• Title/Summary/Keyword: Circuit testing

Search Result 419, Processing Time 0.029 seconds

A Method on Improving the Efficiency of Random Testing for VLSI Test Cost Reduction (반도체 테스트 비용 절감을 위한 랜덤 테스트 효율성 향상 기법)

  • Sungjae Lee;Sangseok Lee;Jin-Ho Ahn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.1
    • /
    • pp.49-53
    • /
    • 2023
  • In this paper, we propose an antirandom pattern-based test method considering power consumption to compensate for the problem that the fault coverage through random test decreases or the test time increases significantly when the DUT circuit structure is complex or large. In the proposed method, a group unit test pattern generation process and rearrangement process are added to improve the problems of long calculation time and high-power consumption, which are disadvantages of the previous antirandom test.

  • PDF

An Omnidirectional High Gain Antenna for UHF Band Ground Station (UHF대역 지상국용 무지향 고이득 안테나)

  • Bae, Ki-Hyoung;Chang, Min-Soo;Joo, Jae-Woo;Hwang, Chan-Ho;Hong, Ki-Pyo
    • Journal of the Korea Knowledge Information Technology Society
    • /
    • v.12 no.4
    • /
    • pp.539-550
    • /
    • 2017
  • In this paper, we designed, fabricated and tested an UHF band cylindrical dipole array antenna. In the proposed antenna, cylindrical dipoles were vertically arranged in four stages. A parallel structure feeding circuit was installed inside the cylindrical dipole and mounted so as to be broadband matching. The feeding circuit was installed at the center of the cylindrical dipole to optimize the gain flatness characteristic of the azimuth direction omnidirectional radiation pattern. Minimizing the difference between the signals branched from the feeding circuit and realizing the symmetry of the radiation pattern. The required specifications are more than 11.2% bandwidth in UHF band, above 6dBi antenna gain, standing wave ratio of 2:1 or less, less than ${\pm}1dB$ gain flatness in azimuth radiation pattern, more than 13 degrees in elevation radiation pattern of 3dB beamwidth. We confirmed the possibility of implementation through M&S and verified the result of M&S through production and testing. The test results are 11.2% bandwidth in the UHF band, 6.30 to 8.31 dBi gain, 1.53:1 standing wave ratio or less, within ${\pm}0.2dB$ gain flatness in the azimuth radiation pattern, elevation radiation pattern of 3dB beam width was 15.62 to 15.84 degrees. The test result meets all requirements specifications.

Fiber Optic Bragg Grating Sensor for Crack Growth Detection of Structures (구조물의 균열 진전 탐지를 위한 광섬유 브래그 격자 센서)

  • Kwon, Il-Bum;Seo, Dae-Cheol;Kim, Chi-Yeop;Yoon, Dong-Jin;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.299-304
    • /
    • 2007
  • There are to be some cracks on the material degradation part or the stress concentration parts of the main members, which carry on over-loads, of structures. Because these cracks can be used to evaluate the structural health status, it is important to monitor the crack growth for maintaining the structural safety. In this study, the fiber Bragg grating sensor with a drop ball was developed as a sensor for crack growth detection of an existing crack. The crack growth detection sensor was constructed with three parts: a probe part, a wavelength controling light source and receiver part, and an impact part. The probe part was just formed with a fiber Bragg grating optical fiber The wavelength controling light source part was composed of a current supplying circuit, a DFB laser diode, and a TEC controling circuit for wavelength control. Also, the impact part was just implemented by dropping a steel ball. The performance of this sensor was confirmed by the experiments of the crack detection with an aluminum plate having one existing crack. According to these experiments, the difference of the sensor signal outputs was correlated with the crack length. So, it was confirmed that this sensor could be applied to monitor the crack growth.

