31권2호
    • /
    • pp.134-139
    • /
    • 2019
  • Purpose: This study examined the most effective exercise while performing shoulder abduction below ninety degrees. Methods: Thirty two healthy individuals (17 males, 15 females) participated and performed four exercises, 1) Posterior fly, 2) Prone row, 3) Modified prone cobra, and 4) External rotation in the prone position. Surface electromyography (sEMG) was used to measure the electrical activities for the lower, middle and upper fiber of trapezius and serratus anterior. Results: A significant difference in the muscle activities of the upper/middle/lower trapezius and serratus anterior was observed among the three different positions in terms of the PF (posterior fly), PR (prone row), and MPC (modified prone cobra) (p<0.05). In post-hoc analysis, the activities of the lower and upper trapezius were significantly higher than those of the upper trapezius and serratus anterior (p<0.05). In addition, in ERP (external rotation in prone), there was a significant difference in each activity of the muscles. Post-hoc results indicated that the upper trapezius showed greater EMG activity than the other three muscles. Conclusion: External rotation in the prone position revealed the highest activation of the lower trapezius compared to upper trapezius muscle activity. This may be particularly useful in isolating the lower trapezius in cases where excessive scapular elevation is noted. Therefore, the most effective lower trapezius exercise should be performed below ninety degrees of shoulder abduction.

IRMA 검사법 중 알고리즘 변경에 따른 장비 간 결과값 비교분석 (Comparison Analysis of The results of IRMA Test among Different Equipment According to Algorithm change.)

  • 김정인;권원현;이경재
    • 핵의학기술
    • /
    • 제23권2호
    • /
    • pp.43-50
    • /
    • 2019
  • 목적: 분당서울대병원 검체 검사실에서는 노후화된 전자동방사면역측정기의 교체로 인하여 새로운 자동화 장비가 도입이 되어, 검사원리가 IRMA법인 Insulin 검사로 장비 간 비교실험을 하게 되었다. 실험결과 장비간에 동일한 알고리즘인 선형 보간법을 적용하였음에도 불구하고 특히 저농도값에서 현저한 값 차이를 보였다. 이에 실험실내 보유중인 SR300, Gamma 10, Gamma Pro, Cobra 감마카운터 각각의 장비에 2가지의 알고리즘을 다르게 적용시켰을 때 값 차이를 알아보고자 하였다. 대상 및 방법: 검사원리가 IRMA법인 검사법 중 주로 자동화 장비에 검사가 시행 되고 있는 TSH, Ferritin, C-peptide, Insulin 4종목을 각각 10검체씩 저, 중, 고농도 값으로 선별하여 총 30개씩 동일한 검사항목에 대해서 SR300, Gamma 10, Gamma Pro, Cobra 카운터 장비에 선형 보간법과 스플라인 보간법으로 적용했을 때의 결과 값 차이를 비교하여 보았다. 결과: TSH, Ferritin, C-Peptide, Insulin 항목의 결과값에 선형 보간법과 스플라인 보간법을 다르게 적용시켜 장비간 상관성 검사를 시행한 결과 결정계수 $R^2$ 값은 0.9이상으로 모든 장비에서 상관성은 우수한 결과를 나타내었지만 통계적으로 유의성 검증결과 장비간 비교에서는 TSH를 제외하고 Ferritin, C-Peptide, Insulin 항목은 P값의 유의성이 0.001 미만으로 유의한 차이가 있었다. 선형 보간법과 스플라인 보간법 간의 결과값 비교에서는 TSH, ferritin, insulin을 제외하고 C-peptide 항목만 P값의 유의성이 0.03으로 보간법 간에 차이가 있음을 알 수 있었다. Insulin 낮은 값 영역에서 장비간 비교한 결과 P값의 유의성이 0.001 미만으로 Gamma Pro, Gamma 10, Cobra, SR300 카운터 장비간에 유의한 차이가 있었고 선형 보간법과 스플라인 보간법 간의 결과값 비교에서도 P값의 유의성이 0.001 미만으로 보간법간에 서로 유의한 차이가 있음을 알 수 있었다. 결론: 연구결과 검사원리가 IRMA법이면서 linear 보간법인 검사결과를 살펴보면 장비마다 Curve Fitting 방식 차이에 따라 Standard 0값을 설정해주는 기대치와 실측치의 값에 차이가 있음을 알 수 있었다. 이러한 원인으로 인해서 저농도 결과값에 영향을 미치고 장비 간에 차이가 유발됨을 알 수 있었다.

