• 제목/요약/키워드: Closed system and Open system

검색결과 514건 처리시간 0.034초

복수정을 이용한 개방형 지열 시스템의 초기투자비 회수기간 분석 (Analysis of the Initial Cost Payback Period on the Open-loop Geothermal System Using Two Wells)

  • 조정흠;남유진
    • 설비공학논문집
    • /
    • 제29권3호
    • /
    • pp.119-126
    • /
    • 2017
  • Recently, ground source heat pump systems are being used in buildings for cooling and heating to reduce greenhouse gas and save energy. However, ground source heat pump systems mainly use the vertical closed-loop geothermal system design rather than the open-loop geothermal system design. This is due to a lack of knowledge and few research feasibility studies. In this research, a dynamic thermal analysis numerical simulation based on a standard house model was conducted for an open-loop geothermal system. Based on heating load analysis results, the life cycle costs of a standard house using an open two-well geothermal system were analyzed and compared with a vertical closed-loop geothermal system, and a diesel boiler. As a result, it was found that using an open two-well geothermal system shows economic return on investment after three years.

폐쇄된 계의 닫힌 회전 운동에 대한 컴퓨터 씨뮬레이션 모델에 관한 연구 (A study on the computer simulation model of the closed rotating system about the closed system)

  • 정병태
    • 한국컴퓨터산업학회논문지
    • /
    • 제8권3호
    • /
    • pp.181-186
    • /
    • 2007
  • 폐쇄된 계 내부와 외부에서 작용되는 운동에는 선형 열린 운동과 닫힌 운동이 있고 비선형 열린 운동과 닫힌 운동이 있다. 선형 닫힌 운동이 마찰과 같은 외력을 받을시 갇힌 운동이 발생된다. 회전 닫힌 운동에도 마찰과 같은 외력을 받을시 회전 갇힌 운동이 있음을 해석 한다. 회전 닫힌 운동과 갇힌 운동을 액체 실험 장치를 통하여 정량적으로 고찰하고 회전 갇힌 운동이 있음을 분석하여 회전 열린 운동, 닫힌 운동 과 갇힌 운동에 대한 컴퓨터 씨뮬레이션 수식모델을 정한다. 그리고 간단한 운동 장치의 그래픽 구조를 고려 할 수 있도록 소개한다.

  • PDF

개방형 흡인술과 폐쇄형 흡인술이 인공호흡기 사용 중환자의 산소포화도와 활력징후에 미치는 효과 (A Comparison of the Opened Versus Closed-System of Suctioning -In Oxygen Saturation, Vital Signs and Suction Time-)

  • 서민숙;박경숙
    • 성인간호학회지
    • /
    • 제21권2호
    • /
    • pp.141-154
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the difference of change in oxygen saturation, vital signs and suction time taken for the suctioning during endotracheal suctioning performed with closed suction system and with opened suction system. Methods: Data were collected from 31 adult patients with ventilator treatment who were admitted to a university hospital in Seoul and the collection period was from July 1 to November 15, 2005. Oxygen saturation, heart rate, respiration rate and mean arterial pressure were collected immediately prior to the suctioning intervention, during and 1 and 5 minutes after the suctioning from opened suction system and closed suction system. Results: 1) The difference in oxygen saturation was statistically significant in recovery time for oxygen saturation to return to baseline values after suctioning was significantly rapid on closed suction system (p<.05). 2) The difference in heart rate, respiration rate and mean arterial pressure was statistically insignificant 3) The suction time was shorter in closed suction system. Conclusion: Closed suction system is more efficient, as compared with the open suction system in the ventilator treatment.

