• 제목/요약/키워드: Coated file

검색결과 16건 처리시간 0.02초

치과용 Ni-Ti파일의 표면특성에 미치는 ta-C코팅효과 (Effects of ta-C Coatings on Surface Characteristics of Dental Ni-Ti Files)

  • 박순균;최한철
    • Corrosion Science and Technology
    • /
    • 제22권5호
    • /
    • pp.368-376
    • /
    • 2023
  • Dental Ni-Ti files must ensure stability and resistance to fatigue fracture. DLC and ta-C were coated to remove defects on the surface and ensure stability, and the surface characteristics were investigated. When coated with DLC, it was black, and in case of ta-C coating, it was blue-black. Scratches, which are defects caused by mechanical processing, were formed on the surface of the un-coated Ni-Ti file from the end of the file along the direction of processing, with the Pro-file appearing in the vertical direction and the K-file appearing in the file direction. Scratches were reduced on the coated surface, and the surface roughness was greatly reduced after coating compared to before coating. The un-coated Ni-Ti file had the lowest hardness, the DLC-coated file had the highest hardness, and ta-C showed relatively high hardness. The elastic modulus of the DLC coating film was high, and the ta-C elastic modulus was low. The adhesion of the DLC coating film tended to be higher than that of ta-C, and the wear loss amount of DLC coating of taC was lower. The corrosion potential of the ta-C coating increased significantly, and the corrosion current density decreased.

Determination of Chromium Content in Carbon Steel Pipe of NPP using ICP-AES

  • Choi, Kwang-Soon;Lee, Chang-Heon;Han, Sun-Ho;Park, Yong-Joon;Song, Kyu-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권12호
    • /
    • pp.4270-4274
    • /
    • 2011
  • A method is proposed for determining chromium content in the carbon steel pipes of a nuclear power plant (NPP) to evaluate wall thinning caused by flow-accelerated corrosion (FAC). A flat file was used to obtain filings samples. To assess sampling quality, a disk form of SRM 1227 was ground with the flat file, and the amount of Cr in the filings was determined by ICP-AES. The content of chromium in the filings of SRM 1227 was estimated as six times higher than the certified value due to the contamination of chromium in the file. To eliminate chromium contamination from the file, it was coated with WC-12Co using high-velocity oxygen-fuel (HVOF) spraying systems. After obtaining filings samples using the coated file, Cr content in four types of disk-form SRMs was determined by ICP-AES. The recoveries of Cr in the disk-form SRMs were in the range of 95.4-102.6%, with relative standard deviations from 0.43 to 3.0%. The Cr contents in the filings collected from the used outlet headers of the nuclear power plants using the flat file coated were in the range of 0.11-0.19%.

Sol-Gel법으로 제조한 PLZT 박막의 전기광학특성 (Electrooptic Properties of PLZT Thin Films Prepared by Sol-Gel Method)

  • 이성갑;정장호;배선기;이영희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1505-1507
    • /
    • 1996
  • In this study, $(Pb_{0.88}La_{0.12})(Zr_{0.40}Ti_{0.60})O_{2.97}$ (La/Zr/Ti=12/40/60) ceramic thin films were fabricated from an alkoxide-based by Sol-Gel method. PLZT stock solutions were made and spin-coated on the ITO-glass rubstrate at 4000[rpm] for 30[sec]. Coated specimens were baked to remove the organic materials at $400[^{\circ}C]$ for 10[min]. This procedure was repeated 5 times. The coated films were finally annealed at $450{\sim}700[^{\circ}C]$ for 1[hr]. The ferroelectric perovskite phases precipitated under the sintering of $550{\sim}700[^{\circ}C]$ for 1[hr]. Relative dielectric constant of the PLZT thin were increased with increasing the sintering temperature, the thin file sintered at $650[^{\circ}C]$ showed the highest value of 196. But in the PLZT thin film sintered at $700[^{\circ}C]$, relative dielectric constant was greatly decreased due to reacts between ITO electrode and glass substrate. In all thin films, the transmittance was more than 70[%] (at 632.8[nm]).

  • PDF

조명 시뮬레이션을 이용한 설치 환경별 차광판 선정에 관한 연구 (A study on selecting of Light Cutoff Panel depending on the installation condition using the lighting simulation)

  • 박형규;구진회;이규목
    • 한국산학기술학회논문지
    • /
    • 제17권2호
    • /
    • pp.246-251
    • /
    • 2016
  • 도로조명 중 누출광을 고려하지 않은 보안등이 아직도 많이 사용되어 주거지 침입광이 발생되고 있다. 이러한 도로조명의 침입광 저감을 위해 차광판이 설치되고 있지만, 효과가 미미하거나 미적 요소 및 안전성에 문제가 있다. 본 연구에서는 침입광 효율적인 저감을 위해 차광판 구조별 저감 특성을 연구하였으며, 그 방법으로 조명시뮬레이션 프로그램인 Relux 활용하였다. 또한 시뮬레이션의 값의 정확성을 알기 위해 실제 측정값과 검증하였다. 그 결과 (상)도색 글로브를 제외한 모든 차광판에서 후사광 저감 효과가 뛰어났으며, 도장형 차광판의 경우 전사광도 줄어들어 글레어 저감도 효율 적인 것으로 확인되었다. (상)도색 글로브는 위쪽으로 가는 빛을 아래로 반사시켜 후사광 전사광 모두 증가하였지만, 스카이 글로우(Sky glow) 저감에 효율적인 차광판으로 확인되었다. 시뮬레이션 값과 실측값은 90 %의 일치률을 보였다.

