• 제목/요약/키워드: Closed ventilation type

검색결과 17건 처리시간 0.021초

압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가 (Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss)

  • 박유미;김락우;김준규
    • 한국농공학회논문집
    • /
    • 제65권1호
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.

전투기 후류처리용 엄체호 최적설계에 관한 연구 (A Study on Optimal Design of the Fighter Igloo Diffuser)

  • 윤용현
    • 한국항공운항학회지
    • /
    • 제18권4호
    • /
    • pp.86-91
    • /
    • 2010
  • New Design configurations of the fighter aircraft igloo diffuser were studied based on the closed ventilation type in contrast to the conventional open distribution type. To validate the enhanced and safe performance, the exhaust flow patterns of the two igloo diffuser types were simulated by both experimental and computational approaches as design tools. Flow visualizations were conducted to investigate the exhaust flow patterns in experimental approach. In addition, the commercial code called Fluent was used to calculate flow field properties. Computational simulations provided detailed parametric studies that significantly reduced the amount of experimentation necessary to alter the design parameters of the existing fighter igloo diffuser. The closed ventilation type of the igloo diffuser was shown the better results.

Effects of Nutrient Solution Application Methods and Rhizospheric Ventilation on Vegetative Growth of Young Moth Orchids without a Potting Medium in a Closed-Type Plant Factory

  • Min, Sang Yoon;Oh, Wook
    • 인간식물환경학회지
    • /
    • 제23권5호
    • /
    • pp.545-554
    • /
    • 2020
  • Background and objective: Moth orchids in the vegetative stage are suitable for a multi-layer growing environment in a closed-type plant factory which can be a good alternative that can reduce production costs by reducing cultivation time and energy cost per plant. This study was conducted to find out the optimal rhizospheric environment for different irrigation methods without a potting medium and rhizospheric ventilation for the vegetative growth of young Phalaenopsis hybrid 'Blanc Rouge' (P. KV600 × P. Kang 1) and Phalaenopsis Queen Beer 'Mantefon' in a closed-type plant factory system. Methods: The one-month-old clonal micropropagules with bare roots rapped with a sponges were fixed on the holes of styrofoam plates above growth beds, and were watered using the ebb-and-flow (EBB) and aeroponic (AER) methods with Ichihashi solution (0.5 strength) once a day at 06:00 (P) or 18:00 (S), and both (PS). Rhizospheric ventilation (V) was also applied to change the temperature, relative humidity, and CO2 concentration of the beds. Plants potted into sphagnum moss and watered once a week were used as the control group. Results: After 12 months of treatment, the growth characteristics of the EBB groups were the best among the treatment groups without a medium, but no effect of irrigation timing was observed. V reduced the temperature, relative humidity and CO2 concentration of the beds. Whereas, EBB+V (ebb-and-flow with ventilation) improved plant growth and reduced the occurrence of disorders and withering. Especially, EBB+V showed a similar performance to the control group. Conclusion: The results indicated that the optimal irrigation method without a potting medium for producing middle-aged potted moth orchids was the EBB system with forced rhizospheric ventilation. Therefore, further studies on the optimal ventilation method and moisture control of the crown need to be carried out to develop the irrigation system without a potting medium for vertical farming in closed-type plant factories.

폐교를 활용한 노인복지시설의 평면유형개발에 관한 연구 - 충북지역을 중심으로 - (A Study on the Development of Plan Types of Elderly Welfare Facility Using Closed Schools - In Case of Chungbuk Province -)

  • 김학래
    • 한국농촌건축학회논문집
    • /
    • 제21권1호
    • /
    • pp.45-52
    • /
    • 2019
  • Since 1980's, Countless schools across the nation, particularly in rural areas, have been closed down by the large fall in number of students. Otherwise, an elderly population has been increasing rapidly, so the demand for welfare services for the elderly population is also increasing. However, the supply of elderly welfare facilities remains inadequate. The purpose of this study is to propose remodelling plan of elderly welfare facility using Closed schools. The result of this study were as follows; in unit-based facility plans, Single room type can be used for elder who lives alone or an elderly couple. Senior Congregate Housing type can be used for four to five people. These two types have equal sunlight and ventilation conditions for each room, and are for an old man in relatively good health. Membership resort type is for the healthy senior who lives in the rural area or lives in the city who wants short-term residence. In case of a Nursing home type, the existing one-sided corridor was converted into a central corridor and each classroom is divided into four rooms. This type has advantage for nursing and management, on the other hand, the corridor is narrow and each room has differences for sunlight and ventilation.

제연용 송풍기의 방염성능 시험장치 설계 (Design of performance testing device for heat exhaust ventilation fan)

  • 이영모;김광용;이재엽;정현종
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.367-372
    • /
    • 2005
  • This study primarily is concerned with a new device which has been developed following the international standards to measure the ventilation performance at elevated temperature. This device can measure duration of ventilation, performance of electricity, static pressure at elevated temperature and also it is having provision to measure reversible performances during fire hazards. Invented device is closed circuit type system which is best suited for korean industrial environment with low cost and high efficiency. International standards has been compared and performance testing has been major using BS 7346 which is tested by Warrington Fire Research Centre.

  • PDF

수/자동 개폐식 환풍기 조립공정개선을 위한 생산성 향상에 관한 연구 (A Study for Productivity Progress of Assembly Process Improvement for manu/auto open and closed type air-machine)

  • 정영득;박주식;오지영;강경식
    • 대한안전경영과학회지
    • /
    • 제3권3호
    • /
    • pp.107-116
    • /
    • 2001
  • The purpose of this paper is to solve the problem that is occuring in assembly process and to progress the productivity by process analysis methods for manu-open and closed model(DWV-20/25DRG), and auto-open and cloesd model(DWV-20/25/DRA)-ventilation fan. Also, this paper is studied by data of 'D' company's product.

