• Title/Summary/Keyword: Cleaning Method

Search Result 713, Processing Time 0.028 seconds

The Effect of Professional Tooth Cleaning and Plaque Control Instruction according to the Smoking Behavior (흡연이 전문가치면세정술 및 세균막관리교육 효과에 미치는 영향)

  • Han, Gyeong-Soon;Bae, Kwang-Hak;Kwon, Soon-Bok;Han, Su-Jin;Choi, Jun-Seon
    • Korean Journal of Health Education and Promotion
    • /
    • v.26 no.2
    • /
    • pp.25-33
    • /
    • 2009
  • Objectives: Smoking is related to periodontal disease and periodontal therapy. So the aim of this study was to investigate the effects of professional tooth cleaning and plaque control instruction (PT & PCI) for smoking behavior. Methods: A total of 151 adults were investigated using the O'Leary Plaque Index (PI), $L\ddot{o}e$ & Silness gingival index (GI) and the number of sextants possessing periodontal pocket (SPP). And adults were given a through dental scaling and Watanabe method for dental plaque control. Follow up examination were conducted after 3 months and compared the pre and post- status. The collected data were analyzed with t-test, paired t-test and one-way analysis of variance. Results: Regardless of smoking behavior, improving effects were identified after PT & PCI on PI, GI and SPP in the whole population. However, the effects of GI improvement were significant in the smoking group alone; those of PI improvement were most significant in the non-smoking group; and those of SPP improvement were more significant in non-smoking and pre-smoking groups than in the smoking group. The shorter period of smoking and the smaller amount of smoking, the greater effects of PT & PCI by smoking-related characteristics. Conclusion: Smoking cessation instruction should necessarily be included in oral health education in that smoking is an important factor to consider in prevention of periodontal diseases and periodontal therapies.

Four-legged robot for glass building cleaning (유리빌딩 청소를 위한 4족 보행로봇)

  • Kim, Cheong-Sol;Kim, Dong-sung;Choi, Cheong-hwan;Park, Ji-min;Jin, Tae-seok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.452-455
    • /
    • 2017
  • As the number of high - rise buildings has increased recently, this research society has become interested in the method of cleaning the external wall required. When cleaning these areas, an accident occurs every year when a person uses dangerous manual labor using a gondola. The main goal of this work is to enable people to manipulate the robot with simple operation without dangerous manual operation when working in a vertical structure. As the altitude increases, the concept of the mechanism attaching to the vertical structure while enduring the external resistance in the increase of the wind strength is applied, and the additional attachment device is attached to the end of the leg based on the existing four- According to the control, the development result of the robot having the function of detachable to the glass is presented.

  • PDF

Estimation of the Effect of Clean Road System on the $PM_{10}$ Concentration at a Heavy Traffic Roadside - A Case study for Daegu City - (클린로드 시스템 가동이 도로변 $PM_{10}$ 농도에 미치는 영향 분석- 대구지역의 사례연구 -)

  • Jo, Byung-Yoon;Baek, Sung-Ok
    • Particle and aerosol research
    • /
    • v.8 no.3
    • /
    • pp.111-120
    • /
    • 2012
  • In Daegu, a road cleaning system was constructed in the central part of the city and has been operated from April, 2011. We evaluated the effect of the system on the concentration of $PM_{10}$ at a roadside monitoring site. The ambient $PM_{10}$ concentration data were logged every 1 min for a period of 20 weeks from May to October, 2011, by means of light scattering method, and then every 5 min data were used in the statistical analysis. The measured data were verified by comparing them with beta-ray data obtained at the same site. Correlation coefficient between the two groups was highly significant (r=0.79), though the absolute levels of light scattering data appeared to be approximately 2.8 times higher than the beta-ray data. Diurnal, daily, weekly, and monthly variations of $PM_{10}$ data did not show any evidence of decreasing effect owing to the clean road system. A comparison of roadside $PM_{10}$ data with non-roadside data also revealed very similar pattern, implying the variation of the $PM_{10}$ concentrations is mainly affected by the traffic conditions near the monitoring site. However, if the operating conditions of the clean road system can be improved, i.e. increasing the frequency and duration of water cleaning, the road cleaning effect may improve the air quality indirectly by means of removing the resuspended particles from the road.

