파퍼실린더 직경이 초고압 GCB의 열적 차단성능에 미치는 영향 (Influence of Diameter of Puffer Cylinder on Thermal Interruption Capability of EHV GCB)

  • 오연호;송기동;최영길;이병윤;박경엽;신영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.37-39
    • /
    • 1998
  • This paper presents the pressure-rise of the puffer cylinder in a model gas circuit breaker and the analyzed results of thermal interruption capability in SLF(short line fault) to the diameter of the puffer cylinder. This paper can be applied to the design of the EHV interrupter.

  • PDF

반사형 광센서를 사용한 저가형 SRM 구동시스템 (A Low Cost Drive System of Switched Reluctance Motor Using Reflective Type Photosensors)

  • 김세주;윤용호;정균하;원충연;김영렬
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.63-68
    • /
    • 2004
  • Since rotor position information is necessary to drive the SRM, absolute-encoder, resolver and incremental-encoder is used to detect a poor position. But, it is not desirable to use a high priced encoder and high efficient microprocessor under the condition of the simple driving system when precision control is not demanded. In this paper, Only using the reflective type 2 photosensors replace the conventional opto interrupter and slotted disk, which not only remove a slotted disk section but drive 3-phase 6/4 SRM bidirectionally. Moreover, as control circuit only is composed of common analog device economy is maximized.

  • PDF

영구자석형 차단기의 특성해석 및 설계 (Analysis of Dynamic characteristic and design of permanent magnetic actuator)

  • 서정호;김한균;주수원;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1040-1042
    • /
    • 2004
  • For past decade, medium voltage circuit breakers have used the spring-driven mechanical system for interrupting of electric power. However, these mechanisms have many disadvantages of high power consumption, mechanical control components and electrical switching ones for the coil current. Recently, the vacuum interrupter operated by permanent magnet actuator gives outlook on improved characteristic, higher reliability and cost price reduction as well as the feature of simple structure and few components. This paper deals with the dynamic characteristics of permanent magnet actuator used in the medium voltage distribution systems. Coupled finite element method is used to analysis the dynamic characteristics of permanent magnetic actuator and we compared with those of conventional ones

  • PDF

아크차단기의 필요성에 관한 연구 (Research on Necessity of Arc Fault Circuit Interrupter)

  • 박치현;배석명;임용배;김기현;최명일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2084-2085
    • /
    • 2007
  • 전력사용이 증가함에 따라 전기설비에 의한 전기화재 수가 늘어나고 있다. 통계에 따르면 전기화재가 화재원인 중 가장 많은 비중을 차지하고 있음을 알 수 있다. 그럼에도 불구하고 전기화재를 정확히 찾아낼 수 있는 조사기법이 개발되지 않고 있는 실정이다. 이 논문은 전기화재 원인과 아크차단기의 특성에 관하여 분석한다. 아크에 의한 위험을 수학적 분석을 이용한 전력계산을 통하여 분석하고 단락회로에 의한 위험성과 비교 한다. 또한 아크차단기와 기존의 누전차단기와 비교를 통하여 아크차단기의 필요성을 제기한다.

  • PDF

간단한 엔지니어링기법에 의한 이중유동형 노즐내의 저전류 정적 아크의 특성 비교 (Comparison of Characteristics of Steady State Low Current Arcs In Dual Flow Nozzles by Simplified Engineering Techniques)

  • 송기동;신영준;박경엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.627-630
    • /
    • 1993
  • The arc characteristics have influences on the current interruption phenomena in the regimes of low current as well as high current. It is very important to understand the arc characteristics for the initial design of a circuit breaker. This article describes the theoretical analysis of the arc characteristics by means of arc energy integral method when convection dominated low current arcs are produced in the dual-nozzle air and $SF_6$ gas flows of a model interrupter. The arc radius, average electric field strength and arc voltage have been investigated at the current range of 60 to 230 A and at the upstream pressure of 0.6 MPa in both air and SF6 gas. The results have been compared to show the difference of both gases and the trends similar to those of other investigations.

  • PDF

CFD-CAD 통합해석을 이용한 초고압 차단기 내부의 냉가스 유동해석 프로그램 개발 (Development of a CFD Program for Cold Gas Flow Analysis in a High Voltage Circuit Breaker Using CFD-CAD Integration)

  • 이종철;안희섭;오일성;최종웅
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권5호
    • /
    • pp.242-248
    • /
    • 2002
  • It is important to develop new effective technologies to increase the interruption capacity and to reduce the size of a UB(Gas Circuit Breakers). Major design parameters such as nozzle geometries and interrupting chamber dimensions affect the cooling of the arc and the breaking performance. But it is not easy to test real GCB model in practice as in theory. Therefore, a simulation tool based on a computational fluid dynamics(CFD) algorithm has been developed to facilitate an optimization of the interrupter. Special attention has been paid to the supersonic flow phenomena between contacts and the observation of hat-gas flow for estimating the breaking performance. However, there are many difficult problems in calculating the flow characteristics in a GCB such as shock wave and complex geometries, which may be either static or in relative motion. Although a number of mesh generation techniques are now available, the generation of meshes around complicated, multi-component geometries like a GCB is still a tedious and difficult task for the computational fluid dynamics. This paper presents the CFD program using CFB-CAD integration technique based on Cartesian cut-cell method, which could reduce researcher's efforts to generate the mesh and achieve the accurate representation of the geometry designed by a CAD tools.

