• Title/Summary/Keyword: Circular Column

Search Result 324, Processing Time 0.019 seconds

Shear Capacity Curve Model for Seismic Design of Circular RC Bridge Columns (RC 원형교각의 내진설계를 위한 전단성능곡선)

  • Lee Jae Hoon;Ko Seong Hyun;Choi Jin Ho;Kwon Soon Hong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.93-96
    • /
    • 2005
  • Since the columns with flexure-shear failure have lower ductility than those with flexural failure, shear capacity curve models shall be applied as well as flexural capacity curve in order to determine ultimate displacement for seismic design or performance evaluation. In this paper, a modified shear capacity curve model is proposed and compared with the other models such as the CALTRANS model, Aschheim et al.'s model, and Priestley et al.'s model. Four shear capacity curve models are applied to the 4 full scale circular bridge column test results and the accuracy of each model is discussed. It may not be fully adequate to drive a final decision from the application to the limited number of test results, however the proposed model provides the better prediction of failure mode and ultimate displacement than the other models for the selected column test results.

  • PDF

A Comparative Study of P-M Interaction Curve of the Circular Concrete Column according to Design for Standard (설계 기준에 따른 휨,압축 부재의 P-M상관도 비교)

  • Kim, Hee-Yong;Kim, Young-Jin;Kim, Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.143-144
    • /
    • 2010
  • As KCI under U.S.D is impossible to calculate all sections compared P-M Interaction Curve of the circular concrete column under EC2 of limit state design and KCI. Result of the construction, P-M Interaction Curve according to design for standard is about the same. If a covering depth rased, EC2 is better safety than KCI.

  • PDF

Seismic Performance of RC Circular Colunm-Bent Piers under Bidirectional Repeated Loadings according to Main Loading Direction (2축 반복하중을 받는 2주형 RC 원형교각의 주하중방향에 따른 내진성능평가)

  • Park, Chang-Kyu;Lee, Beom-Gi;Yun, Sang-Cheol;Chung, Young-Soo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.284-291
    • /
    • 2005
  • A RC column-bent pier represents one of the most popular piers used in highway bridges. Seismic performance of reinforced concrete (RC) column-bent piers under bidirectional seismic loadings was experimentally investigated. Six column bent-piers were constructed with two circular supporting columns which were made in 400mm diameter and 2,000mm height. Test parameters are different transverse reinforcement and loading pattern. These piers were tested under lateral load reversals with the axial load of $0.1f_{ck}A_g$. Three specimens were subjected to bidirectional lateral load cycles which consisted of two main longitudinal loads and two sub transverse loads in one load cycle. Other three specimens were loaded in the opposite way. Test results indicated that lateral strength and ductility of the latter three specimens were generally bigger than those of the former three specimens. Plastic hinges were formed with the spall of cover concrete and the fracture of the longitudinal reinforcing steels in the bottom plastic hinge of two supporting columns for the former three specimens. Similar behavior was observed in the top and bottom parts of two supporting columns for the latter three specimens.

  • PDF

Structural Characteristics of Beam-to-Column Connection of Circular CFT Columns by Using Mixed Diaphragms (혼합다이아프램 형식을 적용한 콘크리트충전 원형강관 기둥-보 접합부의 구조적 특성)

  • Wang, Ning;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.3
    • /
    • pp.299-310
    • /
    • 2015
  • CFT(Concrete-Filled Tube) structures have problems at processing cause closed section and concrete filling problems. In this study, a CFT structure that uses different types of diaphragms in its upper and lower connections to improve the concrete filling was tested and analyzed via the FEM program. Implementation of variable analysis of EP-T type to find out the reason that effect on the resistance force of the connection. As a result, through experiments and analysis investigated the structural characteristics of circular CFT beam-to-column connection.

Axial compression behavior of circular recycled concrete-filled steel tubular short columns reinforced by silica fume and steel fiber

  • Chen, Juan;Liu, Xuan;Liu, Hongwei;Zeng, Lei
    • Steel and Composite Structures
    • /
    • v.27 no.2
    • /
    • pp.193-200
    • /
    • 2018
  • This paper presents an experimental work for short circular steel tube columns filled with normal concrete (NAC), recycled aggregate concrete (RAC), and RAC with silica fume and steel fiber. Ten specimens were tested under axial compression to research the effect of silica fume and steel fiber volume percentage on the behavior of recycled aggregate concrete-filled steel tube columns (RACFST). The failure modes, ultimate loads and axial load- strain relationships are presented. The test results indicate that silica fume and steel fiber would not change the failure mode of the RACFST column, but can increase the mechanical performances of the RACFST column because of the filling effect and pozzolanic action of silica fume and the confinement effect of steel fiber. The ultimate load, ductility and energy dissipation capacity of RACFST columns can exceed that of corresponding natural aggregate concrete-filled steel tube (NACFST) column. Design formulas EC4 for the load capacity NACFST and RACFST columns are proposed, and the predictions agree well with the experimental results from this study.

