• Title/Summary/Keyword: Coal dust

Search Result 141, Processing Time 0.036 seconds

Performance Enhancement of Flue Gas Desulfurization System with Structural Constraints in 500 MW Coal Fired Power Plants (구조적 제약조건을 갖는 500 MW 석탄화력발전소 탈황설비의 성능개선)

  • Kim, Jong-Sung;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.4
    • /
    • pp.30-35
    • /
    • 2019
  • To meet both increasing social demand for reduction of fine dust and the strengthened air pollutant emission standards, this paper indicated performance enhancement of FGD with structural constraints in 500 MW coal fired thermal power plant's. Through modifying internal facilities for flue gases to make swirl in the absorption tower, it made turbulence and increased the efficiency of material transfer, the reaction area and time with the limestone slurry. Therefore, it could reduce dust and enhance the performance of collecting the SO2. As a result, desulfurization efficiency was improved from 91.61% to 98.43% and dust removal efficiency was improved from 77.4% to 87.08%. Emission density is 7.85 ppm of SO2 and 4.67 mg/㎥ of dust. This is a level that satisfies emission limit of 25 ppm of SO2 and 5 mg/㎥ of dust which are the air pollutant emission standards of 2023. The performance enhancement method of this study is expected to be effectively applied to other coal-fired power plants with similar constraints.

Source Apportionment of Fine Particle $PM_{2.5}$ in Beijing, China

  • Zhang, Yuanhang;Zhu, Xianlei;Zeng, Limin;Wang, Wei
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.216-225
    • /
    • 2003
  • Fine particles with aerodynamic diameter less than 2.5 ${\mu}m$ (PM2.5) were collected from three sites in Beijing during April, August, and November 2000 and January 2001. After chemical components in samples are analyzed, a chemical mass balance (CMB) receptor model using PARs as tracers is applied to quantify the source contributions to PM2.5 in Beijing. The results show that the major sources are coal combustion, fugitive dust, vehicle exhaust, secondary sulfate and nitrate, and organic matter while biomass burning and construction dust contribute only a small fraction. In addition, source inventory in Beijing is used to determine the primary source contributions. The two methods result in comparable results. Source apportionment at three sampling sites presents similar contributions to PM2.5 although the sites are far away from each other. However, distinct seasonal pattern is presented for the source contributions from coal combustion, fugitive dust, biomass burning, secondary sulfate and nitrate.

  • PDF

Study for Korean Fly Ash Characterization (국내 플라이 애쉬의 품질특성에 관한 연구)

  • 강민호;하재담;김기수;차춘수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04a
    • /
    • pp.95-98
    • /
    • 1998
  • Fly ash is glassy dust collected from coal fired power plant. Recently, much research for fly ash conducted in Korea and fly ash is a valuable material especially when it used in high strength, high flowable, high durability concrete. But it varies with coal source, coal grinding and boiler conditions. Therefore, it is important that quality control of fly ash itself to get high quality concrete. In this study, over 20 samples of Poryong and Samchonpo fly ashs are tested and analyzed. The physical, chemical properties of fly ash and their relationships are investigated and it can be applied to quality control of concrete.

  • PDF

A Study on Occupational Environment Assessment Strategies for Respirable Particulate Matter at Coal-Fired Power Plants (석탄화력발전소 호흡성분진 작업환경 평가 전략 사례에 관한 연구)

  • Eun-Seung Lee;Yun-Keun Lee;Dong-Il Shin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.3
    • /
    • pp.375-383
    • /
    • 2023
  • Objectives: Coal-fired power plants feature diverse working conditions, including multi-layered employment structures and irregular work cycles due to outsourcing and non-standardized tasks. The current uniform occupational environment measurement systems have limitations in accurately assessing and evaluating these varied conditions. This study aims to propose alternative measurement and assessment strategies to supplement existing methods. Methods: Major domestic coal-fired power plants were selected as the study targets. To prepare for the study and establish strategies, work processes were identified and existing occupational environment measurement results were compared and analyzed. The study proceeded by employing three strategies: specific exposure groups (SEGs) measurement, continuous monitoring, and supplementary measurements, which were then compared and discussed. Results: Previous exposure index evaluations (5,268 cases) indicated that crystalline silica, a type of respirable particulate matter, had detection limits below the threshold (non-detectable) in 82.6% (4,349 cases) of instances. Exposures below 10% of the exposure limit were observed at a very low concentration of 96.1%. Similar exposure group measurements yielded results where detection limits were below the threshold in 38.2% of cases, and exposures below 10% of the limit were observed in 70.6%. Continuous monitoring indicated detection limits below the threshold in 12.6% of cases, and exposures below 10% of the limit were observed in 75.6%. Instances requiring active workplace management accounted for more than 30% of cases, with SEGs at 11.8% (four cases), showing a higher proportion compared to 3.0% (four cases) in continuous monitoring. For coal dust, exposures below 10% of the limit were highest in legal measurements at 90.2% (113 cases), followed by 74.0% (91 cases) in continuous monitoring, and 47.0% (16 cases) in SEGs. Instances exceeding 30% were most prevalent in SEGs at 14.7% (five cases), followed by legal measurements at 5.0% (eight cases), and continuous monitoring at 2.4% (three cases). When examining exposure levels through arithmetic means, crystalline silica was found to be 104.7% higher in SEGs at 0.0088 mg/m3 compared to 0.0043 mg/m3 in continuous monitoring. Coal dust measurements were highest in SEGs at 0.1247 mg/m3, followed by 0.1224 mg/m3 in legal measurements, and 0.0935 mg/m3 in continuous monitoring. Conclusions: Strategies involving SEGs measurement and continuous monitoring can enhance measurement reliability in environments with irregular work processes and frequent fluctuations in working conditions, as observed in coal-fired power plants. These strategies reduce the likelihood of omitting or underestimating processes and enhance measurement accuracy. In particular, a significant reduction in detection limits below the threshold for crystalline silica was observed. Supplementary measurements can identify worker exposure characteristics, uncover potential risks in blind spots of management, and provide a complementary method for legal measurements.

