• Title/Summary/Keyword: Clinical Dentistry

Search Result 4,621, Processing Time 0.029 seconds

Evaluation of functional suitable digital complete denture system based on 3D printing technology

  • Deng, Kehui;Chen, Hu;Wang, Yong;Zhou, Yongsheng;Sun, Yuchun
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.361-372
    • /
    • 2021
  • PURPOSE. To improve the clinical effects of complete denture use and simplify its clinical application, a digital complete denture restoration workflow (Functional Suitable Digital Complete Denture System, FSD) was proposed and preliminary clinical evaluation was done. MATERIALS AND METHODS. Forty edentulous patients were enrolled, of which half were treated by a prosthodontic chief physician, and the others were treated by a postgraduate student. Based on the primary impression and jaw relation obtained at the first visit, diagnostic denture was designed and printed to create a definitive impression, jaw relation, and esthetic confirmation at the second visit. A redesigned complete denture was printed as a mold to fabricate final denture that was delivered at the third visit. To evaluate accuracy of impression made by diagnostic denture, the final denture was used as a tray to make impression, and 3D comparison was used to analyze their difference. To evaluate the clinical effect of FSD, visual analogue scores (VAS) were determined by both dentists and patients. RESULTS. Two visits were reduced before denture delivery. The RMS values of 3D comparison between the impression made via diagnostic dentures and the final dentures were 0.165 ± 0.033 mm in the upper jaw and 0.139 ± 0.031 mm in the lower jaw. VAS ratings were between 8.5 and 9.6 in the chief physician group, while 7.7 and 9.5 in the student group; there was no statistical difference between the two groups. CONCLUSION. FSD can simplify the complete denture restoration process and reduce the number of visits. The accuracy of impressions made by diagnostic dentures was acceptable in clinic. The VASs of both dentists and patients were satisfied.

The status of clinical practice for students in the department of dental hygiene (치위생과 학생의 임상실습 교육 실태에 관한 조사연구)

  • Kim, Jeong-Suk;Kang, Eun-Ju;Kim, Sun-Ju
    • Journal of Korean society of Dental Hygiene
    • /
    • v.9 no.3
    • /
    • pp.439-455
    • /
    • 2009
  • The number of dental hygiene students is increasing as dental hygiene departments are extended or newly installed continuously, and in other to keep up with the quantitative increase, we need to standardize dental hygiene curriculums. The present study conducted a questionnaire survey with dental hygiene students who had completed clinical practice. The obtained results as follows. 1. According to the contents of clinical practice at dental clinics, the frequency of dental hygiene students' observation practice was high in basic medical service, dental prosthesis, and orthodontics. 2. The frequency of performance practice was high in basic medical service, oral medicine, preventive dentistry, pediatric dentistry, periodontology, and oral surgery. According to the area of clinical practice. 3. According to the contents of clinical practice at university hospitals, the frequency of dental hygiene students' observation practice was high in basic medical service, dental prosthesis, and orthodontics. 4. The frequency of performance practice was high in basic medical service, oral medicine, preventive dentistry, pediatric dentistry, periodontology, and dental prosthesis. 5. The students' satisfaction was high in basic medical service, oral medicine, preventive dentistry, and periodontology. The period of clinical practice varies according to school curriculum and circumstance among dental clinics and university hospitals where clinical practices are performed, students' satisfaction with their observation practice and performance practice may be different. Thus, for dental hygiene students' clinical practice, it is considered desirable to prepare integrated education programs that standardize the period and contents of clinical practice.

