• 제목/요약/키워드: Co-flow

검색결과 3,409건 처리시간 0.029초

수평관 내에서 이산화탄소 초임계 가스냉각 과정의 열전달 및 압력강하 특성에 관한 실험적 연구 (An Experimental Study on Heat Transfer and Pressure Drop Characteristics during Supercritical Process of Carbon Dioxide in a Horizontal Tube)

  • 최이철;강병하;김석현
    • 설비공학논문집
    • /
    • 제16권5호
    • /
    • pp.414-420
    • /
    • 2004
  • The heat transfer and pressure drop characteristics associated with the gas cooling of the supercritical carbon dioxide in a horizontal tube have been investigated experimentally. This problem is of particular interest in the design of a gas cooler of cooling systems using $CO_2$refrigerant. The test section is consisted of 6 series of 455 mm in length, 4.15 mm ID copper tube, respectively. The effects of the inlet temperature, pressure and mass flow rate on the heat transfer and pressure drop of $CO_2$in a horizontal tube is studied in detail. The heat transfer coefficient of $CO_2$is varied by temperature, inlet pressure, and mass flow rate of $CO_2$. This has maximum value at near the pseudocritical temperature. The pressure drop is changed by inlet pressure and mass flow rate of $CO_2$. The results have been compared with those of previous work. The heat transfer correlation at the supercritical gas cooling process is also suggested.

수평 microchannel의 $CO_2$ 비등열전달 (Boiling Heat Transfer Characteristics of $CO_2$ in Horizontal Smooth Microchannel)

  • 최광일;;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.241-246
    • /
    • 2007
  • The present paper dealt with an experimental study of boiling heat transfer characteristics of $CO_2$. Heat transfer coefficients of the refrigerant flow inside horizontal smooth microchannel were obtained with inner tube diameter of 0.3mm and length of 300mm. The direct electric heating method was applied for supplying the heat uniformly to the refrigerant. The experiments were conducted with $CO_2$ purity of 99.99%, at saturation temperature of $10^{\circ}C$, mass flux ranges of $300{\sim}900\;kg/m^2s$, and heat flux ranges of $15{\sim}45\;kW/m^2$. While heat transfer coefficient increased with the increase of heat flux in the low quality region, the heat transfer coefficient decreased with the increase of quality in the high quality region. The heat transfer coefficients were compared with seven existing correlations with the Gungor-Winterton's(1986) correlation gave the best prediction. A new corelation to predict the two-phase flow heat transfer coefficient was developed based on the Chen(1966) correlation. The new correlation predicted the experimental data well with a mean deviation of 9.69% and average deviation of -3.03%.

  • PDF

가스 스월버너의 공연비 제어에 관한 연구 (Study on the control of fuel-air ratio ofgas swirl burner)

  • 김인규;김영수;김양호;김경수;김지원
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 1999년도 제19회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.129-138
    • /
    • 1999
  • In this paper, our main issue is that establishing the control procedure of continuous gas flow rate according to combustion fan RPM. For this, first, we decide the optimum operating condition of gas swirl burner through analysis of combustion characteristics - thermal efficiency, combustion efficiency and exhaust gases such as CO, $CO_{2}$, $O_{2}$, $NO_{x}$ and THC. Second, fuel gas flow rate of gas valve is decided with considering excess air ratio and combustion fan RPM is decided by the target of combustion air flow rate. Finally, experimental operating equation is acquired by regression for gas valve and combustion fan. This equation is the control equation of continuous gas flow rate and always gas flow rate is decided by combustion fan operating RPM.

  • PDF

밀폐된 동시 회전 디스크 내의 주기적 유동 교란의 분포 (Distributions of oscillating flow fluctuation in the flow between corotating disks confined)

  • 공대위;주원구
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.392-395
    • /
    • 2006
  • The configuration of coaxial co-rotating contained in shroud provides a useful model for investigating the characteristics of flow in the HDD. Reynolds number is defined as $Re_R={\Omega}{R_o}^2/{\upsilon},\;Re_H={\Omega}R_oH/{\upsilon}$ in present study. An experimental investigation was performed for turbulence profiles and PSD distribution and vortices frequency behavior for various range of $Re_R=2.43{\times}10^4{\sim}3.61{\times}10^5$. A laser Doppler anemometry (LDA) is used to obtain the velocity field of unobstructed co-rotating disks flow. Airflow pattern visualization between inner and outer region was compared with turbulence profiles measured from LDA. Outer detached shear layer and dead-zone without oscillating velocity fluctuation to circumferential mean were quantitively traced.

