• 제목/요약/키워드: Closed system and Open system

검색결과 514건 처리시간 0.035초

A Comparison of Dizziness Handicap Inventory Scores with Stability Index and Fourier Harmony Index in Healthy Individuals

  • Sang-Seok Yeo;Heun-Jae Ryu
    • The Journal of Korean Physical Therapy
    • /
    • 제35권4호
    • /
    • pp.105-110
    • /
    • 2023
  • Purpose: The purpose of this study was to determine whether the degree of dizziness affects static balance due to the disruption or absence of the senses involved in balance. To this end, the correlation between the Dizziness Handicap Inventory (DHI), which objectively evaluates dizziness, the Fourier Index (FI; Frequency bands of postural oscillation, F1, F2-4, F5-6, F7-8) and the Stability Index (ST), which evaluates static balance ability, were examined. Methods: This study investigated balance and dizziness issues in 30 healthy young adults. Participants underwent multiple tests like the DHI and tetra-ataxiometric posturography (Tetrax) under different conditions (eyes open/closed, standing on a foam-rubber pillow, and with the head in various orientations). Results: We found that F1 exhibited a weak positive correlation with dizziness under normal conditions, as well as when the eyes were closed (r=0.396, p<0.05) and the head was tilted back (r=0.375, p<0.05). Meanwhile, F5-6 showed a moderate positive correlation with dizziness in both head-back (HB: r=0.471, p<0.05) and head-forward postures (r=0.404, p<0.05). Lastly, both F7-8 and ST demonstrated a moderate positive correlation with dizziness when the head was in a forward posture (F7-8: r=0.483; ST: r=0.403, p<0.05). Conclusion: The study results indicate that the severity of dizziness affects sensory systems and balance. It also suggests that head movements, especially forward and backward, further stimulate the vestibular system, intensifying dizziness, and balance problems in affected individuals.

샌드위치패널 창고의 벽 천장 접합부 방호용 스프링클러설비 실험 (A Experiment of Sprinkler System to Protect Ceiling Joints of Sandwich Panel Warehouses)

  • 안병국;김운형;서동훈;함은구
    • 한국재난정보학회 논문집
    • /
    • 제15권1호
    • /
    • pp.98-108
    • /
    • 2019
  • 연구목적:본 연구는 화재 시 샌드위치패널 구조 창고의 벽 천장접합부 방호를 위한 스프링클러 성능확인 실험을 목적으로 한다. 연구방법: 현장조사결과를 기반으로 창고의 공간규격과 가연물을 선정하고 벽 코너 및 헤드 직하부에서의 방호실험을 수행하고 결과를 분석하였다. 연구결과:벽 코너 화재 시나리오에 대해서 K-80 폐쇄형 스프링클러헤드의 작동으로 샌드위치 패널의 착화 및 접합부 손상이 방지됨을 확인하였다. 결론:샌드위치패널 심재로의 착화 및 연소방지를 통한 화세제어로 이를 가정한 소방대의 소화 및 구조활동을 위한 표준진압대책이 마련되어야 한다.

부분적 체중부하를 통한 트레드밀 훈련이 만성요통환자의 균형능력과 기능장애, 통증에 미치는 영향 (Effect of Partial Weight Supported Treadmill Training on Balance, Dysfunction and Pain in Patients With Chronic Low Back Pain)

  • 김대현;김선엽
    • 한국전문물리치료학회지
    • /
    • 제23권1호
    • /
    • pp.1-10
    • /
    • 2016
  • Background: Patients with chronic low back pain (CLBP) functionally adapt to decreased postural control due to impaired processing of sensory information. Standing postural control has been the focus of recent research in CLBP. Change in postural control may be a risk factor for CLBP, although available studies are not conclusive. Objects: This study aimed to identify the role of partial weight supported treadmill training (PWSTT) in improving balance, dysfunction, and pain in patients with chronic low back pain. Methods: The study included 22 patients with CLBP. Patients in the control group ($n_1=8$) performed three 20 min stabilization exercise sessions per week, for 4 weeks. Patients in the full weight treadmill training group ($n_2=7$) performed treadmill training for 30 min after stabilization exercise. Patients in the PWSTT group ($n_3=7$) performed PWSTT with 20% of their body weight unloaded after stabilization exercises. By using the Biodex balance system, the dynamic balance abilities of the patients in the three groups were assessed in the quiet standing position under combined conditions of visual feedback (eyes open and closed) and platform stability (level 8). The Korean version of the Oswestry Disability Index and visual analogue scale score were used as the main measure. Results: The results of this study showed that dysfunction and pain were significantly improved in all groups. Although dynamic postural stability with eyes closed was significantly improved only in the PWSTT group (p<.05), no significant difference was found in the other groups. Conclusion: The results of this study indicate that PWSTT improved balance, dysfunction and pain in the patients with CLBP. Thus, this intervention is necessary for patients with CLBP with decreased postural control.

