• 제목/요약/키워드: Cleaning power

검색결과 280건 처리시간 0.027초

평판디스플레이 세정 용 Quartz 메가소닉 시스템 (Quartz Megasonic System for Cleaning Flat Panel Display)

  • 김현세;이양래;임의수
    • 한국정밀공학회지
    • /
    • 제31권12호
    • /
    • pp.1107-1113
    • /
    • 2014
  • In this article, the megasonic cleaning system for cleaning micro/nano particles from flat panel display (FPD) surfaces was developed. A piezoelectric actuator and a waveguide were designed by finite element method (FEM) analysis. The calculated peak frequency value of the quartz waveguide was 1002 kHz, which agreed well with the measured value of 1003 kHz. The average acoustic pressure of the megasonic cleaning system was 43.1 kPa, which is three times greater than that of the conventional type of 13.9 kPa. Particle removal efficiency (PRE) tests were performed, and the cleaning efficiency of the developed system was proven to be 99%. The power consumption of the developed system was 64% lower than that of the commercial system. These results show that the developed megasonic cleaning system can be an effective solution in particle removing from FPD substrate with higher energy efficiency and lower chemical and ultra pure water (UPW) consumption.

Micro-Pulse 하전식 집진기용 초고압 전원장치 개발 (Development of A High Voltage Generator for EP Adopting the Micro-Pulse Concept)

  • 김원호;강유리;김종수;임근희;김종화;조창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2130-2132
    • /
    • 1998
  • With the increasing demands for clean environment, development of air cleaning systems has been received increasing attention. EP is usually used for air cleaning in the coal power plant. One of the key technology in the EP is high voltage pulse power supply, which affects the performance of the overall system. In this study, high voltage micro pulse power supply for the EP is developed for a 500MW coal power plant. The power supply has a dc source and a pulse one. The ratings of the dc and pulse source are 60kV, 800mA and 70kV, 400mA respectively.

  • PDF

2,2,2-trifluoroethanol (TFEA)를 기초로한 세정제의 물성 및 세정성 영향 연구 (Physical Properties and Cleaning Ability of New Cleaning Agents Based on 2,2,2-trifluoroethanol (TFEA))

  • 차안정;박지나;김홍곤;배재흠
    • 공업화학
    • /
    • 제16권4호
    • /
    • pp.533-541
    • /
    • 2005
  • 2,2,2-trifluoroethanol (TFEA)과 hydrofluoroether (HFE)를 혼합하여 비수계 세정제를 제조하고 이들의 혼합비에 따른 물성과 세정성의 영향을 연구하였다. 또한 TFEA를 기초로 하고 비이온 계면활성제, 가용화제와 빌더를 첨가한 수계 세정제를 제조하고 이들의 세정능력을 비교하여 CFC-113, 1,1,1-TCE에 대한 대체 가능성을 평가하였다. 오염 물질로 수용성이거나 친수성, 지용성이거나 친유성인 각기 다른 플럭스, 절삭유, 그리스, 불소계 오일 등을 선정하고, 세정시간에 따른 오염물질의 중량변화를 비교하여 각 세정제의 세정능력을 비교함으로써 대체세정제로서의 TFEA를 기초로 한 세정제의 적용 가능성을 평가하였다. 그 결과 TFEA와 HFE를 주성분으로 하여 제조한 비수계 세정제는 플럭스와 불소계 오염물에 우수한 세정성을 보여주었지만 그리스 세정에서는 세정성이 떨어졌다. 이에 비하여 TFEA를 기초로 하고 비이온 계면활성제, 가용화제, 빌더 등을 첨가하여 제조한 수계세정제는 일정한 배합 조건에서 플럭스와 그리스 제거에 매우 효과적이었다. 따라서 TFEA를 기초로 한 수계 및 비수계 세정제는 특정 오염물질에 대하여 좋은 세정력을 보여 주어 CFC-113, 1,1,1,-TCE 등의 대체세정제로의 가능성을 보여주었다.

열동력 시스템 내부 열교환 표면의 클리닝에 관한 연구 (A study of cleaning of heat transfer surface in thermal power system)

  • 한규일
    • 수산해양기술연구
    • /
    • 제51권4호
    • /
    • pp.576-582
    • /
    • 2015
  • The efficiencies of thermal power system using fossil fuel depend on heat exchangers which extract energy from the exhaust gas before it is expelled to the atmosphere. To increase heat transfer efficiency it is very important to maintain the surface of heat exchanger as clean condition. The accepted skill of cleaning of fouled surface of heat exchanger is soot blowing. A high pressure jet of air is forced through the flat surface of plate to remove the deposit of fouling. There is, however, little knowledge of the fundamental principles of how the jet behave on the surface and how the jet actually removes the deposit. Therefore, the study focuses on the measuring of cleaning area and cleaning dwell time after accumulating the simulated deposit on the flat surface. The deposit test rig was built for the study and simulated deposit material is used after measuring the physical property of the each material by shearing stress test. Much data was obtained for the analysis by the parameters change such as the different jet speed, different inner pressure and variable distance of the jet from the test rig surface. The experimental data was compared with the theoretical equation and most of the data matches well except some extreme cases.

