• Title/Summary/Keyword: Clinical CT

Search Result 1,843, Processing Time 0.025 seconds

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

A Case of Pulmonary Embolism Patient Contraindicated in the Use of Anticoagulants Improved by Administering Hyulbuchuko-tang (항응고제 사용이 불가능했던 폐색전증 환자에 대한 혈부축어탕 치험 1례)

  • Ha, Won Jung;Lee, Yu Jin;Kim, Geun Young;Cho, Ki-Ho;Moon, Sang-Kwan;Jung, Woo-Sang;Kwon, Seungwon
    • The Journal of Internal Korean Medicine
    • /
    • v.42 no.3
    • /
    • pp.403-411
    • /
    • 2021
  • Background: This case report shows the effect of Hyulbuchuko-tang on a patient with a contraindication to anticoagulants who complained about dyspnea caused by pulmonary embolism (PE). Case report: A PE patient with dyspnea was treated with herbal medication, Hyulbuchuko-tang, for 28 days. Evaluations took place by assessing time for oxygen application time per day, follow-up chest CT, and D-dimer test results. Oxygen application time per day decreased, and oxygen therapy ended on the 14th day of Hyulbuchuko-tang treatment. Follow-up chest CT showed resolution of PE. The D-dimer level decreased on the 24th day and decreased more after 1 month later. Conclusion: This clinical case study suggests that Hyulbuchuko-tang might be effective in the resolution of PE and can be an option as a treatment for PE patients with contraindications to anticoagulants.

The Clinical Usefulness of Spiral CT Angiography in the Diagnosis of Pulmonary Thromboembolism (폐색전증 진단에서 나선식 전산화 단층촬영 혈관조영술의 임상적 유용성)

  • Kim, Woo-Gyu;Lim, Byung-Sung;Kim, Mi-Young;Hwang, Hweung-Kon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.669-680
    • /
    • 1999
  • Background: Pulmonary thromboembolism(PTE) is a life threatening disease that needs early diagnosis. Spiral CT angiography depict thromboemboli in the central pulmonary vessels with greater than 90% sensitivity and specificity, which approaches the results of pulmonary angiography in the Prospective Investigation of Pulmonary Embolism Diagnosis(PIOPED) study. This study was performed to evaluate the findings and the diagnostic value(clinical utility) of the spiral CT angiography with 2D image(multiplanar reformation) and 3D images(Shaded surface display, Minimal intensity projection) in the pulmonary thromboembolism. Methods: We retrospectively analysed spiral CT angiography and pulmonary angiography, lung scan and clinical recordings of 20 patients who had PTE diagnosed by spiral CT angiography(n=19 cases) or pulmonary angiography(n=l case) from September 1997 to August 1998. Among 20 patients who had underwent spiral CT angiography, 14 patients could be performed lung perfusion scan at the same time. We analyzed the vascular and parenchymal change in spiral CT angiogram. Results: Anatomical distribution of PTE was as follows: 1) left lung(n= 103)

  • PDF

Correlation of Body Mass Index, Body Fat Distribution, Aminotranferases and Computed Tomography in Obese Children with Fatty Liver (비만을 동반한 소아 지방간 환아에서 체질량 지수, 체지방 분포, 간 효소치 및 복부 CT 소견과의 상관관계에 대한 연구)

  • Park, So Eun;Yang, Hye Ran;Chang, Ju Young;Ko, Jae Sung;Seo, Jeong Kee;Lee, Whal;Kim, Woo Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.3
    • /
    • pp.276-283
    • /
    • 2005
  • Purpose : Visceral fat accumulation plays a major role in metabolic complications of obesity. It is known that nonalcoholic fatty liver in obese adults is associated with visceral fat accumulation. Body mass index(BMI) is used as the index of obesity in children. The aim of this study is to evaluate the correlation of BMI and visceral adipose tissue(VAT), and the correlation of BMI, body fat distribution, aminotransferases, and severity of fatty liver. Methods : Twenty three obese children with fatty liver diagnosed by non-contrast abdominal computed tomography(CT) were included in this study. Data on BMI, aminotransferase levels were collected from clinical records. Visceral adipose area was evaluated with CT. Results : BMI had a singnificant correlation with VAT(r=0.51719, P=0.0115). The severity of fatty liver had no significant correlations with BMI(r=-0.11938, P=0.5876), VAT(r=-0.31234, P=0.1468), aspartate aminotransferase(AST)(r=0.12729, P=0.5628) or alanine aminotransferase(ALT)(r=-0.00179, P=0.9935). Conclusion : BMI in obese children was correlated with VAT. But the severity of fatty liver cannot be assessed by BMI, VAT or aminotransferase levels.

