• 제목/요약/키워드: Clinical target volume

검색결과 141건 처리시간 0.03초

Dose Planning Study of Target Volume Coverage with Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma: Penang General Hospital Experience

  • Vincent Phua, Chee Ee;Tan, Boon Seang;Tan, Ai Lian;Eng, Kae Yann;Ng, Bong Seng;Ung, Ngie Min
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권4호
    • /
    • pp.2243-2248
    • /
    • 2013
  • Background: To compare the dosimetric coverage of target volumes and organs at risk in the radical treatment of nasopharyngeal carcinoma (NPC) between intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3DCRT). Materials and Methods: Data from 10 consecutive patients treated with IMRT from June-October 2011 in Penang General Hospital were collected retrospectively for analysis. For each patient, dose volume histograms were generated for both the IMRT and 3DCRT plans using a total dose of 70Gy. Comparison of the plans was accomplished by comparing the target volume coverage (5 measures) and sparing of organs at risk (17 organs) for each patient using both IMRT and 3DCRT. The means of each comparison target volume coverage measures and organs at risk measures were obtained and tested for statistical significance using the paired Student t-test. Results: All 5 measures for target volume coverage showed marked dosimetric superiority of IMRT over 3DCRT. V70 and V66.5 for PTV70 showed an absolute improvement of 39.3% and 24.1% respectively. V59.4 and V56.4 for PTV59.4 showed advantages of 18.4% and 16.4%. Moreover, the mean PTV70 dose revealed a 5.1 Gy higher dose with IMRT. Only 4 out of 17 organs at risk showed statistically significant difference in their means which were clinically meaningful between the IMRT and 3DCRT techniques. IMRT was superior in sparing the spinal cord (less 5.8Gy), V30 of right parotid (less 14.3%) and V30 of the left parotid (less 13.1%). The V55 of the left cochlea was lower with 3DCRT (less 44.3%). Conclusions: IMRT is superior to 3DCRT due to its dosimetric advantage in target volume coverage while delivering acceptable doses to organs at risk. A total dose of 70Gy with IMRT should be considered as a standard of care for radical treatment of NPC.

Radial displacement of clinical target volume in node negative head and neck cancer

  • Jeon, Wan;Wu, Hong-Gyun;Song, Sang-Hyuk;Kim, Jung-In
    • Radiation Oncology Journal
    • /
    • 제30권1호
    • /
    • pp.36-42
    • /
    • 2012
  • Purpose: To evaluate the radial displacement of clinical target volume in the patients with node negative head and neck (H&N) cancer and to quantify the relative positional changes compared to that of normal healthy volunteers. Materials and Methods: Three node-negative H&N cancer patients and five healthy volunteers were enrolled in this study. For setup accuracy, neck thermoplastic masks and laser alignment were used in each of the acquired computed tomography (CT) images. Both groups had total three sequential CT images in every two weeks. The lymph node (LN) level of the neck was delineated based on the Radiation Therapy Oncology Group (RTOG) consensus guideline by one physician. We use the second cervical vertebra body as a reference point to match each CT image set. Each of the sequential CT images and delineated neck LN levels were fused with the primary image, then maximal radial displacement was measured at 1.5 cm intervals from skull base (SB) to caudal margin of LN level V, and the volume differences at each node level were quantified. Results: The mean radial displacements were 2.26 (${\pm}1.03$) mm in the control group and 3.05 (${\pm}1.97$) in the H&N cancer patients. There was a statistically significant difference between the groups in terms of the mean radial displacement (p = 0.03). In addition, the mean radial displacement increased with the distance from SB. As for the mean volume differences, there was no statistical significance between the two groups. Conclusion: This study suggests that a more generous radial margin should be applied to the lower part of the neck LN for better clinical target coverage and dose delivery.

Failure patterns of cervical lymph nodes in metastases of unknown origin according to target volume

  • Kim, Dong-Yun;Heo, Dae Seog;Keam, Bhumsuk;Ock, Chan Young;Ahn, Soon Hyun;Kim, Ji-hoon;Jung, Kyeong Cheon;Kim, Jin Ho;Wu, Hong-Gyun
    • Radiation Oncology Journal
    • /
    • 제38권1호
    • /
    • pp.18-25
    • /
    • 2020
  • Purpose: This study was aim to evaluate the patterns of failure according to radiotherapy (RT) target volume for cervical lymph nodes in metastases of unknown primary origin in head and neck region (HNMUO). Materials and Methods: Sixty-two patients with HNMUO between 1998 and 2016 were retrospectively reviewed. We analyzed the clinical outcomes and primary site failure depending on the radiation target volume. The target volume was classified according to whether the potential head and neck mucosal sites were included and whether the neck node was treated involved side only or bilaterally. Results: Potential mucosal site RT (mucosal RT) was done to 23 patients and 39 patients did not receive mucosal RT. Mucosal RT showed no significant effect on overall survival (OS) and locoregional recurrence (LRR). The location of primary site failure encountered during follow-up period was found to be unpredictable and 75% of patients with recurrence received successful salvage therapies. No significant differences in OS and LRR were found between patients treated to unilateral (n = 35) and bilateral neck irradiation (n = 21). Treatment of both necks resulted in significantly higher mucositis. Conclusions: We found no advantages in OS and LRR of patients with HNMUO when mucosal sites and bilateral neck node were included in the radiation target volume.

