• Title/Summary/Keyword: Cleaner Technology

Search Result 205, Processing Time 0.021 seconds

Antibiotic Resistance of Food-Borne Pathogens Isolated from an Indoor Environment of a Lunchroom in a Child Care Center (보육시설 급식실 실내 환경에서 분리된 식중독 미생물의 항생제 내성 특성)

  • Kim, Jung-Beom;Kim, Jong-Chan
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.5
    • /
    • pp.415-423
    • /
    • 2012
  • Objectives: This study was performed in order to evaluate antibiotic resistance and analyze the multiple antibiotic resistance of food-borne pathogens isolated from indoor air and an air cleaner at a lunch room in a child care center. Methods: An antibiotic test of food-borne pathogens, including four Staphylococcus aureus and 23 Bacillus cereus was conducted through the disk diffusion method from Clinical and Laboratory Standard Institute. Results: All Staph. aureus was resistant to Ampicillin and Penicillin, while B. cereus was also resistant to Ampicillin, Cefepime and Penicillin. All isolates showed Vancomycin susceptibility but three out of four Staph. aureus and all B. cereus were resistant to Oxacillin. Staph. aureus and B. cereus presented two or more multiple antibiotic resistances. Conclusions: The results indicated that food-borne pathogens isolated from indoor air and an air cleaner at a lunch room in a child care center showed multiple antibiotic resistances. The repeated control of indoor environment quality is required and continuous surveillance of antibiotic resistant strains is demanded.

Characteristics of Strong Alkaline Electrolyzed Water Produced in All-in-one Electrolytic Cell (일체형 전해조에서 생산된 강알카리성 전해수의 특성)

  • Lee, Ho Il;Rhee, Young Woo;Kang, Kyung Seok
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.446-450
    • /
    • 2012
  • Strong alkaline electrolyzed water which is produced in cathode by electrolyzing the solution where electrolytes (NaCl, $K_2CO_3$ etc.) are added in diaphragm electrolytic cell, is eco-friendly and has cleaning effects. So, it is viewed as a substitution of chemical cleaner. In addition, strong alkaline electrolyzed water is being used by some Japanese automobile and precision parts manufacturing industries. When strong alkaline electrolyzed water is produced by using diaphragm electrolytic cell, it is necessarily produced at the anode side. Since strong acidic electrolyzed water produced is discarded when its utilization cannot be found, production efficiency of electrolyzed water is consequently decreased. Also, there is a weakness electrolytic efficiency is decreasing due to the pollution of diaphragm. In order to overcome this, non-diaphragm all-in-one electrolytic cell integrated with electrode reaction chamber and dilution chamber was applied. Strong alkaline electrolyzed water was produced for different composition of electrolytes, and their properties and characteristics were identified. In comparing the properties between strong alkaline electrolyzed water produced in diaphragm electrolytic cell and that produced in all-in-one electrolytic cell, the differences in ORP and chlorine concentration were found. In emulsification test to confirm surface-active capability, similar results were obtained and strong alkaline electrolyzed water produced in non-diaphragm all-in-one electrolytic cell was identified to be useable as a cleaner like strong alkaline electrolyzed water produced in diaphragm electrolytic cell. Strong alkaline electrolyzed water produced in non-diaphragm all-in-one electrolytic cell is thought to have sterilizing power because it has active chlorine which is different from strong alkaline electrolyzed water produced in diaphragm electrolytic cell.

Enviromentally Friendly Aqueous/Semi-aqueous Cleaning Technology (환경친화적 수계/준수계 세정 기술)

  • Bae, Jae-Heum;Kim, Jung-Sik
    • Clean Technology
    • /
    • v.3 no.2
    • /
    • pp.36-46
    • /
    • 1997
  • CFC and organic chlorine solvents has been used in the fine machinery and electronics industries for a long time since they have various excellent properties as cleaning agents. However, it is inevitable that alternative cleaning agents should be used since CFC and organic chlorine solvents were identified as ozone-depleting chemicals. There are various alternative cleaning agents. Among them, aqueous/semi-aqueous cleaning agents are environmentally friendly and promising in the long term. And their use and developement are on the increase in advanced countries, but few in our countries. In this paper, the charactistics and major components aqueous/semi-aqueous cleaning agents are analyzed and compared. And various cleaning equipments for aqueous/semi-aqueous cleaning agents such as immersion cleaner, ultronsonic cleaners, power spray cleaner, and vibration or rotational cleaners are compared and evaluated. Finally, important consideration points for selction of a cleaning system are analyzed and suggested in this paper.