  • PDF

파퍼형 GIS/GCB의 유동특성 해석 (Flow field Analysis In Puffer Type Interrupters of GIS/GCB)

  • 송기동;신영준;박경업;최영길;송원표;강종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1512-1516
    • /
    • 1994
  • FLIC(Fluid in cell) method has been used for analyzing a cold gas flow field in an interrupter of a circuit treater since 1970s. In this paper FLIC method is applied to calculation of a cold gas flow and then combined with the simple are analysis method in order to investigate the flow field characteristics in a puffer type interrupter rated at 145kV 40kA. The results for a cold gas flow agree with the experimental measurement well. The other results such as pressure rise, arc temperature, post-arc current and so forth am also reasonable and show the possibility that the combined program can be applied to the design of UHV interrupters.

  • PDF

The Effect of Oxygen and Carbon Dioxide Concentration on Soot Formation in Nonpremixed Flames Using Time Resolved LII Technique

  • Oh, Kwang-Chul;Shin, Hyun-Dong
    • Journal of Mechanical Science and Technology
    • /
    • 제19권11호
    • /
    • pp.2068-2076
    • /
    • 2005
  • The influence of oxygen concentration and CO$_{2}$ as diluent in oxidizer side on soot characteristics was studied by Laser Induced Incandescence, Time Resolved LII and Transmission Electron Microscopy photography in non-premixed co flowing flames. Through the comparison of TEM photographs and the decay rate of LII signal, suitable two delay times of TIRE-LII method and signal sensitivity ($\Delta$S$_{TIRE-LII/) were determined. The effects of O$_{2}$ and CO$_{2}$ as diluent in oxidizer side on soot formation are investigated with these calibrated techniques. The O$_{2}$+CO$_{2}$, N$_{2}$, and [Ar+CO$_{2}$] mixture in co-flow were used to isolate CO2 effects systematically. The number concentration of primary particle and soot volume fraction abruptly decrease by the addition of CO$_{2}$ to the co-flow. This suppression is resulted from the short residence time in inception region because of the late nucleation and the decrease of surface growth distance by the low flame temperature due to the higher thermal capacity and the chemical change of CO$_{2}$ including thermal dissociation. As the oxygen concentration increases, the number concentration of soot particles at the inception region increases and thus this increase of nucleation enhances the growth of soot particle.

고정식 소화장치 노즐조건에 따른 $CO_2 $전달특성 (The Characteristics of $CO_2 $ Extinguishant Transfer According to the Nozzle Conditions of a Fixed Eire System)

  • 박찬수;최주석;전철균
    • 한국화재소방학회논문지
    • /
    • 제18권2호
    • /
    • pp.41-48
    • /
    • 2004
  • 선박 기관실의 고정식 소화장치로 사용되는 $CO_2 $ 소화장치의 소화효과에 영향을 미칠 수 있는 인자 중 분사노즐위치를 변화시켜 이산화탄소 소화제 전달특성에 대한 전산모이실험을 3차원 비정상상태로 수행하였다. 노즐위치에 따라 유동장과 $CO_2$ 소화제 농도장을 계산하였다 소화제 분사노즐을 공간의 천장 중앙에 매치 한 경우, 천장에 형성되는 대칭 천장 제트가 대칭면에서 서로 부딪혀 저농도 하향 유동을 발생시켜 분사주위에는 규정농도 이하의 농도분포를 형성시킨다. 벽의 모서리에서는 소화제질량전달이 촉진되는 경향으로 인해 농도곡선은 모서리 부근에서 피크를 나타낸다.