아주대학교병원에서의 전립선암에 대한 래피드아크 치료 (First Clinical Experience about RapidArc Treatment with Prostate Cancer in Ajou University Hospital)

  • 박혜진;김미화;전미선;오영택;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제21권2호
    • /
    • pp.183-191
    • /
    • 2010
  • 본 논문에서는 세기조절방사선치료와 이중회전(double arcs)을 통한 래피드아크 치료용 치료계획을 수행하였고, 각각의 선량분포와 DVH의 특성을 비교, 평가하였다. 또한 정도관리를 통해 래피드아크 치료에 대한 신뢰도 및 정확도를 평가하고 이러한 과정들을 통해 환자에 대한 적절한 치료방법을 제시하고자 하였다. 두 치료기술에 대한 치료계획 시 임상표적 용적(Clinical Target Volume, CTV)과 치료표적용적(Planning Target Volume, PTV)과 직장에 동일한 최적화 조건을 적용하였고, 그 외 정상조직에 대하여 최적화 조건 없이 가장 단순화한 조건에서 최적화의 능력과 결과 차이를 비교하였다. 래피드아크는 세기조절방사선치료와 비교하였을 때 동일한 선량제한치 적용 후 결과는 종양에 전달되는 선량은 증가하고 손상위험장기에 대해서는 더 보호하는 능력을 보여주고 있다. 따라서 세기조절방사선치료와 비교하였을 때 치료부피와 주변 장기의 부작용에 대하여 주변장기에 대한 조사선량은 줄이면서 종양에는 더 많은 선량이 조사되었다. 본 연구를 통하여 래피드아크 치료는 기존에 시행하고 있는 세기조절방사선치료 기법보다 더욱 최적의 선량 분포를 구현하고, 치료시간에 있어 보다 효율적이라는 것을 알 수 있었다. 그리고 정밀한 치료 기법인 만큼 정확한 래피드아크 치료를 시행하기 위해서는 치료 계획과 실제로 시행되는 치료가 일치하는지 확인하는 정도관리 과정이 반드시 필요하다는 것을 알 수 있었다.

Interobserver variation in target volume for salvage radiotherapy in recurrent prostate cancer patients after radical prostatectomy using CT versus combined CT and MRI: a multicenter study (KROG 13-11)

  • Lee, Eonju;Park, Won;Ahn, Sung Hwan;Cho, Jae Ho;Kim, Jin Hee;Cho, Kwan Ho;Choi, Young Min;Kim, Jae-Sung;Kim, Jin Ho;Jang, Hong-Seok;Kim, Young-Seok;Nam, Taek-Keun
    • Radiation Oncology Journal
    • /
    • 제36권1호
    • /
    • pp.11-16
    • /
    • 2018
  • Purpose: To investigate interobserver variation in target volume delineations for prostate cancer salvage radiotherapy using planning computed tomography (CT) versus combined planning CT and magnetic resonance imaging (MRI). Materials and Methods: Ten radiation oncologists independently delineated a target volume on the planning CT scans of five cases with different pathological status after radical prostatectomy. Two weeks later, this was repeated with the addition of planning MRI. The volumes obtained with CT only and combined CT and MRI were compared, and the effect of the addition of planning MRI on interobserver variability was assessed. Results: There were large differences in clinical target volume (CTV) delineated by each observer, regardless of the addition of planning MRI ($9.44-139.27cm^3$ in CT only and $7.77-122.83cm^3$ in CT plus MRI) and no significant differences in the mean and standard deviation of CTV. However, there were decreases in mean volume and standard deviation as a result of using the planning MRI. Conclusion: This study showed substantial interobserver variation in target volume delineation for salvage radiotherapy. The combination of planning MRI with CT tended to decrease the target volume and the variation.