  • PDF

Linear measurement evaluation according to UV-type ultrasonic cleaning of artificial teeth for temporary dentures manufactured using a light-curing type printer produced by a DLP printer (광중합형 프린터로 제작한 임시 의치용 인공치아의 UV형 초음파 세척에 따른 선형측정 평가)

  • Dong-Yeon Kim;Gwang-Young Lee
    • Journal of Technologic Dentistry
    • /
    • v.46 no.1
    • /
    • pp.8-14
    • /
    • 2024
  • Purpose: This study compares the deformation of traditional resin dentures to resin dentures printed with digital light processing (DLP). Methods: Eleven edentulous research models were developed. Ten of them were made with traditional resin dentures. The remaining one was prepared for scanning and 3D (three-dimensional) printing. Ten traditional resin dentures were made, with the remaining artificial teeth created using 3D software and a DLP printer. Traditional resin dentures, 3D printed resin denture artificial teeth, and a denture base with artificial teeth were all cleaned simultaneously in an ultrasonic cleaner for 3 minutes. Three groups were assigned four artificial tooth measurement points, which were then measured with digital calipers. The measured data was analyzed using descriptive statistics. The significance test was conducted using a nonparametric test Kruskal-Wallis test due to the small number of specimens (α=0.05). Results: The traditional resin dentures had the lowest strain rate at -0.04%, while the group that manufactured only artificial teeth had the highest strain rate at -0.09%. However, no statistically significant difference was observed between the 3 groups (p>0.05). Conclusion: During ultraviolet-type ultrasonic cleaning, traditional resin dentures (TD group) and denture base with artificial teeth made of DLP (DD group) demonstrated stable durability, whereas the artificial teeth made of DLP (AD group) with only artificial teeth did not show a good deformation rate.

A Study on the Measurement of the Pollution Level of Bacteria and Disinfection of Table and IP Cassette (촬영 테이블과 IP Cassette의 세균 오염도 측정 및 소독에 관한 연구)

  • Bae, Seok-Hwan;Lee, Moo-Sik;Lim, Chang-Seon;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.229-237
    • /
    • 2008
  • Purpose : For the number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories, after identifying the bacteria before and after using alcohol and tissue including disinfectant and statistically testing, this research was intended to provide the basic data for the prevention and the right disinfection guideline for infection management of hospitals in diagnostic radiology. Subject and Method : The subject of this research was the general room of diagnostic radiology of a university hospital in Daejeon City. The research was conducted from Apr 5 to Apr 12, 2007. The number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories were tested before and after using alcohol and tissue for disinfection including disinfectant. In order to collect specimens exactly, they were collected with the nurse who specialized in infection management of the hospital, and statistical processing was done with SPSS V13.0. To compare the results before and after using alcohol and tissue, T-test was implemented, and post-hoc test was conducted. Results : Bacteria were detected in 19 cases of 24 subjects(79.2%), however, they were not detected in 5 cases(20.8%). 7kinds of bacteria were detected as isolated bacteria, of which Methicillin Resistant coagulase-negative Staphylococci(MRCNS) were detected in 15 cases(62.5%), which was most, Methicillin Resistant Staphylococcus Aureus(MRSA) in 6 cases(16.7%), Enterococcus Faecium(EFM) in 5 cases(20.8%), Acinetobacter baumannii(ABA) in 2 cases(8.3%), and Bacillus sp, Coagulase-negative Staphylococci(CNS), and Enterococcus sp(ENT) in 1 case, respectively(4.2%). In all bacteria except ABA, Gram positive bacillia were detected in 30 cases(97%), and Gram negative bacilli were detected only in 1 case(3%). As for the kinds of bacteria and the number of groups before and after using 70% Alcohol by Groups, when the bacteria were identified after disinfecting IP Cassette and Table with 70% Alcohol, all the bacteria became extinct in both IP Cassette and Table Group(100%). As for the kinds and number of bacteria before and after using Tissue Cleaner by Groups, the bacteria in Tissue Cleaner Group became completely extinct only in 10 Groups(71.2%), and in 4 Groups, there was much decrease in bacteria, however, they were still detected. The extinction rate of all the bacteria was 91.5%. That is, though the other bacteria became extinct(100%), that of MRCNS bacteria was lowest(83.6%), followed by MRSA(95%). Conclusion : As a result of comparing the mean of the bacteria which were detected before and after using 70% Alcohol and Tissue Cleaner, there was statistically significant in the significant level of 5% in both of them.

  • PDF

Zirconium(IV) Chloride - Catalysed Reaction of Indoles: An Expeditious Synthesis of Bis(indolyl)methanes

  • Nagawade, Rahul R.;Shinde, Devanand B.
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.12
    • /
    • pp.1962-1964
    • /
    • 2005
  • Zirconium(IV) chloride is found to be an efficient catalyst for the electrophilic addition reaction of indole with aldehydes/ketones to afford the corresponding bis(indolyl methanes in good yields. The remarkable features of this new procedure are high conversions, shorter reaction times, cleaner reaction profiles and simple experimental and work-up procedures.

Smart Grid and Its Implications for Electricity Market Design

  • Kim, Seon-Gu;Hur, Seong-Il;Chae, Yeoung-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Recently, smart grid has been considered a very important new energy delivery technology, and one that can help ensure a cleaner environment by making use of information and communication technology (ICT) in countries around the world. The many technological benefits smart grid offers is expected to bring about a huge change in the electric energy supply chain. In particular, smart grid with advanced ICT is likely to allow market agents to participate in the decision-making process in the restructured electricity industry, easily facilitating Homeostatic Utility Control. In this paper, we examine smart grid as a market externality, and then illustrate issues from the commercial market perspective as it relates to electricity market design. Finally, our paper identifies some of the impacts of smart grid on electricity market design, which may possibly be incorporated into the evolution of the electricity market, thus ensuring market efficiency.