Improvement of crossflow model of MULTID component in MARS-KS with inter-channel mixing model for enhancing analysis performance in rod bundle

  • Yunseok Lee;Taewan Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4357-4366
    • /
    • 2023
  • MARS-KS, a domestic regulatory confirmatory code of Republic of Korea, had been developed by integrating RELAP5/MOD2 and COBRA-TF. The integration of COBRA-TF allowed to extend the capability of MARS-KS, limited to one-dimensional analysis, to multi-dimensional analysis. The use of COBRA-TF was mainly focused on subchannel analyses for simulating multi-dimensional behavior within the reactor core. However, this feature has been remained as a legacy without ongoing maintenance. Meanwhile, MARS-KS also includes its own multidimensional component, namely MULTID, which is also feasible to simulate three-dimensional convection and diffusion. The MULTID is capable of modeling the turbulent diffusion using simple mixing length model. The implementation of the turbulent mixing is of importance for analyzing the reactor core where a disturbing cross-sectional structure of rod bundle makes the flow perturbation and corresponding mixing stronger. In addition, the presence of this turbulent behavior allows the secondary transports with net mass exchange between subchannels. However, a series of assessments performed in previous studies revealed that the turbulence model of the MULTID could not simulate the aforementioned effective mixing occurred in the subchannel-scale problems. This is obvious consequence since the physical models of the MULTID neglect the effect of mass transport and thereby, it cannot model the void drift effect and resulting phasic distribution within a bundle. Thus, in this study, the turbulence mixing model of the MULTID has been improved by means of the inter-channel mixing model, widely utilized in subchannel analysis, in order to extend the application of the MULTID to small-scale problems. A series of assessments has been performed against rod bundle experiments, namely GE 3X3 and PSBT, to evaluate the performance of the introduced mixing model. The assessment results revealed that the application of the inter-channel mixing model allowed to enhance the prediction of the MULTID in subchannel scale problems. In addition, it was indicated that the code could not predict appropriate phasic distribution in the rod bundle without the model. Considering that the proper prediction of the phasic distribution is important when considering pin-based and/or assembly-based expressions of the reactor core, the results of this study clearly indicate that the inter-channel mixing model is required for analyzing the rod bundle, appropriately.

$\b{W}$COBRA/TRAC을 이용한 고리 1호기 대형냉각재 상실사고 해석

  • 이재훈;최동수;박병서;조창석;박진영
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.411-416
    • /
    • 1996
  • 최근 웨스팅하우스사가 SECY-83-472에 근거하여 개발한 최적평가방법론인 WCOBRA/TRAC UPI EM을 이용하여 Appendix K, Superbounded, Nominal 계산을 고리 1호기에 대하여 수행하였다. 15%증기발생기 관막음율, 출력 첨두 계수 2.35, 최대 선형 열출력 15.588kw/ft을 사용하여 계산한 결과 Appendix K 최대 피복재 온도는 1941℉로서 KAERI/Siemens가 RTSR 작성시 수행한 해석에 비하여 운전여유도가 증가한 것으로 나타났으며, 그 결과가 SECY 방법론에 합당함을 확인하였다.

  • PDF

천연 독소로부터 세포독성물질의 분리 및 정제

  • 김영식
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 1994년도 춘계학술대회 and 제3회 신약개발 연구발표회
    • /
    • pp.208-208
    • /
    • 1994
  • 코브라과 (Elapidae)에 속하는 뱀에는 극소량으로도 치사시킬수 있는 독을 가지고 있는데 독을 구성하고 있는 물질중 특정한 계열의 단백질이 매우 두드러진 약리학적 활성을 보여줄수 있다. 따라서 본 연구는 독사들의 혈액독소 및 신경독소를 우리나라에서 제일 종류가 많은 위암세포주(SNU-1)에 대해서 세포독성을 검색하고 곤충 및 해양생물의 독소에 대해서도 위암세포주를 이용하여 검색하였다. 검색 결과 king cobra계통인 Ophiophagus hannah의 분획은 SDS-PAGE에서 분자량이 66,000 부근에 나타난 것이 세포독성물질로 추측되며 더욱 정제하여 아미노산 서열을 비교하고 Phospholipase화성을 측정함으로써 세포독성물질의 규명이 가능하리라 생각된다.

  • PDF

사용후핵연료 장기 건식저장시 최대 초기저장 허용온도에 관한 연구

  • 박근일;이후근;변기호;노성기;박현수
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(3)
    • /
    • pp.470-475
    • /
    • 1996
  • 사용후핵연료 장기 건식저장시 여러가지 저장조건에서 사용후핵연료 피복관 및 사용후핵연료 ($UO_2$)에 대한 장기 건전성을 종합적으로 평가할 수 있는 SIECO 코드를 개발하였다. 건식저장 시스템은 사용후핵연료를 헬륨 및 공기분위기하에서 TN-24P 건식 저장용기에 장기 저장할 경우로 하였으며 피복관의 최대 표면온도는 COBRA-SFS코드를 사용하여 계산하였고, 열유동 해석결과를 바탕으로 SIECO코드를 이용하여 핵연료 연소도 및 냉각기간, 냉각매체에 따른 최대 건식저장 허용온도를 피복관의 열화 및 $UO_2$ 산화의 관점에서 계산하였다.

  • PDF