Mortality and Morbidity Based on Secondary Data Analysis for Respiratory System Diseases among Residents around Ansim, Daegu, Korea (호흡기계 질환 관련 이차자료에 근거한 대구 안심 지역주민의 사망 및 이환 현황)

  • Min, Young-Sun;Lee, Kwan;Lim, Hyun-Sul;Lee, Duk-Hee;Hong, Nam Soo;Kim, Geun-Bae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.346-354
    • /
    • 2015
  • Objectives: This study was conducted to evaluate the changes and regional differences of mortality and morbidity particularly respiratory system diseases in the area of exposure to coal dust(Ansim area, Dong-gu, Daegu). Methods: The authors analyzed secondary data(cancer registration data, mortality data, and health insurance data) for respiratory system diseases. We calculated age standardized incidence ratio(SIR), mortality ratio(SMR), and health care utilization ratio(SHR) using those data. Results: There were no significant differences between Ansim area(or Dong-gu, Daegu) and the control area for cancer registration data and mortality data. In the results for the health insurance data, significant increased SHR in asthma was observed compared to the control area. Conclusions: Although confounders such as selection bias were not clearly ruled out, our findings reveal increased asthma SHR in the area of exposure to coal dust. Further prospective studies are required to clarify the increasing respiratory disease due to exposure to coal dust.

Analysis of Changes in Power Generation of Each Power Generation Company by the Fine-Dust Seasonal Management System (미세먼지 계절관리제로 인한 발전사별 전력생산량 변화 분석)

  • Kim, Bu-Kwon;Won, Doo Hwan
    • Environmental and Resource Economics Review
    • /
    • v.30 no.4
    • /
    • pp.627-648
    • /
    • 2021
  • The fine-dust season management system refers to the policy of implementing enhanced reduction measures in transportation, power, business and living sectors in winter, when fine dust levels are high. The fine dust season management system is a regulatory policy that causes social costs and transfers to various economic players. Equity is an important issue for the cost burden. Therefore, in this study, the cost of each power generator was analyzed using the coal power generation reduction amount of each power generator to verify that the cost of the power sector is evenly distributed. In particular, the effect of the fine dust season management system on coal power generation of power generators was analyzed by applying a synthetic control method that can identify the time-variable effect of the policy. It was confirmed that the fine dust season management system reduced volume of fuel and power generation in coal power plants, resulting in an increase in the cost of the power generation sector, even considering the effect of some power demand due to the COVID-19 crisis. However, it could be seen that these costs were not distributed equally among the generators, and that they were more costly to the specific generators.Social costs incurred by fine dust season management need to be improved so that stakeholders are equally burdened.

The Logistics Process Analysis of Coal Market (석탄류의 물류 프로세스 분석)

  • Kim, Kyoung-Tae;Kwon, Yong-Jang;Kim, Young-Joo;Lee, Suk
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3299-3305
    • /
    • 2011
  • Railroad is considered a representative echo-friendly mode, but there are many civil complaints due to dusts arising in the process of bulk cargo transportation. The freight station which is handling coal are slowly decreasing because of civil complaints. Generally gondolas and hopper cars kinds of freight cars have a role to carry coal such as anthracite and bituminous coal. The railroad competitiveness in the field of bulk cargo transportation is diminishing because there are cost increase and dust emission in the process of transshipment. In this study, we analysed the logistics process of bulk cargo transportation in the point of railroad and we could draw the problems from the logistics process. The results could be used to study various alternatives to improve the process of coal transportation.

  • PDF