A New Approach for Built-in Self-Test of 4.5 to 5.5 GHz Low-Noise Amplifiers

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • ETRI Journal
    • /
    • 제28권3호
    • /
    • pp.355-363
    • /
    • 2006
  • This paper presents a low-cost RF parameter estimation technique using a new RF built-in self-test (BIST) circuit and efficient DC measurement for 4.5 to 5.5 GHz low noise amplifiers (LNAs). The BIST circuit measures gain, noise figure, input impedance, and input return loss for an LNA. The BIST circuit is designed using $0.18\;{\mu}m$ SiGe technology. The test technique utilizes input impedance matching and output DC voltage measurements. The technique is simple and inexpensive.

  • PDF

압전 션트를 이용한 패널의 다중 모드 소음 저감에 관한 연구 (Multi-mode noise reduction of using piezoelectric shunt damping smart panels)

  • Kim, Joon-Hyoung;Kim, Jaehwan
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.327.2-327
    • /
    • 2002
  • In this paper, the transmitted noise reduction of smart panels of which passive piezoelectric shunt damping is used, is experimentally studied. Shunt damping experiments are based on the measured electrical impedance model. A passive shunt circuit composed of inductor, and load resistor is devised to dissipate the maximum energy into the joule heat energy For multi mode shunt damping, the shunt circuit is redesigned by adding a blocking circuit. (omitted)

  • PDF

낮은 입력 정재파비와 잡음을 갖는 수동 및 능동 바이어스를 사용한 저잡음증폭기에 관한 연구 (LNA Design Uses Active and Passive Biasing Circuit to Achieve Simultaneous Low Input VSWR and Low Noise)

  • 전중성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1263-1268
    • /
    • 2008
  • In this paper, the low noise power amplifier for GaAs FET ATF-10136 is designed and fabricated with active bias circuit and self bias circuit. To supply most suitable voltage and current, active bias circuit is designed. Active biasing offers the advantage that variations in the pinch-off voltage($V_p$) and saturated drain current($I_{DSS}$) will not necessitate a change in either the source or drain resistor value for a given bias condition. The active bias network automatically sets a gate-source voltage($V_{gs}$) for the desired drain voltage and drain current. Using resistive decoupling circuits, a signal at low frequency is dissipated by a resistor. This design method increases the stability of the LNA, suitable for input stage matching and gate source bias. The LNA is fabricated on FR-4 substrate with active and self bias circuit, and integrated in aluminum housing. As a results, the characteristics of the active and self bias circuit LNA implemented more than 13 dB and 14 dB in gain, lower than 1 dB and 1.1 dB in noise figure, 1.7 and 1.8 input VSWR at normalized frequency $1.4{\sim}1.6$, respectively.

Projector 회로 소음 및 진동 저감의 실험적 연구 (An Experimental Study on the Noise and Vibration reduction of Projector Driving Board)

  • 최영수;송근영;이종권;오홍렬;이승규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.135-140
    • /
    • 2013
  • This paper deals with noise reduction on a light source driving board in a projector. We analyze causes of noise/vibration in the circuit with the present increasing use of LD and LED driving boards. The main source of noise is the MLCC in the driving board. Our aim is to investigate how the mechanical arrangement of the circuit elements affects noise reduction. The result of our experiment shows that noise can be reduced by symmetrical arrangement and slots in PCB. This result is expected to facilitate a variety of applications for manufactures without a need to change circuit elements.

  • PDF

저잡음 증폭기를 위한 새로운 구조의 검사용 설계회로 (A New Design-for-Testability Circuit for Low Noise Amplifiers)

  • 류지열;노석호
    • 대한전자공학회논문지TC
    • /
    • 제43권3호
    • /
    • pp.68-77
    • /
    • 2006
  • 본 논문에서는 4.5-5.5GHz 저잡음 증폭기 (low noise amplifiers, LNAs)를 위한 새로운 구조의 검사용 설계(Design-for-Testability, DfT) 회로를 제안한다. 이러한 검사용 설계회로는 고가의 장비를 사용하지 알고도 저잡음 증폭기의 전압 이득, 잡음 지수, 입력 임피던스, 입력 반사 손실 및 출력 신호대 잡음 전력비를 측정한다. 검사용 설계회로는 $0.18{\mu}m$ SiGe 공정을 이용하여 설계되었으며, 입력 임피던스 정합과 직류 출력 전압 측정을 이용한다. 이러한 회로를 이용한 회로 검사 기술은 검사 방법이 간단하고 검사하는데 드는 비용이 저렴하다.

