• Title/Summary/Keyword: Chromium ion

Search Result 146, Processing Time 0.025 seconds

Separation of Chromium(VI) Ion in Industrial Waste Water throunh Liquid Surfactant Membrane (산업폐수중 유화액막에 의한 크롬(VI)의 분리)

  • 초민승;강안수;우인성;이영순
    • Journal of the Korean Society of Safety
    • /
    • v.4 no.1
    • /
    • pp.15-24
    • /
    • 1989
  • The transport of Chromium(Vl) ion from waste water throughl the liquid surfactant membrane containing tri-n-octylamine as a carrier, was analyzed by a slab model and was investigated through experiments. For the experiment of membrane stability, concentrations of surfactant and liquid parafnn oil were analyzed. Extraction euperiments were carried out to observe the effect of system variables, such as stirring speed, concentration of carrier, and NaOH in internal aqueous phase, and concentrations of H$_2$SO$_4$and initial chromium(VI) ion in external aqueous phase at $25^{\circ}C$. It is concluded that the most stable formation of liquid membrane emulsion was obtained when surfactant concentration is above 3 wt. % and liquid parafnn oil concentration is 50 vol. %. The transport of chromium(VI) ion in bacth extractor increased with increasing carrier concentration, the volume ratio of emulsion to external aqueous phases, and initial concentration of chromium(VI) ion under the optimum stirring speed of chromium(VI) ion below 2 ppm. The theoretical equation on the transport of chromium(Vl) ion agreed well with the experimental results.

  • PDF

Dropwise condensation induced on chromium ion implanted aluminum surface

  • Kim, Kiwook;Lee, Youngjin;Jeong, Ji Hwan
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.84-94
    • /
    • 2019
  • Aluminum substrates are irradiated with chromium ions and the steam condensation heat transfer performance on these surfaces is examined. Filmwise condensation is induced on the surface of aluminum specimens irradiated with chromium ion dose of less than $10^{16}ions/cm^2$ while dropwise condensation occurs on the specimens irradiated with chromium ion dose of $5{\times}10^{16}ions/cm^2$ in the range of ion energy from 70 to 100 keV. The heat transfer coefficient of the surfaces on which dropwise condensation occurs appeared to be approximately twice as much as the prediction by Nusselt's film theory. In a durability test, dropwise condensation lasts over six months and the heat transfer coefficient is also maintained.

Optical Probe for Determination of Chromium(III) Ion in Aqueous Solution Based on Sol-Gel-Entrapped Lucigenin Chemiluminescence

  • Li, Ming;Kwak, Jun-Hee;Kim, Chang-Jin;Lee, Sang-Hak
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.103-108
    • /
    • 2003
  • A method to determine chromium(III) ion in aqueous solution by chemiluminescence method using a lucigenin entrapped silica sol-gel film has been studied. An optical probe for chromium(III) ion has been prepared by entrapping lucigenin into silica sol-gel film coated on a glass support by dip coating. The chromium(III) optical sensor is based on the catalytic effect of chromium(IIII) ion on the reaction between lucigenin and hydrogen peroxide in basic solutions. The effects of Nafion, DMF and Triton X-100 were investigated to find the optimum condition to minimize cracking and leaching from the probe. The effects of pH and concentrations of lucigenin and hydrogen peroxide on the chemiluminescence intensity were investigated. The chemiluminescence intensity was increased linearly with increasing chromium(III) concentration from $2.5{\times}10^{-4}$M to $8.0{\times}10^{-7}$M and the detection limit was $4.0{\times}10^{-7}$M.

  • PDF

Crystal Growth of Chromium (4+) Ion Doped Yttrium Aluminum Garnet

  • Yu, Y.M.;Jeong, S.J.;Koh, J.C.
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1998.09a
    • /
    • pp.53-53
    • /
    • 1998
  • Four valence of Chromium ion doped Yttrium Aluminum Garnet crystals were grown by Floating Zone and Czochralski methods. Changes of valence for Chromium (3+) ion to Chromium (4+) were achieved by substitution of Yttrium ion in dodecahedral site to Calcium and by substitution of Aluminum in octahedral site to Magnesium. Growth conditions for high quality of crystals were investigated. Grown crystals were cut and polished and then observed various types of defects. Characterizations by means of measurement of density and lattice parameter as a function of solidification fraction were performed. Results of Q-switching test using grown crystals were also reported.

  • PDF

Extraction of Chromium (Vl) Son in Waste Water through the Liquid Surfactant Membrane with Open-Type Perforated Reciprocating-Plate Column (개방형 왕복 다공판 추출탑을 이용한 액막법에 의한 폐수중 Cr(Vl)의 추출)

  • 우인성;강현춘;안형환
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.2
    • /
    • pp.44-50
    • /
    • 1993
  • The objective of this study was to investigate the extraction of chromium(Vl) ion in waste water through the liquid surfactant membrane with open-type Perforated Reciprocating-Plate Column. Extraction experiments were conducted to measure the effect of flow characteristics of continuous and dispersed phase and stroke velocity, sodium hydroxide concentraction in internal aqueous phase, sulfuric acid concentraction in outer phase, and residence time distribution and measured extraction velocity. The result of experiments showed that extraction velocity of chromium ion was maximum when stroke velocity was 180 1/min and dispersion phase velocity was 30m11min, continuous phase velocity was 20m1/min. Extraction velocity of chromium ion increased with increasing difference of hydrogen ion concentraction of dispersion and continuous phase and column stage decreased.

