• 제목/요약/키워드: Coagulation system

검색결과 271건 처리시간 0.022초

Seasonal variation of assimilable organic carbon and its impact to the biostability of drinking water

  • Choi, Yonkyu;Park, Hyeon;Lee, Manho;Lee, Gun-Soo;Choi, Young-june
    • Environmental Engineering Research
    • /
    • 제24권3호
    • /
    • pp.501-512
    • /
    • 2019
  • The seasonal effects on the biostability of drinking water were investigated by comparing the seasonal variation of assimilable organic carbon (AOC) in full-scale water treatment process and adsorption of AOC by three filling materials in lab-scale column test. In full-scale, pre-chlorination and ozonation significantly increase $AOC_{P17\;(Pseudomonas\;fluorescens\;P17)}$ and $AOC_{NOX\;(Aquaspirillum\;sp.\;NOX)}$, respectively. AOC formation by oxidation could increase with temperature, but the increased AOC could affect the biostability of the following processes more significantly in winter than in warm seasons due to the low biodegradation in the pipes and the processes at low temperature. $AOC_{P17}$ was mainly removed by coagulation-sedimentation process, especially in cold season. Rapid filtration could effectively remove AOC only during warm seasons by primarily biodegradation, but biological activated carbon filtration could remove AOC in all seasons by biodegradation during warm season and by adsorption and bio-regeneration during cold season. The adsorption by granular activated carbon and anthracite showed inverse relationship with water temperature. The advanced treatment can contribute to enhance the biostability in the distribution system by reducing AOC formation potential and helping to maintain stable residual chlorine after post-chlorination.

조류기인 유기물질의 제브라피쉬에 대한 뇌파측정기반 독성평가 (Electroencephalography (EEG) based Toxicity Test of Algae Organic Matter on Zebrafish)

  • 오세현;장형준;조윤철
    • 한국물환경학회지
    • /
    • 제39권3호
    • /
    • pp.223-230
    • /
    • 2023
  • Harmful algae blooms have become a serious environmental problem in major river basins in Korea. They are known to produce various algal organic matters (AOMs) including intracellular organic matters (IOMs) and extracellular organic matters (EOMs). Generally AOMs cannot be easily removed by coagulation/flocculation process in conventional drinking water plants. AOMs produced by blue-green algae also include various toxins such as Microcystins, Anatoxin-a, and Saxitoxin known to have harmful effects on living organisms in aquatic environment. In this study, toxic effects of EOMs produced by three different algae species (Microcystis sp., Anabaena sp., and Oscillatoria sp.) on zebrafish were investigated using electroencephalography (EEG) recording method, a technology for recording brain activity. Electroencephalographic changes in zebrafish revealed that a low EOM had a negative effect on zebrafish compared to both Anabaena sp. and Oscillatoria sp. at 30 ppm EOM exposures. This result might be due to Microcystins present in EOMs produced by Microcystis sp. As a result of power spectrum density anallysis, exposure to EOMs produced by Microcystis sp. caused a state of vigilance in zebrafish. This EEG based toxicity test can be used to examine effects of harmful materials at low levels on living organisms in an aquatic system.

Epistaxis in dental and maxillofacial practice: a comprehensive review

  • Psillas, George;Dimas, Grigorios Georgios;Papaioannou, Despoina;Savopoulos, Christos;Constantinidis, Jiannis
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권1호
    • /
    • pp.13-20
    • /
    • 2022
  • The lifetime incidence of epistaxis in dental and maxillofacial practice has been reported to be as high as 60% and can be caused by dental implant placement, Le Fort I osteotomy, intranasal supernumerary tooth, odontogenic tumors, blood disorders and maxillofacial trauma. Most epistaxis cases are minor and easily managed with direct compression on the nares for 10 minutes. For more significant or recurrent epistaxis, other techniques might include electrocautery, anterior or posterior nasal packing, or Foley catheter balloon. For patients with refractory epistaxis, cauterization of the sphenopalatine artery under endonasal endoscopy or embolization of the internal maxillary artery should be performed. Epistaxis control is required in patients diagnosed with inherited or acquired bleeding disorders or with drug-induced coagulopathies during dental procedures. In these cases, hemostatic system adjustment and hemostasis achieved by local and adjunctive methods are required. Dentists and maxillofacial surgeons must be aware that the nasal cavity is a potential source of perioperative hemorrhage. Depending on the invasiveness of the dental intervention, preoperative involvement of the hematologist and cardiologist is usually necessary to reverse anticoagulation or to cease anticoagulant therapy.

