• 제목/요약/키워드: Circulation work

검색결과 188건 처리시간 0.025초

유니버설 디자인 개념이 적용된 장애인을 위한 근무복 디자인 개발 (Development of work uniform design for people with disabilities applying a universal design concept)

  • 김문영
    • 복식문화연구
    • /
    • 제28권3호
    • /
    • pp.344-355
    • /
    • 2020
  • The purpose of this study was to develop a workwear design that takes into account the characteristics of people with severe developmental disabilities who can engage in vocational activities. The aim was to identify needs according to the specific characteristics of people with severe disabilities to design work clothes and develop products according to universal design guidelines. This research method was conducted through representative interviews from a company employing people with severe dis- abilities in Daegu to determine the requirements for workers-related work clothes, and then applied universal design guidelines to perform appropriate design. The results of the study show that the hygiene and warmth of clothing are important for people with developmental disabilities. Therefore, the use of bright materials is required. Second, people with brain lesions often have low body temperature due to difficulties with blood circulation, for which warmth is a required factor. Third, people with severe developmental disabilities should not be differentiated in comparison to people without disabilities, therefore, it was important to use nondiscriminatory designs. Accordingly, it was more efficient to modify and supplement clothing designed for non-disabled people with hidden functions to suit specific characteristics, rather than to develop specialized clothing. These demands were found to conform to what is referred to as a universal design concept, through which three nondiscriminatory shirt designs and two easy-to-use pants were designed.

수지진동증후군 증상 호소율 조사 (An Investigation of the Symptom Prevalence of Hand-Arm Vibration syndrome among the Workers Using Powered Hand Tools)

  • 박희석;임상혁
    • 대한인간공학회지
    • /
    • 제19권3호
    • /
    • pp.93-107
    • /
    • 2000
  • The excessive exposure to powered hand tools can cause damage to nerves, impair blood circulation, and musculoskeletal damage. The symptoms associated with hand-arm vibration syndrome (HAVS) include numbness, tingling, pain and subsequent reduced dexterity of the hands. This study was performed to report the prevalence of the HAVS and evaluate its related factors among the workers using powered hand tools. Total 282 workers in 11 plants of Kyungki and Inchon areas were examined. A standard symptom questionnaire was developed and administered to collect information on personal characteristics, work history, operating conditions, tool characteristics, and subjective symptoms of HAVS. Mean values (standard deviations) of the age, the duration of powered hand tools used, and the daily hours using powered hand tools were 38.3(8.9) years, 79.3(62.2) months and 6.0(2.6) hours, respectively. 132 workers(46.8%) showed vibration-induced white finger symptoms according to the Taylor-Pelmear classification, and 30 workers(10.6%) were interfered with the work. The results of a multiple logistic regression analysis controlling for age and daily working hours showed that smoking, work duration, weight of tools, and continuous work over 2 hours were significantly associated with the symptom of HAVS.

  • PDF

Modeling of Grade Change Operations in Paper Plants

  • 고준석;여영구;하성문;고두석;강홍
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2003년도 추계학술발표논문집
    • /
    • pp.291-305
    • /
    • 2003
  • In this work we developed the closed-loop model of a paper machine during grade change with the intention to provide a reliable dynamic model to be used in the model-based grade change control scheme. During the grade change, chemical and physical characteristics of paper process change with time. It is very difficult to represent these characteristics on-line by using physical process models. In this work, the wet circulation part and the drying section were considered as a single process and closed-loop identification technique was used to develop the grade change model. Comparison of the results of numerical simulations with plant operation data demonstrates the effectiveness of the model identified.

  • PDF

Modeling of Grade Change Operations in Paper Mills

  • Ko, Jun-Seok;Yeo, Yeong-Koo;Ha, Seong-Mun;Lim, Jung-Woo;Ko, Du-Seok;Hong Kang
    • 펄프종이기술
    • /
    • 제35권5호
    • /
    • pp.46-52
    • /
    • 2003
  • In this work we developed the closed-loop model of a paper machine during grade change with the intention to provide a reliable dynamic model to be used in the model-based grade change control scheme. During the grade change, chemical and physical characteristics of paper process change with time. It is very difficult to represent these characteristics on-line by using physical process models. In this work, the wet circulation part and the drying section were considered as a single process and closed-loop identification technique was used to develop the grade change model. Comparison of the results of numerical simulations with mill operation data demonstrates the effectiveness of the model identified.