뇌파 기반 개인 인증 시스템 개발 (Development of a Biometric Authentication System Based on Electroencephalography)

  • 최가영;김은지;강예나;박수빈;박수진;최수인;황한정
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권1호
    • /
    • pp.43-47
    • /
    • 2018
  • Traditional electroencephalography (EEG)-based authentication systems generally use external stimuli that require user attention and relatively long time for authentication. The aim of this study is to investigate the feasibility of biometric authentication based on EEG without using any external stimuli. Seventeen subjects took part in the experiment and their EEGs were measured while repetitively closing and opening their eyes. For identifying each subject, we calculated inter- and intra-subject cross-correlation using changes in alpha activity (8-13 Hz) during eyes closed as compared to eyes open. In order to optimize the number of recording electrodes, we calculated authentication accuracy by progressively reducing the number of electrodes used in the analysis. Significant increase in alpha activity was observed for all subjects during eyes closed, focusing on occipital areas, and spatial patterns of changed alpha activity were considerably different between the subjects. A mean authentication accuracy of 92.45% was obtained, which was retained over 75% when using only 8 electrodes placed around occipital areas. Our results could demonstrate the feasibility of the proposed novel authentication method based on resting state EEGs.

자기 폐회로를 갖는 축형 마그네틱 기어 (Axial magnetic gear with a closed magnetic path)

  • 정광석
    • 한국산학기술학회논문지
    • /
    • 제18권7호
    • /
    • pp.726-733
    • /
    • 2017
  • 마그네틱 셔터 기어는 원주상에 마주하는 영구자석 레이어간의 자기장을 고조파 모듈레이터를 통해 동기화시켜 동력을 전달하는 장치이다. 이러한 장치는 기계식 감속기에 필적할만한 토크를 발생시키기 위해 과다한 희토류 영구자석이 이용되기 때문에 본 논문에서는 영구자석간의 자기 경로를 변화시켜 영구자석의 양을 기존 마그네틱 기어 대비 50% 수준으로 감소시킨 새로운 방식의 축형 마그네틱 기어를 제안한다. 제안한 시스템의 토크 크기는 공극 자기장의 고조파 분석과 유한 요소 해석을 통해 기존 시스템과 비교된다. 모듈레이터 두께와 개방비가 전달 토크의 크기에 영향을 미치는 주요 설계변수로 고려되어 민감도 해석이 수행되며 고속측과 저속측의 영구자석 극수에 의해 결정되는 기어비에 따른 코깅의 크기가 분석된다. 기계적인 접촉없이 커플링되어 동력을 전달하는 고속측과 저속측 사이의 동적 지배 모델이 유도된다. 2관성 공진계의 동특성을 갖는 유도된 모델을 기초로 하여 선형 제어기를 설계하여 고속측의 계단 입력 위치 제어를 수행하였다.

The Influence of Pronated Foot Posture on Knee Isokinetic Strength, Static and Dynamic Postural Stability in Healthy Young Individuals

  • Chun, Woochan;Kim, Hee-su;Park, Sieun;Park, Jihea;Shim, Seunghee;Park, Sookyoung
    • 한국전문물리치료학회지
    • /
    • 제28권3호
    • /
    • pp.168-176
    • /
    • 2021
  • Background: The foot is a complex body structure that plays an important role in static and dynamic situations. Previous studies have reported that altered foot posture might affect knee joint strength and postural stability, however their relationship still remains unclear. Objects: The purpose of this study was to identify whether pronated foot posture has an influence on knee isokinetic strength and static and dynamic postural stability. Methods: Forty healthy young males aged 18 to 26 years were included. Foot posture was evaluated using the Foot Posture Index-6 (FPI-6), and the subjects were divided into two groups according to their FPI-6 scores: a neutral foot group (n = 20, FPI-6 score 0 to +5) and a pronated foot group (n = 20, FPI-6 score +6 or more). Biodex Systems 3 isokinetic dynamometer was used to evaluate knee isokinetic strength and hamstring to quadriceps ratio at three angular velocities: 60°/sec, 90°/sec, and 180°/sec. The static and dynamic postural stability in a single-leg stance under the eyes-open and eyes-closed conditions were measured with a Biodex Balance System. Results: There were no significant differences between the groups in knee isokinetic strength and static postural stability (p > 0.05), but there was a significant difference in the medial-lateral stability index (MLSI) for dynamic postural stability under the eyes-closed condition (p = 0.022). The FPI-6 scores correlated significantly only with the dynamic overall stability index (OSI) and the MLSI (OSI: R = 0.344, p = 0.030; MLSI: R = 0.409, p = 0.009) under the eyesclosed condition. Conclusion: Participants with pronated foot had poorer medial-lateral dynamic stability under an eyes-closed condition than those without, and FPI-6 scores were moderately positively correlated with dynamic OSI and dynamic MLSI under the eyes-closed condition. These results suggest that pronated foot posture could induce a change in postural stability, but not in knee isokinetic strength.