  • PDF

An Investigation on the Extraction and Quantitation of a Hexavalent Chromium in Acrylonitrile Butadiene Styrene Copolymer (ABS) and Printed Circuit Board (PCB) by Ion Chromatography Coupled with Inductively Coupled Plasma Atomic Emission Spectrometry

  • Nam, Sang-Ho;Kim, Yu-Na
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.6
    • /
    • pp.1967-1971
    • /
    • 2012
  • A hexavalent chromium (Cr (VI)) is one of the hazardous substances regulated by the RoHS. The determination of Cr (VI) in various polymers and printed circuit board (PCB) has been very important. In this study, the three different analytical methods were investigated for the determination of a hexavalent chromium in Acrylonitrile Butadiene Styrene copolymer (ABS) and PCB. The results by three analytical methods were obtained and compared. An analytical method by UV-Visible spectrometer has been generally used for the determination of Cr (VI) in a sample, but a hexavalent chromium should complex with diphenylcarbazide for the detection in the method. The complexation did make an adverse effect on the quantitative analysis of Cr (VI) in ABS. The analytical method using diphenylcarbazide was also not applicable to printed circuit board (PCB) because PCB contained lots of irons. The irons interfered with the analysis of hexavalent chromium because those also could complex with diphenylcarbazide. In this study, hexavalent chromiums in PCB have been separated by ion chromatography (IC), then directly and selectively detected by inductively coupled plasma atomic emission spectrometry (ICP-AES). The quantity of Cr (VI) in PCB was 0.1 mg/kg.

A Study of the Potential Interference of ArC+ on the Direct Determination of Trivalent Chromium and Hexavalent Chromium Using Ion Chromatography Coupled with ICP-MS

  • Nam, Sang-Ho;Park, Young-Il;Kim, Jae-Jin;Han, Sun-Ho;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.447-451
    • /
    • 2004
  • Low and high resolution inductively coupled plasma mass spectrometry (ICP-MS) coupled with ion chromatography (IC) has been investigated for speciation of Cr(III) and Cr(VI). In particular, the interference of ArC^+formed by the carbon in a sample on the simultaneous determination of Cr(III) and Cr(VI) has been studied. In chemical speciation, this study shows that quadrupole type ICP-MS with low resolution has a limitation of simultaneous determination fo chromium species if the sample contains the carbon elements. The interference problems can be solved by high resolution ICP-MS.

The Electrical Characteristics of Chromium Oxide Film Produced by Son Beam Sputter Deposition (이온선 스퍼터 증착법에 의하여 제조된 CrOx의 전기적 특성)

  • 조남제;이규용
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.6
    • /
    • pp.518-523
    • /
    • 2002
  • The influences of ion beam energy and reactive oxygen partial pressure on the physical and crystallographic characteristics of transition metal oxide compound(CrOx) film were studied in this paper. Chromium oxide films were deposited onto a cover-glass using ion Beam Sputter Deposition(IBSD) technique according to the various processing parameters. Crystallinity and grain size of as-deposited films were analyzed using XRD analysis. Thickness and Resistivity of the films were measured by $\alpha$-step and 4-point probe measurement. According to the XRD, XPS and resistivity results, the deposited films were the cermet type films which had crystal structure including amorphous oxide(a-oxide) phase and metal Cr phase simultaneously. The increment of the ion beam energy during the deposition process led to decreasing of metal Cr grain size and the rapid change of resistivity above the critical $O_2$ partial pressure.

Trimeric Chromium Oxyformate Route to Chromia-Pillared Clay

  • Yun, Ju Byeong;Hwang, Seong Ho;Choe, Jin Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.10
    • /
    • pp.1049-1051
    • /
    • 2000
  • A chromia-pillared clay has been prepared by ion exchange type intercalation reaction between the sodium ion in montmorillonite and the trimeric chromium oxyformate (TCF) ion, and by subsequent heat-treatment. The structural and thermal properties have been systematically studied by thermal analysis, powder XRD, IR spec-troscopy, and XAS. The gallery height of~6.8 $\AA$ upon intercalation of the TCF ion suggests that the $Cr_3O$ plane is parallel to the aluminosilicate layers. Even though the basal spacing of TCF intercalated clay decreases slightly upon heating, the layer structure was retained up to $550^{\circ}C$ as confirmed by XRD and TG/DTA. Ac-cording to the EXAFS spectroscopic analysis, it is identified that the (Cr-Cr) distance of 3.28 $\AA$ between vertex-linked CrO6 octahedra in TCF splits into 2.64 $\AA$, 2.98 $\AA$, and 3.77 $\AA$ due to the face-, edge-, and corner-shared CrO6 octahedra after heating at $400^{\circ}C$, implying that a nano-sized chromium oxide phase was stabilized within the interlayer space of clay.

Tansport Rate of Chromium ion from Waste Water through the Liquid Surfactant Membrane Containing Carrier (운반체 함침 유화액막에 의한 폐수중 크롬(VI)의 이동속도)

  • Woo, In-Sung;Kim, Kyoung-Ho;Lee, Sang-Jin;Kang, An-Soo;Choi, Sei-Young
    • Elastomers and Composites
    • /
    • v.23 no.1
    • /
    • pp.11-17
    • /
    • 1988
  • The transport of chromium(VI) ion from waste water through the liquid surfactant membrane containing tri-n-octylamine as a carrier, was analyzed by a slab model and was investigated through experiments. For the experiment of membrane stability, concentrations of surfactant and liquid paraffin oil were analyzed. Extraction experiments were carried out to observe the effect of system variables, such as concentrations of carrier, and initial chromium(VI) ion in external aqueous phase at $25^{\circ}C$. It is concluded that the most stable formation of liquid membrane emulsion was obtained when surfactant concentration is above 3 wt.% and liquid paraffin oil concentration is 50 vol.%. The theoretical equation on the transport of chromium(VI) ion agreed well with the experimental results.

  • PDF