• Title/Summary/Keyword: Chute

Search Result 47, Processing Time 0.026 seconds

Measuring restraints stress responses using active biotelemetry in cattle (Active biotelemetry를 이용한 젖소의 보정 스트레스 반응 측정)

  • Lee, Dong-Hee;Lee, Byeong-Han;Lim, Joa-Jin;Kim, Jin-Young;Park, Hee-Myung;Chung, Byung-Hyun
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.2
    • /
    • pp.277-282
    • /
    • 2002
  • This study was conducted to investigate the influences of the rope and the tipping chute restraints on body temperature (BT) and heart rate (HR) as acute response for stress caused by restraining for diagnasis and treatment in cattle. Both parameters were recorded by active biotelemetry. In addition cortisol concentration in blood was analyzed as a indicator for stress response. Twelve cattle were divided into two groups based on hydraulic power, the rope restraint group and the tipping chute restraint group. BT and HR were measured at -30 (base), 0, 10, 20, 30, 40, 50, 60, 90, 120, and 180 minutes, including restraint period from 0 to 30 minutes during the experiment. The results obtained in this study was summarized as follows: 1. BT of the rope restraint group was increased ($39.8{\pm}0.3^{\circ}C$) until 20 min after restraint stress for 30 min, and then maintained with high values to the end of experiment. In the tipping chute restraint group, the BT was increased ($39.6{\pm}0.3^{\circ}C$) until the end of the restraint period, but then showed decrese until the end of experiment. 2. HR of both groups was maximized at the beginning of the restraint stress (P<0.05), and then it was decreased gradually but in the tipping chute restraint group showed increase again at the end of the reatraint stress (P<0.05). 3. The cortisol level of the rope restraint group was increased significantly ($9.72{\pm}5.09{\mu}g/d{\ell}$) until 30 min after the end of the restraint stress (P<0.05) and then decreased, but in the tipping chute restraint group showed great increase ($4.68{\pm}1.56{\mu}g/d{\ell}$) at the end of the restraint stress (P<0.05) and then decreased while the tipping chute restraint group was significantly lower than the rope restraint group 30 min after the restraint stress (P<0.05). In conclusion, this study suggests that the tipping chute restraint produces less response to physical stress than the rope restraint but the time for diagnasis and treatment should be shortened when using the tipping chute restraint.

Effect of Solid Side Chute Design for Individual Handling of Hanwoo (Korean Cattle) (한우의 개체관리를 위한 시각제어 유도로 효과)

  • 최재관;이창우;이용준;조광현;최연호;김형철;김시동
    • Journal of Animal Science and Technology
    • /
    • v.48 no.2
    • /
    • pp.331-336
    • /
    • 2006
  • Moving behavior of groups of Hanwoo was observed when solid side was applied along the straight single file chute. Dark blue liners (PVC coated fabric) were hung on the outer side along the steel bars of chute to block vision of cattle. Ten animals were grouped together in a batch to move through chute to the restrainter. Movement of animals through chutes were significantly faster when solid side with liners were applied than when they had open vision of flight zone. And the difference in movement time between of solid side and open side was even greater in a longer chute than in a shorter one. From the experiment with longer chute, we could not find any significant differences between presence or absence of solid sides in the time spent for the leaading cattle to enter the squeeze chute from crowd pen. But the average time spent for movement from squeeze gait to restrainter was 22.78±1.15 seconds with solid sides, which was much shorter than with open sides (40.56±4.46 seconds). Time required for batch of animals to move from crowd pen to restrainter and exit was much faster with solid sides than with open sides: 96.33±3.98 seconds vs. 121.89±5.54 seconds from leading animal to enter the squeeze chute until the last animal of the batch to exit restrainter and 104.56±3.89 vs. 131.22±6.42 seconds for the whole batch of animals to enter the squeeze chute and exit restrainter. Another experiment with shorter chute showed that animals balked to right angled edge of the crowed pen before entering squeeze chute. We could not find any differences in time requred for the leading animal to enter the crowd pen from holding pen. Total time spent from entrance of leading animal to crowd pen until the last animal to exit restrainter was shorter with solid sides than with open sides: 177.44±5.20 seconds vs. 193.44±7.46 seconds.

A Study on the Optimal Shape of Arc Chute for Molded Case Circuit Breakers (배선용 차단기 Arc Chute의 최적형상에 관한 연구)

  • Kim, J.S.;Lee, C.R.;Song, T.H.;Choi, M.J.;Kim, D.J.;Lee, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.926-928
    • /
    • 2002
  • Much progress has been made during the past two decades in numerical analysis of electromagnetic forces in molded case circuit breakers (MCCB) for increasing arc voltage due to the change of the configuration of arc chute and fixed conductor. A review on this topic is given. which mainly covers the past research activities associated with that of our company.

  • PDF

Remote control of Drum/Chute mechanism in a concrete mixer-truck (콘크리트 믹서 트럭에서의 드럼 및 슈트의 원격 제어)

  • Lee, M.C.;Son, K.;Jeong, W.B.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.2
    • /
    • pp.22-29
    • /
    • 1993
  • A remote control system was developed in order to operate by push-buttons the conventional drum and chute components, which have been operated manually, in a concrete mixer-truck. As actuators, a hydraulic power unit was used for chute operations: two DC motors for drum operations. The devised drum controller consisted of three electric circuits : an analog proportional-integral control circuit, a drum acceleration circuit, and an emergency stop circuit. The remote control system was installed to be tested experimentally and then was evaluated to work successfully with a desirable accuracy.