A Study of the Metal Artifact Reduction using Dual Energy CT : Clinical Applications of Dual Energy and MAR Algorithm (Dual Energy CT를 이용한 금속물질 인공물 감소방법 : Dual Energy와 MAR알고리즘의 임상적 응용)

  • Park, Ki Seok;Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.273-279
    • /
    • 2021
  • Metal material inserted into the body have a large difference in density from human tissues or bones around the Metal during CT scans.. Therefore, the Metal material inserted into the body produces Artifact. Metal Artifact, which occurs around Metals, can degrade the quality of CT images, causing confusion when medical team diagnose lesions. Through this experiment, we confirm that the occurrence of Artifacts decrease by using Dual energy CT and MAR algorithm in Single source Dual energy CT. We also want to present basic data on clinical application methods by comparing and analyzing the characteristics of images obtained by each method. Using GE 750HD CT, artificial implants were scanned using general method and Dual energy. Then we apply the MAR algorithm to each image obtained. And all previously acquired images were compared and analyzed the characteristics of the examination, such as image quality evaluation and dose evaluation. Images with MAR algorithm and Dual Energy confirmed a decrease in Metal Artifact. Images with MAR algorithm have reduced Metal Artifact, but have the disadvantage of distorting the details of artificial joint implants. On the other hand images teseted with Dual Energy have the advantage of being able to implement details than those applied with MAR algorithms, it takes longer to reconstruct the image and the exposure dose was about four times higher than those applied with MAR algorithm. In order to locate Metals, such as the post-operative follow-up period, it is useful to apply MAR algorithm to obtain images. And it is more useful to examine with Dual Energy when micro lesion identification, such as cardiac examination, and surgical planning or when tests are performed in diagnostic way.

Primary Invasive Mucinous Adenocarcinoma of the Lung: Prognostic Value of CT Imaging Features Combined with Clinical Factors

  • Tingting Wang;Yang Yang;Xinyue Liu;Jiajun Deng;Junqi Wu;Likun Hou;Chunyan Wu;Yunlang She;Xiwen Sun;Dong Xie;Chang Chen
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.652-662
    • /
    • 2021
  • Objective: To investigate the association between CT imaging features and survival outcomes in patients with primary invasive mucinous adenocarcinoma (IMA). Materials and Methods: Preoperative CT image findings were consecutively evaluated in 317 patients with resected IMA from January 2011 to December 2015. The association between CT features and long-term survival were assessed by univariate analysis. The independent prognostic factors were identified by the multivariate Cox regression analyses. The survival comparison of IMA patients was investigated using the Kaplan-Meier method and propensity scores. Furthermore, the prognostic impact of CT features was assessed based on different imaging subtypes, and the results were adjusted using the Bonferroni method. Results: The median follow-up time was 52.8 months; the 5-year disease-free survival (DFS) and overall survival rates of resected IMAs were 68.5% and 77.6%, respectively. The univariate analyses of all IMA patients demonstrated that 15 CT imaging features, in addition to the clinicopathologic characteristics, significantly correlated with the recurrence or death of IMA patients. The multivariable analysis revealed that five of them, including imaging subtype (p = 0.002), spiculation (p < 0.001), tumor density (p = 0.008), air bronchogram (p < 0.001), emphysema (p < 0.001), and location (p = 0.029) were independent prognostic factors. The subgroup analysis demonstrated that pneumonic-type IMA had a significantly worse prognosis than solitary-type IMA. Moreover, for solitary-type IMAs, the most independent CT imaging biomarkers were air bronchogram and emphysema with an adjusted p value less than 0.05; for pneumonic-type IMA, the tumors with mixed consolidation and ground-glass opacity were associated with a longer DFS (adjusted p = 0.012). Conclusion: CT imaging features characteristic of IMA may provide prognostic information and individual risk assessment in addition to the recognized clinical predictors.