Target alignment method of inertial confinement fusion facility based on position estimation

  • Lin, Weiheng;Zhu, Jianqiang;Liu, Zhigang;Pang, Xiangyang;Zhou, Yang;Cui, Wenhui;Dong, Ziming
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3703-3716
    • /
    • 2022
  • Target alignment technology is one of the most critical technologies in laser fusion experiments and is an important technology related to the success of laser fusion experiments. In this study, by combining the open-loop and closed-loop errors of the target alignment, the Kalman state observer is used to estimate the position of the target, which improves the observation precision of the target alignment. Then the optimized result is used to guide the alignment of the target. This method can greatly optimize the target alignment error and reduce uncertainty. With the improvement of the target alignment precision, it will greatly improve the reliability and repeatability of the experiments' results, thereby improving the success rate of the experiments.

유도된 다리길이 차이가 안정성한계와 정적 자세균형에 미치는 영향 (Effect of Induced Leg Length Discrepancy on the Limitation of Stability and Static Postural Balance)

  • 한진태
    • PNF and Movement
    • /
    • 제16권2호
    • /
    • pp.267-273
    • /
    • 2018
  • Purpose: Leg length discrepancy (LLD) is one of the risk factors for postural imbalance. This study aimed to investigate the effect of induced leg length discrepancy on the limitation of stability (LOS) and static postural balance. Methods: Thirteen adults (males, 7; females 6) participated in this study. The LOS and static postural balance [sway length, sway area, and sway velocity of center of gravity (COG) displacement] were measured by the balance trainer system. The subjects were asked to move the COG for the anterior, posterior, and left and right directions maximally and to keep standing on the platform with and without induced LLD for 30 s in the open and closed eyes conditions, respectively. The LLD was artificially induced to 2 cm using insole. Wilcoxon test was used to compare the LOS and the static postural balance between with and without induced LLD. Results: The anterior and posterior LOS significantly decreased in induced LLD (p<0.05), and the left and right LOS were not significantly different between with and without LLD (p>0.05). Sway length, sway area, and sway velocity of the COG displacement significantly decreased in induced LLD (p<0.05). Conclusion: This study suggests that induced LLD could decease the antero-posterior LOS and increased the static postural balance. Therefore, the LLD could disturb the postural balance.

중국의 수산물 생산과 어정관리에 관한 연구 (A Study on aquatic products and fishery administration in china)

  • 고재모
    • 수산경영론집
    • /
    • 제30권1호
    • /
    • pp.77-96
    • /
    • 1999
  • Since the onset of its economic reform and the open door policy in the late 1970s, China's overall economic growth rate has been continuing about 10% per year. The marine sector is not allowed exception, aquatic products increased sharply from 4.66 million MT in 1978 to 36.02 million MT in 1997, and then China is remained the largest producing country in the world aquatic market and her role would be expanded. Korea having a common boundaries to China is subjected unescapably both in domestic and export markets by the influence of the remarkable growth of China's aquatic products. If China were admitted entrance of WTO(World Trade Organization)in the near future, her influence is getting more serious. Well, we are necessary to understand the characteristics of China's aquatic products and to review fishery policies implemented by the China government. This paper is organized into two major parts, the one includes the structural changes of aquatic products, fishing and cultivating in the coast, latent and estimated production in China, and the other includes the main contents of fishery policies and measures of government administration. A characteristic of China's aquatic products is that cultivated production, especially, shellfish outputs continues to rapid increase. The major means of administration are an execution of fishing license system and setting up no-fishing zone and closed season for fishery. China is no longer a marginal player in international economic and world aquatic market. So, we will not only understand China's aquatic conditions and problems, but will also see the usefulness in continuing the cooperative relationship for a long time to come.

  • PDF

생체신호에 기반한 웨어러블 로봇 내 부분 압박 바지 착용 시 효과 검증 (Verification of Effectiveness of Wearing Compression Pants in Wearable Robot Based on Bio-signals)

  • 박소영;이예진
    • 한국의류학회지
    • /
    • 제45권2호
    • /
    • pp.305-316
    • /
    • 2021
  • In this study, the effect of wearing functional compression pants is verified using a lower-limb wearable robot through a bio-signal analysis and subjective fit evaluation. First, the compression area to be applied to the functional compression pants is derived using the quad method for nine men in their 20s. Subsequently, functional compression pants are prepared, and changes in Electroencephalogram (EEG) and Electrocardiogram (ECG) signals when wearing the functional compression and normal regular pants inside a wearable robot are measured. The EEG and ECG signals are measured with eyes closed and open. Results indicate that the Relative alpha (RA) and Relative gamma wave (RG) of the EEG signal differ significantly, resulting in increased stability and reduced anxiety and stress when wearing the functional compression pants. Furthermore, the ECG analysis results indicate statistically significant differences in the Low frequency (LF)/High frequency (HF) index, which reflect the overall balance of the autonomic nervous system and can be interpreted as feeling comfortable and balanced when wearing the functional compression pants. Moreover, subjective sense is discovered to be effective in assessing wear fit, ease of movement, skin friction, and wear comfort when wearing the functional compression pants.