Exposure Assessment of Crystalline Silica in Diatomite Powder Handling Workplace with Acute Silicosis (급성 규폐증이 발생한 규조토 분말 취급 작업장의 결정형 실리카 노출평가: 역학조사 사례)

  • Kim, Boowook;Kim, Daeho;Kim, Hyoung-Ryoul;Choi, Byung-Soon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.271-277
    • /
    • 2019
  • Objectives: A 46-year-old woman who had worked on cleaning stainless steel containers with Initially unknown powders died from acute silicosis. To determine whether the acute silicosis was related to his work environment, we conducted exposure assessment the level of exposure to respirable crystalline silica(RCS) during cleaning stainless steel containers with unknown powders. Methods: The exposure assessment of RCS were undertaken according to the National Institute for Occupational Safety and Health(NIOSH) method 7500. The components of the unknown powder were analyzed using X-ray Diffraction. Results: The unknown powder was found to be natural diatomaceous earth, which contained 12% and 9% quartz and cristobalite, respectively, crystalline silica. In the case of cleaning stainless steel containers with diatomaceous earth powder, the primary measurement resulted in 1.3 times higher occupational exposure limit of MOEL(in sum of quartz and cristobalite concentration) and 3.9 times higher in secondary measurement. The workbench was equipped with a local exhaust system, but because there was no hood at the end of the duct, the wind speed at the opening of the duct was 12 m/sec, whereas the controlled wind speed at the working position was only 0.3 m/sec below the legal standard. Conclusions: There is an urgent need to install the hood, conduct safety and health education for employers and workers, and periodically monitoring and manage the working environment.

A Study on the Effectiveness of Remanufacturing Technology for the Diesel Oxidation Catalyst(DOC) Deactivated by Diesel Exhaust Gas (경유차 매연저감장치에 의해 비활성화된 DOC촉매의 재제조 효과에 관한 연구)

  • Park, Hea-Kyung
    • Clean Technology
    • /
    • v.16 no.4
    • /
    • pp.265-271
    • /
    • 2010
  • The deactivated diesel oxidation catalyst(DOC) was remanufactured by ultrasonic wave treatment with various solutions, followed by active component re-impregnation. The catalytic performance and surface properties of remanufactured DOC were studied at various remanufacturing conditions. The proper ultrasonic-wave cleaning time at various solutions and optimal re-impregnation amounts of active component for the best catalytic performance were investigated. The catalytic performance tests on the conversions of CO and THC(total hydrocarbon) were also carried out at various temperatures by catalytic reaction test unit using bypass gas from the diesel engine dynamo system. It was found that the catalytic performance of DOC remanufactured with the high-temperature air washing, ultrasonic wave cleaning at acidic/basic solutions and active component re-impregnation method was recovered to 90% level of its activity compared to that of the fresh DOC, which was caused by removing the deactivating materials from the surface of the DOC through the analyses of catalyst performance test and their characterization by Optical microscope, EDX, ICP, TGA, and porosimeter.

Automatic Feeding Bottle Washing Machine Usability Evaluation : Infant Product (자동 젖병 세척기 사용성평가 : 영유아 제품)

  • Park, Hye Jin;Kim, Jong Geun;Lee, Seok Jae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.3
    • /
    • pp.507-514
    • /
    • 2022
  • This study is to compare and analyze the evaluation of cleaning cleanliness and usability according to the muscle activity and cleaning method in the wrist rotation motion when using a bottle washer for women with childbirth experience. To this end, when using an automatic bottle washer and a manual bottle washer, the muscle activity and cleaning cleanliness of the forearm muscles were quantitatively evaluated using equipment, and the effects of variables were analyzed and the following conclusions were obtained. First, it was found that the muscle activity was lower than that of the automatic baby bottle cleaner when using a manual bottle cleaner. Second, the cleanliness was judged to be the best in automatic washing (forward + reverse direction), followed by automatic washing (forward direction) and manual washing. Third, the usability evaluation of the use of the baby bottle washing machine showed higher satisfaction than that of the automatic baby bottle washing machine. Through these conclusions, this study can be used as basic data for product advancement in the future by proving the effectiveness of using an automatic bottle washer.

Effects of Chloride and Sulfate Ions on Corrosion Behaviors of Structural Materials Based on Design of Experiment (실험계획에 기반한 수돗물 성분(Chloride and Sulfate Ions)의 구조재료 부식 영향성 고찰)

