• Title/Summary/Keyword: Clinical torque

Search Result 84, Processing Time 0.046 seconds

A Study on the Clinical Factors Related to Vibration of Temporomandibular Joint (악관절진동의 임상적 관련요인에 관한 연구)

  • Kim, Jong-Young;Nam, Gheon-Woo;Han, Kyung-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.1
    • /
    • pp.37-47
    • /
    • 1999
  • This study was performed to investigate the factors related to vibration of temporomandibular joint during mandibular opening movement. For this study, 144 patients with temporomandibular disorders were randomly selected. Angle's classification, lateral guidance pattern, range of maximal mouth opening, preferred chewing side, and affected side were investigated clinically. Mandibular torque rotational movement during opening was recorded with $BioEGN^{(R)}$ and vibration of temporomandibular joint during opening was recorded with $Sonopak^{(R)}$. After clinical diagnosis was made, visual analogue scale(VAS) was used for evaluation of clinical progress of the subject's chief complaints. The author calculated VAS treatment index(VAS Ti) from the record of VAS. The more VAS Ti was, the less remission of subjective symptom was, The data were analyzed with SAS/Stat program and the results of this study were as follows: 1. There were no significant difference in all the variables of joint vibration by age and sex. 2. Integral and peak amplitude in patients of Angle's class I were higher than those of class II or III patients. Integral in patients of group function was higher than that in patients of canine guidance or other types of lateral excursion. 3. As to Angle's classification or lateral guidance type, there were almost not significant difference between subgroup of same class or type and subgroup of different class or type on both sides. And there were also almost not difference between one side and the other side related to preferred chewing side or affected side. 4. Patients with disk displacement with reduction showed higher value of integral and peak amplitude than any other patients. 5. Joint vibration variables significantly correlated with VAS Ti of pain. with clinical range of mouth opening, and with ingredients of mandibular torque rotational movement.

  • PDF

INFLUENCE OF IMPLANT DIAMETER ON THE OSSEOINTEGRATION OF IMPLANTS : AN EXPERIMENTAL STUDY IN RABBITS (임플란트 직경이 골유착에 미치는 영향에 관한 연구)

  • Lee Jun-Ho;Shin Sang-Wan;Kwon Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.169-181
    • /
    • 2003
  • Statement of problem : The survival rate of wide diameter implants was lower than of 3.75-mm implants in some clinical researches. Purpose : The purpose of this study was to investigate the influence of implant diameter on the osseointegration of implants in the rabbit femoral condyle and tibial metaphyses by means of removal torque measurements and histomorphometric analysis. Material and Method : Ten adult New Zealand White rabbits were used in this study Two 3.75-mm diameter implants were inserted through one cortical layer in the tibial metaphyses and one 3.75-mm diameter implant was inserted in the femoral condyle. 5.0-mm diameter implants were inserted in the other leg in the same manner. A total of 60 implants (3.75-mm diameter implants:30 : 5.0-mm diameter implants:30) were installed. After a healing time of 4 and 12 weeks, the peak removal torque values required to shear off the implants were recorded. From the removal torque values (Ncm) obtained, the mean shear stress ($N/mm^2$) was calculated. And the percentage of direct bone-to-implant contact and the percentage of bone area inside the thread were measured by Kappa Image Base-metreo. The Student's t-test was undertaken for statistical analysis (p<0.05). Results : The removal torque value of 5.0-mm diameter implants was higher than of 3.75-mm diameter implants (p<0.05). The difference of shear stress value between 3.75-mm and 5.0-mm diameter implants was not statistically significant (p>0.05). The percentage direct bone-to-implant contact had no statistical difference between two groups (p>0.05). The percentage of bone area inside the thread had no statistical difference between two groups (p>0.05). Conclusion It is concluded that the quality f osseointegration is not influenced by increasing implant diameter.

Acute Achilles Tendon Rupture : - Isokinetic plantarflexion torque evaluation after Krackow suture technique - (급성 아킬레스건 파열 - Krackow 봉합술 후 등속성 족저 굴곡력의 분석 -)