鑄鐵에 있어서의 黑鉛球狀化機構에 關한 硏究 (1) (Study on the Spheroidizing Mechanism of Graphite in Cast iron (part 1))

  • 최형섭;장지영
    • 대한화학회지
    • /
    • 제7권1호
    • /
    • pp.51-57
    • /
    • 1963
  • It is well known that the graphite flakes become spherulite, when a suitable amount of nodulizing element, such as cerium or magnesium, is added to the cast iron. The change of graphite from flake to nodular shape improves not only the tensile strength but the ductility as well. However, the mechanism of spheroidization of graphite in cast iron has not yet been clearly understood, and various theories proposed by a number of investigators were such that it may be due to the special nucleation effect, prevention of flake formation by the adsorption of magnesium vapour on the graphite surface or file surface free energy difference between plain graphite and magnesium-adsorbed graphite. Regardless of the speculations of spheroidizing mechanism of the graphite in the cast iron, the final phenomenon comes to the conclusion that it may be due to the lack of wettability between graphite and iron matrix. In order to collaborate this fact through an experimental method, the authors have constructed a vacuum arc furnace for the wettability measurement as its first step. Our study and experiments were then directed to the comparison of the wettability between iron and graphite on the two cases (namely, the one where magnesium was preliminarily coated on the graphite surface and the other not coated), by means of contact angle measurements. The result was such that a significant difference of the contact angles has been shown between the above two cases. indicating the spheroidization of graphite which might have resulted from the lack of wettability between magnesium-adsorbed graphite and iron matrix.

  • PDF

수동과 엔진구동형 기구를 이용한 난원형 근관의 형성에 관한 주사전자현미경적 관찰 (A SEM OBSERVATION ON THE EFFICIENCY PREPARATION OF OVAL CANALS USING HAND AND ENGINE-DRIVEN INSTRUMENTS)

  • 송욱;허복;이희주
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.141-146
    • /
    • 2004
  • The purpose of this study was to evaluate the efficiency of the preparation of oval canals using hand and engine-driven instruments with SEM observation. Thirty single-rooted teeth with oval canal were used in this study. The teeth were divided into 3 groups. In group A the teeth were instrumented up to a size 35 K-file using RC-prep and irrigated with 5% NaOCl between each file size. In group B. the teeth were instrumented with Profile according to the manufacture's instructions using RC-Prep and irrigated with 5% NaOCl between each file size. In group C. the teeth were instrumented with GT file according to the manufacture's instructions using RC-prep and irrigated with 5% NaOCl between each file size. Then. in all teeth. a final flush of 5ml of distilled water delivered for 30s. Canals were dried with sterile standardized paper points. After preparing the canals, the teeth were sectioned along their mesial and diatal surfaces by using low-speed diamond disc. chisel and mallet. Each root section was then dehydrated in graded concentration of alcohol (70, 80, 90, 100%). mounted on an aluminum stub. sputter-coated with gold-palladium and observed with scanning electron microscope (HITACHI S-4200) in middle and apical area. The results of this study were as follows: 1. In the middle area. group B and group C showed less smear layer than group A and it was statistically significant (p < 0.05). 2. In the middle area. group B showed greater smear layer than group C. but it was not statistically significant (p > 0.05). 3. In the apical area, group C showed less smear layer than group A. and it was statistically significant (p < 0.05). 4. In the apical area. group A showed greater smear layer than group B. but it was not statistically significant (p > 0.05). 5. In the apical area. group B showed greater smear layer than group C. but it was not statistically significant (p > 0.05). 6. In all groups. the middle area was less smear layer than the apical area. and it was statistically significant (p < 0.05).

