• Title/Summary/Keyword: Circular Vibration

Search Result 515, Processing Time 0.019 seconds

Characterization and behaviors of single walled carbon nanotube by equivalent-continuum mechanics approach

  • Eltaher, Mohamed A.;Almalki, Talaal A.;Ahmed, Khaled I.E.;Almitani, Khalid H.
    • Advances in nano research
    • /
    • v.7 no.1
    • /
    • pp.39-49
    • /
    • 2019
  • This paper focuses on two main objectives. The first one is to exploit an energy equivalent model and finite element method to evaluate the equivalent Young's modulus of single walled carbon nanotubes (SWCNTs) at any orientation angle by using tensile test. The calculated Young's modulus is validated with published experimental results. The second target is to exploit the finite element simulation to investigate mechanical buckling and natural frequencies of SWCNTs. Energy equivalent model is presented to describe the atomic bonding interactions and their chemical energy with mechanical structural energies. A Program of Nanotube modeler is used to generate a geometry of SWCNTs structure by defining its chirality angle, overall length of nanotube and bond length between two adjacent nodes. SWCNTs are simulated as a frame like structure; the bonds between each two neighboring atoms are treated as isotropic beam members with a uniform circular cross section. Carbon bonds is simulated as a beam and the atoms as nodes. A finite element model using 3D beam elements is built under the environment of ANSYS MAPDL environment to simulate a tensile test and characterize equivalent Young's modulus of whole CNT structure. Numerical results are presented to show critical buckling loads, axial and transverse natural frequencies of SWCNTs with different orientation angles and lengths. The understanding of mechanical behaviors of CNTs are essential in developing such structures due to their great potential in wide range of engineering applications.

Design and Fabrication of a 2-Axis Waveguide Rotary Joint for a Millimeter-wave (Ka-Band) Multi-Mode Seeker with Low VSWR and Insertion Loss (낮은 정재파비와 삽입손실을 갖는 밀리미터파(Ka 밴드) 복합모드 탐색기용 2-축 도파관 로터리 조인트 설계 및 제작)

  • Song, Sung-Chan;Yoo, Sung-Ryong;Lim, Ju-Hyun;Jung, Yong-In
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.2
    • /
    • pp.173-176
    • /
    • 2019
  • In this study, a Ka-band waveguide rotary joint that can be applied to a millimeter-wave seeker is designed and fabricated. The proposed rotary joint maintains a low standing-wave ratio and low-loss characteristics, and has two rotary axes designed to enable azimuth and elevation rotation. The rotary joint is designed as a ridge-waveguide-type mode converter and a ${\lambda}/4$ choke structure to match the electromagnetic wave propagation mode between the spherical and circular waveguides. A performance test using a network analyzer and a high-power transmitter to assess vibration and shock were conducted. Results showed that the rotary joint had a very low standing-wave ratio of less than the maximum of 1.19:1 and an insertion loss of less than 0.80 dB at $F_C{\pm}500MHz$.

Vibrational characteristics of sandwich annular plates with damaged core and FG face sheets

  • Xi, Fei
    • Steel and Composite Structures
    • /
    • v.44 no.1
    • /
    • pp.65-79
    • /
    • 2022
  • The main goal of this paper is to study the vibration of damaged core laminated annular plates with FG face sheets based on a three-dimensional theory of elasticity. The structures are made of a damaged isotropic core and two external face sheets. These skins are strengthened at the nanoscale level by randomly oriented Carbon nanotubes (CNTs) and are reinforced at the microscale stage by oriented straight fibers. These reinforcing phases are included in a polymer matrix and a three-phase approach based on the Eshelby-Mori-Tanaka scheme and on the Halpin-Tsai approach, which is developed to compute the overall mechanical properties of the composite material. In this study the effect of microcracks on the vibrational characteristic of the sandwich plate is considered. In particular, the structures are made by an isotropic core that undergoes a progressive uniform damage, which is modeled as a decay of the mechanical properties expressed in terms of engineering constants. These defects are uniformly distributed and affect the central layer of the plates independently from the direction, this phenomenon is known as "isotropic damage" and it is fully described by a scalar parameter. Three complicated equations of motion for the sectorial plates under consideration are semi-analytically solved by using 2-D differential quadrature method. Using the 2-D differential quadrature method in the r- and z-directions, allows one to deal with sandwich annular plate with arbitrary thickness distribution of material properties and also to implement the effects of different boundary conditions of the structure efficiently and in an exact manner. The fast rate of convergence and accuracy of the method are investigated through the different solved examples. The sandwich annular plate is assumed to have any arbitrary boundary conditions at the circular edges including simply supported, clamped and, free. Several parametric analyses are carried out to investigate the mechanical behavior of these multi-layered structures depending on the damage features, through-the-thickness distribution, and boundary conditions.