  • PDF

Effects of different surface finishing procedures on the change in surface roughness and color of a polymer infiltrated ceramic network material

  • Ozarslan, Mehmet Mustafa;Buyukaplan, Ulviye Sbnem;Barutcigil, Cagtay;Arslan, Merve;Tuker, Nurullah;Barutcigil, Kubilay
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.16-20
    • /
    • 2016
  • PURPOSE. Polymer infiltrated ceramic network (PICN) materials, also called hybrid ceramics, are new materials in dental market. The manufacturer of the PICN material VITA Enamic suggests 3 different finishing procedures for this new material. In the present study, surface roughness and color differences caused from different finishing procedures of VITA Enamic were investigated. MATERIALS AND METHODS. 120 specimens were prepared in dimensions $2{\times}10{\times}12mm$ from VITA Enamic hybrid ceramic blocks with 'high translucency' and 'translucency 2M2' shades. The specimens were divided into 8 groups. For each group, different finishing procedures suggested by the manufacturer were performed. Surface roughness values were determined by a tactile portable profilometer. Color changes were evaluated using a clinical spectrophotometer. The data were analyzed using one-way ANOVA and Tukey's post-hoc comparison. The significance level was set at ${\alpha}=0.05$. RESULTS. The roughest surfaces were observed in Glaze Groups. Their surface roughness values were similar to that of the control group. Clinical Kit and Technical Kit groups did not show a statistically significant difference regarding surface roughness (P>.05). The largest color difference regarding ${\Delta}E_{00}$ was observed in Clinical Kit finishing groups. There were also statistically significant color changes between the groups (P<.05). However, all the groups showed clinically acceptable color change (${\Delta}E_{00}$<2.25) except Clinical Kit Groups (${\Delta}E_{00}$>2.25). CONCLUSION. Within the limitations of the present study, it may be suggested that finishing the VITA Enamic restorations by Technical Kit instead of Glaze and Clinical Kit gives better clinical performance in regard to surface roughness and shade matching.

Positioning errors of dental implants and their associations with adjacent structures and anatomical variations: A CBCT-based study

  • Ribas, Beatriz Ribeiro;Nascimento, Eduarda Helena Leandro;Freitas, Deborah Queiroz;Pontual, Andrea dos Anjos;Pontual, Maria Luiza dos Anjos;Perez, Danyel Elias Cruz;Ramos-Perez, Flavia Maria Moraes
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.281-290
    • /
    • 2020
  • Purpose: The objective of the present study was to evaluate the prevalence of dental implants positioning errors and their associations with adjacent structures and anatomical variations by means of cone-beam computed tomography (CBCT). Materials and Methods: CBCT images of 207 patients (584 dental implants) were evaluated by 2 oral radiologists. The distance between the implant and the adjacent teeth/implants was measured and classified as adequate (≥1.5 mm and ≥3 mm, respectively) or inadequate. The presence of thread exposure, cortical perforation, implant dehiscence, implant penetration into adjacent structures, and anatomical variations was also recorded. The incisor canal diameter and the depth of the concavity of the submandibular fossa were measured in order to evaluate their correlations with the frequency of implant penetration in these structures. Descriptive analyses, the Fisher exact test, and Spearman correlation analysis were performed (α=0.05). Results: The overall prevalence of positioning errors was 82.9%. The most common error was the inadequate distance between the implant and the adjacent teeth/implants. The presence of anatomical variations did not significantly influence the overall prevalence of errors (P>0.05). There was a positive correlation between the diameter of the incisor canal and the frequency of implant penetration in this structure (r=0.232, P<0.05). Conclusion: There was a high prevalence of dental implant positioning errors, and positioning errors were not associated with the presence of anatomical variations. Professionals should be aware of the space available for implant placement during the preoperative planning stage.

Soft and Hard Tissue Augmentation with/without Polydeoxyribonucleotide for Horizontal Ridge Deficiency: A Pilot Study in a Dog Model