  • Jung, Hong-Geun;Yoo, Suk-Ju;Lee, Sung-Chul;Park, Hee-Gon;Kim, Ki-Young;Kim, Myung-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.2
    • /
    • pp.181-189
    • /
    • 2002
  • Purpose: We try to evaluate the functional outcomes of the ankle with isokinetic plantaflexion torque for acute achilles tendon rupture cases those treated by primary repair with the Krackow suture technique and early rehabilization. Materials and Method: The authors studied retrospectively, 15 patients of acute achilles tendon rupture treated and followed over six months, from July 1997 to May 2001. There were 12 men and 3 women, and mean age was 39.6year. The repair method of ruptured tendon was single or double Krackow suture technique. One week(5days-2weeks) after operation, early ROM with ankle-foot orthosis was started. We used Arner-Lindholm Scale for the clinical evaluation and analyzed patient's satisfaction and subjective strength deficit. We analyzed the dorsiflexion peak torque and plantarflexion peak torque of the ankle statistically with strength test with Cybex dynamometer. Result: In clinical results, we had 11 excellent cases(73%) and 3 good cases(20%). In patients satisfaction degree, 11 excellent cases(66.6%), 3 good cases(20%) and 2 fair cases(13.4%). And in strength deficit, 3 none deficit (20%), 9 minimal deficit(60%). We evaluated the isokinetic plantar flexion torque in 3months or 6months after operation. After 3 months, isokinetic test showed the mean functional deficits, 32% and 25% at $30^{\circ}$ and $120^{\circ}/sec$, in 7 cases(46.6%) of 15 cases respectively. After 6 months, the mean deficits were in 21%, 24% at 30. and $120^{\circ}/sec$, respectively. At 3 and 6 months' follow up, absolute value of isokinetic test showed increase of 25. 31bs to 421bs and 19.61bs to 271bs at $30^{\circ}$ and $120^{\circ}/sec$, respectively. Conclusion: We had good result for acute achilles tendon rupture treated by Krakow suture technique and early range of motion exercise of the ankle. After 6 months, strength deficit was 21% in all of cases but were able to return pre-injured state. This study shows Krakow suture technique was recommended method for primary repair and early rehabilization of achilles tendon ruptue.

  • PDF

Evaluation of reverse torque value of abutment screws on CAD/CAM custom-made implant abutments (CAD/CAM을 이용한 맞춤형 임플란트 지대주의 나사 풀림 토크 평가)

  • Lee, Chang-Jae;Yang, Sung-Eun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.128-134
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the screw joint stability between the CADCAM custom-made implant abutment and the prefabricated implant abutment by measuring the reverse torque value after cyclic loading. Materials and methods: Twelve screw type implants (Implantium, Dentium Co., Seoul, Korea) were embedded in aluminum cylinder with acrylic resin. The implant specimens were equally divided into 3 groups, and connected to the prefabricated titanium abutments (Implantium, Dentium Co., Seoul, Korea), CADCAM custom-made titanium abutments (Myplant, Raphabio Co., Seoul, Korea) and CADCAM custom-made zirconia abutments (Zirconia Myplant, Raphabio Co., Seoul, Korea). The CAD-CAM milled titanium crown (Raphabio Co., Seoul, Korea) was cemented on each implant abutment by resin cement. Before cyclic loading, each abutment screw was tightened to 30 Ncm and the reverse torque value was measured about 30 minutes later. After the crown specimen was subjected to the sinusoidal cyclic loading (30 to 120 N, 500,000 cycles, 2 Hz), postloading reverse torque value was measured and the reverse torque loss ratio was calculated. Kruskal-Wallis test was used for statistical analysis of the reverse torque loss ratio. Results: The CADCAM custom-made titanium abutments presented higher values in reverse torque loss ratio without statistically significant differences than the prefabricated titanium abutments ($P$>.05). Reverse torque loss ratio of the custom-made zirconia abutments was significantly higher compared to that of the prefabricated titanium abutments ($P$=.014). Conclusion: Within the limitation of the present $in-vitro$ study, it was concluded that there was no significant difference in screw joint stability between the CADCAM custom-made titanium abutments and the prefabricated titanium abutments. On the other hand, the CADCAM custom-made zirconia abutments showed lower screw joint stability than prefabricated titanium abutments.

In Vitro Study on the Initial Stability of Two Tapered Dental Implant Systems in Poor Bone Quality (연질 골에서 두 종류의 테이퍼 형태 임플란트의 초기 안정성에 관한 실험실적 연구)

  • Kim, Duck-Rae;Kim, Myung-Joo;Kwon, Ho-Beom;Lee, Seok-Hyung;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.391-401
    • /
    • 2009
  • The successful outcome of dental implants is mainly the result of intial implant stability following placement. The aim of this study was to investigate the effect of a self-tapping blades and implant design on initial stability of two tapered implant systems in poor bone quality. The two different implant systems included one with self-tapping blades and one without self-tapping blades. D4 bone model using Solid Rigid Polyurethane Form was used to simulate poor bone densities. The insertion torque during implant placement was recorded. Resonance frequency Analysis (RFA), measured as the implant stability quotient (ISQ), was assessed immediately after insertion. Finally, the implant-bone specimen was transferred to an Universal Testing Machine to measure the axial pull-out force. Insertion torque values and maximum pull-out torque value of the non self-tapping implants were significantly higher than those in the self-tapping group (P = 0.008). No statistically differences were noted between the two implant designs in RFA. Within the each implant system, no correlation among insertion torque, maximum pull-out torque and RFA value could be determined. Higher insertion torque of the non-self-tapping implants appeared to confirm higher clinical initial stability. In conclusion, implants without self-tapping blades have higher initial stability than implants with self-tapping blades in poor bone quality.

