• Title/Summary/Keyword: Clamp switching method

Search Result 23, Processing Time 0.023 seconds

A New Switching Method for Reducing switch loss of Single-phase three-level NPC inverter (스위치 손실 감소를 위한 단상 3레벨 NPC 인버터의 새로운 스위칭 방법)

  • Lee, Seung-Joo;Lee, June-Seok;Lee, Kyo-Beum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.268-275
    • /
    • 2015
  • This paper proposes a method of switching to improve power loss for the single-phase three-level NPC inverter. The conventional switching methods, which are called as the bipolar and unipolar switching methods, are used for single phase inverters using three-level topology. However, these switching method have disadvantage in the power loss. Because all of the switch are operated. To reduce the power loss of the three-level NPC inverter, clamp switching method is introduced in this paper. This way, one of the lag is fixed that switching loss is reduced. This paper analyzes and compares power losses of unipolar method and clamp method. The validity of the power loss analysis is verified through the simulation and experimental results.

A New Controllable Active Clamp Algorithm for Switching Loss Reduction in a Module Integrated Converter System

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.4
    • /
    • pp.465-471
    • /
    • 2014
  • This paper proposes a new switching algorithm for an active clamp snubber to improve the efficiency of a module integrated converter system. This system uses an active clamp method for the snubber circuit for the efficiency and reliability of the system. However, the active clamp snubber circuit has the disadvantage that system efficiency is decreased by switch operating time because of heat loss in resonance between the snubber capacitor and leakage inductance. To address this, this paper proposes a new switching algorithm. The proposed algorithm is a technique to reduce power consumption by reducing the resonance of the snubber switch operation time. Also, the snubber switch is operated at zero voltage switching by turning on the snubber switch before main switch turn-off. Simulation and experimental results are presented to show the validity of the proposed new active clamp control algorithm.

A Novel Active Clamp Switching Method To Improve of Efficiency For Photovoltaic MIC (태양광 MIC 시스템의 효율향상을 위한 새로운 Active Clamp 스위칭 기법)

  • Park, Byung-Chul;Park, Ji-Ho;Song, Sung-Geun;Park, Sung-Jun;Shin, Joong-Rin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.477-484
    • /
    • 2013
  • This paper proposes a novel switching method of active clamp snubber for efficiency improvement of PV module integrated converter(MIC) system. Recently, MIC solar system is researched about the efficiency and safety. PV MIC system is used active clamp method of snubber circuit for the price and reliability of the system. But active clamp snubber circuit has the disadvantage that system efficiency is decreased for switch operating time because of heat loss of resonant between snubber capacitor and leakage inductance. To solve this problem, this paper proposes a novel switching method of the active clamp. The proposed method is a technique to reduce power consumption by reducing the resonance of the snubber switch operation time and through simulations and experiments proved the validity.

A Study on the Controllable Snubber for Switching Loss Reduction in Interleaved Fly-Back Converter (인터리브드 플라이 백 컨버터의 스위칭 손실 감소를 위한 제어형 스너버에 관한 연구)

  • Park, Chang-Seok;Jung, Tae-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.5
    • /
    • pp.57-64
    • /
    • 2015
  • This paper proposes a new switching algorithm for an controllable clamp snubber to improve the efficiency of a fly-back converter system. This system uses an controllable clamp method for the snubber circuit for the efficiency and reliability of the system. However, the active clamp snubber circuit has the disadvantage that system efficiency is decreased by switch operating time because of heat loss in resonance between the snubber capacitor and leakage inductance. To address this, this paper proposes a new switching algorithm. The proposed algorithm is a technique to reduce power consumption by reducing the resonance of the snubber switch operation time. Also, the snubber switch is operated at zero voltage switching by turning on the snubber switch before main switch turn-off. Experimental results are presented to show the validity of the proposed controllable clamp control algorithm.

Partial O-state Clamping PWM Method for Three-Level NPC Inverter with a SiC Clamp Diode

  • Ku, Nam-Joon;Kim, Rae-Young;Hyun, Dong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1066-1074
    • /
    • 2015
  • This paper presents the reverse recovery characteristic according to the change of switching states when Si diode and SiC diode are used as clamp diode and proposes a method to minimize the switching loss containing the reverse recovery loss in the neutral-point-clamped inverter at low modulation index. The previous papers introduce many multiple circuits replacing Si diode with SiC diode to reduce the switching loss. In the neutral-point-clamped inverter, the switching loss can be also reduced by replacing device in the clamp diode. However, the switching loss in IGBT is large and the reduced switching loss cannot be still neglected. It is expected that the reverse recovery effect can be infrequent and the switching loss can be considerably reduced by the proposed method. Therefore, it is also possible to operate the inverter at the higher frequency with the better system efficiency and reduce the volume, weight and cost of filters and heatsink. The effectiveness of the proposed method is verified by numerical analysis and experiment results.