  • Hyunwoo Lim;Yeek Herr;Jong-Hyuk Chung;Seung-Yun Shin;Seung-Il Shin;Ji-Youn Hong;Hyun-Chang Lim
    • Journal of Korean Dental Science
    • /
    • v.17 no.2
    • /
    • pp.53-63
    • /
    • 2024
  • Purpose: To investigate the effects of simultaneous soft and hard tissue augmentation and the addition of polydeoxyribonucleotide (PDRN) on regenerative outcomes. Materials and Methods: In five mongrel dogs, chronic ridge defects were established in both mandibles. Six implants were placed in the mandible, producing buccal dehiscence defects. The implants were randomly allocated to one of the following groups: 1) control: no treatment; 2) GBR: guided bone regeneration (GBR) only; 3) GBR/PDRN: GBR+PDRN application to bone substitute particles; 4) GBR/CTG: GBR+connective tissue grafting (CTG); 5) GBR/VCMX: GBR+soft tissue augmentation using volume stable collagen matrix (VCMX); and 6) group GBR/VCMX/PDRN: GBR+VCMX soaked with PDRN. The healing abutments were connected to the implants to provide additional room for tissue regeneration. Submerged healing was achieved. The animals were euthanized after four months. Histological and histomorphometric analyses were then performed. Results: Healing abutments were gradually exposed during the healing period. Histologically, minimal new bone formation was observed in the dehiscence defects. No specific differences were found between the groups regarding collagen fiber orientation and density in the augmented area. No traces of CTG or VCMX were detected. Histomorphometrically, the mean tissue thickness was greater in the control group than in the other groups above the implant shoulder (IS). Below the IS level, the CTG and PDRN groups exhibited more favorable tissue thickness than the other groups. Conclusion: Failure of submerged healing after tissue augmentation deteriorated the tissue contour. PDRN appears to have a positive effect on soft tissues.

APPLICATION OF DUAL PARAMETER ANALYSIS IN FLOW CYTOMETRIC DNA MEASUREMENTS OF ORAL SQUAMOUS CELL CARCINOMA (구강편평세포암종의 유세포분석적 DNA측정을 위한 이중 매개변수법의 적용)

  • Kim, Su-Ya;Ju, Hoon;Kim, Jae-Gon;Cho, Nam-Pyo;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.503-524
    • /
    • 1996
  • A series of 31 patients with primary oral squamous cell carcinoma (SCC) who were treated at Chonbuk National University Hospital during the years 1991-1995, were evaluated by dual parameter analysis in flow cytometric DNA measurement, Bryne's malignancy grading system, and the TNM classification. The aims of the present study were to discover that previously undetected aneuploid clones could be detected by dual parameter analysis and to determine the prognostic value of the above parameters. 1. Using dual parameter analysis of cytokeratin and DNA on disintegrated paraffin-embedded samples, aneuploid clones which were undetected by regular single parameter DNA analysis could be found among the cytokeratin-selected cells. DNA aneuploidy from paraffin-embedded samples were 15 cases compared with 10 cases using conventional DNA analysis. 2. The portion of aneuploid tumors showed slightly higher clinical stage and tumor size than the portion of diploid tumors, but the difference was not significant. The portion of DNA aneuploid tumors showed significantly higher mean mitosis and total malignancy scores than the portion of DNA diploid tumors. 3. The majority of the patients presented with clinical stage III and IV lesions showed significantly higher mean total malignancy score as compared to those with clinical stage I and II. 4. Histopathologic mean total malignancy score of the 31 cases was 12.7. Among the histologic parameters, mean mitosis score was correlated to the status of DNA ploidy and total malignancy score were correlated to the DNA ploidy and clinical staging.

  • PDF

Advancements in craniofacial prosthesis fabrication: A narrative review of holistic treatment

  • Jazayeri, Hossein E.;Kang, Steve;Masri, Radi M.;Kuhn, Lauren;Fahimipour, Farahnaz;Vanevenhoven, Rabecca;Thompson, Geoffrey;Gheisarifar, Maryam;Tahriri, Mohammadreza;Tayebi, Lobat
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.6
    • /
    • pp.430-439
    • /
    • 2018
  • The treatment of craniofacial anomalies has been challenging as a result of technological shortcomings that could not provide a consistent protocol to perfectly restore patient-specific anatomy. In the past, wax-up and impression-based maneuvers were implemented to achieve this clinical end. However, with the advent of computer-aided design and computer-aided manufacturing (CAD/CAM) technology, a rapid and cost-effective workflow in prosthetic rehabilitation has taken the place of the outdated procedures. Because the use of implants is so profound in different facets of restorative dentistry, their placement for craniofacial prosthesis retention has also been widely popular and advantageous in a variety of clinical settings. This review aims to effectively describe the well-rounded and interdisciplinary practice of craniofacial prosthesis fabrication and retention by outlining fabrication, osseointegrated implant placement for prosthesis retention, a myriad of clinical examples in the craniofacial complex, and a glimpse of the future of bioengineering principles to restore bioactivity and physiology to the previously defected tissue.

