• Title/Summary/Keyword: Closed loop control

Search Result 1,414, Processing Time 0.027 seconds

Bridges dynamic analysis under earthquakes using a smart algorithm

  • Chen, Z.Y.;Meng, Yahui;Wang, Ruei-yuan;Chen, Timothy
    • Earthquakes and Structures
    • /
    • v.23 no.4
    • /
    • pp.329-338
    • /
    • 2022
  • This work addresses the optimization controller design problem combining the AI evolution bat (EB) optimization algorithm with a fuzzy controller in the practical application of a reinforced concrete frame structure. This article explores the use of an intelligent EB strategy to reduce the dynamic response of Lead Rubber Bearing (LRB) composite reinforced concrete frame structures. Recently developed control units for plant structures, such as hybrid systems and semi-active systems, have inherently non-linear properties. Therefore, it is necessary to develop non-linear control methods. Based on the relaxation method, the nonlinear structural system can be stabilized by properly adjusting the parameters. Therefore, the behavior of a closed-loop system can be accurately predicted by determining the behavior of a closed-loop system. The performance and durability of the proposed control method are demonstrated by numerical simulations. The simulation results show that the proposed method is a viable and feasible control strategy for seismically tuned composite reinforced concrete frame structures.

Development of KOMPSAT-2 Vehicle Dynamic Simulator for Attitude Control Subsystem Functional Verification

  • Suk, Byong-Suk;Lyou, Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1465-1469
    • /
    • 2003
  • In general satellite verification process, the AOCS (Attitude & Orbit Control Subsystem) should be verified through several kinds of verification test which can be divided into two major category like FBT (Fixed Bed Test) and polarity test. And each test performed in different levels such as ETB (Electrical Test Bed) and satellite level. The test method of FBT is to simulate satellite dynamics with sensors and actuators supported by necessary environmental models in ETB level. The VDS (Vehicle Dynamic Simulator) try to make the real situation as possible as the on-board processor will undergo after launch. The purpose of FBT test is to verify that attitude control logic function and hardware interface is designed as expected with closed loop simulation. The VDS is one of major equipments for performing FBT and consists of software and hardware parts. The VDS operates in VME environments with target board, several commercial boards and custom boards based on the VxWorks real time operating system. In order to make time synchronization between VDS and satellite on-board processor, high reliable semaphore was implemented to make synchronization with the interrupt signal from on-board processor. In this paper, the real-time operating environment used on VDS equipment is introduced, and the hardware and software configurations of VDS summarized in the systematic point of view. Also, we try to figure out the operational concept of VDS and AOCS verification test method with close-loop simulation.

  • PDF

Closed-loop active vibration control of a typical nose landing gear with torsional MR fluid based damper

  • Sateesh, B.;Maiti, Dipak K.
    • Structural Engineering and Mechanics
    • /
    • v.31 no.1
    • /
    • pp.39-56
    • /
    • 2009
  • Vibration is an undesirable phenomenon in a dynamic system like lightly damped aerospace structures and active vibration control has gradually been employed to suppress vibration. The objective of the current investigation is to introduce an active torsional magneto-rheological (MR) fluid based damper for vibration control of a typical nose landing gear. They offer the adaptability of active control devices without requiring the associated large power sources. A torsional damper is designed and developed based on Bingham plastic shear flow model. The numerical analysis is carried out to estimate the damping coefficient and damping force. The designed damper is fabricated and an experimental setup is also established to characterize the damper and these results are compared with the analytical results. A typical FE model of Nose landing gear is developed to study the effectiveness of the damper. Open loop response analysis has been carried out and response levels are monitored at the piston tip of a nose landing gear for various loading conditions without damper and with MR-damper as semi-active device. The closed-loop full state feedback control scheme by the pole-placement technique is also applied to control the landing gear instability of an aircraft.

Reconfiguring Second-order Dynamic Systems via P-D Feedback Eigenstructure Assignment: A Parametric Method

  • Wang Guo-Sheng;Liang Bing;Duan Guang-Ren
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.1
    • /
    • pp.109-116
    • /
    • 2005
  • The design of reconfiguring a class of second-order dynamic systems via proportional plus derivative (P-D) feedback is considered. The aim is to resynthesize a P-D feedback controller such that the eigenvalues of the reconfigured closed-loop system can completely recover those of the original close-loop system, and make the corresponding eigenvectors of the former as close to those of the latter as possible. Based on a parametric result of P-D feedback eigenstructure assignment in second-order dynamic systems, parametric expressions for all the P-D feedback gains and all the closed-loop eigenvector matrices are established and a parametric algorithm for this reconfiguration design is proposed. The parametric algorithm offers all the degrees of design freedom, which can be further utilized to satisfy some additional performances in control system designs. This algorithm involves manipulations only on the original second-order system matrices, thus it is simple and convenient to use. An illustrative example and the simulation results show the simplicity and effect of the proposed parametric method.

Structural Design of Sliding Mode Controllers Using Robust Inernal-Loop Compensator (강인 내부루프 보상기를 이용한 슬라이딩 모드 제어기의 구조적 설계)

  • Kim, Bong-Keun;Chung, Wan-Kyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.4
    • /
    • pp.351-361
    • /
    • 2001
  • In this paper, a generalized framework called as robust internal-loop compensator(RIC) is presented, and by using this, a structural design method of sliding of sliding mode controller is proposed. First, a general sliding mode controller is derived and a stabilizing control input is designed based on Lyapunov redesign for the system in the presence of uncertainty and disturbance. And adopting the internal model following control, RIC is proposed. Next, using the structural characteristics of the proposed RIC, disturbance attenuation characteristics are analyzed and the performance of the closed-loop system is predicted. Through this analysis, it is shown that if the control gain of RIC is increased by N times, the magnitude of error is reduced to its 1/N. the proposed method is verified through experiments using a high-precision positioning system and the performance is evaluated.