업무집중 및 커뮤니케이션 행태를 중심으로 한 오피스 레이아웃 유형에 관한 연구 (A Study on Office Layouts focusing Concentration and Communication Behavior)

  • 김두나;하미경
    • 한국실내디자인학회논문집
    • /
    • 제13권6호
    • /
    • pp.29-38
    • /
    • 2004
  • The purpose of this study is to provide design guidelines on office layouts to improve workers' concentration and communication behavior while supporting work processes. Among the present office types, benzene-type was preferred the most was providing better concentration. Regarding communication, link and benzene were preferred types. In present office types, workers were satisfied in communication more than concentration. To increase concentration level, acoustical privacy was indicated as the most important factor In conclusion, to support both concentration and communication in office, the team area should be divided into smaller sub-team areas. The sub-team areas may support interaction within a group while preventing unnecessary distraction. The major circulation of work process should be formed outside of the sub-team areas to provide concentration within the groups.

심장혈관학 분야의 지적구조 규명에 관한 연구 - 국내와 미국을 중심으로 - (A Comparative Analysis on Cardiovascular Research in Korea and the United States)

  • 임지영;정은경
    • 한국비블리아학회지
    • /
    • 제27권1호
    • /
    • pp.111-134
    • /
    • 2016
  • 본 연구는 저자동시인용분석 기법을 이용하여 국내와 미국의 심장혈관학(Cardiovascular Research) 분야의 지적구조 규명을 목적으로 하였다. 이를 위해서 2008년부터 2014년까지 국내의 "대한심장학회지"와 미국의 Circulation, Circulation Research를 선정하여 인용빈도 기준으로 각각 45명과 53명의 저자를 추출하였다. 저자동시인용 행렬을 기반으로 다차원척도분석, 군집분석, 요인분석을 실시하였다. 분석결과는 심장혈관학 분야에서 국내와 미국 연구자들은 공통적으로 여러 분야에 걸쳐 다양한 세부 분야에서 연구 활동을 하는 경향을 보였다. 국내와 미국의 심장혈관학 분야는 핵심연구 영역으로 '심혈관질환 치료', '심혈관질환 진단', '심혈관질환 기초과학', '심혈관질환 예방'으로 나타났다. 국내와 미국의 가장 큰 차이로 볼 수 있는 것은 국내 연구는 임상 중심이며, 미국 연구는 기초 의학 중심인 것으로 나타났다. 국내의 경우는 '리듬장애' 분야가 나타났으며, 이에 반해 미국은 '심혈관계 작용약물' 분야를 찾아볼 수 있다. 또한 미국의 분석결과에서는 기초의학 분야의 세부분야인 '역학', '생물학', '생화학', '생리학' 분야가 뚜렷하게 구분되어 나타났다.

유체 순환 혈압 시뮬레이터의 구현 (Implementation of The Fluid Circulation Blood Pressure Simulator)

  • 김철한;이규원;남기곤;전계록
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권6호
    • /
    • pp.768-776
    • /
    • 2007
  • A new type of the fluid circulation blood pressure simulator was proposed to enhance the blood pressure simulator used for the development and evaluation of automatic sphygmomanometers. Various pressure waveform of fluid flowing in the pipe was reproduced by operating the proportional control valve after applying a pressure on the fluid in pressurized oil tank. After that, appropriate fluid was supplied by operating the proportional control valve, which enabled to reproduce various pressure wave of the fluid flowing in the tube. To accomplish this work, the mathematical model was carefully reviewed in cooperating with the proposed simulator. After modeling the driving signal as input signal and the pressure in internal tube as output signal, the simulation on system parameters such as internal volume, cross-section of orifice and supply pressure, which are sensitive to dynamic characteristic of system, was accomplished. System parameters affecting the dynamic characteristic were analyzed in the frequency bandwidth and also reflected to the design of the plant. The performance evaluator of fluid dynamic characteristic using proportional control signal was fabricated on the basis of obtained simulation result. An experimental apparatus was set-up and measurements on the dynamic characteristic, nonlinearity, and rising and falling response was carried out to verify the characteristic of the fluid dynamic model. Controller was designed and thereafter, simulation was performed to control the output signal with respect to the reference input in the fluid dynamic model using the proposed proportional control valve. Hybrid controller combined with an proportional controller and feed-forward controller was fabricated after applying a disturbance observer to the control plant. Comparison of the simulations between the conventional proportional controller and the proposed hybrid simulator indicated that even though the former showed good control performance.