개심술에서의 자가수혈기(Cell Saver)를 이용한 자가수혈 (Autotransfusion Using Ccell Saver in Cardiac Surgery)

  • 육을수
    • Journal of Chest Surgery
    • /
    • 제28권2호
    • /
    • pp.125-130
    • /
    • 1995
  • Autotransfusion system is a common method of reducing the need of intraoperative and postoperative homologous blood transfusion in cardiac operation. Between August 1991 and August 1993, a series of 51 adults undergoing open heart surgery was selected. Autotransfusion using Cell Saver [COBE Baylor Rapid Autologous Transfusion System was done with homologous blood transfusion in 15 cases [Group II or without homologous blood transfusion in 17 cases [Group III . The other 19 cases were taken without Cell Saver for control [Group I . The shed blood in the operative field, remained blood in the oxygenator after cardiopulmonary bypass, and blood drained from chest tubes in postoperative care were aspirated by means of a locally heparinized collection system. After the salvaged blood was washed and centrifuged, the processed blood subsequently reinfused. Composition of processed blood by Cell Saver was hemoglobin 16.9gm%, hematocrit 49%, RBC 5,140,000/ml, WBC 670/ml, and platelet 30,000/ml. In three group, hemoglobin, hematocrit, and platelet counts were decreased postoperatively, but no significant differences between three group. Postoperatively, the amounts of drainage from chest tubes was 543$\pm$121ml in Group I, 809$\pm$201ml in Group II, and 631$\pm$147ml in Group III. In Group II, there was large amount of drainage compared with Group I [p<0.05 . The amount of homologous blood transfused was 1116$\pm$219 ml in Group I, 791$\pm$183 ml in Group II [p<0.05 . The homologous blood was not transfused in 17 cases [53% with Cell Saver.Preoperative and postoperative, coagulation parameters showed no significant differences between three group. And there was no complication related to Cell Saver. We conclude that the autotransfusion using Cell Saver is effective for reducing the homologous blood transfusion in cardiac surgery.

  • PDF

산소용해수와 미생물제재를 이용한 호소 및 폐쇄수역의 정화기술 (Purification Technology in Closed Water like a Reservoir and Pond using Oxygen Solubilized Device and Standardized Microorganism Culture System)

  • 서성녀;김영택;박철휘
    • 한국물환경학회지
    • /
    • 제21권2호
    • /
    • pp.118-124
    • /
    • 2005
  • The oxygen solubilized device(O.S.D) and standardized microorganism culture system is more efficient than physical and chemical purification techniques in closed water. This study was to determine how the O.S.D and standardized culture system is efficient in purification capacity in closed water based on the lab scale and pilot plant. In the batch test, inducing the quantitative results from pilot plant operation condition, removal efficiency of COD and TN were about 48.3% and 35% respectively, while SS and chlorophyll-a were 94.9% and 68.7%. The pilot plant results showed that suspended solid(SS) and chlorophyll-a removal efficiency were 60% and 59% respectively, due to coagulation characteristics by standardized culture. Total nitrogen(TN) and total phosphorus(TP)showed good effect for the purification of target pond water quality from field data. Additionally, released velocity was determined in control condition of $5.31mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $2486.8mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. Otherwise, phosphate and COD reflux in the aeration and microorganism condition was showed $-9.95mgPO{_4}^{3-}{\cdot}m^{-2}{\cdot}day^{-1}$ and $-397.88mgCOD{\cdot}m^{-2}{\cdot}day^{-1}$. This technology is the most effective not only removal of SS and chlorophyll-a but also control of phosphate and COD release which is very important phenomena in evaluating water quality in closed water like a reservoir and pond.

PVDF 가압식과 PE 침지식 분리막을 결합한 2단 막여과 공정의 성능검토 및 회수율 증대 방안 연구 (Increase of Recovery Ratio by Two Stage Membrane Process (the Pressurized PVDF Membrane Followed by Submerged PE Membrane))

  • 김준현;문백수;장홍진;김진호;김병석
    • 멤브레인
    • /
    • 제23권1호
    • /
    • pp.45-53
    • /
    • 2013
  • 현재 분리막 여과 공정은 정수처리에서 많은 관심을 받고 있다. 하지만, 분리막의 효율적인 운영을 위하여 '혼화/응집(/침전)' 등의 전처리 시설 설치로 인한 부지면적 및 비용증가와 5~10%의 배출수 문제가 추가적으로 발생한다. 그래서 본 연구에서는 전처리 공정 없이 지표수(한강)에 대하여 가압식 PVDF 분리막[(주)에코니티]으로 운전하여 성능을 검토하였으며 그 결과 1년 동안 화학적 세정 없이 여과 flux가 1~2.4 m/d (at $25^{\circ}C$)로 운전되었고, 유입원수의 탁도와 상관없이 분리막 처리수의 탁도는 0.05 NTU 이하로 안정되게 유지되었다. 또한, 회수율 제고를 위하여 1개월 동안 가압식 배출수(역세수 + 배수)를 침지식 PE 분리막[(주)에코니티]으로 연계하여 2단 막여과 운영을 한 결과 전체 공정 회수율을 99.5%까지 증가시킬 수 있었다.

