• Title/Summary/Keyword: Co-PCBs

Search Result 44, Processing Time 0.018 seconds

A Study on the PCBs-containing Waste Treatment by High Temperature Incineration (고온소각에 의한 PCBs 함유 폐기물처리에 관한 연구)

  • Kim, Seong-Jung;Kim, Dong-Hyuk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.1
    • /
    • pp.88-95
    • /
    • 2009
  • This study is for understanding the domestic possibilities of the high temperature incineration of waste containing Polychlorinated Biphenyls (PCBs) with the analysis of normal operation case and waste gas, fly ash, dioxin about bottom ash, Total-PCBs, Co-PCBs, and the for analysis the heavy metal leaching feature included by bottom ash and fly ash, heavy metal leaching experiment was implemented. The result shows the dioxin density of the waste gas from waste containing PCBs was $0.00699{\sim}0.00763ng-TEQ/Nm^3$, which is lower than $0.0192ng-TEQ/Nm^3$ from the normal operation case. And each Co-PCBs and total PCBs shows $0.00043{\sim}0.00112ng-TEQ/Nm^3$ and $3.06{\sim}3.87ng/m^3$ respectively. The bottom ash test result shows Dioxin 0.00225~0.00630ng-TEQ/g, Co-PCBs 0.00027~0.00082ng-TEQ/g, Total PCBs 0.9~2.6ng/g, and the fly ash shows Dioxin 0.00164~0.00344ng-TEQ/g, Co-PCBs 0.00053~0.00054ng-EQ/g, Total PCBs 0.64~0.84ng/g. The bottom ash and fly ash experiments for heavy metal leaching did not show any leaching but when it comes to the ingredients of the fly ash, Pb elements shows 31.01~237.7ppm, higher than leaching criterion. The analysis of the density of all air pollution material from the waste gas shows the lower value than permissible criterion.

Contamination level and congener profiles of PCBs, Co-PCBs and PCDD/DFs in transformer insulation oil samples (변압기 절연유 중 PCBs, Co-PCBs 및 PCDD/PCDFs 오염수준 및 이성체 분포)

  • Kim, Kyoung-Soo;Kim, Jong-Guk;Shin, Sun-Kyoung;Kim, Kyoung-Sim;Song, Byung-Joo
    • Analytical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.263-271
    • /
    • 2006
  • The levels of total PCBs, Co-PCBs and PCDD/Fs in the transformer insulation oil samples obtained using GC/ECD and HRGC/HRMS were ranged from N.D. to 77.3 ppm, from 0.0863 to 2.49 ppm and from N.D. to 0.00241 ppm, respectively. In terms of WHO-TEQ values, Co-PCBs and PCDD/Fs were ranged from 23.3 to 600 pgTEQ/g and from N.D. to 128 pgTEQ/g, respectively (${\Sigma}Co$-PCBs+PCDD/Fs concentration was calculated 24.4~728 pgTEQ/g). Although, the contribution of PCDD/Fs was below 12% in total TEQ concentration, it is suggested contamination of PCDD/Fs in transformer insulation oils. Among 10 samples, 4 samples showed higher concentration than 2 ppm (specific waste criterion of Korea) and Aroclor 1242, 1248, 1254 and 1260 was detected in samples as a single or mixture of Aroclor. It was shown reliable relationship between concentration of Co-PCBs and those of PCDD/Fs (p<0.003), however, was not shown between production year of transformer and concentration of PCBs. The distribution pattern of Co-PCB congeners showed that the ratios of mono-ortho substituted congeners were higher than non-ortho substituted congeners. Among that, PCB-118 congener was predominant. In addition, the OCDD congener was predominated in PCDD/Fs congeners as above 53%. Moreover, the congener pattern of Co-PCBs was similar to that of Aroclor as well as ambient air, which suggested that PCBs volatilization from transformer insulation oil affected the pattern of Co-PCBs in ambient air.

Thermal Destruction of Waste Insulating Oil Containing PCBs under High Temperature and Pressurized Conditions

  • Seok, Min-Gwang;Lee, Gang-Woo;Lee, Jae-Jeong;Kim, Min-Choul;Kim, Yang-Do;Jung, Jong-Hyeon;Shon, Byung-Hyun
    • Environmental Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.157-165
    • /
    • 2012
  • This experimental study was performed to obtain thermal energy from the combustion of synthetic gas, produced by the pyrolysis of insulating oil containing polychlorinated biphenyls (PCBs) in a high temperature and high pressure reactor. The average synthetic gas generated was $59.67Am^3/hr$ via the steady state gasification of insulating oil waste (20 kg/hr) with average concentrations (standard deviation) of $CO_2$, CO, and $H_2$ in the synthetic gas of $38.63{\pm}3.11%$, $35.18{\pm}1.93%$, and $28.42{\pm}1.68%$, respectively. The concentrations of the PCBs in the transformer insulating oil and synthetic gas after its gasification, and the concentrations of the dioxins that could be produced from the incomplete degradation of PCBs were measured. It was revealed that the PCBs in the insulating oil were composed of the series from tetrachlorobiphenyl to octachlorobiphenyl. However, only the #49, #44, #52, and #47/75/48 congeners were detected from the synthetic gas after gasification of the insulating oil and in the flue gas from the combustor. In conclusion, the experimental conditions suggested in this study were very useful for the appropriate treatment of insulating oil containing PCBs. Also, fuel gas containing CO and $H_2$ can be obtained from the pyrolysis of insulating oil containing PCBs.