  • PDF

Translational control of a one link flexible arm

  • Lee, Seong-Cheol;Seiji Chonan;Hikaru Inooka
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1989.10a
    • /
    • pp.577-582
    • /
    • 1989
  • This is a study of the translational end-point control of a single link flexible arm-with a tip mass. The beam is mounted on a translational mechanism driven by the ball screw, whose rotation is controlled by DC servomotor. The problem of shifting the end-point from its initial position to the commanded position is studied analytically both for the open-loop control subjected to some path functions and for the closed-loop control using the feedback of the tip information.

  • PDF

A STUDY ON THE RELATION BETWEEN CLOSED-FORM DESCRIPTION AND RECURSIVE-FORM REALIZATION OF ASAPTIVE CONTROL OF MANIPULATORS

  • Kubozono, Takeshi;Yamakita, Masaki;Furuta, Katsuhisa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1785-1789
    • /
    • 1991
  • Recently, a number of papers on adaptive control scheme of manipulators are proposed. Slotine and Li[1] showed an adaptive control scheme for robot manipulator. The controller was described in closed form. And later Niemeyer and Slotine discussed about a computational implementation of the controller in recursive form[2]. Walker proposed another adaptive control scheme which can be implemented by a recursive-form controller[4]. Closed-form description is used for the analysis or design of adaptive control systems while recursive-form realization is used for implementation of the controller. The relation between the closed-form realization and the recursive-form one seems to be inadequately referred. Hence, it makes sense to consider the relation between the closed-form description and the recursive-form one. In this paper, first, we make a simple derivation of an closed-form dynamics description of a robot arm from its recursive-form description. And then we derive the closed-form realization of Walker's scheme applied to manipulators having no kinematic loop. We clarify the difference between the Walker's scheme and Slotine's and evaluate the convergence under the controllers.

  • PDF

Dynamic Analysis and Control Loop Design of ZVS-FB PWM DC/DC Converter (ZVS-FB PWM DC/DC 변환기의 동특성 해석 및 제어기 설계)

  • 이득기;윤길문;차영길;김흥근
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.231-239
    • /
    • 1998
  • This paper presents the dynamic analysis and control loop design of a zero voltage switching full bridge (ZVS-FB) PWM DC/DC converter. The small-signal model is derived incorporating the effects of phase shift control and the utilization of transformer leakage inductance and power FET junction capacitance to achieve zero voltage resonant switching. These effects are modeled by introducing additional feedforward and feedback terms for duty cycle modulation. Based on the results of the small-signal analysis, the control loop is designed using a simple two-pole one-zero compensation circuit. To show the validity of the design procedures, the small signal analysis of the closed loop system is carried out and the potential of the zero voltage switching and the superiority of the dynamic characteristics are verified through the experiment with a 2 kW prototype converter.

  • PDF

Study on Automatic Mixing of Nutrient Solution Using ion Electrodes for Closed-Loop Hydroponics (이온전극을 이용한 순환식 양액 자동 조제에 관한 연구)

  • 김민규;류관희;장유섭;김기영
    • Journal of Biosystems Engineering
    • /
    • v.27 no.5
    • /
    • pp.425-432
    • /
    • 2002
  • This study was carried out to develop an automatic mixing system of nutrient solution for closed-loop hydroponics using ion electrodes. The results of the study are summarized as follows: 1. It appeared that ion-electrodes had not to be soaked into nutrient solution for a long time since it was much less durable than EC or PH sensors. Once ion-electrodes were soaked into real nutrient solution for a long time, they became unstable. 2. ion measurement modules, which were able to sample recirculated nutrient solution and easily wash and dry ion-electrodes, were developed in order to use ion-electrodes continuously. 3. The results of calibration tests on three kinds of ion electrodes presented that the time required to read measurement data was over 30 seconds. Using the calibration data the regression equations for the ion electrodes were developed. 4. An automatic nutrient-solution mixing system using the three kinds of ion electrodes was developed and then its accuracy was examined. The control errors of the mixing system using ion electrodes were in the range of 9.8 to 12%.

Modeling and Design of Zero-Voltage-Switching Controller for Wireless Power Transfer Systems Based on Closed-Loop Dominant Pole

  • Chen, Cheng;Zhou, Hong;Deng, Qijun;Hu, Wenshan;Yu, Yanjuan;Lu, Xiaoqing;Lai, Jingang
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1235-1247
    • /
    • 2019
  • Zero-Voltage-Switching (ZVS) operation for a Wireless Power Transfer (WPT) system can be achieved by designing a ZVS controller. However, the performance of the controller in some industrial applications needs to be designed tightly. This paper introduces a ZVS controller design method for WPT systems. The parameters of the controller are designed according to the desired performance based on the closed loop dominant pole placement method. To describe the dynamic characteristics of the system ZVS angle, a nonlinear dynamic model is deduced and linearized using the small signal linearization method. By analyzing the zero-pole distribution, a low-order equivalent model that facilitates the controller design is obtained. The parameters of the controller are designed by calculating the time constant of the closed-loop dominant poles. A prototype of a WPT system with the designed controller and a five-stage multistage series variable capacitor (MSVC) is built and tested to verify the performance of the controller. The recorded response curves and waveforms show that the designed controller can maintain the ZVS angle at the reference angle with satisfactory control performance.