좌측 유방암 방사선 치료 시 치료 기법에 따른 선량적 고찰 (The dosimetric guide of treatment modalities for Left side breast irradiation after conservative surgery)

  • 김태민;문성공;김이지;김세영;박령황;김주호;조정희
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.153-160
    • /
    • 2018
  • 목 적 : 부분절제술 시행 후 좌측 유방암 환자의 방사선 치료 시 적용된 각 방사선 치료 기법 별 선량을 후향적으로 분석하여 정상장기와 종양용적의 선량적 결과를 전형적인 분할치료 선량(EQD2)을 고려한 선량 결과를 도출함으로써 임상적 참고 지표로 활용하고자 한다. 대상 및 방법 : 본원에서 시행한 좌측 유방암 환자 중 부분절제술을 시행한 40명을 대상으로 3가지의 치료기법으로 구분하여 적용하였다. 각 치료법의 총 종양용적과 임상적 표적용적에서 HI(homogeneity index), $D_{95%}$, 그리고 CI(conformity index)값, 그리고 $V_{hot}$ 수치를 도출한 후 치료계획을 평가하였다. 사이버나이프를 이용한 경우 종양용적은 타 기법에서의 고선량 용적과 동일하여 임상적 표적용적는 고려하지 않았다. 정상장기에 대한 평가는 평균선량을 비교하였다. 결 과 : 세가지 치료법의 HI는 3D-CRT, VMAT, RIMRT 모두 큰 차이를 보이지 않았다. 체적조절 호형 방사선치료(VMAT)을 이용한 치료의 경우 임상적 표적용적의 $D_{95%}$의 경우 $95.84{\pm}0.75%$로 3차원 입체조형 방사선 치료(3D-CRT) 치료법에 비해 높은 값을 나타냈다. 총 종양용적의 $D_{95%}$값은 다른 치료법들에 비해 미세하게 높은 결과를 보여줬다. 사이버나이프를 이용한 치료법은 정상장기들에 조사되는 선량이 타 치료법에 비해 현저하게 낮았다. 결 론 : 3D-CRT의 경우 DIBH를 동반하여 치료할 경우 전반적으로 심장을 보호하는데 유용한 치료 기법이며 VMAT의 경우 탁월한 TARGET COVERAGE를 나타내지만 저 선량 영역이 타 기법에 비해 넓은 것을 알 수 있다. 그러나 앞선 두 가지 치료법에서 치료계획 평가를 위한 대부분의 선량적 지표에서 비슷한 값을 보여 치료 계획 결과 및 평가에서는 큰 차이가 없는 것으로 환자의 해부학적 구조나 호흡 조절 가능 유무에 따라 치료기법 선택이 가능할 것으로 사료된다. 사이버나이프를 이용한 치료의 경우 종양용적에 정확한 고 선량을 주며 정상장기 보호에 매우 유용한 치료법이지만 국소부위 치료만 가능한 점, 치료시간이 상대적으로 긴 점, 치료 전 침습적 시술인 금침 삽입술을 해야 하는 제약이 있다.

  • PDF

A Method for Estimating the Lung Clinical Target Volume DVH from IMRT with and without Respiratory Gating

  • J. H. Kung;P. Zygmanski;Park, N.;G. T. Y. Chen
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.53-60
    • /
    • 2002
  • Motion of lung tumors from respiration has been reported in the literature to be as large as of 1-2 cm. This motion requires an additional margin between the Clinical Target Volume (CTV) and the Planning Target Volume (PTV). While such a margin is necessary, it may not be sufficient to ensure proper delivery of Intensity Modulated Radiotherapy (IMRT) to the CTV during the simultaneous movement of the DMLC. Gated treatment has been proposed to improve normal tissues sparing as well as to ensure accurate dose coverage of the tumor volume. The following questions have not been addressed in the literature: a) what is the dose error to a target volume without gated IMRT treatment\ulcorner b) what is an acceptable gating window for such treatment. In this study, we address these questions by proposing a novel technique for calculating the 3D dose error that would result if a lung IMRT plan were delivered without gating. The method is also generalized for gated treatment with an arbitrary triggering window. IMRT plans for three patients with lung tumor were studied. The treatment plans were generated with HELIOS for delivery with 6 MV on a CL2100 Varian linear accelerator with a 26 pair MLC. A CTV to PTV margin of 1 cm was used. An IMRT planning system searches for an optimized fluence map ${\Phi}$ (x,y) for each port, which is then converted into a dynamic MLC file (DMLC). The DMLC file contains information about MLC subfield shapes and the fractional Monitor Units (MUs) to be delivered for each subfield. With a lung tumor, a CTV that executes a quasi periodic motion z(t) does not receive ${\Phi}$ (x,y), but rather an Effective Incident Fluence EIF(x,y). We numerically evaluate the EIF(x,y) from a given DMLC file by a coordinate transformation to the Target's Eye View (TEV). In the TEV coordinate system, the CTV itself is stationary, and the MLC is seen to execute a motion -z(t) that is superimposed on the DMLC motion. The resulting EIF(x,y)is inputted back into the dose calculation engine to estimate the 3D dose to a moving CTV. In this study, we model respiratory motion as a sinusoidal function with an amplitude of 10 mm in the superior-inferior direction, a period of 5 seconds, and an initial phase of zero.