  • Dong-In Lim;Heng-Su Noh;Hyeok-Jun Kwon;Sung-Ryul Park;Man-Sik Jo;Doo-Youl Lee
    • Corrosion Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.201-213
    • /
    • 2023
  • Corrosion management of an aircraft and its engine relies on rinsing and cleaning using tap water. Few studies have reported effects of tap water species on corrosion behaviors of structural materials. In this study, a series of experiments were conducted based on the design of experiment. Solutions with different levels of chloride and sulfate ions were prepared using a full factorial design. Two structural materials (aluminum alloy and steel) were used for an alternate immersion test. Weight loss was then measured. In addition, a silver specimen was utilized as a sensor for chloride deposition measurement. The silver specimen was examined using the electrochemical reduction method, XPS, and SEM-EDS. Surface analysis revealed that levels of chloride and sulfate ions were sufficient for the formation of silver chloride and silver surface. Statistical analysis of weight loss and chloride deposition rate showed significant differences in measured values. Concentration of chloride ions greatly affected corrosion behaviors of structural materials. Sulfate ion hindered the adsorption reaction. These results emphasize the importance of controlling ion concentration of tap water used for cleaning and rinsing an aircraft.

Efficient Coverage Path Planning and Path Following in Dynamic Environments (효율적 커버리지 경로 계획 및 동적 환경에서의 경로 주행)

  • Kim, Si-Jong;Kang, Jung-Won;Chung, Myung-Jin
    • The Journal of Korea Robotics Society
    • /
    • v.2 no.4
    • /
    • pp.304-309
    • /
    • 2007
  • This paper describes an efficient path generation method for area coverage. Its applications include robots for de-mining, cleaning, painting, and so on. Our method is basically based on a divide and conquer strategy. We developed a novel cell decomposition algorithm that divides a given area into several cells. Each cell is covered by a robot motion that requires minimum time to cover the cell. Using this method, completeness and time efficiency of coverage are easily achieved. For the completeness of coverage in dynamic environments, we also propose a path following method that makes the robot cover missed areas as a result of the presence of unknown obstacles. The effectiveness of the method is verified using computer simulations.

  • PDF

Chemical Cleaning of Iron Stains on Ceramics (화학세척제를 이용한 도자기의 철산화물 제거 특성 연구)

  • Park, Dae-Woo;Jang, Sung-Yoon;Nam, Byeong-Jik;Ham, Chul-Hee;Lim, Seong-Tae
    • Journal of Conservation Science
    • /
    • v.27 no.4
    • /
    • pp.345-356
    • /
    • 2011
  • To remove metal stains of the ceramics, chemical cleaning is essential case by case. This study investigated the removal characteristics of iron stains by oxalic acid and citric acid including their application methods of soaking and poultice. The soaking method in cleaning agents showed removal process by color difference and released iron contents from iron stains on ceramics. Iron stains were removed successfully from ceramics, which soaked in oxalic acid for 60 hours. However, it is recommendable to soak in 0.25M oxalic acid for one to three hours because most iron stains were disappeared in 3 hours soaking. Citric acid is less effective than oxalic acid in removing iron stains because of heavy molecular weight and low acidity. Poultices (bentonite, sepiolite, activated carbon fiber and celite) with oxalic acid were applied on contaminated ceramics. After ten hours, iron stains on ceramics were removed successfully by poultice. Among them, bentonite and sepiolite have better application. Therefore, sepiolite with 0.25M oxalic acid was applied on the iron stains of whiteware and celadon from Ma Island, and then stains were removed. However, it is judged that the application methods can be varied according to the form and depth of contaminant. In addition, the residues of poultice on the ceramics will be considered for preventing contamination.

Characteristics of Nano-Size Au Fine Particles Doped TiO2 Thin Films by Sol-Gel Method (졸-겔법에 의한 나노크기 Au 미립자 분산 TiO2 박막의 특성)

  • Park, Min-Jung;Koo, Se-Na;Lee, Kyoung-Seok;Mun, Chong-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.2 s.285
    • /
    • pp.114-120
    • /
    • 2006
  • Nano-size Au particle doped $TiO_2$ films were prepared with $Ti(OC_3H_7^i)_4$, polyvinylpyrrolidone(PVP), $HAuCl_4$ and $C_3H_7OH$ etc. by sol-gel method. $TiO_2$ gel films were obtained by the dip-coating method on the $SiO_2$ glass substrates, and then heat-treated at $700^{\circ}C$ for 10 min. The thickness of $TiO_2$ films were $0.7\~1.8\;{\mu}m$. It was found that the thickness of films prepared from PVP containing solution was about $2\~8$ times higher values than that of thin films without PVP. The size of Au particles doped in the films were about $350\~750\;nm$. Nano-size Au particle dispersed $TiO_2$ films showed high absorption peak at visible region 450nm, which made them good candidates for non-linear optical materials and photo-catalytic materials. The contact angle of $TiO_2$ film for water was $12.5^{\circ}$, and therefore it is clear that $TiO_2$ films have very high hydrophilic properties and the self-cleaning effects.