A Dynamic Camera Actuation System for Simultaneous in Situ Image Acquisition on a Lab-on-a-disk (랩-온-어-디스크를 위한 실시간 영상 조절 및 이미지 획득 시스템)

  • La, Moonwoo;Park, Sang Min;Park, Sung Jea;Kim, Dong Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.11
    • /
    • pp.1211-1216
    • /
    • 2013
  • In this study, a dynamic camera actuation system for simultaneous in situ image acquisition is developed to achieve real-time observation of transient liquid flow on a lab-on-a-disk. A disk-type electric circuit, namely circuit-on-a-disk, co-rotated with the lab-on-a-disk improves the dynamic image acquisition ability in terms of a frame rate. The circuit-on-a-disk is comprised of a camera connected with a motor, a microprocessor and a wireless communication module. The camera connected with the motor enables to realize dynamic tracking of a transient flow and real-time image acquisition. The obtained images can be simultaneously transferred by a video/audio transmitter unit to a personal computer. Also, the microprocessor receives signals from the personal computer, and then controls the focusing position of the camera. We are expecting that heaters, sensors, and light sources also can be integrated on the circuit-on-a-disk, and they will enable various functional actuations as well as precise image acquisition.

Development of the Oil Consumption Rate Test Method and Measurement Data Analysis for an Automatic Transmission System (자동변속기 오일 소요유량 시험법개발 및 측정데이터 분석)

  • Jeong, H.S.;Oh, S.H.;Yi, J.S.;Lim, J.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.1
    • /
    • pp.10-16
    • /
    • 2009
  • Automatic power transmission systems consisted of a torque converter and several planetary gear sets, clutches and brakes are controlled by a hydraulic shift control circuit and an electronic transmission control unit. The hydraulic circuit serves for the operation of the torque converter and lubrication oil supply of the transmission system as well as for the actuation of clutches for the automatic gear shift. The complicated hydraulic control circuit constructed by many spools, solenoids, orifices and flow passages are integrated into one small valve block and it is powered by one hydraulic pump. In this paper, a test equipment was developed to measure the oil consumption of each component at various wide operating conditions. Test data about 730 sets acquired from five test items are analyzed and discussed on the oil capacity of the circuit.

  • PDF

A study on simulation to current flow by short circuit of medical machine (대형의료기기의 회로 단락시 전류흐름에 대한 시뮬레이션 연구)

  • Choi, Do-Soon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.5 no.4
    • /
    • pp.211-215
    • /
    • 2012
  • Surgery equipment in operating room is very important at treatment procedure of patients. In this circuit of large equipment, a sudden change of current make big problem such as short circuit. when the current is converted suddenly, the current converter becomes in saturate and it caused by the induction curve of the inductor. in this case, the rates of the primary and secondary winding are broken and it becomes a open circuit. in this paper, we will look around the current transform of the primary and secondary winding when current converter becomes in saturate.

Characteristic of air-side sensible heat transfer and pressure drop on the corrugate fin tube heat exchangers (Corrugate 휜-관 현열 열교환기의 구조에 따른 공기측 열전달 및 압력손실 특성)

  • Ryu, Joon-Il;Jeon, Chang-Duk;Lee, Jin-Ho;Nam, Leem-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.216-221
    • /
    • 2007
  • An experiment was carried out to investigate the effect of a coolant circuit arrangement on the heat transfer and air pressure drop of a fin-tube sensible heat exchanger with the corrugated fin surface. The air inlet temperature was set to $23^{\circ}C$,the relative humidity to 50% and the air inlet flow rate to 20, 22, $25m^3/min$, respectively. while the coolant temperature was set to $7^{\circ}C$, and the coolant mass flow rate to 10, 16, 22kg/min, respectively. Experiment showed that the exchanger having a diameter of 12.7mm with parallel circuit does better performance in sensible heat transfer and air pressure drop than those three of diameter of 12.7mm with a series circuit and that with diameter of 15.88mm with a parallel circuit.

  • PDF

Implementation of Recursive DSP Algorithms Based on an Optimal Multiprocessor Scheduler (최적 멀티프로세서 스케줄러를 이용한 재귀 DSP 알고리듬의 구현)

  • Kim Hyeong-Kyo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.2
    • /
    • pp.228-234
    • /
    • 2006
  • This paper describes a systematic process which can generate a complete circuit specification efficiently for a given recursive DSP algorithm based on an optimal multiprocessor scheduler. The process is composed of two states: scheduling and circuit synthesis. The scheduling part accepts a fully specified flow graph(FSFG) as an input, and generates an optimal synchronous multiprocessor schedule. Then the circuit synthesis part translates the modified schedule into a complete circuit diagram including a control specification. The circuit diagram can be applied to a silicon compiler for VLSI layout generation. This paper illustrates the whole process with an example of a second order Gray-Market lattice filter.