CASE REPORT ON FORCED ERUPTION FOR CLINICAL CROWN LENGTHENING IN MAXILLARY ANTERIORS (상악전치부에서 치아정출술을 이용한 치관연장의 증례보고)

  • Kim, Young-Jun;Ju, Jae-Ig;Ryue, Myung-Girl;Jin, Yu-Nam;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.111-120
    • /
    • 1995
  • This case report presents two maxillary anterior cases for clinical crown lengthening by forced eruption. In the first case, clinical crown of maxillary right lateral incisor was almost lost by fracture. Forced eruption using intracoronal splint and elastic thread accomplished vertical root movement successfully. Then, post & core was inserted and final restoration was harmonious with adjacent teeth. In the second case, the crown portion of maxillary right central incisor was almost mutilated by secondary caries. Forced eruption using removable Hawley appliance and elastic accomplished vertical root movement successfully. Then, post & core was inserted and final restoration was placed. In conclusion, clinical crown lengthening by vertical root movement can be accomplished by a simple appliance without any sacrifice of periodontal support in selected patients. A clinical crown so created can be restored to adequate function and arch integrity without compromising adjacent teeth. Therefore, forced eruption is preferred in the anterior region of the dentition where esthetics is of major concern.

  • PDF

Comparison of the effectiveness of essential oil mouthrinse and interdental brush in patients with fixed orthodontic appliances (Original Article 1 - 교정 장치를 접착한 환자에서 essential oil mouthrinse와 치간 칫솔의 효과 비교)

  • Hong, Sook-Chan;Kang, Sung-Taek;Shin, Joo-Hee;Lim, Yong-Kyu;Lee, Dong-Yul
    • The Journal of the Korean dental association
    • /
    • v.48 no.5
    • /
    • pp.371-378
    • /
    • 2010
  • The objective of this study was to compare the effectiveness of essential oil mouthrinse and interdental brush for oral hygiene in orthodontic patient. 90 patients, with fixed orthodontic appliances, were divided into 3 groups(Group 1: patients who had only used toothbrush, group 2: toothbrush + essential oil mouthrinse, group 3: toothbrush + interdental brush). Then, plaque index(PI) and gingival index(GI) were evaluated at before(T0), 3 weeks after(Tl) and 6 weeks after(T2) the experiment. The present study revealed the following conclusions: (1) There was statistically significant decrease in PI and GI of groups 2 and 3 comparing to those of group 1 during 6 weeks.(p<0.05) (2) There was no significant difference in the level of decrease in PI and GI between group 2 and group 3.(p<0.05) The present study thus implied that use of mechanical or chemical aid such as interdental brush and mouth rinse in addition to toothbrushing may help maintaining oral hygiene in patients undergoing fixed orthodontic treatment for prolonged duration.

TRAUMATIC ROOT FRACTURE IN YOUNG PERMANENT TOOTH : THREE CASE REPORTS (미성숙 영구치의 치근파절에 관한 증례보고)

  • Kim, Soo-Yeun;Choi, Byung-Jai;Choi, Hyung-Jun;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.3
    • /
    • pp.562-567
    • /
    • 1997
  • During the eruption of permanent teeth, Traumatic root fractures in young permanent incisors are rare. They occur most commonly in the maxillary central incisors of male patient and are frequently seen in the coronal third of the root. Permanent incisors are very important in terms of esthetics as well as of function, and so conservative treatment is advisable. It is important to maintain vitality of pulp to achieve better result. Location of the fracture line determines the Prognosis. No clinical change were seen in this three case. A case of central incisor with apparent healing of a root fracture without any tratment is presented in this paper. Long term clinical observation is required periodically.

  • PDF