• Title/Summary/Keyword: Co-60 ${\gamma}-radiation$

Search Result 344, Processing Time 0.028 seconds

Production of Food and Fodder Yeasts from Seaweed (해조(海藻)를 이용한 효모제조(酵母製造)에 관한 연구)

  • Cho, Han-Ok;Rhee, Chong-Ouk;Chae, Soo-Kyu
    • Korean Journal of Food Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.101-107
    • /
    • 1973
  • 1) For the purpose of preparation of food and fodder yeasts from nonedible seaweed, two suitable Candida yeasts have been isolated from seaweed compost. 2) They had the ability of fermenting galactose, sucrose and glucose, and could not ferment maltose and mannit, but could assimilate mannit. 3) NaCl concentration from 1 to 2% had no remarkable effect on growth of yeast and the optimum pH was $4{\sim}5$. 4) In the acid hydrolyzate of brown seaweed (Ecklonia cava Kjellman, Sargassum fulvellum AGARDH) an amorphous deposit was produced during storage after neutralization of media and its removal always delayed yeast growth, but addition of $(NH_4)_2SO_4$ and $NaH_2PO_4$ to media could increase the assimilation of reducing sugar and yeast yield. 5) $Co^{60}$ gamma ray irradiation (dose rate : 1 Mrad/hr, BNL shipboard irradiator) of seaweed had not so much effect on the hydrolysis of carbohydrates and nitrogen compounds in seaweed but could increase the yeast production from seaweed hydrolyzate. 6) The yeast yield was $7{\sim}8$ g of dry yeast per 100 g of seaweed by cultivation with jar fermentor.

  • PDF

The Ethanol Extract of Red Ginseng Enhances Anti-Tumor Effects Using Co60 Gamma Irradiation (홍삼의 에탄올 추출물의 감마선 조사를 통한 항암효과 증대)

  • Hur, Jung-Mu;Kim, Dong-Ho
    • Journal of Applied Biological Chemistry
    • /
    • v.54 no.1
    • /
    • pp.15-20
    • /
    • 2011
  • Red ginseng is one of the most popular traditional medicines in Korea. In this study, we developed a new technique in which ethanol extract of $\underline{r}$ed $\underline{g}$inseng (HRG) was exposed to the $Co^{60}$ gamma radiation ranging from 1~5 kGy. The irradiated HRG (IHRG) were analyzed by high performance liquid chromatography (HPLC) to determine any compositional changes of ginsenosides due to irradiation. No appreciable difference was observed in the HPLC pattern of ginsenosides of HRG. Using MTT assay, the cytotoxicity effect was significantly increased by IHRG compared to HRG. The $LD_{50}$ concentration was $30{\mu}g/mL$ for IHRG-1 (1 kGy), and $15{\mu}g/mL$ for IHRG-5 (5 kGy). The evidences of apoptosis, such as nuclei cleavage and Annexin V staining, were observed in the human prostate cancer PC-3 cells treated with the IHRG. Additionally, the level of reactive oxygen species (ROS) was apparently elevated by IHRG. We also studied the inhibitory effect of IHRG on the growth rate of tumor xenografts in BALB/c male mice. The tumor growth rates were inhibited by 56.9 and 76.1% in mice treated with 10 mg/kg of IHRG-1 and IHRG-5, respectively, compared with control group (21.1%). These results suggest that some biologically active and soluble components in HRG can be more effectively enhancement of anti-tumor effects using irradiation.

A closer look at the structure and gamma-ray shielding properties of newly designed boro -tellurite glasses reinforced by bismuth (III) oxide

  • Hammam Abdurabu Thabit;Abd Khamim Ismail;N.N. Yusof;M.I. Sayyed;K.G. Mahmoud;I. Abdullahi;S. Hashim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1734-1741
    • /
    • 2023
  • This work presents the synthesis and preparation of a new glass system described by the equation of (70-x) B2O3-5TeO2 -20SrCO3-5ZnO -xBi2O3, x = 0, 1, 5, 10, and 15 mol. %, using the melt quenching technique at a melting temperature of 1100 ℃. The photon-shielding characteristics mainly the linear attenuation coefficient (LAC) of the prepared glass samples were evaluated using Monte Carlo (MC) simulation N-particle transport code (MCNP-5) at gamma-ray energy extended from 59 keV to 1408 keV emitted by the radioisotopes Am-241, Ba-133, Cs-137, Co-60, Na-22, and Eu-152. Furthermore, we observed that the Bi2O3 content of the glasses had a significantly stronger impact on the LAC at 59 and 356 keV. The study of the lead equivalent thickness shows that the performance of fabricated glass sample with 15 mol.% of Bi2O3 is four times less than the performance of pure lead at low gamma photon energy while it is enhanced and became two times lower the perforce of pure lead at high energy. Therefore, the fabricated glasses special sample with 15 mol.% of Bi2O3 has good shielding properties in low, intermediate, and high energy intervals.