A numerical study of design condition for horizontal electronic circuit boards flow and heat transfer characteristics (유동과 열전달 특성을 고려한 수평 전자회로 기판의 설계조건에 관한 수치적 연구)

  • 전운학;이행남;김현모
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.76-87
    • /
    • 1992
  • Flow and heat transfer characteristics in a horizontal electronic circuit board are studied numerically. The board has the arrays of heated blocks and the spaces between the plates and blocks are changed. Air in used as cooling fluid, of which prandt1 number is 0.7. The velocity distributions, temperature distributions, Nusselt numbers and dimensionless friction factors are obtained on the spaces between the plates and the blocks, for the cases of Rayleigh number, 0 and 10$^{5}$ . When Rayleigh number is so large, such as 10$^{5}$ , that the effect of bouyancy is not negligible, fluid friction and heat transfer is increased more than those of forced convection. This may be caused by the generation of secondary flow on the cross section of primary flow. The effect of bouyancy is of the most efficient, when the space of blocks is about block-width and the space of plates is about 1.7 times of block-height.

  • PDF

Visualization of the Slurry Flow-Field during Chemical Mechanical Polishing by PIV (PIV를 이용한 Chemical Mechanical Polishing 공정 중의 연마용액 유동흐름 측정)

  • Shin Sanghee;Kim MunKi;Yoon Youngbin;Koh Young-Ho
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.48-51
    • /
    • 2004
  • Chemical Mechanical Polishing(CMP) is popularly used in production of semiconductor because of large area polishing ability probability of improvement for more integrated circuit. However, present CMP processing causes some non-uniformity errors which can be critical for highly integrated circuit. Previous studies predict that flow-field of slurry during CMP can create non-uniformity, but no quantitative measurement has conducted. In this study, using PIV, slurry velocity flow-field during CMP is measured by changing the ratio of RPM of pad and carrier with tuned PIV system adequate for small room in CMP machine and Cabot's non-groove pad Epad-A100. The result show that velocity of slurry is majorly determined by pad-rpm and the ratio of between carrier and pad rpm make some changes in streamlines.

  • PDF

The application of a numerical technique to the current interruption properties of 800kV gas circuit breaker - Characteristics of gas flow (800kV 가스차단기의 차단성능평가를 위한 수치해석 적응 - 유동특성)

  • Choi, Y.K.;Song, K.D.;Park, K.Y.;Shin, Y.J.;Chulkov, V.V.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1888-1891
    • /
    • 1996
  • Recently, FLIC(Fluid In Cell) method has been widely used for the compressible. flow computation. A program which adopts the FLIC method and can analyze the flow conditions with arc in the interrupter was developed in our team. It was applied to the 800kV class gab circuit breaker for flow conditions with arc, and the results are presented and discussed in this paper.

  • PDF

Numerical Simulation of Oil Supply System of Reciprocating Compressor for Household Refrigerators (냉장고용 왕복동 압축기 급유 시스템의 수치해석)

  • Kim, H.J.;Lee, J.K.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.24-30
    • /
    • 2005
  • For a reciprocating compressor of household refrigerators, a direct analogy between the pipe flow network and the electric circuit network has been utilized to set up a mathematical model for oil supply system. Individual lubrication elements of the oil supply system, such as propeller- installed oil cap, oil galleries, radial oil feeding holes, spiral oil grooves, and various sliding surfaces have been analogized by equivalent electric elements, and these have been combined together to form an electric circuit corresponding to the whole oil supply system. By solving the closed network equations of the model, oil flow rates at various lubrication elements could be obtained. Total amount of the oil flow rate drawn into the shaft has been measured and compared reasonably well with the prediction of the numerical simulation.

  • PDF

Corrosion Behavior of Nickel-Plated Alloy 600 in High Temperature Water

  • Kim, Ji Hyun;Hwang, Il Soon
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.61-67
    • /
    • 2008
  • In this paper, electrochemical and microstructural characteristics of nickel-plated Alloy 600 were investigated in order to identify the performance of electroless Ni-plating on Alloy 600 in high-temperature aqueous condition with the comparison of electrolytic nickel-plating. For high temperature corrosion test of nickel-plated Alloy 600, specimens were exposed for 770 hours to typical PWR primary water condition. During the test, open circuit potentials (OCP's) of all specimens were measured using a reference electrode. Also, resistance to flow accelerated corrosion (FAC) test was examined in order to check the durability of plated layers in high-velocity flow environment at high temperature. After exposures to high flow rate aqueous condition, the integrity of surfaces was confirmed by using both scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). For the field application, a remote process for electroless nickel-plating was demonstrated using a plate specimen with narrow gap on a laboratory scale. Finally, a practical seal design was suggested for more convenient application.