Hydrogen Fluoride Vapor Etching of SiO2 Sacrificial Layer with Single Etch Hole (단일 식각 홀을 갖는 SiO2 희생층의 불화수소 증기 식각)

  • Chayeong Kim;Eunsik Noh;Kumjae Shin;Wonkyu Moon
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.328-333
    • /
    • 2023
  • This study experimentally verified the etch rate of the SiO2 sacrificial layer etching process with a single etch hole using vapor-phase hydrogen fluoride (VHF) etching. To fabricate small-sized polysilicon etch holes, both circular and triangular pattern masks were employed. Etch holes were fabricated in the polysilicon thin film on the SiO2 sacrificial layer, and VHF etching was performed to release the polysilicon thin film. The lateral etch rate was measured for varying etch hole sizes and sacrificial layer thicknesses. Based on the measured results, we obtained an approximate equation for the etch rate as a function of the etch hole size and sacrificial layer thickness. The etch rates obtained in this study can be utilized to minimize structural damage caused by incomplete or excessive etching in sacrificial layer processes. In addition, the results of this study provide insights for optimizing sacrificial layer etching and properly designing the size and spacing of the etch holes. In the future, further research will be conducted to explore the formation of structures using chemical vapor deposition (CVD) processes to simultaneously seal etch hole and prevent adhesion owing to polysilicon film vibration.

The Study on the Relationship Between the Duration of Chest Vibration prior to Endotracheal Suctioning and the Changes in Oxygen Saturation in Low-Birth-Weight Infants (저체중아에 있어 기관내 흡인전 흉부진동법의 기관과 산소포화 변화간의 관계 연구)