  • PDF

A Strategy for Balanced Power Regulation of Energy Storage Systems in a Distribution System during Closed-Loop Operation

  • Han, Yoon-Tak;Oh, Joon-Seok;Cha, Jae-Hun;An, Jae-Yun;Hyun, Seung-Yoon;Lee, Jong-Kwan;Seo, In-Yong;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2208-2218
    • /
    • 2017
  • To resolve overload in a distribution system, a distribution system operator (DSO) often performs a load transfer using normally open tie points and switches in the distribution line. During this process, the distribution system is momentarily operated in closed-loop operation. A closed-loop current in the distribution system can cause a power failure due to excess breaking current in the circuit breakers and reclosers. Therefore, it is necessary to calculate the closed-loop current exactly. However, if there are a large number of distributed generation (DG) systems in the distribution system, such as energy storage systems (ESS), they might obstruct the closed-loop operation based on bidirectional power flow. For quick and precise operation of a closed-loop system, the ESS has to regulate the power generation while satisfying closed-loop operation in the worst cases. We propose a strategy for balanced power regulation of an ESS. Simulations were carried out using PSCAD/EMTDC, and the results were compared with calculation results.

Dynamics of the Macpherson Strut Motor-Vehicle Suspension System in Point and Joint Coordinates

  • Attia, Hazem-Ali
    • Journal of Mechanical Science and Technology
    • /
    • 제17권9호
    • /
    • pp.1287-1296
    • /
    • 2003
  • In this paper the dynamic analysis of the Macpherson strut motor-vehicle suspension system is presented. The equations of motion are formulated using a two-step transformation. Initially, the equations of motion are derived for a dynamically equivalent constrained system of particles that replaces the rigid bodies by applying Newton's second law The equations of motion are then transformed to a reduced set in terms of the relative joint variables. Use of both Cartesian and joint variables produces an efficient set of equations without loss of generality For open chains, this process automatically eliminates all of the non-working constraint forces and leads to an efficient solution and integration of the equations of motion. For closed loops, suitable joints should be cut and few cut-joints constraint equations should be included for each closed chain. The chosen suspension includes open and closed loops with quarter-car model. The results of the simulation indicate the simplicity and generality of the dynamic formulation.

Detecting Bladder Biomarkers for Closed-Loop Neuromodulation: A Technological Review

  • Park, Eunkyoung;Lee, Jae-Woong;Kang, Minhee;Cho, Kyeongwon;Cho, Baek Hwan;Lee, Kyu-Sung
    • International Neurourology Journal
    • /
    • 제22권4호
    • /
    • pp.228-236
    • /
    • 2018
  • Neuromodulation was introduced for patients with poor outcomes from the existing traditional treatment approaches. It is well-established as an alternative, novel treatment option for voiding dysfunction. The current system of neuromodulation uses an open-loop system that only delivers continuous stimulation without considering the patient's state changes. Though the conventional open-loop system has shown positive clinical results, it can cause problems such as decreased efficacy over time due to neural habituation, higher risk of tissue damage, and lower battery life. Therefore, there is a need for a closed-loop system to overcome the disadvantages of existing systems. The closed-loop neuromodulation includes a system to monitor and stimulate micturition reflex pathways from the lower urinary tract, as well as the central nervous system. In this paper, we reviewed the current technological status to measure biomarker for closed-loop neuromodulation systems for voiding dysfunction.

Simple and Flexible Temperature Control System for Space Environment Test

  • Lee, Sang-Hoon;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won;Choi, Seok-Weon
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.29.1-29.1
    • /
    • 2008
  • The temperature control system which is using liquid and gaseous nitrogen has been known as the most economical system to simulate space temperature condition due to relatively not expansive price of the liquid nitrogen (less than 0.2 USD per liter). And, among these systems, the closed loop system which circulates compressed nitrogen gas come from sprayed liquid nitrogen by blower and makes a target temperature with heat from an electrical heater and flow rate of liquid nitrogen is prevail all over the world. But, this complete closed loop system requires expansive equipments such as blower, heater, and liquid nitrogen injector, and special maintenance on the system. Therefore, KARI is developing efficient and simple open loop system which utilizes liquid and gaseous nitrogen with eliminating a special blower and other expansive units. In this study, this open loop system with more efficiency and flexibility will be designed and introduced.