건물 청소노동자의 노동 경험 (Working Experiences of Cleaning Workers)

  • 김소연;김영미
    • 한국직업건강간호학회지
    • /
    • 제24권3호
    • /
    • pp.183-193
    • /
    • 2015
  • Purpose: The purpose of this study was to describe cleaning workers' working experiences in Korea. Methods: The data were collected in two focus-group interviews with 9 cleaning workers. The phenomenological analytic method suggested by Colaizzi was used to analyze the data. Results: Five theme clusters and thirteen themes emerged from the analysis. The first theme clusters, 'Dead-end choice' included Limits of elderly women workers, Financial difficulties, Lowered self-esteem. The second theme clusters, 'Facing with discriminatory working environments' included Fear and unfair working conditions. The third theme clusters, 'Potential health problems' included Physical overload, Repeated exposure to hazardous substances and Emotional labor. The fourth theme clusters, 'Excluded from protection of the law' included Gloomy reality and Sexual harassment. The fifth theme clusters, 'Desire to get out of social isolation' included Efforts to maintain the status, Desire to live confidently and Desire to change social recognition. Conclusion: The findings of the study provide understanding on cleaning workers' working experiences to explain by their vision and language and should ensure proper working conditions and environment to live a better life.

A Study on the Chemical Cleaning Process and Its Qualification Test by Eddy Current Testing

  • Shin, Ki Seok;Cheon, Keun Young;Nam, Min Woo;Min, Kyong Mahn
    • 비파괴검사학회지
    • /
    • 제33권6호
    • /
    • pp.511-518
    • /
    • 2013
  • Steam Generator (SG) tube, as a barrier isolating the primary coolant system from the secondary side of nuclear power plants (NPP), must maintain the structural integrity for the public safety and their efficient power generation. So, SG tubes are subject to the periodic examination and the repairs if needed so that any defective tubes are not in service. Recently, corrosion related degradations were detected in the tubes of the domestic OPR-1000 NPP, as a form of axially oriented outer diameter stress corrosion cracking (ODSCC). According to the studies on the factors causing the heat fouling as well as developing corrosion cracking, densely scaled deposits on the secondary side of the SG tubes are mainly known to be problematic causing the adverse impacts against the soundness of the SG tubes [1]. Therefore, the processes of various cleaning methods efficiently to dissolve and remove the deposits have been applied as well as it is imperative to maintain the structural integrity of the tubes after exposing to the cleaning agent. So qualification test (QT) should be carried out to assess the perfection of the chemical cleaning and QT is to apply the processes and to do ECT. In this paper, the chemical cleaning processes to dissolve and remove the scaled deposits are introduced and results of ECT on the artificial crack specimens to determine the effectiveness of those processes are represented.

고온화학세정환경에서 20 % EDTA 용액이 결함 전열관 (Alloy600)에 미치는 영향 (Effect of 20 % EDTA Aqueous Solution on Defective Tubes (Alloy600) in High Temperature Chemical Cleaning Environments)

  • 권혁철
    • Corrosion Science and Technology
    • /
    • 제15권2호
    • /
    • pp.84-91
    • /
    • 2016
  • The transport and deposition of corrosion products in pressurized water nuclear reactor (PWR) steam generators have led to corrosion (SCC, denting etc.) problems. Lancing, mechanical cleaning and chemical cleaning have been used to reduce these problems. The methods of lancing and mechanical cleaning have limitations in removing corrosion products due to the structure of steam generator tubes. But high temperature chemical cleaning (HTCC) with EDTA is the most effective method to remove corrosion products regardless of the structure. However, EDTA in chemical cleaning aqueous solution and chemical cleaning environments affects the integrity of materials used in steam generators. The nuclear power plants have to perform the pre-test (also called as qualification test (QT)) that confirms the effect on the integrity of materials after HTCC. This is one of the series studies that assess the effect, and this study determines the effects of 20 % EDTA aqueous solution on defective tubes in high temperature chemical cleaning environments. The depth and magnitude of defects in steam generator (SG) tubes were measured by eddy current test (ECT) signals. Surface analysis and magnitude of defects were performed by using SEM/EDS. Corrosion rate was assessed by weight loss of specimens. The ECT signals (potential and depth %) of defective tubes increased marginally. But the lengths of defects, oxides on the surface and weights of specimens did not change. The average corrosion rate of standard corrosion specimens was negligible. But the surfaces on specimens showed traces of etching. The depth of etching showed a range on the nanometer. After comprehensive evaluation of all the results, it is concluded that 20 % EDTA aqueous solution in high temperature chemical cleaning environments does not have a negative effect on defective tubes.