Vertebral Distraction during Anterior Cervical Discectomy and Fusion Causes Postoperative Neck Pain

  • Ha, Seung Man;Kim, Jeong Hoon;Oh, Seung Hun;Song, Ji Hwan;Kim, Hyoung Ihl;Shin, Dong Ah
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.5
    • /
    • pp.288-292
    • /
    • 2013
  • Objective : Vertebral distraction is routinely performed during anterior cervical discectomy and fusion (ACDF). Overdistraction can injure the facet joints and may cause postoperative neck pain consequently. The purpose of this study was to investigate the clinical relevance of distraction force during ACDF. Methods : This study included 24 consecutive patients with single level cervical disc disease undergoing single level ACDF. We measure the maximum torque just before the the arm of the Caspar retractor was suspended by the rachet mechanism by turning the lever on the movable arm using a torque meter. In order to turn the lever using the torque driver, we made a linear groove on the top of the lever. We compared the neck disability index (NDI) and visual analogue scale (VAS) scores between the high torque group (distraction force>6 $kgf{\cdot}cm$) and the low torque group (distraction force${\leq}6kgf{\cdot}cm$) at routine postoperative intervals of 1, 3, 5 days and 1, 3, 6 months. Results : The VAS scores for posterior neck pain had a linear correlation with torque at postoperative 1st and 3rd days ($y=0.99{\times}-1.1$, $r^2=0.82$; $y=0.77{\times}-0.63$, $r^2=0.73$, respectively). VAS scores for posterior neck pain were lower in the low torque group than in the high torque group on both 1 and 3 days postoperatively ($3.1{\pm}1.3$, $2.6{\pm}1.0$ compared with $6.0{\pm}0.6$, $4.9{\pm}0.8$, p<0.01). However, the difference in NDI scores was not statistically significant in all postoperative periods. Conclusion : Vertebral distraction may cause posterior neck pain in the immediate postoperative days. We recommend not to distract the intervertebral disc space excessively with a force of more than 6.0 $kgf{\cdot}cm$.

In Vitro Assessment of MRI Safety at 1.5 T and 3.0 T for Bone-Anchored Hearing Aid Implant (Bone-Anchored Hearing Aid Implant에 대한 1.5 T와 3.0 T에서 MRI 안전성의 생체외 평가)

  • Yeon, Kyoo-Jin;Kim, Hyun-Soo;Lee, Seung-keun;Lee, Tae-Soo
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.19-25
    • /
    • 2017
  • The aim of this study was to evaluate Magnetic Resonance Imaging safety by measuring the translational attraction, torque and susceptibility artifact for Bone-Anchored Hearing Aid (BAHA) implant at 1.5 T and 3.0 T MRI by standard criteria. In vitro assessment tools were made of acrylic-resin by American Society for Testing and Materials (ASTM) F2052-06 and F2119-07 standard. Translational attraction of BAHA implant was measured by the maximum deflection angle at 96 cm position, where the magnetically induced deflection was the greatest. The torque was assessed by the qualitative criteria of evaluating the alignment and rotation pattern, when the BAHA implant was positioned on a line with $45^{\circ}$ intervals inside the circular container in the center of the bore. The susceptibility artifact images were obtained using the hanged test tool, which was filled with $CuSO_4$ solution. And then the artifact size was measured using Susceptibility A rtifact Measurement (SA M) software. In results, the translational attraction was 0 mm at both 1.5 T and 3.0 T and the torque was 0(no torque) at 1.5 T, and +1(mild torque) at 3.0 T. The size of susceptibility artifacts was between 13.20 mm and 38.91 mm. Therefore, The BAHA implant was safe for the patient in clinical MR environment.

A study on accuracy and application of the implant torque controller used in dental clinic (임상에서 사용하고 있는 임플란트 토크조절기의 정확도와 적용에 관한 사용실태)