  • Ahn, Young-Mee
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.3
    • /
    • pp.597-607
    • /
    • 1995
  • 1960년대 이후 인공호흡기(mechanical ventilator)의 보급과 최근 의료과학의 발달, 간호의 질적 향상의 결과로 저체중출생아를 포함한 고위험 신생아의 생존율이 높아져왔다. 호흡장애증후군(RDS)은 일차적으로 폐포의 완전한 확장을 위해 필요한 계면활성물질(surfactant)의 부족, 미발달된 심폐기능에 의한 병리적 현상으로 저체중아의 가장 큰 원인이 되어왔다. RDS로 인해 인공호흡기에 의존해 있는 저체중아의 경우 적절한 산소공급과 이를 위한 호흡의 유지는 치료의 가장 큰 핵심이 되며, 이를 위한 기관내 흑은 비인두 흡인 (nasopharyngeal suction)은 신생아 중환자실(NICU)의 가장 중요한 간호행위가 되어왔다. 인공호흡기를 위한 기관삽관은 그 자체가 기도의 성모운동을 방해하고 기침반사를 억제시켜 폐 분비물의 효과적 배출을 억제하며, 특히 저체중아의 경우 조산과 관련하여 미발달된 흥곽운등과 심폐기능은 폐분비물의 이동을 저해하는 요소이다. 따라서 기도내의 분비물의 이동을 효과적으로 하여 흡인 시에 최대한의 효과를 돕기 위해 흥곽 물리요법(chest physiotheraphy : CPT)의 한 형태인 흉곽진동법 (Chest Vibration : CV)가 행해져 왔다. 그러나 저체중아를 위한CV의 임상적 적용은 그 대상의 생리적 특성, CV의 적용부위(site)와 기간(duration)에 대한 과학적 근거 없이 만성감염이나 폐질환을 가진 성인이나 cystic fibrosis환자를 위한 CV protocol을 무분별하게 채택하여 저체중아에게 행하여져 왔다 이에 본 연구자는 저체중아에 대한 CV의 안전성을 평가하고, 이에 기초하여 저체중아에게 바람직한CV의 형태를 알아보고자 본 연구를 시작하였다. 연구설계는 CV의 안전성을 평가하기 위한 실험연구이다. CV의 안전성은 RDS치료의 가장 일차적 목표인 oxygenation변화에 의해 평가될 수 있으므로, 본 실험 연구에서는 Pulse oximeter에 의해 계속적으로 측정된 산소포화 변화(oxygen saturation change)를 측정하였다. 실험대상은 미국동부에 위치한 대학병원의 NICU에 입원하여 RDS와 관련된 호흡장애로 인공호흡기에 의존해 있는 10명의 저체중아였다. 인공호흡기에 의존된 모든 저체중아는 Pulse oximeter와 심폐기능 측정기(cardiopulmonary monitor)에 의해 산소공급과 호흡상태가 계속 측정되고 있었다. 실험대상의 평균 출생시 몸무게는 평균 1,3050gm(SD=580.6)이었고, 임신월령 은 평균 28.6주(SD=3.1)였다. RDS가 그들의 일차적 진단명이었고, 그중 4명은 pneumonia, atelectasis의 합병증을 가지고 있었다. 10명중 6명은 intermittent mandatory ventilation(IMV)의 형태로, 4명은 continuous positive airway pressure(CPAP)의 형태로 인공호흡기에 의존되어 있었고 CV시의 FiO2는 평균 42.3(SD=21.2)였다. CV는 중환아용 소형진동기 (minivibrator)를 이용해 가각 10명 의 간호사에 의해 행하여 졌고, 최소 22초에서 최대 100초 동안 실시되었다. 50%의 간호사는 30초에서 40초간 CV를 실시하였으며, CV의 적용부위도, 전후 흉곽부위, 혹은 병변이 있는 좌 우측, 흑은 양쪽 흉벽 등으로 다양했고, 적용방법도 원형으로 돌려가며(circular motion), 혹은 아래에서 위로, 혹은 아무런 기준없이 간호사의 기호에 따라 다양하게 적용되었다. 산소포화의 변화는 CV가 행해지기 전.후로 5초동안 관찰되었다. 연구의 결과, 산소포화 변화는 비 모수통계(non parametric statistics)의 일종인 Matched Paired Wilcoxon test로 분석 한 결과 CV후에 3%의 감소를 보였다(P<.05). 저체중아에 있어 산소포화의 3%감소는 임상적으로 중요한 의미가 없다고 사료되어지며, 실제 흡인전의 과도호흡에 의해 CV를 행하기 이전의 산소공급수준으로 돌아 왔다. CV실시 기간과 산소포화와의 상관관계는 비 모수통계인 Spearman rho correlation coefficient를 이용하여 분석하였는데, 이 두 변수는 서로 관계가 없는 것으로 나타났다(P>.05) 또한 CV와 흡인 후에 각각의 간호사들에게 CV를 필요로 한 저체중아의 기준, 적용부위, 기간, 방법등에 대한 기준을 물었으나 대상의 특성에 따른 간호사정에 의존하기보다는 간호사 각자의 선호하는 방법이나 습관에 라 행하는 것으로 나타났다. 결론적으로 CV와 산소포화 변화와의 관계, NICU에서 관찰된 CV의 임상적 적용을 기초로 저체중아에게 안전한 CV protocol은 신생아용 소형 진동기를 이용하여, 양쪽 흉곽의 늑골하측 변연 부위(low lateral costal margin)에서 시작하여 흉골 중앙부위 방향으로 30초 동안 진동기를 적용하는 것이 좋은 것으로 나타났다. 이에 CV의 효과를 평가하기 위한 보다 과학적인 접근방법으로, CV와 흡인의 결과인 가래(sputum)에 대한 연구를 제언하는 바이다.

  • PDF