• 제목/요약/키워드: Closed system and Open system

검색결과 514건 처리시간 0.032초

Relation Between the Repulsive Interaction and the Overlap of the Electron Densities$^\dag$

  • Heo, Hoon;Shin, Kook-Joe;Kim, Yung-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • 제10권3호
    • /
    • pp.238-242
    • /
    • 1989
  • The relations between the repulsive interactions and the electron density overlaps are investigated for various closed shell-closed shell pairs, including the systems containing alkali and halide ions. It is found that the repulsive interaction($V_{rep}$) depends on the overlap of the electron density($S_{\rho}$) according to a simple exponential relation, $V_{rep}$ = $As_{\rho}\;^{\alpha}$. Furthermore, for most of the closed shell systems the $\alpha$ values are near unity and the A values do not vary much. The same tests are also performed for the open shell-closed shell, and the open shell-open shell pairs. Although the results for these systems also show exponential dependences of the repulsive interactions on the density overlaps, the details of the dependence differ greatly from those for the closed shell systems and also vary widely from one individual system to another.

Effects of pressure during the synthesis of petroleum pitch precursors in open and closed systems

  • Choi, Jong-Eun;Ko, Seunghyun;Kim, Jong Gu;Jeon, Young-Pyo
    • Carbon letters
    • /
    • 제25권
    • /
    • pp.95-102
    • /
    • 2018
  • We examined the pressure effects on petroleum pitch synthesis by using open and closed reaction systems. The pressure effects that occur during the pitch synthesis were investigated in three pressure systems: a closed system of high pressure and two open systems under either an atmosphere or vacuum. A thermal reaction in the closed system led to the high product yield of a pitch by suppressing the release of light components in pyrolysis fuel oil. Atmospheric treatment mainly enhanced the polymerization degree of the pitch via condensation and a polymerization reaction. Vacuum treatment results in a softening point increase due to the removal of components with low molecular weights. To utilize such characteristic effects of system pressure during pitch preparations, we proposed a method for synthesizing cost-competitive pitch precursors for carbon materials. The first step is to increase product yield by using a closed system; the second step is to increase the degree of polymerization toward the desired molecular distribution, followed by the use of vacuum treatment to adjust softening points. Thus, we obtained an experimental quinoline insolubles-free pitch of product yield over 45% with softening points of approximately $130^{\circ}C$. The proposed method shows the possibility to prepare cost-competitive pitch precursors for carbon materials by enhancing product yield and other properties.

pH와 산화환원전위에 따른 상등수-퇴적물에서의 인 형태 변화 (Speciation of Phosphorus Dependent upon pH and Oxidation Reduction Potential in Overlying Water and Sediment)

  • 정우혁;김건하
    • 대한환경공학회지
    • /
    • 제28권5호
    • /
    • pp.472-479
    • /
    • 2006
  • 퇴적물로부터 오염물질 용출은 상등수 수질에 많은 영향을 미친다. 본 연구에서는 pH와 산화환원전위에 따른 상등수 및 퇴적물의 인 존재형태의 변화를 관찰하였다. 상등수가 순환되어 호기성 상태를 유지하는 경우, 성층현상으로 인하여 혐기성을 띠는 경우, 퇴적물 상부에 모래 캡핑이 포설된 상태에서 혐기성을 띠는 경우 등 3가지 경우를 가정하여 상등수의 인 형태별 농도를 측정하였다. 퇴적물에서 인 용출은 상등수가 산성일 경우 증가하였으며, 캡핑은 인 용출량을 저감시키고, $PO_4-P$의 용출을 지연시키는 효과가 있는 것으로 나타났다. 상등수와 퇴적물이 혐기성일 때 상등수의 pe/pH가 인이 apatite 상태로 안정하게 존해하는 범위에서 상등수의 인농도는 감소하여 일정한 농도를 나타냈다. 세개의 칼럼에서 최종 평균 인 농도는 순환칼럼에서 0.223 mg/L, 비순환칼럼에서 0.342 mg/L, 캡핑칼럼에서 0.184 mg/L로 캡핑된 칼럼에서 가장 낮게 나타났다. 성층현상에 의해 수질이 악화될 수 있는 호소에 캡핑을 활용할 경우 퇴적물에 의해서 상등수의 인 농도를 감소할 수 있을 것으로 기대된다.

An Experimental Application of Observer/controller Identification Algorithm to the System Identification of Inherently Unstable Systems

  • Park, Mun-Soo;Yang, Dong-Hoon;Hong, Suk-Kyo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.63.4-63
    • /
    • 2002
  • $\textbullet$ Closed System Identification for inherently unstable systems $\textbullet$ Application of Observer/controller Identification (OCID) algorithm to those systems $\textbullet$ An open-loop system model with corresponding controller and observer gains are identified using OCID $\textbullet$ Experimental example of the OCID algorithm for an inverted pendulum system operating in closed-loop $\textbullet$ Modal analysis and time response to the added distrubance are presented to evaluate the performance of the OCID algorithm.