  • PDF

사이클론 오일분리 장치 형상변화에 따른 유동 및 오일분리 성능에 관한 해석적 연구 (A Numerical Analysis of Flow Characteristics and Oil Separation Performance for Cyclone Oil Separator Designs)

  • 조용석;이성욱;우근섭;윤여빈;박영준;이덕영;김현철;나병철
    • 한국자동차공학회논문집
    • /
    • 제16권5호
    • /
    • pp.22-28
    • /
    • 2008
  • A closed type crankcase ventilation system has been adopted to engines to prevent emission of blow-by gas to atmosphere. In the early closed type crankcase ventilation system, blow-by gas which contains engine lubricating oil is re-circulated into the intake system. The blow-by gas containing oil mist leads to increased harmful emissions and engine problems. To reduce loss of the engine oil, a highly-efficient oil separation device is required. Principle of a cyclone oil separator is to utilize centrifugal force in the separator and, therefore, oil separator designs depend on rotational flow which causes the centrifugal force. In this paper, flow characteristics and oil separation performances for cyclone type designs are calculated with CFD methodology. In the CFD model, oil particle was injected on a inlet surface with Rosin-Rammler distribution and uniform distribution. The major design parameters considered in the analysis model are inlet area, cone length and outlet depth of the oil separator. As results, reducing inlet area and increasing cone length increase oil separation performance. Changes in outlet depth could avoid interference between rotational flow and outlet flow in the cyclone oil separator.

자연환기장치가 적용된 공동주택의 기밀 및 공기유동 성능 실측 연구 (A Study of Measurement on Airtightness and Air-Flow Performance of Apartment Housing Adopting Window Frame-Type Natural Ventilation)

  • 전주영;김길태;김선동
    • 토지주택연구
    • /
    • 제5권4호
    • /
    • pp.325-332
    • /
    • 2014
  • 본 연구에서는 창문형 자연환기장치가 설치된 7개 세대의 소형공동주택($33m^2{\sim}51m^2$)을 대상으로 Blower Door를 이용한 현장 기밀성능 및 공기유동 성능을 측정하였다. 창문형 자연환기장치는 외기에 면하는 모든 창호 및 거실분합문에 설치되어 있으며, 수동 개폐형 장치가 설치되어있다. 본 연구에서는 자연환기장치와 창호의 개폐여부에 따라서 6개의 CASE를 설정하여 실측하였다. 측정결과, 자연환기장치와 모든 개구부를 밀폐한 상태의 기밀성능 값(CASE1)은 1.77~3.12ACH로 평균 2.27ACH로 나타났으며, 문헌조사 결과 자연환기장치가 설치되지 않은 일반 공동주택(1.65~4.28ACH)과 유사하게 나타났다. 내외측의 자연환기장치를 모두 열었을 때의 공기유동성능 값(CASE6)은 평균 5.87ACH로 나타나 밀폐조건과 비교하여 평균 3.6ACH가 증가하는 것으로 나타났다. 외측 환기장치와 창호를 밀폐한 조건에서 내측 환기장치만 개방시와 내측창을 개방시의 공기유동성능값의 차이는 평균 0.29ACH로 내측창호 개방시의 기밀성능 값이 높게 나타났다. 반대로 내측 환기장치와 창호를 밀폐한 조건에서 외측 환기장치만 개방시와 외측창 개방시의 차이는 평균 0.30ACH로 외측창호 개방시가 높게 나타났다. 내측창호만의 공기유동성능과 외측창호만의 공기유동성능 측정값의 차이는 0.77ACH로 내측창호가 더 우수하게 나타났다. 향후에는 자연환기장치와 창호 및 새시의 종류에 따른 기밀성능의 추가 측정을 통해 정량적 상관관계 조사가 필요할 것으로 판단된다.

대형공간환기용 축류팬에 사용되는 밀폐형 모터의 열신뢰성 분석 (Thermal Reliability Analysis of a Closed Type Motor in an Axial Fan for the Large Space Ventilation)

  • 이태구;허진혁;문선애;유호선;문승재;이재헌
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.494-499
    • /
    • 2007
  • The thermal reliability of the closed-type BLDC motor for the high speed axial fans is analyzed by a numerical method in this dissertation. Since the module and the motor part are combined in a closed case, the heat generated from a rotor in the motor and the electronic components in the PCB module can not be effectively removed to the outside. Therefore the module will easily fail by high temperature. The accelerated-life testing was accomplished to formulate the life equation and numerical method is used to predict the inside temperature of the PCB module, which is one of the life equation parameter according to the environment. The experiment for measuring the surface heat flux of the electronic components is carried out to apply the boundary condition of numerical study. When the environment temperature of BLDC motor is 21, 35 and $50^{\circ}C$, the temperature in the PCB space is predicted as 73.4, 87.5 and $102.4^{\circ}C$. Then the life time with the temperature are calculated as 2,239, 863 and 328.

  • PDF

F-15K 엄체호 분사구 최적 설계에 관한 연구 (DESIGN AND OPTIMIZATION STUDY ON THE F-15K IGLOO DIFFUSER)

  • 윤용현;김성초;조환기;이상현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.66-69
    • /
    • 2009
  • New design configurations were developed based on the closed ventilation type igloo nozzle in contrast to the conventional open distribution type. To validate the enhanced performance, the prediction of the exhaust flow patterns of the igloo diffuser was carried out by both experimental and computational simulations. CFD provided detailed parametric studies that significantly reduced the amount of experimentation necessary to alter the design of existing the F-15K igloo exhaust diffuser.

  • PDF