옥내 배전선로용 아크차단기 개발에 관한 연구 (A Study on Development of Arc Fault Circuit Interrupter Used in House Distribution Line)

  • 곽동걸;최정규;박영직;김진환;손재현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.546-547
    • /
    • 2013
  • This paper proposes an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. It perceives a voltage instantaneously at the time of voltage drop. and occurrence. It is an AFCI of the new concept which operates with high reliability. The primary reason of electric fire is arc and spark. It prevents an electric fire or an electric leakage accident with quick responsiveness. Earth Leakage Circuit Breaker(ELB), Molded_case Circuit Breaker (MCCB) or Residual Current Protective Device(RCD) can not cut off electric arc or spark to be a major factor of electrical fire. This theory will be able to intercept an arc or a spark. which occurrence with periodic. Consequently It raises a reliability and validates a practicality of RCD.

  • PDF

구동코일의 단락환 형상변경에 따른 아크전류와 자속간의 위상차 특성 (Characteristics of the Phase Difference Between Arc-current and Magnetic Field Due to the Shape Variation of the Short-Circuit Ring of the Driving Coil)

  • 정진교;박경엽;신영준;조현호;최승현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.34-36
    • /
    • 1998
  • In these days the hybrid interrupters are widely used for medium voltage class circuit breakers. In the design of the hybrid interrupter, the shape of the short-circuit ring is one of the most important design parameters. Recently the investigation into the phase difference between arc current and magnetic field due to the shape variation of the short circuit ring has been conducted. In this paper, the results of eddy current analyses in the hybrid interrupter and test result are presented.

  • PDF

800kV 모델차단부의 극간 절연회복특성 -I. 가동주접점과 가동아크접점간 이격거리의 변화에 대한 영향분석- (Dielectric Recovery Characteristics between Poles of 800kV Model Interrupter -I. Effects or separation between Moving Main Contact and Moving Arcing Contact-)

  • 신영준;박경엽;장기찬;송기동;정진교;송원표;강종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.270-273
    • /
    • 1994
  • The capacitive current breaking capability as well as the short circuit current breaking capability is a very important factor in the performance of a circuit breaker. The dielectric recovery capability between poles should be considered in the desist of a circuit breaker because approximately two times of the maximum power system voltage might be applied between poles after the capacitive current be interrupted. The electric field and flow field analyses were utilized in the calculation of dielectric recovery characteristics between poles of 800kV model interrupter. The results show that the separation between moving main contact and moving arcing contact will affect to decrease significantly the electric field strength of a moving arcing contact and an insulation cover, to increase slightly the electric field strength of a fixed arcing contact and to decrease consequently the dielectric recovery capability between poles of the interrupter.

  • PDF

36kV급 진공차단기에 적용 가능한 PMA(영구자석형 조작기) 연구 및 동작특성 해석 (Research and Analysis of Dynamic Behavior Permanent Magnetic Actuator applicable to 38kV Vacuum Circuit Breaker)

  • 강종호;신동규;배채윤;정현교
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.18-20
    • /
    • 2004
  • This paper formulates the principle of the permanent magnetic actuator (PMA) and its dynamic characteristic calculation applicable to High Voltage Vacuum Interrupter (38kV/31.5kA). The new type of PMA is need to apply to High Voltage Vacuum Interrupter for large stroke length and contact force at interrupter. Consequently this paper describes the ideal matching of the new type of PMA mechanism with the characteristics required to operate successfully, reliably and efficiently a High Voltage Vacuum Interrupter.

  • PDF

아크사고 발생 시 전압 왜형파를 이용한 아크차단기 개발 (Development of Arc Fault Circuit Interrupter Using the Distorted Voltage Wave in Electric Arc Faults)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.876-880
    • /
    • 2013
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The principal factor of the fire is electric arc or spark accompanied with such electric faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30[ms] (KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problems, this paper studies on an arc fault circuit interrupter (AFCI) using the distorted voltage wave in electric arc faults. The proposed voltage sensing type AFCI is an electrical fire prevention apparatus of new conception that operates a circuit breaker with sensing the instantaneous voltage drop of line voltage at electrical faults occurrence. The proposed AFCI is composed of control circuit topology using some semiconductor switching devices. Some experimental tests of the proposed AFCI confirm practicality and the validity of the analytical results.