  • PDF

AC 서보 전동기 시스템의 상태공간 모델 식별에 관한 연구 (A Study on State-Space Model Identification of AC Servo Motor System)

  • 이태훈;김상환;송봉철;원충연;이상석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.199-204
    • /
    • 2000
  • Generally, The systems are so complex that it not possible to obtain reasonable model using physical insight. Also a model based on physical insight contains a number of unknown parameters even if the structure is derived from physical laws. To solve these problems, the systems identification is described in this paper. So, AC servo motor system which has both open loop and closed loop is selected as an example for identification. A state-space model of AC servo motor system is identified through open loop experiment and identified through closed loop experiment and using pole placement integral controller to open loop system. As the results, From ARMA model, We have obtained continuous-time state space model.

  • PDF

Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석 (Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff)

  • 이준호;방기웅;홍성철
    • 대한환경공학회지
    • /
    • 제31권11호
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone은 높은 수면적부하율 운전이 가능하고, 구동부분이 없고, 운전 및 유지관리비가 적게 소요되어 미세입자물질제거에 효과적인 장치로 다양한 산업 분야에서 활용되고 있다. Hydrocyclone에 나선형 유입부를 통해 직각으로 유입되어 중력이 아닌 원심력에 의해 입자물질이 하부배출구로 분리되고 처리수는 vortex finder를 통해 배출된다. 입자분리에 hydrocyclone은 많은 장점을 가지고 있음에도 불구하고 도시지역 강우유출수 처리사례는 드문 실정이다. 본 연구에서는 변형된 hydrocyclone과 perlite 여재를 조합한 hydrocyclone filter (HCF)을 이용하여 강우유출수내 미세입자의 제거능을 분석하였다. 입자물질들은 인공입자들을 이용하여 강우유출수내 입자농도를 모의 실험하였다. 인공입자들을 물에 분산시켜 강우유출수를 재현하였는데 사용한 입자들은 이온교환 수지, 도로측구 퇴적물질, 상업지역 맨홀퇴적물질, 그리고 실리카겔 등이다. 하부배출부와 vortex finder 구조를 달리하여 HCFopen system과 HCF-closed system으로 구분하여 처리능을 분석하였다. HCF장치는 아크릴 수지를 이용하였는데 hydrocyclone의 직경은 120 mm이고 여과조의 직경은 250 mm이고 전체적인 높이는 800 mm로 제작하였다. 운전조건별 유입수 농도와 입경을 다양하게 적용하였고 SS와 COD농도를 분석하여 처리효율을 산정하였다. HCF-open system의 경우 운전 가능한 최대 수면적부하율은 700 $m^3/m^2$/day이었고 HCF-closed system의 경우 수면적부하율 1,200 $m^3/m^2$/day까지이다. HCF-open system 운전결과 HCFclosed system에 비교하여 평균 수면적부하율은 2배 이상 높게 운전이 가능하며 처리효율도 8~20% 이상 향상되는 것으로 분석되었다. 또한 유입수 SS농도가 높을수록 처리효율이 증가하며, 입경이 클수록 수면적부하율의 변화에 대한 처리효율의 영향이 적은 것으로 분석되었다. HCF-closed system의 실험을 통한 수면적부하율 변화에 대한 실리카겔입자의 제거 효율과 CFD입자추적기법을 이용한 예측 처리효율을 비교한 결과 CFD에 예측효율이 실제실험결과와 비교하여 다소 높게 나타나지만 처리효율의 경향은 매우 유사하게 나타나 CFD추적기법을 이용한 HDS유형 처리장치 설계 시 유용한 도구로 활용될 수 있을 것으로 판단된다.

Geometrical Construction of the S Matrix and Multichannel Quantum Defect Theory for the two Open and One Closed Channel System

  • Lee, Chun-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권7호
    • /
    • pp.971-984
    • /
    • 2002
  • The multichannel quantum defect theory (MQDT) is reformulated into the form of the configuration mixing (CM) method using the geometrical construction of the S matrix developed for the system involving two open and one closed channels. The reformulation is done by the phase renormalization method of Giusti-Suzor and Fano. The rather unconventional short-range reactance matrix K whose diagonal elements are not zero is obtained though the Lu-Fano plot becomes symmetrical. The reformulation of MQDT yields the partial cross section formulas analogous to Fano's resonance formula, which has not easily been available in other's work.