• Title/Summary/Keyword: Circuit protection

Search Result 633, Processing Time 0.033 seconds

Development of the Internet-Based Educational Software Package for the Design and Virtual Experiment of the Digital Logic Circuits (디지탈 논리회로 설계 및 모의 실험 실습을 위한 인터넷 기반 교육용 소프트웨어 패키지 개발)

  • Ki Jang-Geun;Ho Won
    • Journal of Engineering Education Research
    • /
    • v.2 no.1
    • /
    • pp.10-16
    • /
    • 1999
  • In this paper, we developed the internet-based educational software package (DVLab) for design and virtual experiment of the digital logic circuits. The DVLab consists of the LogicSim module for design and simulation of digital combinational/sequantial logic circuits, micro-controller application circuits and the BreadBoard module for virtual experiment and the Theory module for lecture and the Report/ReportChecker module and some other utility modules. All developed modules can be run as application programs as well as applets in the Internet. The LogicSim and the BreadBoard support real time clock function, output verification function on the designed circuits, trace function of logic values, copy-protection function of designed circuits and provide various devices including logic gates, TTLs, LED, buzzer, and micro-controller. The educational model of digital logic circuit design and experiment using the DVLab is also presented in this paper.

  • PDF

An Effective Installation Method of lightning Protective Devices for Information and Communication Facilities (정보통신설비용 뇌서지 보호장치의 효과적인 설치기법)

  • 이복희;이동문;강성만;엄주홍;이승칠
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.90-96
    • /
    • 2002
  • The AC power lines and signal lines of info-communication networks are muted on overhead poles and are exposed to lightning strikes. Due to the potential difference between groundings of the AC power lines and telecommunication lines, the electronic equipments connected to the telecommunication lines can easily be damaged by lightning surges. In this work, in order to develop the reliable ways to protect information and communication facilities from lightning surges, the reliability and performance of surge protective devices were experimentally investigated in actual-sized test circuit. The operation behaviors of surge protective devices against lightning surges from the AC power lines and telecommunication lines and the coordination effects of SPD installation method were evaluated. As a consequence, it was confirmed that the bypass arrester and common grounding system is very effective.

The Analysis of Quench Protection System through Thermo-Electrodynamics of Resistive Transition in SC Magnet (초전도자석내의 국부적 상변이에 대한 열적.전기역학적 해석 및 퀜치보호시스템의 설계 및 특성해석)

  • Chu, Y.;Bae, J.H.;Kim, H.M.;Jang, M.H.;Joo, M.S.;Ko, T.K.;Kim, K.M.;Jeong, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.86-88
    • /
    • 1997
  • The detection of the normal zones in the coil winding and the initiation of the proper dump sequence have been one of the most important areas in the superconducting magnet technology. In this paper, the process to derive optimal dump sequence has been investigated through quench simulation and analysis of magnetically coupled superconducting magnet system. The magnet terminal voltage and maximum temperature rise in the quench initiated point are calculated with respect to various input variables such as operation current, dump resistance, etc. The experimental system is comprised of sc solenoidal coil, data aquisition device, external circuit breakers and dump resistor. The quench behavior of the magnet(e.g., temperature profile and the voltage signal) was measured. From this results, theoretical predictions were found to coincide with the experimental observations.

  • PDF

Heat load characteristic analysis of conduction cooled 10kJ HTS SMES (전도 냉각형 10kJ 고온 초전도 에너지 저장장치의 열 부하 특성 해석)

  • Kim, Kwang-Min;Kim, A-Rong;Kim, Jin-Geun;Park, Hae-Yong;Park, Min-Won;Yu, In-Keun;Kim, Seok-Ho;Sim, Ki-Deok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2219_2220
    • /
    • 2009
  • The characteristics of the Superconducting Magnetic Energy Storage (SMES) system are faster response, longer life time, more economical, and environment friendly than other Uninterruptible Power Supply (UPS) using battery. Fast charge and discharge time of SMES system can provide powerful performance of improving power quality in the grid. In order to demonstrate the effectiveness of SMES, the authors make a 10kJ SMES system for connection with RTDS (Real Time Digital Simulator). Because the characteristics of superconducting magnet are very important in SMES system, the necessary items such as thermal characteristic, mechanical stress and protection circuit should be considered. In this paper, the authors experimented thermal characteristics of the 10kJ SMES system. The experiment was accomplished using a simulation coils made of aluminium. It has same dimension of the 10kJ class HTS SMES coil. The coil was cooled with GM (Gifford -McMahon) cryocooler through the OFHC (Oxgen Free High thermal Conductivity) conduction bar. The test results of cool down and heat loads characteristics of the simulation coils are described in detail.

