• 제목/요약/키워드: Chute

검색결과 47건 처리시간 0.025초

친환경 건축자재로서 황토마감재 개발을 위한 천연혼화재 비율설정에 관한 연구 (Determination of Ratios of Natural Ingredients for Loess(Hwangtoh) as Environmental-Friendly materials)

  • 이태구
    • KIEAE Journal
    • /
    • 제6권2호
    • /
    • pp.51-57
    • /
    • 2006
  • With people's awareness of environment-friendly buildings recently increasing, there is a need to develop environment-friendly construction materials to reduce indoorair pollution levels. Thus, efforts to develop loess finishing materials that can replace the finishing materials currently being used (e.g., gypsum boards and chemical products) are underway. An analysis of the characteristics of domestic loess products,however, revealed that the cracks on loess products can be lessened and their strength can be improved by adding chemical ingredients to them. Thus, this research sought to use 100% natural materials and to develop loess finishing materials. In the experiments that were conducted in this study, appropriate mixture ratios of loess and sand/silica sand were found, and cracks and contraction ratio changes in samples were analyzed by differentiating the ratios of natural ingredients, such as lime, fine jute threads, gypsum, and jute cuttings. Loess'particle size distribution was found to have a high correlation with loess decoration, and it was discovered that the mixture of lime and fine chute threads could improve the contraction ratio. Through this study, which made use of natural ingredients, environment-friendly construction materials that can exercise the original function of loess were developed.

환경에너지시설내 화격자식 소각로 수치해석 연구 (Numerical research for Gate Type Waste Incinerators In Environment energy facilities)

  • 김종윤;전용한
    • 대한안전경영과학회지
    • /
    • 제19권4호
    • /
    • pp.149-155
    • /
    • 2017
  • This study is analyzed combustion phenomena based on the environmental energy facility incinerator. It is assumed that combustible components of waste are composed of carbon and hydrogen, and the combustion process of fuel is by setting as multi-component / multistage reaction. As the combustion chamber is burned, the high temperature environment is achieved, also the heat transfer accompanied by the turbulent flow and the generation of NOx, a pollutant, are interpreted to predict the thermal and fluid characteristics and pollution emissions of the grate incinerator. As the result of internal flow analysis, the slow flow around the ash chute and the mixing effect due to the complicated turbulence around the combustion chamber were predicted to show excellent performance. It is shown to the internal average temperature was about $1024^{\circ}C$, around the about $1000^{\circ}C$ homogeneous temperature distribution. Due to the sudden temperature decrease in the boiler, the flue gas temperature at the outlet was estimated to be about $220^{\circ}C$.

AHP 기법에 의한 농업용 저수지의 상태평가 기준 설정 (Establishment of Condition Assessment Criteria in Agricultural Reservoirs by AHP)

  • 심재웅;이영학;이달원
    • 한국농공학회논문집
    • /
    • 제64권5호
    • /
    • pp.17-26
    • /
    • 2022
  • In this study, in order to establish the criteria for evaluation of importance by the type of facility specialized for agricultural reservoirs, an expert group consisting of a total of 167 members who were in management, or specialized in the fields of design, research, and diagnosis were organized, and the importance for facilities was set with application of the AHP technique. The importance of dam body, spillway, and intake structure composing a reservoir were set at 59%, 24%, and 17%, and the importance of dam crest, upstream slope, and downstream slope constituting a dam body was set at 32%, 31%, and 37%, respectively. In addition, the importance of approach channel, regulated channel, chute channel, and stilling basin consisting a spillway was set at 15%, 44%, 26%, and 15%, and the importance of inclined conduit and outlet conduit consisting an intake structure was set at 35% and 65%, respectively. The safety grade of the reservoirs evaluated by applying the newly presented importance values in this study showed the rearrangement of the grades with a change of 11% compared to the previous grades. In this way, the newly established criteria are expected to be utilized as basic data with strategic importance in reservoir safety management and disaster prevention as well as the operation of systems in the future.

계단을 지나는 천수 흐름의 모의에서 내부 경계조건으로서 정확해의 부여에 관한 연구 (A Study on Imposing Exact Solutions as Internal Boundary Conditions in Simulating Shallow-water Flows over a Step)

  • 황승용
    • 대한토목학회논문집
    • /
    • 제34권2호
    • /
    • pp.479-492
    • /
    • 2014
  • 이 연구에서는 계단과 같이 불연속 횡단 구조물을 지나는 천수 흐름에 대해 내부 경계조건으로서 정확해를 부여하는 기법을 제안하였다. 제안된 기법의 검토를 위해 MUSCL이 적용된 HLLL 근사 Riemann 해법을 이용하였다. 계단을 지나는 천수 흐름에 대한 다양한 문제에서 모의 결과는 정확해와 잘 일치하였다. 또한, 계단에서 댐 붕괴 실험 및 급경사 수로 실험의 결과와 부합되었다. 개발된 모형으로 낙차공과 같이 불연속 바닥을 지나는 천수 흐름에 대해 별도의 수위-유량 관계나 지형의 완화 없이 모의가 가능하다. 향후, 계단에 의한 흐름 저항과 수맥에 의한 에너지 손실에 대해 적절한 평가가 이루어진다면, 보나 옹벽(강변 도로)과 같은 불연속 지형을 넘나드는 천수 흐름에 대한 수치모의가 가능할 것으로 기대된다.