Residues of Co-planar PCBs in Ginseng at Environment of North Gyeongbuk (경북 북부 인삼 재배환경 중 Co-planar PCBs의 잔류)

  • Kim, Jung-Ho
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.987-995
    • /
    • 2011
  • Co-planar PCBs(polychlorinated biphenyls) of non-ortho are investigated in soil and ginseng on the North Gyeongbuk with HRGC/HRMS. PCB77 in soil on Yeongju and Sangju are detected 0.0007 pgTEQ/g and 0.0009 pgTEQ/g, respectively. PCB81 in soil on Yeongju and Sangju are detected 0.0113 pgTEQ/g and 0.0108 pgTEQ/g, respectively. Also PCB126 in soil on Yeongju and Sangju are detected 0.0907 pgTEQ/g and 0.0944 pgTEQ/g, respectively. But PCB169 in soil on Yeongju and Sangju is not detected. Total Co-planar PCBs of non-ortho in soil on Yeongju and Sangju are 0.1027 pgTEQ/g and 0.1061 pgTEQ/g, respectively. PCB77 in ginseng on Yeongju and Sangju are detected 0.0008 pgTEQ/g. Then PCB81 in ginseng on Yeongju and Sangju are detected 0.0104 pgTEQ/g and 0.0112 pgTEQ/g, respectively. But PCB126 in ginseng on Yeongju and Sangju are detected 0.0585 pgTEQ/g and 0.0579 pgTEQ/g, respectively. PCB169 in ginseng on Yeongju and Sangju is not detected. Total Co-planar PCBs of non-ortho in ginseng on Yeongju and Sangju are 0.0697 pgTEQ/g and 0.0700 pgTEQ/g, respectively. Relationship of PCBs in between soil and ginseng shown significance($R^2$ : 0.99).

Distribution and Source Identification of PCDD/Fs and Co-PCBs in Sediments from the Geum River (금강 수계 퇴적물 중 PCDD/Fs 및 Co-PCBs의 농도 분포와 발생원 해석)

  • Park, Jong-Eun;Kim, Jong-Guk;Ahn, Sung-Yun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.12
    • /
    • pp.900-906
    • /
    • 2011
  • To investigate concentration and sources of PCDD/Fs and Co-PCBs in sediments, total 52 sediment samples were measured at 17 sites in Geum River. As a result of analysis, total concentrations of PCDD/Fs and Co-PCBs were ranged from not detected (N.D.)~193.47 pg/g-d.w. (mean value: 84.52 pg/g-d.w) and 0.34~359.19 pg/g-d.w (mean value: 114.65 pg/g-d.w.) respectively. Also, toxic equivalent (TEQ) concentration of PCDD/Fs and Co-PCBs were ranged from N.D.~5.12 (mean value: 0.88) pg I-TEQ/g-d.w and N.D.~0.58 (mean value: 0.09) $WHO_{2005}$-TEQ pg/g-d.w. respectively. The upstream indicate the highest concentration and as it goes to the downstream, it has tendency to decrease. Higher chlorinated compounds were dominant in most of site which detected PCDD/Fs. Occurrence of Co-PCBs isomer patterns appear similar to each sampling site was found. The isomer patterns showed similar between sediment and PCB products. The principal component analysis also showed that the samples contained the characteristics of PCBs products.

PCBs 오염토양의 생물학적 처리

  • Na In-Uk;Hwang Gyeong-Yeop;Choi Ji-Won;Kim Seon-Mi;Choi Su-Jin
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.49-53
    • /
    • 2006
  • The possibility of removal of PCBs (Polychlorinated Biphenyls) in soil was studied using biological method. The effects of soil and co-substrate on both PCBs reduction rate and chloride ion concentration in soil were investigated. It was shown that PCBs concentration of all the soils used in this study were reduced from 5ppm to below 1ppm after 60days, also chloride ion concentration in slurry increased, Results showed that leaf mold and humic acid as co-substrate do not seem to be effective for biological treatment of PCBs in soil,

  • PDF

Remediation of Soil Contaminated with Persistent Organic Pollutants through Subcritical Water Degradation (아임계수 분해를 이용한 난분해성 물질로 오염된 토양의 정화 연구)