1/8 척도 CANDU6 감속재 순환 유동 실험에 대한 PIV 속도장 측정 (PIV Measurement of Velocity Profile in the 1/8 Scale CANDU6 Moderator Circulation Test)

  • 김형태;서한;차재은;방인철
    • 한국가시화정보학회지
    • /
    • 제12권1호
    • /
    • pp.18-24
    • /
    • 2014
  • The Korea Atomic Energy Research Institute (KAERI) has a scaled-down moderator test program to simulate the CANDU6 moderator circulation phenomena during steady state operation and accident conditions. In the present work a preliminary experiment using a 1/8 scaled-down moderator tank has been performed to identify the potential problems of the flow visualization and measurement in the scaled-down moderator test facility. With a transparent moderator tank model, a velocity field is measured with a Particle Image Velocimetry (PIV) technique under an isothermal state. The flow patterns from the inlet nozzles to the top region of the tank are investigated using PIV for a 1/8 scale moderator tank.

Simulation of Cardiovascular System for an Optimal Sodium Profiling in Hemodialysis

  • Lim, K.M.;Min, B.G.;Shim, E.B.
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제2권2호
    • /
    • pp.16-26
    • /
    • 2004
  • The object of this study is to develop a mathematical model of the hemodialysis system including the mechanism of solute kinetics, water exchange and also cardiovascular dynamics. The cardiovascular system model used in this study simulates the short-term transient and steady-state hemodynamic responses such as hypotension and disequilibrium syndrome (which are main complications to hemodialysis patients) during hemodialysis. It consists of a 12 lumped-parameter representation of the cardiovascular circulation connected to set-point models of the arterial baroreflexes, a kinetic model (hemodialysis system model) with 3 compartmental body fluids and 2 compartmental solutes. We formulate mathematically this model in terms of an electric analog model. All resistors and most capacitors are assumed to be linear. The control mechanisms are mediated by the information detected from arterial pressoreceptors, and they work on systemic arterial resistance, heart rate, and systemic venous unstressed volume. The hemodialysis model includes the dynamics of urea, creatinine, sodium and potassium in the intracellular and extracellular pools as well as fluid balance equations for the intracellular, interstitial, and plasma volumes. Model parameters are largely based on literature values. We have presented the results on the simulations performed by changing some model parameters with respect to their basal values. In each case, the percentage changes of each compartmental pressure, heart rate (HR), total systemic resistance (TSR), ventricular compliance, zero pressure filling volume and solute concentration profiles are represented during hemodialysis.

  • PDF

좌심방 점액종 1례 보고 (A Case of Left Atrial Myxoma)

  • 유수웅
    • Journal of Chest Surgery
    • /
    • 제11권3호
    • /
    • pp.348-354
    • /
    • 1978
  • Myxoma constitue about 50% of a II primary cardiac, tumor (incidence 0.03%) and occur in any of the cardiac chambers, but about 75% of themare found in the left atrium. As is well known, left atrial myxoma usually simulates mitral valvular disease, and it tends to bring about postural syncope and frequent embolic manifestaticns. The clinical manifestation of left atrial myxoma upon the circulation are obstructive effects, embolic effects and constitutional effects. Diagnosis is now most of all important since surgery can be dramatically curable, whereas untreated myxoma apparently invariably lead to deadful course. Preaprative diagncsis by echocardiogram is so simple and accurate for detection of myxoma that awareness of mitral valvular heart disease with rapid deterioration must be screened. We have diagnosed one case of the left atrial myxoma preopratively by phonocardiogram, echocardiogram and levophase pulmonary angiograJ;n and successfully treated by operation under extra corporeal circulation. A 38 years old housewife was admitted to the National Medical Center because of dyspnea, and paroxysmal cough on occasions for prior to hospitalization. Operation was carried out by median sternotomy and left atriotomy with mild hypothermia under E.C.C. The left atrial myxoma was extirpated including endocardial fragment and its weight was 23gm. The hospital course was not eventful and she can work nowadays without symptoms.

  • PDF