Development of Connection between CFT Column and Pier Foundation for Top-Down Construction (Top-Down 공사용 원형충전강관기둥과 피어기초의 개발)

  • Jeong, Mee-Ra;Rhim, Hong-Chul;Kim, Seung-Weon;Kim, Dong-Gun;Kang, Seung-Ryong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.29-32
    • /
    • 2009
  • Building foundations for Top-Down construction require a special setting, because the foundations have to be placed way before excavation for the substructure of main building, Usually, the foundation goes into the layer of rock and it is often called rock-pier foundation, Currently, a cage of steel reinforcing bars is inserted to the pre-excavated hole in the rock layer, hanging down from the wide flange steel column above. This paper presents a new method for connecting the prefounded column and the steel cage with a coupler for better connection between the two, The use of a circular Concrete Filled Tube (CFT) as a prefounded column makes it possible to have this type of connection. The details of the connection and application to a Top-Down construction site is also included in this paper.

  • PDF

Restoring force model for circular RC columns strengthened by pre-stressed CFRP strips

  • Zhou, Changdong;Lu, Xilin;Li, Hui;Tian, Teng
    • Steel and Composite Structures
    • /
    • v.17 no.4
    • /
    • pp.371-386
    • /
    • 2014
  • This paper presents a tri-linear restoring force model based on the test results of 12 circular RC columns strengthened by CFRP strips under low cyclic loading. The pre-stress of CFRP strips and axial load ratio of specimens are considered as the affect parameters of the proposed model. All essential characteristics of the hysteretic behavior of the proposed model, including the hysteretic rules, main performance points, strength degradation, stiffness degradation and confinement effects are explicitly analyzed. The calculated results from the proposed model are in good agreement with the experimental results, which shows that the recommended model can be reliably used for seismic behavior predictions of circular RC columns strengthened by pre-stressed CFRP strips.

Strength Evaluation of T-type Tubular Joints for Circular Section Multi-Column Wind Towers (원형단면 멀티기둥 풍력타워 적용 T형 강관조인트 강도 평가)

  • Kim, Kyung Sik;Park, Hyun Yong;Seo, Dong Hyuck
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.1
    • /
    • pp.119-129
    • /
    • 2015
  • Due to reduced self weight and alleviated wind effect, the multi-column wind towers that consist of a number of circular tubes as vertical members interconnected with horizontal brace members can be a substitute for the large-scale single cylinder wind towers. It is critical to guarantee strengths of tubular joints where vertical and horizontal members are structurally connected in order to make the whole multi-column system behave as a single tower structure. In this study, strength evaluation has been conducted for T-type tubular joints that are applicable in multi-column towers. Four of available design codes, i.e., AISC, Eurocode3, ISO 19902, CIDECT have been investigated and predictor equations in the considered design codes were validated and discussed through parametric numerical study on slenderness ratios of chords and braces at joints.

Rocking behavior of bridge piers with spread footings under cyclic loading and earthquake excitation

  • Hung, Hsiao-Hui;Liu, Kuang-Yen;Chang, Kuo-Chun
    • Earthquakes and Structures
    • /
    • v.7 no.6
    • /
    • pp.1001-1024
    • /
    • 2014
  • The size of spread footings was found to be unnecessarily large from some actual engineering practices constructed in Taiwan, due to the strict design provisions related to footing uplift. According to the earlier design code in Taiwan, the footing uplift involving separation of footing from subsoil was permitted to be only up to one-half of the foundation base area, as the applied moment reaches the value of plastic moment capacity of the column. The reason for this provision was that rocking of spread footings was not a favorable mechanism. However, recent research has indicated that rocking itself may not be detrimental to seismic performance and, in fact, may act as a form of seismic isolation mechanism. In order to clarify the effects of the relative strength between column and foundation on the rocking behavior of a column, six circular reinforced concrete (RC) columns were designed and constructed and a series of rocking experiments were performed. During the tests, columns rested on a rubber pad to allow rocking to take place. Experimental variables included the dimensions of the footings, the strength and ductility capacity of the columns and the intensity of the applied earthquake. Experimental data for the six circular RC columns subjected to quasi-static and pseudo-dynamic loading are presented. Results of each cyclic loading test are compared against the benchmark test with fixed-base conditions. By comparing the experimental responses of the specimens with different design details, a key parameter of rocking behavior related to footing size and column strength is identified. For a properly designed column with the parameter higher than 1, the beneficial effects of rocking in reducing ductility and the strength demand of columns is verified.

SEismic Performance of Circular RC Bridge Piers designed in Moderate on low Seismic Zone (중.약진 지역의 원형 내진 RC 교각의 내진성능평가)

  • 박종협;조창백;박희상;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.452-457
    • /
    • 2000
  • This research aims at evaluating the seismic performance of the existing R/C bridge piers, which were seismically designed in accordance with the provision of moderate confinement design code (Eurocode 8). The work presented in this paper experimentally investigates the ductility and hysteretic behavior of circular reinforced concrete columns with moderate confinement. Pseudo-dynamic tests have been carried out on two scaled R/C column specimens to investigate their hysteretic behavior and other seismic performance.

  • PDF