근관세척(根管洗滌)에 관(關)한 주사전자현미경적(走査電子顯微鏡的) 연구(硏究) (A SCANNING ELECTRON MICROSCOPIC STUDY OF THE EFFICACY OF ROOT CANAL IRRIGATION)

  • 이명종
    • Restorative Dentistry and Endodontics
    • /
    • 제8권1호
    • /
    • pp.147-153
    • /
    • 1982
  • The purpose of this study is to observe the effect of cleansing action of irrigation solutions which are 3% hydrogen peroxide, 5% sodium hypochlorite and 15% EDTA solution on the root canal wall. After the root canal wall is enlarged with K-file in distilled water, the canal wall which is irrigated with each irrigant for 2 minutes, is compared with the. control group without using any irrigants. Each sample is dehydrated, and coated with 200-250${\AA}$ of gold, and observations are made with the use of scanning electron microscope. The results are as follows: 1. The canal walls irrigated with 3% hydrogen peroxide, 5% sodium hypochlorite and 15% EDTA solution are cleaner than the walls without using irrigants. 2. There are no significant difference of cleansing effect among 3% hydrogen peroxide, 5% sodium hypochlorite and 15% EDTA. 3. After using 3% hydrogen peroxide and 5% sodium hypochlorite solution, large debris are removed on root canal walls, but micro debris remain on the canal walls. 4. The root canal walls irrigated with 15% EDTA solution are decalcifed slightly and show clean surfaces.

  • PDF

Comparison of root canal preparation by three Ni-Ti instruments

  • Shibutani, Takuya;Ozaki, Kazumi;Matsuo, Takashi
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.547-547
    • /
    • 2003
  • The aim of this study was to compare the effects of three Ni-Ti instruments on leaning ability by evaluating the volumetric and morphological changes in the apical 6mm of the root canals before and after preparation, using three-dimensionally reconstructed root canals of extracted human teeth. Forty-five teeth were used in this study. They were opened the chambers and removed the all pulp remnants ultrasonically. Subsequently, the canal wall was coated with silver paste and prepared using ProTaper, ProFile and GT rotary files according to the manufacturers instructions. Before and after root canal preparation, all the specimens were scanned with micro computed tomography and examined the differences in dentine volume removed, canal straightening, the proportion of the unchanged area and canal transportation. Quantitative analysis revealed that instrumentation increased in canal volume ranging between 0.081 and $1.866{\;}\textrm{mm}^3$. On average, the large apical preparation produced by ProTaper demonstrated smaller proportions of unchanged surface areas compared to the two other instruments in small canals. But in large canals like maxillary central incisor, the preparation of ProTaper instruments was not enough. ProTaper instrument was tended to increase more in canal volume as compared with the other two instruments but unchanged area was no significant difference. These results showed that three instruments had similar preparation ability and micro computed tomography in combination with the coated wall of root canal using silver paste is a nondestructive and valuable tool to study root canal geometry and changes after preparations in detail.

  • PDF

Functional Nannomaterials Based on Nanoporous Template

  • 김진곤;양승윤;변진석;전금혜;조아라
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.7.1-7.1
    • /
    • 2011
  • Nanoporous templates have been widely used for the development of new functional nanostructured materials suitable for electronics, optics, magnetism, and energy storage materials. We have prepared nanoporous templates by using thin films of mixtures of polystyrene-block-poly (methyl methacrylate) (PS-b-PMMA) and PMMA homopolymers. These templates have cylindrical nanoholes spanning the entire thickness of the film. Some applications of nanoporous templates are introduced: a) anti-reflective coating, b) the preparation of conducting polymer nanowires of poly (pyrrole), poly (3,4-ethylenedioxy-thiopene) onto a glass coated with indium-tin-oxide, and c) the separation membranes for biomaterials. We found that when the pore fraction of nanoholes in the film was ~0.68, almost zero reflectance at a specific wavelength, which can be changed with film thickness, was achieved at visible wavelengths Furthermore, ultra high density array of conducting nanowires was successfully prepared onto various substrates including flexible polymer. Due to highly alignment of polymer chain along the nanowire direction, the conductivity was much increased. Furthermore, these nanoporous films were found to be very effective for the separation of human Rhinovirus type 14 (HRV 14), major pathogen of a common cold in humans, from the buffer solution. We also found that when the pore size was effectively controlled down to 6 nm, a single file diffusion was observed.

  • PDF

Sol-Gel법에 의한 $PbTiO_3$ 박막의 제조 및 유전 특성 (Preparation and Dielectric Properties of the $PbTiO_3$ Thin Film by Sol-Gel Method)

  • 정장호;박인길;류기원;이영희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1434-1436
    • /
    • 1996
  • In this study, ferroelectric $PbTiO_3$ thin films were deposited on the Pt/$SiO_2$/Si substrate by Sol-Gel method. $PbTiO_3$ stock solution was made and spin-cooled at 4000[rpm] for 30[sec.]. Coated specimens were dried at $400[^{\circ}C]$ for 10[min.] and then annealed at $500{\sim}800[^{\circ}C]$ for 1 hour. Annealing temperature were examined to optimize micro structural and dielectric properties of the films. The ferroelectric perovskite phase was observed in the file annealed at $700[^{\circ}C]$ for 1 hour. In the case of $PbTiO_3$ thin films annealed at $700[^{\circ}C]$ for hour, dielectric constant and dielectric loss showed the good value of 324, 2.0[%], respectively.

  • PDF