어류 이동용 여수로의 자유수면 수치해석 (Numerical Modeling of Free Surface at the Fish Migration Spillways)

  • 이해균
    • 한국콘텐츠학회논문지
    • /
    • 제10권8호
    • /
    • pp.426-432
    • /
    • 2010
  • 두가지 어류이동용 여수로 설계안에 대하여 레블�V 유한요소법을 이용하여 자유수면을 포함한 흐름을 모의하였다. 댐 상류부에서 여수로 입구 방향으로 직각형 유입부를 갖는 여수로와 곡선형 유입부의 여수로에 대하여 흐름의 형상을 모의, 비교하였으며, 또한, 수치해석 결과를 여수로 바닥면의 압력분포와 자유 수면형상에 대하여 수리실험 결과를 통하여 검증하였다. 직각형 여수로가 여수로 유입부에서 자유수면 형상과 압력분포에서 다소 큰 내부 변형율을 보이는 반면, 곡선형 유입부 여수로에서는 작은 변형율을 관찰 할 수 있었다. 여수로 정상부의 대기압보다 작은 부압의 존재 형태는 두가지 형상 모두 유사함을 알 수 있었지만, 전반적으로는 곡선형 유입부 여수로가 어류 이동에 유체역학적으로 더 우호적인 환경을 제공함을 알 수 있었다.

캐나다 시멘트 및 콘크리트의 내구성 및 제성능에 대한 규준 (Durability and Performance Requirements in Canadian Cement and Concrete Standards)

  • Hooton, R.D.
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.5-21
    • /
    • 2006
  • Traditional standards and specifications for concrete have largely been prescriptive, (or prescription-based), and can sometimes hinder innovation and in particular the use of more environmentally friendly concretes by requiring minimum cement contents and SCM replacement levels. In December 2004, the Canadian CSA A23.1-04 standard was issued which made provisions (a) for high-volume SCM concretes, (b) added new performance requirements for concrete, and (c) clearly outlined the requirements and responsibilities for use in performance-based concrete specifications. Also, in December 2003, the CSA A3000 Hydraulic Cement standard was revised. It (a) reclassified the types of cements based on performance requirements, with both Portland and blended cements meeting the same physical requirements, (b) allows the use of performance testing for assessing sulphate resistance of cementitious materials combinations, (c) includes an Annex D, which allows performance testing of new or non-traditional supplementary cementing materials. From a review of international concrete standards, it was found that one of the main concerns with performance specifications has been the lack of tests, or lack of confidence in existing tests, for judging all relevant performance concerns. Of currently used or available test methods for both fresh, hardened physical, and durability properties, it was found that although there may be no ideal testing solutions, there are a number of practical and useful tests available. Some of these were adopted in CSA A23.1-04, and it is likely that new performance tests will be added in future revisions. Other concerns with performance standards are the different perspectives on the point of testing for performance. Some concrete suppliers may prefer processes for both pre-qualifying the plant, and specific mixtures, followed only with testing only 'end-of-chute' fresh properties on-site. However, owners want to know the in-place performance of the concrete, especially with high-volume SCM concretes where placing and curing are important. Also, the contractor must be aware of, and share the responsibility for handling, constructability, curing, and scheduling issues that influence the in-place concrete properties.

  • PDF

Development of a Low-cost and High-efficiency Post-harvest Bulk Handling Machinery System of Onion - Performance Evaluation and Control

  • Park, Jongmin;Kim, Jongsoon;Jung, Hyunmo
    • 한국포장학회지
    • /
    • 제26권2호
    • /
    • pp.61-69
    • /
    • 2020
  • As post-harvest processes of onions are carried by a 20 kg-net package which results in high-cost and low-efficiency, especially, the insufficient drying and physical damage of onions after harvesting leads to a huge second loss in storage, we had developed a low-cost, high-efficiency post-harvest bulk handling machinery system by collecting onions on a farm using ton-bags, drying with forced air circulation, and sorting/packaging. The post-harvest bulk handling machinery system consisted of 6 devices, and this study designed an automatic feed hopper with a feeding rate control device, an inclined belt conveyor with a two-step chute, and an automatic pallet unloading device for feeding onions into the sorting/packing line. This study also analyzed the performance and control of the total system. The device had 1-ton handling capacity, but the operational condition was set to increase the capacity. The three-step filling method of pallet by the velocity control of the inclined belt conveyor was applied in the post-harvest bulk handling machinery system for the prevention of physical damage. If one worker was set to operate the total system, the time required to complete one palletized load was approximately 5 minutes and 5 seconds. The calculated daily handling capacity was approximately 94 tons, when the daily actual working time was 8 hours. When the developed system was applied to the managerial size of 2,000 ton, the processing cost per ton of the system was decreased by 19.5%, compared with the existing 20 kg-net package-based handling. The developed post-harvest bulk handling machinery system would be a good substitute for the rapid decline and aging of rural labor.