Determination of the Phantom Scatter Factor ($S_P\;Factor$) using a small Block in the Phantom (작은 블럭을 이용한 판톰 내에서의 판톰 산란 인자(Sp Factor)측정법)

  • Yi Byong Yong;Hong Seok Min;Kim Jae Sung;Choi Eun Kyung;Chang Hyesook;Lee Myung Za;Chun Ha Chung
    • Radiation Oncology Journal
    • /
    • v.10 no.1
    • /
    • pp.121-123
    • /
    • 1992
  • New measurement method for $S_{p}$ factors (Phantom Scatter Factors) is presented. The theoretical development of the approach is disscused showing that $S_{p}$ factors can be obtained from three measurements of ionnization in a blocked, reference field and open field. This method has been tested using $^{60}Co$ gamma rays. The results were within 1% deviation between the theory and the experiment for the $S_{p}$ factor. The new method does not need air measurement, and we could could determine the $S_P$ factors with a small piece of block

  • PDF

Biological Control of Pythium Root Rot by Radiation Induced Mutant, Bacillus lentimorbus WJ5a17 (방사선유도 돌연변이체 Bacillus lentimorbus WJ5a17에 의한 Pythium Root rot의 방제)

  • 이영근;김재성;장병일;장유신;이호용
    • Korean Journal of Environmental Biology
    • /
    • v.21 no.3
    • /
    • pp.276-285
    • /
    • 2003
  • To control pythium root rot, Bacillus lentimorbus WJ5a17 with high anti-fungal activity against Pythium ultimum was induced from B. lentimorbus WJ5 by gamma radiation ($^{60}Co$). The biocontrollers of FWJ5 and FWJ5a17 were formulated ($1.0\times 10^{11}$) with B. lentimorbus WJ5 and WJ5a17, respectively, The population density of FWJ5 and FWJ5a17 maintained highly up to $1.0\times 10^{9}$ CFU $g^{-1}$ in nursery and field soils until 30 days after treatment. P. ultimum spores germination were inhibited 71.0% and 81.4% by FWJ5 and FWJ5a17, respectively. Pythium root rot of yea pepper, Chinese cabbage and radish were significantly (p < 0.05) controled by one time treatment of FWJ5 and FWJ5a17.

Anneal Characteristics of LiF:Mg,Cu,Na,Si Teflon TLDs (LiF:Mg,Cu,Na,Si Teflon TLD의 열처리 특성)

  • Nam, Young-Mi;Chung, Woon-Hyuk;Lee, Dae-Won;Kim, Hyun-Ja;Kim, Gi-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.135-141
    • /
    • 1997
  • The study of anneal characteristics is important for TL dosimeter to reuse. To obtain the annealing condition of the recently developed, new TL dosimeter, LiF:Mg,Cu,Na,Si Teflon Tills in a disk type (diameter 4.5 mm, thickness about $90mg/cm^2$), we studied for pre-irradiation annealing, readout procedure and post-readout annealing, in order. The gamma irradiations were carried out with a $^{60}Co$, dose of 0.1 Gy. We have used the method that observe the variation of thermoluminescent(TL) intensity of these Teflon TLDs over repeated cycles by changing both anneal temperature and anneal time with the TLD reader and the oven. There is a 5% loss in sensitivity over the ten repeated readouts by the annealing condition:pre-irradiation annealing at $80^{\circ}C$ for one hour, readout to $280^{\circ}C$ and post-readout annealing at $270^{\circ}C$ for 20 seconds.

  • PDF

Quality Correction for Ir-192 Gamma Rays in Air Kerma Strength Dosimetry Using Cylindrical Ionization Chambers (원통형 전리함을 이용한 Ir-192 선원에 대한 공기커마세기 측정 시 선질보정에 관한 연구)

  • Jeong, Dong-Hyeok;Kim, Jhin-Kee;Kim, Ki-Hwan;Oh, Young-Kee;Kim, Soo-Kon;Lee, Kang-Kyoo;Moon, Sun-Rock
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.30-36
    • /
    • 2009
  • The quality correction in the air kerma dosimetry for Ir-192 using farmer type ionization chambers calibrated by Co-60 quality is required. In this study we determined quality factor ($k_u$) of two ionization chambers of PTW-N30001 and N23333 for Ir-192 source using dosimetric method. The quality factors for energy spectrum of microSelectron were determined as $k_u$=1.016 and 1.017 for PTW-N30001 and N23333 ionization chambers respectively. We applied quality factors in air kerma dosimetry for microSelectron source and compared with reference values. As a results we found that the differences between reference air kerma rate and measured it with and without quality correction were about -0.5% and -2.0% respectively.