AFCI용 온도보상회로의 ASIC화에 관한 연구 (A Study on the ASIC of Temperature Compensation Circuit for AFCI)

  • 양승국;신명호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.293-296
    • /
    • 2009
  • 2002부터 미국에서 전기화재 보호를 위하여 AFCI(Arc Fault Circuit Interrupter)사용이 의무화되었으며 중성선의 선로저항을 이용하여 아크를 검출하는 방식의 AFCI의 경우 중성선 선로저항의 저항온도계수에 대한 온도보상이 필요하다. 이러한 온도보상회로를 주문형반도체(ASIC)에서 구현하는 방안을 제시하고 ARC 신호에 대하여 시뮬레이션하여 전기적 특성 및 온도특성을 검증하였다.

  • PDF

Experimental Investigations Into Low Current Steady State Arcs In A Dual-Airflow Model Interrupter

  • Shin, Young-June;Cho, Yun-Ok;Kim, Jin-Gi;Lee, Jeong-Rim
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.961-965
    • /
    • 1992
  • It is well-known that shock waves frequently occur inside the nozzle of the interrupter, and that they play important roles in the arc interruption. A model interrupter with two-dimensional dual-airflow nozzles was used for this experiment. The arc was ignited with 1.4 mil copper wire stretched between the electrodes which were spaced out 56 mm. The arc current of 60 to 230 A was achieved by adjusting the external resistance from 5.5 to 1.6 ohms. The arc tests have been conducted for investigating the air arc characteristics, and the effects of shock waves and nozzle pressure ratios on the arc voltage, the arc resistance, the arc power, and average electric field. The results of these tests have been analyzed to provide insights into the arc characteristics for gas circuit breakers. The average electric field is represented by the function of the arc current to show the negative E-I characteristic explicitly. The effects of shock waves and nozzle pressure ratios are shown to be significant for a circuit breaker performance.

  • PDF

진공인터럽터용 다극 종자계전극의 자계분포 특성 (The Magnetic Field Characteristics of Multipolar Axial Magnetic Field type Electrodes for Vacuum Interrupter)

  • 김성일;박홍태;안희일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.92-94
    • /
    • 1999
  • This paper describes axial magnetic field characteristics of multipolar axial magnetic field type electrodes for vacuum interrupter used in vacuum circuit breaker. It was distinguished that axial magnetic field distribution in consideration of eddy current effect between electrodes by finite element method. Throughout experiment of magnetic field measurement, confirmed validity of numericla analysis.

  • PDF

누전차단기의 설계와 제작 (Ground fault circuit interrupter design)

  • 설승기
    • 전기의세계
    • /
    • 제29권5호
    • /
    • pp.303-311
    • /
    • 1980
  • The hazards of electrical shock are well known, but the conventional ground fault circuit breakers did not provide the statis factory safety for human body. Thus this paper considers the standards of performance that they must meet, and describes the new tripping mechanism the operations and the improvements. The experiment at new G.F.C.I. indicates maximum tripping time 25msec minimum sensitive leakage current 25mA and maximum nonaperation leakage current 15mA.

  • PDF

진공차단부 과계해석 및 전자력 계산 (Magnetic Field Analysis and Magnetic Force Calculation of Vacuum Interrupter)

  • 김익모;김진수;최명준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.186-188
    • /
    • 2001
  • Recently, the vacuum interrupters have been most widely used in medium voltage level. In the vacuum circuit breaker the most influential part is vacuum interrupter. By performing the precise electromagnetic analysis of the interrupter, we increase the capability of large current interruption. In this paper, diffuse arc and constricted arc are modeled to perform 3D electromagnetic analysis, and also flux distributions and electromagnetic force is calculated at the contacts' separation. It is expected these results will be used importantly in developing the new vacuum interrupters.

  • PDF