말에서 Granulosa Cell Tumor에 의한 무발정 치료 예 (Surgical Treatment for Granulosa Cell Tumor in a Thoroughbred Mare)

  • 서종필;손원균;강수진;김형진;김대용;이충섭;이인형
    • 한국임상수의학회지
    • /
    • 제26권5호
    • /
    • pp.486-489
    • /
    • 2009
  • An 8-year-old Thoroughbred mare showing anestrus for longer than 6 months with left ovarian mass was referred to Veterinary Medical Teaching Hospital of Seoul National University. For 6 months, the mare had received 2 times hormonal therapies with $PGF_2{\alpha}$ and progesterone. The mare had not responded to these therapies and not shown estrous behavior. On rectal palpation, the left ovary was enlarged and contralateral ovary was small and inactive. Transrectal ultrasonographic examination of the left ovary revealed a mass composed of multiple, irregularly shaped follicles. Granulosa cell tumor (GCT) was suspected according to her history. Ovariectomy was performed through the left flank laparotomy with a standing position in a simple chute located outside of horse farm. The mass was diagnosed as GCT on histopathology. The mare was recovered without any problem and became pregnant next spring.

수리 및 수치모형실험을 이용한 여수로 설계 - 화북다목적댐 (Spillway Design by Using Hydraulic and Numerical Model Experiment - Case Study of HwaBuk Multipurpose Dam)

  • 김대근;최지웅;김창시;이지원
    • 한국수자원학회논문집
    • /
    • 제38권3호
    • /
    • pp.179-188
    • /
    • 2005
  • 본 연구에서는 화북다목적댐을 대상으로 2차원, 3차원 수치모형실험이 수리모형실험과 더불어 설계자에게 유용한 해석도구로 사용될 수 있음을 보였다. 2차원, 3차원 수치모형으로 천수방정식을 지배방정식으로 하는 RMA2와 RANS를 지배방정식으로 하는 FLOW-3D 모형을 이용하였다. 수몰지역과 접근수로에서의 유황, 월류웨어의 방류능력, 월류부, 도류부, 감세지에서의 수면형상, 월류부에서의 압력분포에 대한 수치모의 결과를 수리모형실험 결과와 비교하였다. 비교 결과, 대부분의 경우에 수치모의 결과는 수리모형실험 결과를 잘 재현하는 것으로 나타났다 그러나, 감세지에서의 도수현상에 대한 수치모의 결과는 공기연행효과로 인해 수리모형실험 결과와 다소 차이가 발생하는 것으로 나타났다.

Dorsal Track Control (DTC): A Modified Surgical Technique for Atraumatic Handling of the Distal Esophagus in Esophagojejunostomy

  • Lehwald-Tywuschik, Nadja;Steinfurth, Fabian;Kropil, Feride;Krieg, Andreas;Sarikaya, Hulya;Knoefel, Wolfram Trudo;Kruger, Martin;Benhidjeb, Tahar;Beshay, Morris;Esch, Jan Schulte am
    • Journal of Gastric Cancer
    • /
    • 제19권4호
    • /
    • pp.473-483
    • /
    • 2019
  • Surgical therapy for adenocarcinoma of the esophagogastric junction II requires distal esophagectomy, in which a transhiatal management of the lower esophagus is critical. The 'dorsal track control' (DTC) maneuver presented here facilitates the atraumatic handling of the distal esophagus, in preparation for a circular-stapled esophagojejunostomy. It is based on a ventral semicircular incision in the distal esophagus, with an intact dorsal wall for traction control of the esophagus. The maneuver facilitates the proper placement of the purse-string suture, up to its tying (around the anvil), thus minimizing the manipulation of the remaining esophagus. Furthermore, the dorsally-exposed inner wall surface of the ventrally-opened esophagus serves as a guiding chute that eases anvil insertion into the esophageal lumen. We performed this novel technique in 21 cases, enabling a safe anastomosis up to 10 cm proximal to the Z-line. No anastomotic insufficiency was observed. The DTC technique improves high transhiatal esophagojejunostomy.