A Study on Safety and Performance Evaluation of Smart All-in-one Cardiopulmonary Assist Device (스마트올인원 심폐순환보조장치의 안전성 및 성능평가에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Yerim;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.197-205
    • /
    • 2019
  • The existing Extracorporeal membrane oxygenation(ECMO) and Cardiopulmonary bypass system(CPB) have been developed and applied to various devices according to their respective indications. However, due to the complicated configuration and difficult usage method, it causes inconvenience to users and there is a risk of an accident. Therefore, smart all-in-one cardiopulmonary circulation device is being developed recently. The smart all-in-one cardiopulmonary assist device consists of a blood pump for cardiopulmonary bypass, a blood oxidizer for cardiopulmonary bypass, a blood circuit for cardiopulmonary bypass, and an artificial cardiopulmonary device. It is an integrated cardiopulmonary bypass device that can be used for a variety of purposes such as emergency, intraoperative, post-operative intensive care, and long-term cardiopulmonary assist, combined with CPB used in open heart surgery and ECMO used when patient's cardiopulmonary function does not work normally. The smart all-in-one cardiopulmonary assist device does not exist as a standard and international standard applicable to advanced medical devices. Therefore, in this study, we will refer to the International Standard for Blood Components, the International Standard for Blood, the Guideline for Blood Products, and prepare applicable performance and safety guidelines to help quality control of medical devices, and contribute to the improvement of the health of people. The guideline, which is the result of conducted a survey of the method of safety and performance test, is based on the principle of all-in-one cardiopulmonary aiding device, related domestic foreign standards, the status of domestic and foreign patents, related literature, blood pump(ISO 18242), blood oxygenator (ISO 7199), and blood circuit (ISO 15676) for cardiopulmonary bypass.The items on blood safety are as follows: American Society for Testing and Materials ASTM F1841-97R17), and in the 2010 Food and Drug Administration's Safety Assessment Guidelines for Medical Assisted Circulatory Devices. In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers / importers, testing inspectors, academia, etc. the final guideline was established through revision and supplementation process. Therefore, we propose guidelines for evaluating the safety and performance of smart all-in-one cardiopulmonary assist devices in line with growing technology.

A Built-In Self-Test Architecture using Self-Scan Chains (자체 스캔 체인을 이용한 Built-In Self-Test 구조에 관한 연구)

  • Han, Jin-Uk;Min, Hyeong-Bok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.3
    • /
    • pp.85-97
    • /
    • 2002
  • STUMPS has been widely used for built-in self-test of scan design with multiple scan chains. In the STUMPS architecture, there is very high correlation between the bit sequences in the adjacent scan chains. This correlation causes circuits lower the fault coverage. In order to solve this problem, an extra combinational circuit block(phase shifter) is placed between the LFSR and the inputs of STUMPS architecture despite the hardware overhead increase. This paper introduces an efficient test pattern generation technique and built-in self-test architecture for sequential circuits with multiple scan chains. The proposed test pattern generator is not used the input of LFSR and phase shifter, hence hardware overhead can be reduced and sufficiently high fault coverage is obtained. Only several XOR gates in each scan chain are required to modify the circuit for the scan BIST, so that the design is very simple.

Resonance Type Acoustic Emission Signal Analyzing Method for the failure detection of the composite materials (복합재료의 파손 감지를 위한 동조형 음향방출 신호분석 기법)

  • Lee, Chang-Hun;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.30-36
    • /
    • 2004
  • As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the study on the non-destructive testing methods of the composite materials has become an important research area for improving their reliability and safety. In this paper, the AE signal analyzer with the resonance circuit to extract the specified frequency of the acoustic emission signal were designed and fabricated. The noise levels of the fabricated AE signal analyzer by the disturbance such as impact or mechanical vibration had a very small value comparable to those of the conventional AE signal analyzer. Also, the fabricated AE signal analyzer was proved to have about the same crack detection capabilities with the conventional AE signal analyzer under the static and dynamic tensile tests of the composite materials.

Crystallographic Effects of Anode on the Mechanical Properties of Electrochemically Deposited Copper Films (아노드의 결정성에 따른 전기도금 구리박막의 기계적 특성 연구)

  • Kang, Byung-Hak;Park, Jieun;Park, Kangju;Yoo, Dayoung;Lee, Dajeong;Lee, Dongyun
    • Korean Journal of Materials Research
    • /
    • v.26 no.12
    • /
    • pp.714-720
    • /
    • 2016
  • We performed this study to understand the effect of a single-crystalline anode on the mechanical properties of as-deposited films during electrochemical deposition. We used a (111) single- crystalline Cu plate as an anode, and Si substrates with Cr/Au conductive seed layers were prepared for the cathode. Electrodeposition was performed with a standard 3-electrode system in copper sulfate electrolyte. Interestingly, the grain boundaries of the as-deposited Cu thin films using single-crystalline Cu anode were not distinct; this is in contrast to the easily recognizable grain boundaries of the Cu thin films that were formed using a poly-crystalline Cu anode. Tensile testing was performed to obtain the mechanical properties of the Cu thin films. Ultimate tensile strength and elongation to failure of the Cu thin films fabricated using the (111) single-crystalline Cu anode were found to have increased by approximately 52 % and 37 %, respectively, compared with those values of the Cu thin films fabricated using apoly-crystalline Cu anode. We applied ultrasonic irradiation during electrodeposition to disturb the uniform stream; we then observed no single-crystalline anode effect. Consequently, it is presumed that the single-crystalline Cu anode can induce a directional/uniform stream of ions in the electrolyte that can create films with smeared grain boundaries, which boundaries strongly affect the mechanical properties of the electrodeposited Cu films.