  • Choi, Jae-Heon;Lee, Hwan;Lee, Cheol-Hyo;Kim, Ju-Yup;Oh, Seok-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.113-119
    • /
    • 2015
  • This study examined remediation of soil contaminated with polychlorinated biphenyls (PCBs) and other persistent organic pollutants by using subcritical water. Our results showed that removal efficiency of PCBs from soil and treatment temperature were linearly proportional under subcritical conditions. The removal efficiency as increased as reacting period increased. PCBs contaminating fine particles in soil were less effectively removed than those in entire contaminated soil. Reaction of the zero-valent iron and PCBs under subcritical condition produced dechlorinated product, where most of the PCBs were oxidised while little remained as dechlorinated. Other organic pollutants, such as TPH, BTEX, TCE/PCE, and chlorpyrifos, were removed by more than 90% at $300^{\circ}C$. Considering removal efficiency and identification of by-products, we suggest that subcritical water treatment may be effectively applied to soils contaminated with various persistent organic pollutants.

PCBs concentration and congener distribution in transformer insulation oil samples using GC/ECD and HRGC/HRMS analysis (GC/ECD와 HRGC/HRMS 분석을 이용한 변압기 절연유 중 PCBs 농도 및 이성체 분포)

  • Kim, Kyoung-Soo;Kim, Hyoung-Seop;Song, Byung-Joo;Jeong, Mi-Jeong;Kim, Jong-Guk;Park, Seok-Un;Shin, Sun-Kyoung
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.232-240
    • /
    • 2005
  • The total PCBs level in the transformer insulation oil samples using GC/ECD and HRGC/HRMS were ranged from 0.087 to $223.6{\mu}g/g$ and ranged from N.D. to $154.04{\mu}g/g$, respectively. The calculated TEQ values were ranged from 0.00067 to 6.8 ng WHO-TEQ/g. Among the samples, 6 samples showed higher than 2 ppm concentration (specific waste criterion of Korea). A variety in the concentration of total PCBs were observed between ECD and HRMS analysis. This is maybe due to quantification mehtod. The Aroclor 1248 wasn't present in the samples. The distribution pattern of Co-PCB congeners showed that the ratio of monoortho substituted congeners were higher than non-ortho substituted congeners. Among that, PCB-167 congener was predominant. In addition, the distribution of Co-PCBs congeners was different with that of flue gas and ambient air samples as well as commercial PCB formulations (Aroclor, Kanechlor).

Static Supercritical Fluid Extraction of PCBs from Soil Matrix (정적 초임계유체 방식에 의한 토양 중의 PCBs 추출)

  • Ryoo, Keon-Sang;Lee, Won-Kyoung;Hong, Yong-Pyo;Oh, In-Gyung;Kim, Yong-Gyun
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.6
    • /
    • pp.578-584
    • /
    • 2003
  • Polychlorinated biphenyls (PCBs) known as environmental contaminants in soil were analyzed by the soil pollution standard process test and the static supercritical $CO_2$ extraction mode. It was shown that the percent average recoveries of PCBs by the soil pollution standard process test were ranged in 25-35% and the corresponding standard deviations were above 10%. In contrast, the percent average recoveries of PCBs by the static supercritical $CO_2$ extraction mode were 2-2.5 times higher and standard deviations were within 7%. These results indicate that static supercritical $CO_2$ extraction mode may be a useful alternative to sample pretreatment certified by the soil pollution standard process test. The increasing supercritical $CO_2$ pressure from 1130 psi to 1996 psi at $40^{\circ}C$ enhanced the recovery of all PCB congeners from soil. However, at same Tc and Pc, the equilibrium time (5 versus 60 minutes) had no effect on the recovery of each PCB congener. Finally, similar PCB recoveries were obtained under the same extraction condition, regardless of the molecular weight and structure (coplanar versus non-coplanar) of PCB congeners.

Analyzing Co-planar PCBs in Food by HRGC/HRMS with Isotopic Dilution Method (동위원소희석법 HRGC/HRMS에 의한 식품 중 Co-planar PCBs 분석)

  • Choi, Dongmi;Suh, Junghyuck;Kim, Minjung;Hong, Mooki;Kim, Changmin;Song, Insang
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.325-332
    • /
    • 2003
  • To analyze co-planar PCBs in food, the isotopic dilution method by high resolution gas chromatography/high resolution mass spectrometry was applied. Among 209 PCB congeners, 12 congeners (#77, #81, #126, #169, #105, #114, #118, #123, #156, #157, #167 and #189) were chosen as target compounds that were toxic congeners re-assessed by WHO in 1998. Milk and milk products including cheese and butter were collected as food samples. Samples were homogenized, spiked with the known amount of the standard mixture and extracted. After extraction, extracts were cleaned up by sulfuric acid impregnated silica gel, purified on silica gel and alumina column chromatography and then analyzed by HRGC/HRMS. As results, the overall recoveries were ranged from 83% to 106% and the limit of detection was about 0.1 pg/g at signal/noise>3. Levels of targets in the selected food samples were 0.001~0.107 pgWHO-TEQ/g.