• Title/Summary/Keyword: Chopper Amplifier

Search Result 23, Processing Time 0.025 seconds

Flow Velocity Measurement for Laminar Diffusion Flames Utilizing LII Signal from Soot Particles (매연입자의 LII 신호를 이용한 충류확산화염 유동속도 측정)

  • Lee, Jung-Soo;Nam, Youn-Woo;Lee, Won-Nam
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.157-163
    • /
    • 2006
  • A new technique utilizing LII signal for the measurement of flow velocities of laminar diffusion flames has been investigated. Soot particles in ethylene diffusion flames are heated by a modulated Ar-ion laser beam. LII signals and their phase angles are measured using a lock-in amplifier at the different flame heights and the axial flow velocity are obtained from the measured phase angle delay. The measured velocities are similar to those from LDV measurements under the same operating conditions. The effects of laser power, LII signal wavelength, and modulation frequency are not sensitive to the velocity measurement. However, the choice of an optical chopper blade type could affect the measurement result. The use of a 6/5 chopper blade showed the better result that is possibly due to the square shape of modulated laser beam. This study successfully demonstrated that axial flow velocities of laminar diffusion flames can be measured by a new technique utilizing LII signal, which does not need particle seeding unlikely to LDV or PIV techniques.

  • PDF

CMI Tolerant Readout IC for Two-Electrode ECG Recording (공통-모드 간섭 (CMI)에 강인한 2-전극 기반 심전도 계측 회로)

  • Sanggyun Kang;Kyeongsik Nam;Hyoungho Ko
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.432-440
    • /
    • 2023
  • This study introduces an efficient readout circuit designed for two-electrode electrocardiogram (ECG) recording, characterized by its low-noise and low-power consumption attributes. Unlike its three-electrode counterpart, the two-electrode ECG is susceptible to common-mode interference (CMI), causing signal distortion. To counter this, the proposed circuit integrates a common-mode charge pump (CMCP) with a window comparator, allowing for a CMI tolerance of up to 20 VPP. The CMCP design prevents the activation of electrostatic discharge (ESD) diodes and becomes operational only when CMI surpasses the predetermined range set by the window comparator. This ensures power efficiency and minimizes intermodulation distortion (IMD) arising from switching noise. To maintain ECG signal accuracy, the circuit employs a chopper-stabilized instrumentation amplifier (IA) for low-noise attributes, and to achieve high input impedance, it incorporates a floating high-pass filter (HPF) and a current-feedback instrumentation amplifier (CFIA). This comprehensive design integrates various components, including a QRS peak detector and serial peripheral interface (SPI), into a single 0.18-㎛ CMOS chip occupying 0.54 mm2. Experimental evaluations showed a 0.59 µVRMS noise level within a 1-100 Hz bandwidth and a power draw of 23.83 µW at 1.8 V.

Modulated LII technique for the Measurement of Flow Velocity in Laminar Flames (층류화염 유동속도 측정을 위한 modulated LII 기법)

  • Lee, Won-Nam;Lee, Jung-Soo;Nam, Youn-Woo
    • Journal of the Korean Society of Combustion
    • /
    • v.11 no.3
    • /
    • pp.36-43
    • /
    • 2006
  • The modulated LII technique has been suggested for the measurement of axial velocity profiles of laminar diffusion flames. The theoretical background is explained based on the blackbody radiation and LII signal. Experimentally, soot particles in ethylene diffusion flames are heated by a modulated Ar-ion laser beam. LII signals and their phase angles are measured using a lock-in amplifier at the different flame heights and the axial flow velocities are obtained from the measured phase angle delay informations. The measured velocities are similar to those from LDV measurements under the same operating conditions. The effects of laser power, LII signal wavelength, and modulation frequencies are not sensitive to the velocity measurement. However, the choice of an optical chopper blade type could affect the measurement result. The use of a 6/5 chopper blade showed the better result that is. possibly due to the square shape of modulated laser beam. This study successfully demonstrated that axial flow velocities of laminar diffusion flames can be measured by a new technique utilizing LII signal, which does not need particle seeding unlikely to LDV or PIV techniques.

  • PDF

A Study on the Linear Counting Ratemeter (선형 계수율계에 관한 연구)

  • 이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.6
    • /
    • pp.8-16
    • /
    • 1971
  • This paper describes the transistorized linear counting ratemeter which can be uses to indicate on the meter or record the counting rates of the nuclear radiations produced from the atomic reactor or from the radio isotopes. Tte feature of this ratemeter is the use of the transistor chopper for good stabilization. At the input stage of the a. c. amplifier a composite emitter follower buffer stage has been used to give the high input impedance. A hybrid parameter equivalent circuit was modeled for the analysis of this buffer stage. The counting rates can be linearly measured from few CPS up to 100KCPS in 4 ranges. The resolution is less than 0.5$\mu$sec and the output drift at the room temperature with 7-hour continuous operation is in the order of $\pm$0.5$\mu$A.