인간조직인자 세포외 부분의 효과적인 제조 방법 (An Efficient Method for Production of Extracellular Human Tissue Factor in Escherichia coli)

  • 유환구;박양진;이우일
    • 생명과학회지
    • /
    • 제19권5호
    • /
    • pp.561-565
    • /
    • 2009
  • 인간조직인자는 혈액응고인자 factor VII 과 복합체를 형성하며 연속적인 혈액응고 연쇄반응을 촉매하는 효소 활성체이다. 복합체 형성에 필수적인 이 조직인자의 세포 외 부분이, 기존의 융합 단백질 및 히스티딘 말단이 없는 새로운 발현 벡터에 의해 대장균 내에서 과량 발현 되었다. 봉입체 형태로 발현된 재조합 인간조직인자는 DEAE-Sephacel 크로마토그라피 기술을 적용하여 분리, 정제 및 구조적 복원이 동시에 시도 되었다. 정제된 재조합 단백질은 SDS-PAGE 분석에서 순수한 형태로 나타났으며, 생물학적 활성도 또한 기존의 조직인자와 거의 동등함을 보였다. 본 연구의 발현 및 정제 시스템은 이전의 보고에서 보여진 방법들에 비해 단백질 분해효소를 사용하지 않아 추가적인 크로마토그라피 과정이 필요 없어 좀 더 효율적이기 때문에 기존의 발현 시스템에 대해 대체할 수 있는 매우 유용한 방법으로 제공된다.

초전도 자기분리에 의한 제지폐수의 정수 (Purification of wastewater from paper factory by superconducting magnetic separator)

  • 하동우;김태형;권준모;손명환;백승규;오상수;하홍수;고락길;김호섭;김영훈;하태욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.342-343
    • /
    • 2009
  • Paper factories use a large amount of water and same amount of wastewater is generated. It is important to purity and recycle the wastewater because of water shortages and water pollution. The existing water treatment facilities like precipitation process need large-scale equipment and wide space to purity the wastewater of paper factory. High gradient magnetic separation (HGMS) system has the merits to purity rapidly because of large voids at filter and to occupy small space. In this paper, two types of superconducting magnets were used for HGMS systems. Cryo-cooled Bi-2223 superconducting magnet system with 70 mm room temperature bore and 200 mm of height was prepared. Cryo-cooled Nb-Ti superconducting magnet with 100 mm room temperature bore and 600 mm of height was used for magnetic separator. Magnetic filters were designed by the analysis of magnetic field distribution at superconducting magnets. The various magnetic seeding reactions were investigated to increase the reactivity of coagulation. The effects of magnetic separation of wastewater were investigated as variation of magnetic field strength and flow rate of wastewater.

  • PDF

Treatment of Rolled Steel Coolant Wastewater by Superconducting High Gradient Magnetic Separation

  • Kim, Tea-Hyung;Ha, Dong-Woo;Oh, Sang-Soo;Kim, Ho-Sup;Ko, Rock-Kil;Lee, Nam-Jin;Kwon, Jun-Mo;Kim, Young-Hun;Kung, Chae-Hun;Ha, Tae-Wook
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.354-354
    • /
    • 2009
  • We have developed the prototypes of superconducting magnetic separation system with high temperature superconductor wire. This separation filter system consist of magnetized matrix SUS430 wire and acrylic frame. This study introduced rolled steel process coolant wastewater applied superconductor HGMS(High Gradient Magnetic Separation). HGMS treatment have acted high efficient method for various wastewater. We have surveyed superconducting magnetic separation technology and reviewed the status of related industries using applied superconductivity. In our basic preliminary experiment using HGMS, it was made clear that the fine para-magnetic particles in the wastewater obtained from rolling process of steel can be separated with high efficiency. We investigated the ability of magnetic flock formation, which used inorganic materials and polymer coagulants. We had a purpose to remove SS of coolant at steel factory. Maximum coagulation remove rate of SS 98%. Removing ratio of $Fe_3O_4$ fine particles in wastewater showed over than 99% in the wastewater containing magnetic fines after four times of repetition of separation.

  • PDF

저가 탄소섬유용 Lignin/Chlorinated Polyvinyl Chloride 블렌딩 섬유의 제조 및 특성 (Preparation and Characterization of Lignin/Chlorinated Polyvinyl Chloride Blended Fibers for Low-cost Carbon Fiber)

  • 조채현;이상오;강다경;홍성화;강찬규;이재웅
    • 한국염색가공학회지
    • /
    • 제32권2호
    • /
    • pp.111-120
    • /
    • 2020
  • In this study, lignin/chlorinated poly(vinyl chloride)(CPVC) blended fibers have been produced for the development of low-cost carbon fiber. Carbon fiber manufacturing was accomplished through stabilization and carbonization process. The lignin/CPVC blended fibers were prepared by wet spinning method. Dimethylacetamid e(DMAc) and cychlohexanone in a ratio of 5:1(wt%) was employed as co-solvent. The ratio of lignin/CPVC was prepared at 0/10, 1/9, 2/8, 3/7, 4/6, and 5/5(wt%). The spinning solution was extruded at a rate of 0.1 to 0.4ml/min according to the blending ratio. The speed of the rollers was the same for all ratios(draw ratio=1). Analysis of fiber cross-section by scanning eletron microscopy(SEM) showed that as the lignin ratio increased in the same coagulation bath and distilled water, the pore size of the spinning fiber decreased. Therefore, the highest tensile strength of the blending fibers was 6.3±1.2MPa at the 5/5 ratio. The carbon fiber also showed the best tensile strength of 120.78±2.43MPa at 5/5 ratio.