  • PDF

Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line (22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

Application of SFCL on Bus Tie for Parallel Operation of Power Main Transformers in a Fuel Cell Power Systems

  • Chai, Hui-Seok;Kang, Byoung-Wook;Kim, Jin-Seok;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.6
    • /
    • pp.2256-2261
    • /
    • 2015
  • In the power plant using high temperature fuel cells such as Molten Carbonate Fuel Cell(MCFC), and Solid Oxide Fuel Cell(SOFC), the generated electric power per area of power generation facilities is much higher than any other renewable energy sources. - High temperature fuel cell systems are capable of operating at MW rated power output. - It also has a feature that is short for length of the line for connecting the interior of the generation facilities. In normal condition, these points are advantages for voltage drops or power losses. However, in abnormal condition such as fault occurrence in electrical system, the fault currents are increased, because of the small impedance of the short length of power cable. Commonly, to minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we divided the power plant configuration to several banks for parallel operation. However, when a fault occurs in the parallel operation system of power main transformer, the fault currents might exceed the interruption capacity of protective devices. In fact, although the internal voltage level of the fuel cell power plant is the voltage level of distribution systems, we should install the circuit breakers for transmission systems due to fault current. To resolve these problems, the SFCL has been studied as one of the noticeable devices. Therefore, we analyzed the effect of application of the SFCL on bus tie in a fuel cell power plants system using PSCAD/EMTDC.

Security Technique using SSH Tunneling for CCTV Remote Access (SSH 터널링을 이용한 CCTV 원격접속 보안기법)

  • HWANG, GIJIN;PARK, JAEPYO;YANG, SEUNGMIN
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.148-154
    • /
    • 2016
  • Video security has recently emerged as an important issue owing to CCTV video image spill accidents over the Internet. KISA recommends the use of encryption protocols for remote access through its guidelines for CCTV personal video information protection. But still, many products do not adhere to the guidelines, and those products are easily exposed to security threats, such as hacking. To solve these security vulnerabilities, this paper proposes a CCTV system that connects from remote locations, and is implemented by using secure shell (SSH) tunneling techniques. The system enhances security by transmitting encrypted data by using SSH. By using the tunneling technique, it also solves the problem of not being able to access a CCTV recorder located inside a firewall. For evaluation of the system, this paper compares various CCTV remote access schemes and security. Experimental results on the effectiveness of the system show it is possible to obtain remote access without a significant difference in transmission quality and time. Applying the method proposed in this paper, you can configure a system secure from the threats of hacking.

The Design of CMOS-based High Speed-Low Power BiCMOS LVDS Transmitter (CMOS공정 기반의 고속-저 전압 BiCMOS LVDS 구동기 설계)

  • Koo, Yong-Seo;Lee, Jae-Hyun
    • Journal of IKEEE
    • /
    • v.11 no.1 s.20
    • /
    • pp.69-76
    • /
    • 2007
  • This paper presents the design of LVDS (Low-Voltage-Differential-Signaling) transmitter for Gb/s-per-pin operation. The proposed LVDS transmitter is designed using BiCMOS technology, which can be compatible with CMOS technology. To reduce chip area and enhance the robustness of LVDS transmitter, the MOS switches of transmitter are replaced with lateral bipolar transistor. The common emitter current gain($\beta$) of designed bipolar transistor is 20 and the cell size of LVDS transmitter is $0.01mm^2$. Also the proposed LVDS driver is operated at 1.8V and the maximum data rate is 2.8Gb/s approximately In addition, a novel ESD protection circuit is designed to protect the ESD phenomenon. This structure has low latch-up phenomenon by using turn on/off character of P-channel MOSFET and low triggering voltage by N-channel MOSFET in the SCR structure. The triggering voltage and holding voltage are simulated to 2.2V, 1.1V respectively.

  • PDF

Design Technology of the Wideband Power Amplifier for Electromagnetic Susceptibility Measurement (EMS 측정용 광대역 전력 증폭기 설계기술에 관한 연구)

  • 조광윤;류근관;홍의석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8B
    • /
    • pp.1464-1471
    • /
    • 1999
  • A wide-band high power amplifier to use for radiated electromagnetic field immunity testing of EMS(Electromagnetic Susceptibility) standards has to meet IEC1000-4-3 specification in the frequency bandwidth of 80MHz to 1000MHz. The power amplifier to be described in this paper consists of driving and power stages with wide-band matched circuits by estimated impedances. The mismatching protection circuit is inserted in it to prevent from damage of power device when the output port of power amplifier is opened or shorted by user's mistake. The characteristics of the power amplifier are obtained output power over 100watts, gain over 40dB and flatness of $\pm$0.3dB in the frequency range of 80 ~300MHz. The harmonics suppression characteristics is measured over 20dBc. This wide-band high power amplifier can be useful fur radiated electromagnetic field immunity testing of IEC 1000-4-3 standard.

  • PDF

Development of Fully Integrated Broadband MMIC Chip Set Employing CSP(Chip Size Package) for K/Ka Band Applications (CSP(Chip Size Package)를 이용한 완전집적화 K/Ka 밴드 광대역 MMIC Chip Set 개발)

  • Yun Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.102-112
    • /
    • 2005
  • In this work, we developed fully integrated broadband MMIC chip set employing CSP(Chip Size Package) for K/Ka band applications. By utilizing an ACF for the RF-CSP, the fabrication process for the packaged amplifier MMIC could be simplified and made cost effective. $STO(SrTi_{3})$ capacitors were employed to integrate the DC biasing components on the MMIC, and LC parallel circuits were employed for DC feed and ESD protection. A pre-matching technique and RC parallel circuit were used to achieve a broadband matching and good stability fer the amplifier MMIC in K/Ka band. The amplifier CSP MMIC exhibited good RF performance over a wide frequency range in K/Ka band. This work is the first report of a fully integrated CSP amplifier MMIC successfully operating in the K/Ka band.