  • PDF

Depositional features and sedimentary facies of steep-faced fan-delta systems: modern and ancient (현생 및 고기 급경사 선상지-삼각쭈계 퇴적층의 특성과 퇴적상)

  • Choe M. Y.;Chough S. K.;Hwang I. G.
    • The Korean Journal of Petroleum Geology
    • /
    • v.2 no.2 s.3
    • /
    • pp.71-81
    • /
    • 1994
  • Alluvial fan delta often extends into deep water, forming steep-faced delta front. Depositional features of modern steep-faced fan-delta slope and prodelta are characterized by slump scar, chute/channel, swale, lobe, splay and debris fall. These features largely originate from sediment failure or sediment-laden underflows (sediment-gravity flows) off river mouth. Sedimentary facies of equivalent ancient systems comprise sheetlike and/or wedged bodies of gravelstone and sandstones, slump-scar and -fill, chute/channel-fills, and sheetlike, lobate and slump mass on steeply-inclined fan-delta foreset and prodelta.

  • PDF

A Study on Feasibility and Applicability of Pneumatic Waste Collection System (쓰레기 수송관로 방식의 적용사례 및 실용에 관한 연구)

  • 민병균;이재영;최상일
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.109-117
    • /
    • 1997
  • The dust chute was a part of equipment in apartment which have been settled down as new residential style in this country since 1960s. However, the dust chute was destructed by results of social discussion, and it ended up old remains which cannot be found in new towns. Nowadays, chute was substituted a collecting system from extra collecting sites which were prepared near residential area. This phenomenon was caused by the poor separating collection. Since the early part of 1995, the whole vocal operating the volume-base charge system has been placed as the institution capable of recycling and separating collection of residential wastes in this country. People pursue the residential quality which is suitable to the Greenround period. Such a diverse effort corresponding to the social change can be also accomplished in the field of waste collecting transportation. In this paper, the local heating system and waste combustion site and hollow are already applied to the new residential area in the form of housing development. After investigating of the waste collecting transportation method in other countries related to such facilities, this paper represents the feasibility and applicability of pneumatic waste collection system which is used practically in the new housing complex and large facilities in other countries.

  • PDF

Velocity Measurement of Granular Flow with Block Matching (블록 매칭을 이용한 Granular Flow의 속도 측정)

  • Lee, Jin-Geol
    • The Journal of Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.5-11
    • /
    • 1997
  • The flow of granular materials is common to many industrial processes. This paper discusses a methodology which utilizes high speed digital imaging to measure velocity of dry granular solids flowing down an inclined chute under the action of gravity. Glass particles have been used as granular solids in our experiment. The proposed technique utilizes block matching for spatially averaged velocity measurements of the glass particles. The velocity measurements are refined to the subpixel resolution by the variance normalized correlation with interpolation.

  • PDF

A Study on the Upgrading Program of HDB in Singapore (싱가포르 주택개발청(HDB)의 업그레이딩 프로그램에 관한 연구)

  • 김주현;박선경;하재명;이재윤
    • Journal of the Korean housing association
    • /
    • v.15 no.2
    • /
    • pp.97-105
    • /
    • 2004
  • This research is about Apartment Remodeling Upgrading Programme by Singapore Housing Development Board(HDB). For this study, we visited HDB and made field survey of the projects. There are basically three types of upgrading, namely, Precinct Upgrading, Apartment Block Upgrading and Flat Upgrading. Precint Upgrading refers the upgrading of services and facilities of the precinct. It involves the extention of open space, car-park, commercial space and additional covered linkways. These afford the residents greater convenience and comfort and generally enhance the environment of the community. Apartment Upgrading refers the upgrading of the block facade, improvements to the elevator, lift lobbies, letter boxes, trash chute and rain chute. The upgrading improves the quality of life of the residents. Flat Upgrading Involves the addition of space which may be in the form of a new Utility-room, replacement of old services, piping and equipment within an apartment unit. These provide the residents with a bigger and more comfortable living space.

Effects of Grid Characteristics on High Speed Circuit Breaker for Railway Vehicle (철도 차량용 직류 고속도 차단기의 그리드 특성 해석)

  • Park, Ji-Won;Jung, Jooyoung;Choi, Jinnil
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.2
    • /
    • pp.117-123
    • /
    • 2016
  • High speed circuit breakers(HSCB) interrupt the generated arc within the arc chute to turn off the electricity flowing through the main circuit to prevent ground faults. In order to explore the arc generated from the contactor operation, arc definition, establishment of arc interruption method, and analysis of magnetic driving force are required. In this paper, arc interruption capability has been estimated by exploring the difference in magnetic flux density of Lorenz forces using finite element analysis. In addition, since the number of grids and changes in the grid shape within the arc chute influence the formation of the inner magnetic field, its effects have been explored to enhance arc interruption capability. Assessment of interruption capability and analysis of grid shape, with rated operating current, are reported.