• Title/Summary/Keyword: Circuit Parameter

Search Result 689, Processing Time 0.031 seconds

Analysis of Chaotic Phenomena with Transmission line of Chua's Circuit (전송선로를 가진 Chua 회로에서의 카오스 현상 해석)

  • Ko, Jae-Ho;Bae, Young-Chul;Yim, Wha-Young
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.533-535
    • /
    • 1997
  • Chua's circuit is a simple electronic network which exhibits a variety of bifurcation and attractors. The circuit consists of two capacitors, an inductor, a linear resistor, and a nonlinear resistor. In this paper we analyze a circuit obtained by replacing the parallel LC resonator in the Chua's circuit by lossless transmission line. By using the method of characteristics of this circuit we show that various periodic motions and chaotic motions can the attained according to parameter variations. From Chua's circuit with a lossless transmission line, a variety of chaotic attractors which are similar to those of the normal Chua's circuit are observed.

  • PDF

An Electrical Characteristics Analysis of Electronic Blood Pressure Depressor (전자혈압강하기의 전기적 특성 분석)

  • Lee, K.S.;Suh, J.H.;Lee, J.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.83-89
    • /
    • 2006
  • Recently, the seriousness of high blood pressure was appeared as the most frequent disease of a the whole sickness in the world. However, the treatment of this disease is uncertain and produces an adverse reaction of a medicine therapy. Also, the patients are burdened with a fee for medical treatment. Therefore, in this paper, we studied effectively and financially to execute the treatment of high blood pressure using the Chinese medicine theorem that is recently arousing the great interest of the people. The main theories in this paper are blood vessel theory and acupuncture, respectively. Especially, the composed circuit systems are classified the blood pressure depressor part and the meridian points discrimination part, respectively. The blood pressure depressor part is composed generally of low-frequency generation circuit, charging-discharging circuit, and micro-computer circuit. Finally, this research have the advantage of discrimination parts such as regular voltage generating circuit, stimulus circuit, amplifying circuit, and alarm circuit.

  • PDF

High-Frequency Parameter Extraction of Insulating Transformer Using S-Parameter Measurement (S-파라메타를 이용한 절연 변압기의 고주파 파라메타 추출)

  • Kim, Sung-Jun;Ryu, Soo-Jung;Kim, Tae-Ho;Kim, Jong-Hyeon;Nah, Wan-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.3
    • /
    • pp.259-268
    • /
    • 2014
  • In this paper, we suggest a method of extracting circuit parameters of the insulating transformer using S-parameter measurement, especially in high frequency range. At 60 Hz, conventionally, no load test and short circuit test are used to extract the circuit parameters. In this paper S-parameters measured from VNA(Vector Network Analyzer) were used to extract the transformer parameters using data fitting method (optimization). The S-parameters from the equivalent circuit using the extracted parameters showed good agreement with those from measurement. Furthermore, the transformer secondary voltages from the equivalent circuit model also coincide quite exactly to the measured secondary voltages in sinusoidal forms. Finally we assert that the proposed method to extract the parameters for the insulating transformer using S-parameter is valid especially in high frequency.

A Study on Optimization of the Weil-Dobkes Synthetic Short-Circuit Tests (Weil-Dobke 합성단락시험로의 최적화 연구)

  • 김맹현;고희석
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.6
    • /
    • pp.287-292
    • /
    • 2001
  • This paper deals with the configuration, operating principles, systematic calculation method of parameter and optimization method of test circuit for parallel current injection method, series voltage injection method and hybrid synthetic test method as the method for performance test of circuit breaker with extra high interrupting capacity. The test method depicted above is applied to short-circuit making and breaking test (operating sequence :Os CdOs, Od-CdOs) and out-of-phase tests(operating sequence :Os, CdOs) for performance test of the newly-developed 420kV, 50kA and 800kV 50kV puffer-type gas circuit-breaker according to IEC 60056 and IEC 60427. The testing results, evaluation of equivalence for test and analyzed results are also presented in this paper.

  • PDF

Design and analysis tool for optimal interconnect structures (DATOIS) (최적회로 연결선 구조를 위한 설계 및 해석도구 (DATOIS))

  • 박종흠;김준희;김석윤
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.7
    • /
    • pp.20-29
    • /
    • 1998
  • As the packing density of ICs in recent submicron IC design increases, interconnects gain importance. Because interconnects directly affect on two major components of circuit performance, power dissipation and operating speed, circuit engineers are concerned with the optimal design of interconnects and the aid tool to design them. When circuit models of interconnects are given (including geometry and material information), the analysis process for the given structure is not an easy task, but conversely, it is much more difficult to design an interconnect structure with given circuit characteristics. This paper focuses on the latter process that has not been foucsed on much till now due to the complexity of the problem, and prsents a design aid tool(DATOIS) to synthesize interconnects. this tool stroes the circuit performance parameters for normalized interconnect geometries, and has two oeprational modes:analysis mode and synthesis mode. In the analysis mode, circuit performance parameters are obtained by searching the internal database for a given geometry and interpolates results if necessary . In thesynthesis mode, when a given circuit performance parameter satisfies a set of geometry condition in the database, those geometry structures are printed out.