구획화재에서 환기조건의 변화가 화재특성에 미치는 영향 (Part II: 다차원 화재거동) (Effects of Ventilation Condition on the Fire Characteristics in Compartment Fires (Part II: Multi-dimensional Fire Dynamics))

  • 김종현;고권현;박충화;황철홍
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.32-38
    • /
    • 2010
  • 실규모 ISO 9705 표준 화재실에서 환기조건 변화에 따른 다차원 화재거동에 관한 수치해석적 연구가 수행되었다. 선행된 실험과 동일한 조건에 대하여 FDS(Fire Dynamic Simulator)가 사용되었다. 과환기화재 및 환기부족화재의 발생을 위하여 연료 유량과 출입구의 폭이 변화되었다. 주요 결과로서, 환기부족화재의 내부 유동패턴은 과환기화재와 비교할 때 반대방향을 갖으며, 그 결과 다량의 고온 생성물이 구획내부에서 재순환되는 매우 중요한 특징을 확인하였다. 환기조건에 따른 유동패턴의 변화는 구획 내부에서 고온 생성물의 체류시간을 크게 변화시키며, CO 및 그을음의 복잡한 생성과정에 큰 영향을 미칠 수 있다. 환기부족화재는 구획 내부의 열 및 유동구조 뿐만 아니라 화학종의 분포에 관하여 매우 복잡한 3차원 구조를 생성하였다. 특히, 구획 내부의 측면에서 추가적인 반응은 유동패턴 및 CO 생성에 매우 큰 영향을 주고 있다. 복잡한 CO의 분포는 3차원 산소 농도의 분포 및 유동 패턴을 통해 체계적으로 분석되었다. 위 결과로 부터 고온 상층부에서 측정된 국부 화학종 농도는 구획 내부의 화재특성을 규명하는데 많은 한계가 있음을 확인할 수 있었다.

Performance improvement of countercurrent-flow membrane gas absorption in a hollow fiber gas-liquid membrane contactor

  • Ho, Chii-Dong;Sung, Yun-Jen;Chen, Wei-Ting;Tsai, Feng-Chi
    • Membrane and Water Treatment
    • /
    • 제8권1호
    • /
    • pp.35-50
    • /
    • 2017
  • The theoretical membrane gas absorption module treatments in a hollow fiber gas-liquid membrane contactor using Happel's free surface model were obtained under countercurrent-flow operations. The analytical solutions were obtained using the separated variable method with an orthogonal expansion technique extended in power series. The $CO_2$ concentration in the liquid absorbent, total absorption rate and absorption efficiency were calculated theoretically and experimentally with the liquid absorbent flow rate, gas feed flow rate and initial $CO_2$ concentration in the gas feed as parameters. The improvements in device performance under countercurrent-flow operations to increase the absorption efficiency in a carbon dioxide and nitrogen gas feed mixture using a pure water liquid absorbent were achieved and compared with those in the concurrent-flow operation. Both good qualitative and quantitative agreements were achieved between the experimental results and theoretical predictions for countercurrent flow in a hollow fiber gas-liquid membrane contactor with accuracy of $6.62{\times}10^{-2}{\leq}E{\leq}8.98{\times}10^{-2}$.

CFD를 이용한 EPPR 밸브 유동력 특성 분석 및 시뮬레이션 (Simulation of EPPR Valve Flow Force Characteristic using CFD Analysis)

  • 윤주호;윤장원;손호연;김당주;안경관
    • 드라이브 ㆍ 컨트롤
    • /
    • 제14권1호
    • /
    • pp.14-22
    • /
    • 2017
  • Flow force is the additional unbalanced force acting on the valve spool by fluid flow, excluding the static pressure force that is offset on the spool land wall at the same magnitude. When designing the valve spool, it is assumed that the same average value of static pressure is applied to the inlet and outlet spool land wall in one chamber. However, the high velocity of the fluid flow by the inlet or outlet metering orifice creates unbalanced pressure distribution and generates additional force in the opposite direction to that of the solenoid attraction force. This flow force has a negative effect on the control performance of the EPPR valve, which needs to develop uniform output pressure along the entire spool control range. In this study, we developed a 3D model of the EPPR valve and conducted flow force characteristic analysis using CFD S/W (ANSYS FLUENT). The alleviated flow force model was derived by adjusting the design parameters of the spool notch.