인버터식 고효율 네온관용 변압기 (Inverter type High Efficency Neon Transformers for Neon Tubes)

  • 변재영;김윤호
    • 조명전기설비학회논문지
    • /
    • 제16권6호
    • /
    • pp.22-29
    • /
    • 2002
  • 무방향성 규소강판을 사용한 자기식 네온관용 변압기는 내구성이 좋은 반면에 용량에 따른 규소 강판의 무게가 무겁고 외형이 큰 관계로 네온관 설치 작업 시 상당히 불편한 점이 많다. 또한 네온관의 다양한 디스플레이 제어성면에서도 비합리적 이었다. 이를 개선하기 위한 방법으로 네온 트랜스포머의 전원장치 및 2차측 고압 출력부를 고속의 고주파 스위칭 파워 트랜지스터(MOSFET)를 이용하여 상용주파수 60[Hz]를 고속 스위칭 제어를 통하여 20[KHz]의 고주파로 변환시킨후, 네온관을 방전시키기 위한 고전압을 발생시키는 인버터식 네온관용 변압기를 구현하였다. 또한 네온관의 파손이나 누전으로 인한 화재나 인체 감전의 위험을 사전에 방지할 수 있는 보호회로 GFCI(Ground Fault Circuit Interrupter)를 제안 하였다.

Operational Characteristics of Flux-lock Type SFCL using Series Resonance

  • Lim, Sung-Hun;Han, Byoung-Sung;Choi, Hyo-Sang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권4호
    • /
    • pp.159-163
    • /
    • 2005
  • We analyzed the fault current limiting characteristics of a flux-lock type $high-T_c$ super­conducting fault current limiter (HTSC-FCL) using series resonance between capacitor for series resonance and magnetic field coil which was installed in coil 3. The capacitor for the series resonance in the flux-lock type HTSC-FCL was inserted in series with the magnetic field coil to apply enough magnetic field into HTSC element, which resulted in higher resistance of HTSC element. However, the impedance of the flux lock type HTSC-FCL has started to decrease since the current of coil 3 exceeded one of coil 2 after a fault accident. The decrease in the impedance of the FCL causes the line current to increase and, if continues, the capacitor for the series resonance to be destructed. To avoid this operation, the flux-lock type HTSC-FCL requires an additional device such as fault current interrupter or control circuit for magnetic field. From the experimental results, we investigated the parameter range where the operation as mentioned above for the designed flux-lock type HTSC-FCL using series resonance occurred.

아크이미지와 아크전압분석을 통한 Spiral Type 진공인터럽터 접점손상이 아크거동 및 차단성능에 미치는 영향분석

  • 김병철;김성태;최종웅;안길영;이종호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.344-344
    • /
    • 2011
  • 진공인터럽터는 진공차단기에서 실제 사고전류차단시 발생하는 아크소호 및 차단을 담당하는 매우 중요한 부분이다. 일반적으로 교류차단기는 일시적으로 에너지가 공급되지 않는 전류 영점에서 아크소호 및 전류차단이 이루어진다. 일반적으로 아크가 발생하는 전극분리시점에서 아크가 소호되는 전류영점까지의 시간을 아크지속시간(arcing time)이라고 한다. 일단 진공 인터럽터 내부의 접점이 분리됨과 동시에 아크가 발생하게되면 이때 진공인터럽터는 아크지속시간동안 고온의 아크에 의한 접점손상을 최소화하기 위해 아크의 거동을 적절히 제어하여 아크에너지를 접점표면상에 골고루 분산시켜야 한다. 현재 진공인터럽터에 사용되는 아크제어 방식에는 크게 횡자계 방식과 축자계 방식이 있다. 본 논문에서는 횡자계 방식 중 spiral type 접점을 사용하여 25 kA의 전류차단시험을 진행하면서 아크전압을 취득하는 동시에 아크이미지를 촬영하여 아크지속시간동안의 아크의 거동을 분석하였는데 특히 본 실험에서는 전체 아크지속시간동안의 아크상태천이과정이 가장 잘 관찰되는 비교적 긴 아크지속시간을 설정하여 실험을 진행하였으며 이때 접점손상이 아크거동 및 차단성능에 미치는 영향을 중점적으로 다루었다.

  • PDF

전기화재 징후 감지를 위한 아크전류 파형분석에 관한 연구 (A Study on Analysis of Arc Current Waveforms for Detection of Prognostics of Electrical Fires)

  • 황진권
    • 한국화재소방학회논문지
    • /
    • 제23권1호
    • /
    • pp.7-14
    • /
    • 2009
  • 전류 돌입형, 비선형 및 전류 단속형 부하들은 정상작동 상태에서 아크 발생의 경우와 유사한 전류파형을 갖는다. 이러한 부하들에서 아크 검출기법을 정확하게 구현하기 위하여서는 아크 유무에 따른 전류파형의 전형적인 특징을 찾을 필요가 있다. 본 논문에서는 UL 1699의 직렬과 병렬 아크 발생장치들로 이러한 부하들에 마크를 발생시키고 시간 및 주파수 영역에서 아크 전류파형을 분석한다. 아크 실험의 분석결과를 통하여 아크 전류파형의 전형적인 특징은 시간영역에서는 영점전류의 처짐 현상이고 주파수영역에서는 60Hz 고조파 성분을 제외한 전대역의 주파수에 걸쳐서 스펙트럼 크기가 증가되는 것임을 보인다. 비선형 및 전류 단속형 부하들에서 시간영역보다는 주파수영역의 아크 전류의 특징이 보다 명확히 나타남을 보인다. 본 논문에서 제시된 아크 전류파형의 특징들은 아크 차단기 개발을 위한 기반자료로 활용될 것으로 기대된다.