  • PDF

Study on the parameter estimation of short-circuit generator (단락발전기 파라미터 추정에 대한 고찰)

  • Kim, Sun-Ho;Kim, Sun-Koo;Roh, Chang-Il;Kim, Won-Man;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.866-867
    • /
    • 2008
  • Among many tests to verify the characteristics of power system apparatus, the short circuit test is performed to verify the performance characteristics of the apparatus under the short-circuited power system. The verification of the short-circuit performance is inevitable for the reliability of power system and the safety of the operator around. The short circuit performance test requires the suitable power source and Korea Electrotechnology Research Institute has 4000 MVA, 500 MVA short circuit generators for the short circuit performance test. This paper will study on the parameters of short-circuit generator and the estimation of them.

  • PDF

Thickness-Vibration-Mode Piezoelectric Transformer for Power Converter

  • Su-Ho lee;Yoo, Ju-Hyun;Yoon, H.S.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.1 no.3
    • /
    • pp.1-5
    • /
    • 2000
  • This paper presents a new sort of multilayer piezoelectric ceramic transformer for switching regulation power supplies. This piezoelectric transformer operate in the second thickness resonant vibration mode. Accordingly its resonant frequency is higher than 1 NHz, Because output power is low if input and output part of transformer are consisted of single layer, this research suggests a new method, which is consisted of both input and output part of transformer have 2-layered piezoelectric ceramics, The size of transformer is 20 mm in width and length, and 1.4 mm in thickness, respectively, To design a high efficient switching circuit of the transformer, internal circuit parameters were measured and then weve calculated a parameter of inductor nd capacitor to design a driving circuit, Weve used a MISFET and its driver circuit modified a calp oscillator circuit as the primary switching circuit.

  • PDF

Prediction of EFT/B Signal Transfer Characteristics in Mobile Charging Circuit (모바일 충전회로에서 EFT/B 신호의 전달특성 예측에 대한 연구)

  • Song, SeungJae;Kim, Kwangho;Jo, Jeongmin;Lee, Seungbae;Kim, So-young;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.10
    • /
    • pp.895-906
    • /
    • 2015
  • This paper presents a methodology and a model that can analyze the high frequency transfer characteristics from socket in the AC power port to the 5 V DC output port in the mobile charging circuit. This is to predict the output signals coming from the IEC(International Electrotechnical Commission) Standard(IEC 61000-4-4), EFT/B(Electric Fast Transient and Burst) immunity test for mobile charging circuit. Since the mobile charging circuit is energized from the AC power socket from the power line, it is necessary to know the high frequency transfer characteristics with activated AC power line. A simple CDN(Coupling-Decoupling Network) is designed and manufactured for measuring S-parameters of mobile charging circuit with and without AC power line activated. The result shows that the S-parameters of the specific mobile charging circuits are almost the same, independent of AC power line activation. Consequently, the S-parameters without AC line could be used to predict the output response to the EFT/B signals, and it was shown that the proposed methodology predicts the output responses quite accurately, which proves the validness of the methodology presented in this paper.

RF Detecting Circuit Analysis by Using BLT Equation (BLT 방정식을 이용하 RF 검파 회로 해석)

  • Hwang, Se-Hoon;Park, Yoon-Mi;Jung, Hyun-Kyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.9
    • /
    • pp.1643-1647
    • /
    • 2007
  • Recently, there is a need for research concerning the technologies and precaution methods against electronic bomb assaults. There lays perplex constitution and much coupling phenomenon in this type of system, and thus requires much time and memory in order to translate the system with the existing translation methods. Applying the EMT (Electromagnetic Topology) would prove much more efficient. In this paper, EMT has been applied to the circuit-like micro system, previously employed in micro systems. Also, each section has been interpreted using the BLT (Baum, Liu, Tesche) equation using the EMT, then reconstructed, consequentially interpreting an entire system. In this paper, a simple circuit containing active and passive elements based on a CPW has been interpreted employing the BLT equation, and has been proven by experiment using the circuit simulation, a simulation officially recognized for its accuracy in interpreting small structures. The interpretation results have been presented by an S-parameter, and by comparing the interpretation results attained through the BLT equation and that from common simulation to that from experimentation, that the BLT equation turned out to be the most reliable interpretation method could be found.

Characteristics Analysis of ZVS-HB Type High Frequency Resonant Inverter According to the Variable Capacitance of the DC Voltage Source Separation Capacitor (직류 전원 분할용 커패시터의 용량 변화에 따른 ZVS-HB형 고주파 공진 인버터의 특성해석)

  • Mun, Chang-Su;Kim, Jong-Hae;Kim, Dong-Hui;O, Seung-Hun;Sim, Gwang-Yeol;Min, Byeong-Jae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.5
    • /
    • pp.352-357
    • /
    • 2000
  • This paper presents about an example of circuit design and characteristics of inverter according to the variable capacitance of the DC voltage source separation capacitor used in ZVS-HB type high frequency resonant inverter. The soft switching technology known as ZVS is used to reduce turn off loss at switching. In the event the capacitance of the DC voltage source separation capacitor is varied, the analysis of inverter circuit has generally described by using normalized parameter and operating characteristics have been evaluated in terms of switching frequency and parameters. According to the calculated characteristics value, a method of the circuit designs and operating characteristic of the inverter is also presented in this paper. In addition, this paper proves the validity of theoretical analysis through the experiment. This proposed inverter shows that it can be practically used in future as power source system for the lighting equipment of discharge lamp, DC-DC converter etc.

  • PDF