기준신호 보상회로를 이용한 더블 샘플링 방식의 비냉각형 볼로미터 검출회로 설계에 관한 연구 (A Study on Double Sampling Design of CMOS ROIC for Uncooled Bolometer Infrared Sensor using Reference Signal Compensation Circuit)

  • 배영석;정은식;오주현;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제23권2호
    • /
    • pp.89-92
    • /
    • 2010
  • A bolometer sensor used in an infrared thermal imaging system has many advantages on the process because it does not need a separate cooling system and its manufacturing is easy. However the sensitivity of the bolometer is low and the fixed pattern noise(FPN) is large, because the bolometer sensor is made by micro electro mechanical systems (MEMS). These problems can be fixed-by using the high performance readout integrated circuit(ROIC) with noise reduction techniques. In this paper, we propose differential delta sampling circuit to remove the mismatch noise of ROIC itself, the FPN of the bolometer. And for reduction of FPN noise, the reference signal compensation circuit which compensate the reference signal by using on-resistance of MOS transistor was proposed.

Audio 회로의 잡음해석과 시뮬레이숀 (Noise analysis and simulation of the audio circuits)

  • 차균현;이근철
    • 전기의세계
    • /
    • 제29권12호
    • /
    • pp.798-803
    • /
    • 1980
  • A computer program for noise analysis of the audio circuit is developed. The application of the program to the equalizer, low frequency amplifier of radio circuit and cascaded amplifier show good results. The general noise analysis method for cascade operational amplifier is presented. The noise spectral power density is calculated for a resonator active filter.

  • PDF

압전션트 댐핑을 이용한 지능패널의 다중 모드 소음 저감 (Multi-mode Noise Reduction of Smart Panels Using Piezoelectric Shunt Damping)

  • 김준형;김재환
    • 한국소음진동공학회논문집
    • /
    • 제13권4호
    • /
    • pp.300-307
    • /
    • 2003
  • This paper presents the multi-mode noise reduction of smart panels of which passive piezoelectric shunt damping is introduced. For the piezoelectric shunt damping, a passive shunt circuit composed of inductors and a load resistor is connected to the piezoelectric patch mounted on the panel structure. An electrical impedance model is introduced for the system based on the measured electrical impedance, and the criteria for maximum energy dissipation at the shunt circuit is used to find the optimal shunt parameters. For multi-mode shunt damping, the shunt circuit is modified by the introduction of a block circuit. Also the optimal location of the piezoelectric patch is studied by finite element analysis in order to cause the maximum admittance from the patch for each mode of the structure. An acoustic test is performed for the panels and a remarkable noise reduction is obtained in multiple modes of the panel structure.

새로운 능동EMI필터의 결합회로에 관한 연구 (A Study on the Combining Circuit of New Active EMI Filter)

  • 최민환;신동석;이동호;박종연
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.78-89
    • /
    • 2015
  • Conventional EMI filters have tried to use an active EMI filter as a series by the series connection of two EMI filters for CM and DM noise. However, the proposed filter is formed into one circuit by using the active EMI filter which is able to filter CM and DM noise components together. As a result, the active EMI filter showed the outstanding quality in mass and volume under 50% and electric characteristics have been compared to the passive EMI filter in approximately 150kHz~10MHz. Furthermore, the proposed circuit has simple circuit components by comparing with the series EMI filters, and electrical characteristics are similar. The noise have been attenuated to maximum 20dBuV.

자동 감마 증류탑 검사 장치를 위한 방사선 계측장치 설계 (Design of radiation detection circuit for gamma column scanning)

  • 김종범;정성희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.612-615
    • /
    • 2003
  • In this paper, a design of radiation detector for gamma column scanner is introduced. Distillation column is important unit in Petro-chemical industries, and its on-line diagnose is very important. To get density profile measured by the radiation transmitted through column is well method for on-line diagnose as gamma scanning. For this purpose radiation detection circuit, radiation source and mechanical system for moving source and detector are required. Conventional radiation detection circuit for this application is sensitive to electric noise because of interface between the radiation circuit and the controller for mechanical system. The radiation detection system introduced here is using loop coil instead of slip ring to remove contact noise. Radiation detection system designed here for gamma scanning consist of BGO detector, high voltage circuit, PHA circuit and FSK modem. The BGO detector is used as radiation sensor, high voltage circuit and peak height analysis circuit is essential to process the signal generated from BGO detector. Micro controller convert measured data into ASCII data. FSK modem transmit ASCII data. Transmitted ASCH data is picked up in antenna coil and processed for combined function with mechanical system. This method gives good result by isolating the controlling circuit of mechanical system from radiation detecting circuit which is sensitive to noise.

  • PDF