Design of 10-Gb/s Adaptive Decision Feedback Equalizer with On-Chip Eye-Opening Monitoring (온 칩 아이 오프닝 모니터링을 탑재한 10Gb/s 적응형 Decision Feedback Equalizer 설계)

  • Seong, Chang-Kyung;Rhim, Jin-Soo;Choi, Woo-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.1
    • /
    • pp.31-38
    • /
    • 2011
  • With the increasing demand for high-speed transmission systems, adaptive equalizers have been widely used in receivers to overcome the limited bandwidth of channels. In order to reduce the cost for testing high-speed receiver chips, on-chip eye-opening monitoring (EOM) technique which measures the eye-opening of data waveform inside the chip can be employed. In this paper, a 10-Gb/s adaptive 2-tap look-ahead decision feedback equalizer (DFE) with EOM function is proposed. The proposed EOM circuit can be applied to look-ahead DFEs while existing EOM techniques cannot. The magnitudes of the post-cursors are measured by monitoring the eye of received signal, and coefficients of DFE are calculated using them by proposed adaptation algorithm. The circuit designed in 90nm CMOS technology and the algorithm are verified with post-layout simulation. The DFE core occupies $110{\times}95{\mu}m^2$ and consumes 11mW in 1.2V supply voltage.

A design of Space Compactor for low overhead in Built-In Self-Test (내장 자체 테스트의 low overhead를 위한 공간 압축기 설계)

  • Jung, Jun-Mo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.9
    • /
    • pp.2378-2387
    • /
    • 1998
  • This thesis proposes a design algorithm of an efficient space response compactor for Built-In Self-Testing of VLSI circuits. The proposed design algorithm of space compactors can be applied independently from the structure of Circuit Cnder Test. There are high hardware overhead cost in conventional space response compactors and the fault coverage is reduced by aliasing which maps faulty circuit's response to fault-free one. However, the proposed method designs space response compactors with reduced hardware overheads and does not reduce the fault coverage comparing to conventional method. Also, the proposed method can be extended to general N -input logic gate and design the most efficient space response L'Ompactors according to the characteristies of output sequence from CUT. The prolxlsed design algorithm is implemented by C language on a SUN SPARC Workstation, and some experiment results of the simulation applied to ISCAS'85 benchmark circuits with pseudo random patterns generated bv LFSR( Linear Feedback Shift Register) show the efficiency and validity of the proposed design algorithm.

  • PDF

Direct Action of Genistein on the Hypothalamic Neuronal Circuits in Female Rats

  • Lee, Woo-Cheol;Lee, Sung-Ho
    • Development and Reproduction
    • /
    • v.14 no.1
    • /
    • pp.35-41
    • /
    • 2010
  • Mammalian reproduction is regulated by a feedback circuit of the key reproductive hormones such as GnRH, gonadotropin and sex steroids on the hypothalamic-pituitary-gonadal axis. In particular, the onset of female puberty is triggered by gain of a pulsatile pattern and increment of GnRH secretion from hypothalamus. Previous studies including our own clearly demonstrated that genistein (GS), a phytoestrogenic isoflavone, altered the timing of puberty onset in female rats. However, the brain-specific actions of GS in female rats has not been explored yet. The present study was performed to examine the changes in the activities of GnRH neurons and their neural circuits by GS in female rats. Concerning the drug delivery route, intracerebroventricular (ICV) injection technique was employed to eliminate the unwanted actions on the extrabrain tissues which can be occurred if the testing drug is systemically administered. Adult female rats (PND 100, 210-230 g BW) were anaesthetized, treated with single dose of GS ($3.4{\mu}g$/animal), and sacrificed at 3 hrs post-injection. To determine the transcriptional changes of reproductive hormone-related genes in hypothalamus, total RNAs were extracted and applied to the semi-quantitative reverse transcription polymerase chain reaction (RT-PCR). ICV infusion of GS significantly raised the transcriptional activities of enhanced at puberty1 (EAP-1, p<0.05), glutamic acid decarboxylase (GAD67, p<0.01) which are known to modulate GnRH secretion in the hypothalamus. However, GS infusion could not change the mRNA level of nitric oxide synthase 2 (NOS-2). GS administration significantly increased the mRNA levels of KiSS-1 (p<0.001), GPR54 (p<0.001), and GnRH (p<0.01) in the hypothalami, but decreased the mRNA levels of LH-$\beta$ (p<0.01) and FSH-$\beta$ (p<0.05) in the pituitaries. Taken together, the present study indicated that the acute exposure to GS could directly activate the hypothalamic GnRH modulating system, suggesting the GS's disrupting effects such as the early onset of puberty in immature female rats might be derived from premature activation of key reproduction related genes in hypothalamus-pituitary neuroendocrine circuit.