  • PDF

Present Research Status of MHD Electrical Power Generation

  • Shioda, Susumu
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.3-8
    • /
    • 1989
  • Recent research activities for open and closed cycle MHD electrical power generations are reviewed. World first full scale 500MWe natural gas fired open cycle MHD is now under construction in USSR. Coal-fired open cycle MHD researches are in the stage of proof of concept and retrofitting of old coal power stations with MHD is planned in US and other countries. Basic research for closed MHD is most actively pursued in Japan, which potentially can provide a very high efficiency and a simple and reliable system.

  • PDF

노인들에 대한 균형검사의 검사-재검사 신뢰도 (Test-retest Reliability of Balance Tests in Older Adults)

  • 강순희
    • 대한물리치료과학회지
    • /
    • 제16권4호
    • /
    • pp.49-57
    • /
    • 2009
  • Background: The purpose of this study was to assess the test-retest reliability of balance measurements in older adults using balance measurement system(Good Balance). Methods: The subjects consisted of 49 female and 20 male in community-dwelling older adults. This study used a repeated-measure design. Each subject completed all the different tests once and they were then repeated with 2 minutes in between. Repeated two-ways analysis of variance(ANOVA), representing two test times and both sexes, was calculated for each of the two dependent variables. Intraclass correlation coefficients(ICCs) were used to assess the test-retest reliability. Results: 1) There was not significant difference between test and retest for mediolateral sway speed and anterioposterior sway speed under conditions of normal standing with eyes open, normal standing with eyes closed and semitandem standing with eyes open. There was not significant difference between males and females for mediolateral sway speed and anterioposterior sway speed under conditions of normal standing with eyes open, normal standing with eyes closed and semitandem standing with eyes open. There were not the interaction effects between genders and test time under three conditions. 2) The reproducibility between test and retest was excellent for anterioposterior sway speed(ICC=.77) under condition of normal standing with eyes open, and for mediolateral sway speed(ICC=.76) and anterioposterior sway speed(ICC=.84) under condition of semitandem standing with eyes open. The reproducibility between test and retest was fair to good for mediolateral sway speed(ICC=.64) under condition of normal standing with eyes open, for mediolateral sway speed(ICC=.63) and anterioposterior sway speed(ICC=.75) under condition of normal standing with eyes closed. Conclusion: Balance tests in older adults using balance measurement system(Good Balance) demonstrated acceptable levels of reliability.

  • PDF

지하수정호 결합 복합지열시스템의 시범운영 효과분석 (Analysis of Test Operations Effect of Open-Closed Loops Complex Geothermal System Combined with Groundwater Well)

  • 송재용;김기준;이근춘;정교철
    • 지질공학
    • /
    • 제28권3호
    • /
    • pp.475-488
    • /
    • 2018
  • 본 연구에서는 지하수 관정을 활용하고 밀폐형-개방형이 결합된 복합지열시스템(CWG 시스템)을 시설재배지에 적용하여 열원측 및 부하측의 열교환량과 투입된 전력량 대비 효율을 평가하였다. 또한, 운전 과정에서의 외기온도 및 시설재배지 온도를 평가하여 복합지열시스템 적용시의 냉난방 효과를 분석하였다. 냉방운전시 열원측 열교환량 평가결과, 약 235 L/min의 지하수가 유입되는 개방형에서 평균 90.0 kW/h, 약 85 L/min의 순환수가 유동하는 밀폐형에서 40.1 kW/h의 열교환량이 발생하였으며, 전체 열교환량은평균 130.1 kW/h로 분석되었다. 부하측에서 실질적으로 전달되는 열교환량은 평균 110.4kW/h로 평가되었다. 복합지열시스템의 냉방효율을 분석한 결과, 평균 EER는 5.63으로 분석되었다. 난방운전 시 열원측 열교환량 평가결과, 약 266 L/min의 지하수가 유입되는 개방형에서 평균 60.4 kW/h, 약 86 L/min의 순환수가 유동하는 밀폐형에서 22.4 kW/h의 열교환량이 발생하였으며, 전체 열교환량은 평균 82.9 kW/h로 분석되었다. 부하측에서 실질적으로 전달되는 열교환량은 평균 112.0 kW/h로 평가되었다. 복합지열시스템의 난방효율을 분석한 결과, 평균 COP는 3.92로 분석되었다. 외기온도와 CWG 시스템을 적용한 시설하우스 및 비교 시설하우스 내부온도와의 상관관계를 분석한 결과 30RT 용량의 CWG 시스템 하우스가 비교 하우스에 비해 외기온도 $20^{\circ}C$인 경우 $3.4^{\circ}C$, 외기온도 $25^{\circ}C$인 경우 $6.8^{\circ}C$, 외기온도 $30^{\circ}C$인 경우 $10.1^{\circ}C$, 외기온도 $35^{\circ}C$인 경우 $13.4^{\circ}C$의 온도가 저감되는 것으로 평가되었다. 이러한 결과를 볼 때, 본 시스템을 적용할 경우 일반적으로 외기온도가 $30^{\circ}C$ 이상을 보이는 여름철에 CWG 시스템을 적용하지 않은 시설재배지에 비해 약 $10^{\circ}C$ 이상의 냉방효과가 나타낼 수 있을 것으로 판단된다. 이와 같은 결과는 시설재배지의 복합지열시스템 설계에 활용될 수 있고, 다양한 조건에서의 시험성과와 종합하여 복합지열시스템의 냉난방 효과에 대한 보다 명확한 규명이 가능할 것으로 판단된다.