A Study on PFC of Active Clamp ZVS Flyback Converter (능동 클램프 ZVS 플라이백 컨버터의 역률개선에 관한 연구)

  • 최태영;류동균;이우석;안정준;원충연;김수석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.49-57
    • /
    • 2001
  • This paper analyzed PFC of active clamp ZVS flybark converter by adding two method PFC (Power Factor Correction) circuit-two-stage and single-stage. The addition of active clamp circuit also provide a mechanism fur achieving ZVS of both the primary and auxiliary switches. ZVS also limits the turn off di/dt of the output rectifier, reducing rectifier switching loss and switching noise, due to diode reverse recovery. As a results, the proposed converters have characteristics of the reduced switching noise and high efficiency in comparison to conventional flyback converter. The simulation and experimental results show that the proposed converters improve the input PF of 300[W] ZVS flyback converter by adding single-stage two-stage PFC circuit.

  • PDF

A Study on Efficiency of Active Clamp Type Forward DC-DC Converter (능동 클램프형 포워드 DC-DC 컨버터의 효율에 관한 연구)

  • 안태영
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.5
    • /
    • pp.351-357
    • /
    • 2004
  • In this paper, we present an analytical method that provides fast and efficient evaluation of the conversion efficiency for switching power supplies. In the proposed method, the conduction losses are evaluated by calculating the effective values of the ideal current waveform first and incorporating them into an exact equivalent circuit model of the switching power supply that includes all the parasitic resistances of the circuit components. While the winding losses and core losses are accurately accounted for the magnetic components, the skin and proximity effects are assumed to be negligible in order to simplify the analysis. The validity and accuracy of the proposed method are verified with experiments on a prototype active-clamped forward converter with synchronous rectification. An excellent correlation between the experiments and theories are obtained for the input voltages of 36-75 V with 4-6 MOSFETs employed for the synchronous rectification.

A Study on about Implementation to Induction Cooker that load Turbo Inverter algorithm

  • Lee Min-Ki;Koh Kang-Hoon;Kwon Soon-Kurl;Lee Hyun-Woo;nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.136-139
    • /
    • 2001
  • The voltage resonating inverter has a defect in the switching element that works at 5 or 6 times higher than input voltage. Especially, it is very difficult to choose very high switching device for the 220[V]commercial voltage. In this paper, it is proposed the optimum method to realize the turbo 2000[W] power for induction cooker that is employed the 900[V] IGBT with decreasing operating voltage of the switching component by making the 220[V], 1500[W] inverter through the clamp mode voltage resonating inverter.

  • PDF

Soft Switching Control Method for Photovoltaic AC Module Flyback Inverter using Synchronous Rectifier (동기 정류기를 이용한 태양광 모듈용 플라이백 인버터 소프트 스위칭 제어 기법)

  • Jang, Jin-Woo;Kim, Young-Ho;Choi, Bong-Yeon;Jung, Yong-Chae;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.312-321
    • /
    • 2013
  • In this paper, high efficiency control method for flyback inverter with synchronous rectifier(SR) based on photovoltaic AC modules is proposed. In this control method, the operation of SR is classified according to the voltage spike across main switch SP. When the voltage spike across SP is lower than the rating voltage of SP, the operation of active clamp circuit is interrupted for reducing the switching loss of auxiliary switch. In this time, the SR is operated for soft-switching of SP. When the voltage spike across Sp is higher than the rating voltage of SP, the operation of active circuit is activated for reducing the voltage spike. The SR is operated for reducing the conduction loss of secondary output diode. Thus, a switching loss of the main switch can be reduced in low power region, and weighted-efficiency can be improved. A theoretical analysis and the design principle of the proposed method are provided. And validity is confirmed through simulation and experimental results.

Frequency modulation control for active clamp converter (Active clamp 컨버터의 주파수 변조 제어)

  • Baek J.W.;Son H.S.;Ryu M.H.;Yoo D.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.73-76
    • /
    • 2003
  • A zero voltage soft switching inverter using active clamp is presented for induction heating application. This converter have long been attractive because of its simplicity, high efficiency, and low cost compared to other schemes. In addition to those merits, Input power factor can be improved with a variable frequency control. In this paper, it describe the control method and operational principle to improve a power factor with a single stage US converter using active clamp for induction heating application.

  • PDF