  • Joo, Young-Hun;Lee, Jin-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.197-205
    • /
    • 2011
  • Purpose: This study was to evaluate the accuracy of the implant torque controller used in dental clinics and to investigate whether it was applied appropriately. Materials and methods: Fifty dentists who work in dental clinics were enrolled in this study. Dental (implant) practice career, experience frequency of implant screw loosening and fracture, education of implant torque controller application and infection control methods were included in the survey. 25 Ncm and 30 Ncm of the tightening torque applied to the implant screw were measured by 50 clinicians. After measuring the torque value by using the torque controller, the torque mean according to where education about the implant torque controller was received was analyzed with independent t-test at the significance level of 0.05. Results: The torque controller used in private dental clinics showed 4.78% error ratio. When 50 dentists applied 25 Ncm to the implant screw was $29.0{\pm}8.4$ Ncm, and that in 30 Ncm was $34.3{\pm}9.1$ Ncm. Statistical significance was found between the group that was educated about implant torque application and the group that was not educated. Conclusion: During the prosthodontic treatment with implant, there was difference between actual applied torsion force and the amount torque controller indicated. Clinicians have to not only be well-informed about the accurate usage method of the torque controller, but also keep and manage the torque controller so as to maintain continuous and accurate torque values. Through this, it is considered to achieve clinical results to minimize problems of screw loosening or fracture.

Screw Loosening of Various Implant Systems (수종의 임플랜트 시스템의 나사풀림에 관한 연구)

  • Ahn, Jin-Soo;Cho, In-Ho;Lim, Ju-Hwan;Lim, Heon-Song
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.2
    • /
    • pp.81-91
    • /
    • 2002
  • Dental implant systems have shown many post-surgical problems and One of the most frequent problem is screw loosening. To reduce screw loosening, a number of methods have been tried and recently fundamental modification of fixture-abutment connection structure was developed and used the most frequently. Former implant system structure, such as Br${\aa}$nemark, had external hex with the height of 0.7 mm and later, fixture with external hex of 1.0 mm height and internal hex structure were developed. In addition, the method of morse taper application was introduced to reduce screw loosening. In this study, the level of screw loosening of each implant systems was compared based on the vibration loosening measurement of abutment screw of each implant systems. Analysis of measured value was performed using 3 kinds of methods, (i) Percentage of average of initial 3 times loosening-torque value(initial loosening value) to tightening-torque of 30 Ncm, (ii) Percentage of loosening-torque value after 200 N strength loaded(experimental value) to initial loosening value and (iii) Percentage of experimental value to 30 Ncm of tightening-torque. Each result of analyses shows the value of initial loosening, loosening by repetitive load and final loosening level. The results of this study were as follows. (1) Percentage of initial loosening value to tightening-torque was increased in order of 0.7 mm external hex, 1.0 mm external hex, internal hex and internal taper and all values between each groups showed statistical significance (p<0.05). (2) Percentage of experimental value to initial loosening value was increased in order of internal hex, 0.7 mm external hex, 1.0 mm external hex and internal taper. Value of internal taper showed significant difference with that of 0.7 mm external hex and internal hex (p<0.05). (3) Percentage of experimental value to tightening torque was increased in order of 0.7 mm external hex, 1.0 mm external hex, internal hex and internal taper. Values of all groups showed statistical significance (p<0.05) except between the groups of 1.0 mm external hex and internal hex. Based on those results, there was no significant difference of loosening-torque by repetitive loading except internal taper. It is supposed that implant system with high resistant capability against initial loosening could be recommended for clinical use. In addition, in case of single implant restoration, 1.0 mm external hex or internal hex could be recommended rather than 0.7 mm external hex, and the use of internal taper would be the most useful way to reduce screw loosening.

Screw loosening and changes in removal torque relative to abutment screw length in a dental implant with external abutment connection after oblique cyclic loading

  • Lee, Joo-Hee;Cha, Hyun-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.6
    • /
    • pp.415-421
    • /
    • 2018
  • PURPOSE. This study investigated the effects of abutment screw lengths on screw loosening and removal torque in external connection implants after oblique cyclic loading. MATERIALS AND METHODS. External connection implants were secured with abutment screws to straight abutments. The abutment-implant assemblies were classified into seven groups based on the abutment screw length, with each group consisting of five assemblies. A cyclic load of 300 N was applied at a $30^{\circ}$ angle to the loading axis until one million cycles were achieved. Removal torque values (RTVs) before and after loading, and RTV differences were evaluated. The measured values were analyzed using repeated measures of analysis of variance with the Student-Newman-Keuls multiple comparisons. RESULTS. All assemblies survived the oblique cyclic loading test without screw loosening. There was a significant decrease in the RTVs throughout the observed abutment screw lengths when the abutment-implant assemblies were loaded repeatedly (P<.001). However, the abutment screw length did not show significant difference on the RTVs before and after the experiment when the abutment screw length ranged from 1.4 to 3.8 mm (P=.647). CONCLUSION. Within the limit of this experiment, our results indicate that the abutment screw length did not significantly affect RTV differences after oblique cyclic loading when a minimum length of 1.4 mm (3.5 threads) was engaged. These findings suggest that short abutment screws may yield stable clinical outcomes comparable to long screws in terms of load resistance.