  • PDF

Effects of High Dose Irradiation on The Leukocyte Life Span (고선양(高線量) 방사선(放射線)이 백혈구(白血球) 수명(壽命)에 미치는 영향(影響))

  • Koh, Joo-Hwan;Chong, In-Yong;Kim, Yong-Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.67-75
    • /
    • 1984
  • As a part of studies on acute effects of high dose irradiation the present report was carried out to evaluate the changes of the leukocyte life span in the Newzealand white male rabbits by a single whole body exposure to gamma rays from $^{60}Co$ teleirradiation unit. The exposure was done in dose levels of 100, 300, 550 and 1,000 rad to each experimental group of 10 rabbits. The life span and apparent half survival time of leukocytes, and the elution rate of leukocytes in the circulating blood were measured by McMillan method using $^{51}Cr$. 1. As a critical indicator of radiation hazards of the Newzealand male rabbits, the LD 50/30 and LD 100/30 after whole body exposure was estimated as 550 and 1,000 rads respectively. 2. The life span of leukocyte in the circulation after irradiation was slightly shortened in the 100 rad irradiated group, as compared with the unirradiated control group, but markedly shortened in the 300, 550 and 1,000 rads irradiated group. 3. After irradiation, decrease of leukocyte half survival time in the circulation showed the same pattern as that of leukocytes life span. 4. As the irradiation doses increased, the elution rate of $^{51}Cr$ loss from $^{51}Cr$ tagged leukocytes in the circulation were markedly increased gradually. 5. The life span shortening of leukocytes in the circulation after irradiation seems to occure by two processes of senescence acceleration and early destruction.

  • PDF

Radionuclide identification based on energy-weighted algorithm and machine learning applied to a multi-array plastic scintillator

  • Hyun Cheol Lee ;Bon Tack Koo ;Ju Young Jeon ;Bo-Wi Cheon ;Do Hyeon Yoo ;Heejun Chung;Chul Hee Min
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3907-3912
    • /
    • 2023
  • Radiation portal monitors (RPMs) installed at airports and harbors to prevent illicit trafficking of radioactive materials generally use large plastic scintillators. However, their energy resolution is poor and radionuclide identification is nearly unfeasible. In this study, to improve isotope identification, a RPM system based on a multi-array plastic scintillator and convolutional neural network (CNN) was evaluated by measuring the spectra of radioactive sources. A multi-array plastic scintillator comprising an assembly of 14 hexagonal scintillators was fabricated within an area of 50 × 100 cm2. The energy spectra of 137Cs, 60Co, 226Ra, and 4K (KCl) were measured at speeds of 10-30 km/h, respectively, and an energy-weighted algorithm was applied. For the CNN, 700 and 300 spectral images were used as training and testing images, respectively. Compared to the conventional plastic scintillator, the multi-arrayed detector showed a high collection probability of the optical photons generated inside. A Compton maximum peak was observed for four moving radiation sources, and the CNN-based classification results showed that at least 70% was discriminated. Under the speed condition, the spectral fluctuations were higher than those under dwelling condition. However, the machine learning results demonstrated that a considerably high level of nuclide discrimination was possible under source movement conditions.

Preparation of $BaSO_{4}$ : Eu-PTFE TLD Radiation Sensor and Its Physical Characterstics ($BaSO_{4}$ : Eu-PTFE TLD 방사선 센서의 제작과 물리적 특성)

  • U, Hong;Kim, S.H.;Lee, S.Y.;Kang, H.D.;Kim, D.S.
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.59-66
    • /
    • 1992
  • To develop the highly sensitive TLD radiation sensors, $BaSO_{4}$ : Eu-PTFE TLDs are fabricated by polymerizing the PTFE(polytetrafluoroethylene) with $BaSO_{4}$ : Eu TL phosphors. The $BaSO_{4}$ : Eu TL phosphors having the highest sensitivity of $X/{\gamma}$-rays are obtained by sintering at $1000^{\circ}C$ in $N_{2}$ atmosphere a mixture of $BaSO_{4}$ powder with 1mol% Eu($Eu_{2}O_{3}$), 6mol% $NH_{4}Cl$ and 5mol% $(NH_{4})_{2}SO_{4}$ which were co-precipitated in dilute sulfuric acid and then dried. The activation energy, frequency factor and kinetic order of $BaSO_{4}$ : Eu TL phosphor are 1.17eV, $3.6{\times}10^{11}/sec$ and 1.25, respectively. And the spectral peak of $BaSO_{4}$ : Eu is about 425nm. The optimum TL Phosphor content and thickness of the $BaSO_{4}$ : Eu-PTFE TLD are 40wt% and $105.7mg/cm^{2}$. The optimum polymerization temperature and time for fabrication of $BaSO_{4}$ : Eu-PTFE TLDs are $380^{\circ}C$ and 2 hours in air, respectively. The linear dose range to ${\gamma}$ rays is 0.01-20Gy and fading rate is about 10%/60hours.

  • PDF