  • PDF

소용량 Vancomycin 주사액 조제방법의 차이에 의한 정확성 비교: 단일희석방법과 이중희석방법 (The Comparison of the Accuracy in Preparing Small Vancomycin Dosage : Single vs. Double Dilution Method)

  • 신혜영;서옥경;이숙향;신현택
    • 한국임상약학회지
    • /
    • 제7권2호
    • /
    • pp.86-90
    • /
    • 1997
  • This study was to find a more accurate method fur measuring small vancomycin dosages which are commonly used in neonates by comparing single and double dilution method. For single dilution method, 500 mg of vancomycin powder was accurately measured and reconstituted with 5 ml of distilled water to make a concentration of 100 mg/ml. Volumes of 0.05, 0.1, 0.15, 0.2, 0.3, 0.4, and 0.5 ml, which equal the target dosages of 5, 10, 15, 20, 30, 40, and 50 mg, were measured using syringes made by Shina and each sample was further diluted with 2 ml of $5\%$ dextrose. The solution of 100 mg/ml concentration was further diluted with $5\%$ dextrose to make a concentration of 20 mg/ml. Volumes of 0.25, 0.5, 0.75, 1.0, 1.5, 2.0, and 2.5 ml, which correspond to 5, 10, 15, 20, 30, 40, and 50 mg, were sampled by the same Shina's syringe as in single dilution method and then each sample was further diluted to make a total volume of 10 ml. Each sample was analyzed by HPLC. The measured dosages of each sample in both single and double dilution methods were lower than the target dosages; however, e values in double dilution method were higher than those in single dilution method for seven target dosages. Percent target dosages in single dilution method were 65 to $90\%$, while in double dilution method 91 to $94\%$. Statistically significant difference between two groups was shown in 5, 10, 15, 20, and 40 mg dosages (p<0.05). In conclusion, when preparing small vancomycin dosages lower an 20 mg $(volume{\leq}0.2\;ml)$, using Shina's syringes, the double dilution method has a closer value to the target dosage than single dilution method.

  • PDF

Efficient approach for determining four-dimensional computed tomography-based internal target volume in stereotactic radiotherapy of lung cancer

  • Yeo, Seung-Gu;Kim, Eun Seog
    • Radiation Oncology Journal
    • /
    • 제31권4호
    • /
    • pp.247-251
    • /
    • 2013
  • Purpose: This study aimed to investigate efficient approaches for determining internal target volume (ITV) from four-dimensional computed tomography (4D CT) images used in stereotactic body radiotherapy (SBRT) for patients with early-stage non-small cell lung cancer (NSCLC). Materials and Methods: 4D CT images were analyzed for 15 patients who received SBRT for stage I NSCLC. Three different ITVs were determined as follows: combining clinical target volume (CTV) from all 10 respiratory phases ($ITV_{10Phases}$); combining CTV from four respiratory phases, including two extreme phases (0% and 50%) plus two intermediate phases (20% and 70%) ($ITV_{4Phases}$); and combining CTV from two extreme phases ($ITV_{2Phases}$). The matching index (MI) of $ITV_{4Phases}$ and $ITV_{2Phases}$ was defined as the ratio of $ITV_{4Phases}$ and $ITV_{2Phases}$, respectively, to the $ITV_{10Phases}$. The tumor motion index (TMI) was defined as the ratio of $ITV_{10Phases}$ to $CTV_{mean}$, which was the mean of 10 CTVs delineated on 10 respiratory phases. Results: The ITVs were significantly different in the order of $ITV_{10Phases}$, $ITV_{4Phases}$, and $ITV_{2Phases}$ (all p < 0.05). The MI of $ITV_{4Phases}$ was significantly higher than that of $ITV_{2Phases}$ (p < 0.001). The MI of $ITV_{4Phases}$ was inversely related to TMI (r = -0.569, p = 0.034). In a subgroup with low TMI (n = 7), $ITV_{4Phases}$ was not statistically different from $ITV_{10Phases}$ (p = 0.192) and its MI was significantly higher than that of $ITV_{2Phases}$ (p = 0.016). Conclusion: The $ITV_{4Phases}$ may be an efficient approach alternative to optimal $ITV_{10Phases}$ in SBRT for early-stage NSCLC with less tumor motion.