Predicting Recurrence-Free Survival After Upfront Surgery in Resectable Pancreatic Ductal Adenocarcinoma: A Preoperative Risk Score Based on CA 19-9, CT, and 18F-FDG PET/CT

  • Boryeong Jeong;Minyoung Oh;Seung Soo Lee;Nayoung Kim;Jae Seung Kim;Woohyung Lee;Song Cheol Kim;Hyoung Jung Kim;Jin Hee Kim;Jae Ho Byun
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.644-655
    • /
    • 2024
  • Objective: To develop and validate a preoperative risk score incorporating carbohydrate antigen (CA) 19-9, CT, and fluorine18-fluorodeoxyglucose (18F-FDG) PET/CT variables to predict recurrence-free survival (RFS) after upfront surgery in patients with resectable pancreatic ductal adenocarcinoma (PDAC). Materials and Methods: Patients with resectable PDAC who underwent upfront surgery between 2014 and 2017 (development set) or between 2018 and 2019 (test set) were retrospectively evaluated. In the development set, a risk-scoring system was developed using the multivariable Cox proportional hazards model, including variables associated with RFS. In the test set, the performance of the risk score was evaluated using the Harrell C-index and compared with that of the postoperative pathological tumor stage. Results: A total of 529 patients, including 335 (198 male; mean age ± standard deviation, 64 ± 9 years) and 194 (103 male; mean age, 66 ± 9 years) patients in the development and test sets, respectively, were evaluated. The risk score included five variables predicting RFS: tumor size (hazard ratio [HR], 1.29 per 1 cm increment; P < 0.001), maximal standardized uptake values of tumor ≥ 5.2 (HR, 1.29; P = 0.06), suspicious regional lymph nodes (HR, 1.43; P = 0.02), possible distant metastasis on 18F-FDG PET/CT (HR, 2.32; P = 0.03), and CA 19-9 (HR, 1.02 per 100 U/mL increment; P = 0.002). In the test set, the risk score showed good performance in predicting RFS (C-index, 0.61), similar to that of the pathologic tumor stage (C-index, 0.64; P = 0.17). Conclusion: The proposed risk score based on preoperative CA 19-9, CT, and 18F-FDG PET/CT variables may have clinical utility in selecting high-risk patients with resectable PDAC.

Assessment of the Effective Dose to the Human Body and Estimation of Lifetime Attributable Risk by CT Examination (CT 검사별 노출되는 유효선량과 생애 암 귀속 위험도 평가)

  • Cho, Yong In;Kim, Jung Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.169-178
    • /
    • 2020
  • The number of CT scans is increasing every year due to the improvement of the medical standards of the public, and thus the annual dose of medical radiation is also increasing. In this study, we evaluated the effective dose of the human body exposed to CT scans and estimated LAR. First, five region were selected from the CT diagnostic reference level guideline, and the effective dose of human body exposed to each examination was evaluated by clinical CT device. Second, the human organs and effective dose were calculated using the ALARA-CT program under the same conditions. Third, lifetime attributable risk (LAR) estimated by the effective dose exposed through the previous CT scan was estimated. As a result, the most effective dose was 21.18 mSv during the abdomen 4 phase scan, and the dose level was below DRL for all other tests except for the abdominal examination. As a result of evaluating effective dose using a dose calculation program under the same conditions, the results showed about 1.1 to 1.9 times higher results for each examination. In the case of organ dose, the closer the organ to the scan site, the higher the scattering ray. The lifetime attributable risk to CT radiation dose in adults was gradually decreased with age, and the results were somewhat different according to gender.

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

Sacral Meningeal Cyst Detected during Caudal Epidural Block (미추 경막외차단 도중 발견된 천추 수막낭 -증례 보고-)

  • Kang, Mi-Suk;Lim, Young-Jin;Lee, Sang-Chul
    • The Korean Journal of Pain
    • /
    • v.12 no.2
    • /
    • pp.258-262
    • /
    • 1999
  • Sacral meningeal cyst is usually asymtomatic, but may be responsible for sciatic pain syndromes and other clinical symptoms. Sacral meningeal cyst might be suspected when definite explanation for the clinical symptom, such as herniation of the intervertebral disc or spinal stenosis is not found. Plain films and CT may suggest the presence of sacral meningeal cyst, but MR is the current imaging study of choice. Evaluation of the correlation between the symptom and the cyst is as important as detection of it. We have experienced a case of sacral meningeal cyst detected during caudal epidural block. The patient complained of low back pain radiating to thigh. Plain films and lumbar spine CT showed no remarkable finding except disc bulging. During caudal epidural needle insertion, there was leakage of clear CSF, and intrasacral cystic shadow was visualized by dye injection. MR confirmed sacral meningeal cyst.

  • PDF