Feedback Control for Expanding Range and Improving Linearity of Microaccelerometers

  • Park, Yong-Hwa;Shim, Joon-Sub;Park, Sang-Jun;Kwak, Dong-Hun;Ko, Hyoung-Ho;Song, Tae-Yong;Huh, Kun-Soo;Park, Jahang-Hyon;Cho, Dong-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1706-1710
    • /
    • 2004
  • This paper presents a feedback-controlled, MEMS-fabricated microaccelerometer (${\mu}$XL). The ${\mu}$XL has received much commercial attraction, but its performance is generally limited. To improve the open-loop performance, a feedback controller is designed and experimentally evaluated. The feedback controller is applied to the x/y-axis ${\mu}$XL fabricated by sacrificial bulk micromachining (SBM) process. Even though the resolution of the closed-loop system is slightly worse than open-loop system, the bandwidth, linearity, and bias stability are significantly improved. The noise equivalent resolution of open-loop system is 0.615 mg and that of closed-loop system is 0.864 mg. The bandwidths of open-loop and closed-loop system are over 100 Hz. The input range, non-linearity and bias stability are improved from ${\pm}$10 g to ${\pm}$18 g, from 11.1 %FSO to 0.86 %FSO, and from 0.221 mg to 0.128 mg by feedback control, respectively

  • PDF

열린사슬 운동과 닫힌사슬운동시 내측광근과 대퇴이두근의 근활성도 차이 (Activation of Vastus Medialis and Biceps Femoris Muscle in Open and Closed Kinetic Chain Exercise)

  • 석창엽;이창렬;이문환
    • 대한예방한의학회지
    • /
    • 제12권3호
    • /
    • pp.115-128
    • /
    • 2008
  • Purpose : This study was performed to distinguish the muscle activation of vastus medialis and biceps femoris through open and closed kinetic chain exercise. Methods : 31 healthy male and female students in Daegu Health College were participated in this study. All subjects were conducted three types open and closed kinetic chain exercises to examine muscle activity during the last four seconds using the sEMG system. Collected EMG data were normalized using the maximal voluntary isometric contraction(MVIC). Results : MVIC of each muscle was showed significantly increased(p<0.5). In the case of open chain exercise, the type 3 exercise most increased than type 2 and 3 exercise in vastus medialis than biceps femoris muscle. The closed chain exercise presented type 6 exercise most increased than type 4 and 5 exercise in biceps femoris than vastus medialis. Conclusion : This study finally proved that muscle activity which maintains stability of knee differ from depending on the types of exercises. Therefore, the combination of the two chain exercises is believed to greatly contribute to increments in muscle activity.

  • PDF

밀폐형과 개방형이 결합된 복합지열시스템의 지중열교환기 성능 분석 (Performance Analysis of Ground Heat Exchanger in Combined Well and Open-Closed Loops Geothermal (CWG) System)

  • 박영윤;송재용;이근춘;김기준;목종구;박유철
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권5호
    • /
    • pp.23-29
    • /
    • 2017
  • This study was conducted to evaluate performance of geothermal heat exchanger (GHE) in the combined well and open-closed loops geothermal (CWG) systems. The CWG systems were designed to combine open loop geothermal heat pumps and closed loop geothermal heat pumps for high energy efficiency. GHE of the CWG systems could be installed at pumping wells for agricultural usage. To get optimal heat exchange capacity of GHE of the CWG systems, 4 GHEs with various materials and apertures were tested at laboratory scale. Polyethylene (PE) and stainless steel (STS) were selected as GHE materials. The maximum heat exchange capacity of GHEs were estimated to be in the range of 33.0~104 kcal/min. The heat exchange capacity of STS GHEs was 2.4~3.2 times higher than that of PE GHE. The optimal cross section area of GHE and flow rate of circulating water of GHE were estimated to be $2,500mm^2$ and 113 L/min, respectively. For more complicated GHE of the CWG systems, it is necessary to evaluate GHEs at various scales.