  • PDF

A Hybrid Audio ${\Delta}{\Sigma}$ Modulator with dB-Linear Gain Control Function

  • Kim, Yi-Gyeong;Cho, Min-Hyung;Kim, Bong-Chan;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • v.33 no.6
    • /
    • pp.897-903
    • /
    • 2011
  • A hybrid ${\Delta}{\Sigma}$ modulator for audio applications is presented in this paper. The pulse generator for digital-to-analog converter alleviates the requirement of the external clock jitter and calibrates the coefficient variation due to a process shift and temperature changes. The input resistor network in the first integrator offers a gain control function in a dB-linear fashion. Also, careful chopper stabilization implementation using return-to-zero scheme in the first continuous-time integrator minimizes both the influence of flicker noise and inflow noise due to chopping. The chip is implemented in a 0.13 ${\mu}m$ CMOS technology (I/O devices) and occupies an active area of 0.37 $mm^2$. The ${\Delta}{\Sigma}$ modulator achieves a dynamic range (A-weighted) of 97.8 dB and a peak signal-to-noise-plus-distortion ratio of 90.0 dB over an audio bandwidth of 20 kHz with a 4.4 mW power consumption from 3.3 V. Also, the gain of the modulator is controlled from -9.5 dB to 8.5 dB, and the performance of the modulator is maintained up to 5 nsRMS external clock jitter.

A Study on The Bang-Bang Controller Applied to Electrical Vehicle (전기차량에 적용한 Bang-Bang 제어기 연구)

  • Bae, Jong-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1089-1094
    • /
    • 2016
  • In order to establish the robust controller design technique of series wound motor driver system. This paper proposes a method of Bang-Bang controller using a series wound motor driver system under improperly variable load. A Bang-Bang controller structure is simpler than the structure of PID plus Bang-Bang controller. This paper shows that a general 8 bits microprocessor is used efficiently implementing such an algorithm. The calculation time of software is extremely small when compared with conventional PID plus Bang-Bang controller. Both nonlinear operating characteristics of digital switching elements and describing function methods are used for the analysis and synthesis. Real time implementation of Bang-Bang controller is achieved. Concept design strategy of the control and PWM waveform generation algorithms are presented in the paper.

A Study on the Detection of Surface Acoustic Waves by Noncontact Method (비접촉 방법에 의한 표면탄성파의 검출)

  • You, I.H.;Yoon, J.S.;Kim, D.I.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.2
    • /
    • pp.56-62
    • /
    • 1990
  • Surface Acoustic Waves(SAW) are generated on silicon wafer and $YZ-LiTaO_3$ substrate and are detected by noncontact method. As wave sources two kinds of transducers are used : the wedge-type of 20.0 MHz and fabricated Interdigital Transducer(IDT) of 20.8 MHz. SAW are modulated by the optical chopper frequency and are syncronized with a laser beam. In signal processing, intensity variations of light due to the intensity of SAW are analyzed using lock- in amplifier. From the results, corresponding to the applied input power, the intensity variations of a deflected light by corrugations on the substrates are increased and saturation phenomenon is observed.

  • PDF

Study on the High Sensitive Three Phase Power Factor Meter and Relay (고감도 삼상력률계전기에 관한 연구)

  • 박정후
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.16 no.1
    • /
    • pp.43-47
    • /
    • 1980
  • The author designed and tested the high sensitive three-phase power factor meter and relay circuit, and dealt with the circuit to detect the phase of the current and the voltage. An operational amplifier comparator circuit and two single-phase transformers are used to control and detect the phase angle between the current and the voltage. The results obtained are as follows: 1. Converting the sine wave input current into the constant amplitude rectangular wave form by using a transistor chopper circuit, the power factor can be measured precisely over the load current of 0.08 A. 2. Using the moving coil type current meter, the power factor meter can be read in uniform . scale all over the range. 3. Using the three-phase power factor meter, the power factor relay which works at any power factor can be made.

  • PDF

A Study on the Attenuation of Surface Acoustic Waves by Optical Measurement Method (광학적 측정방법에 의한 표면 탄성파의 감쇠에 관한 연구)

  • You, I.H.;Kim, D.I.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.4
    • /
    • pp.237-243
    • /
    • 1995
  • We have studied methods of detecting attenuation of solid materials such as silicon wafer and piezoelectric $LiTaO_3$ by means of optical probing techniques. We have performed measurements of surface acoustic waves(SAW) generated from 90 degree wedge type transducer and also from inter-digital transducers(IDT). SAW of 20.0 MHz was generated on a silicon wafer from the 90 degree wedge type transducer and those of 20.8 and 14.5 MHz are generated on a $LiTaO_3$ from the IDT. Then any surface-corrugation resulted from the above SAW was investigated by He-Ne laser beams. We projected laser beams, which were modulated by an optical chopper, on the SAW of the same frequency and then measured the scattered beam by the lock-in amplifier. We modulated and synchronized both SAW and the incident laser beam as well as the phase sensitive detector(PSD) to the same frequency in order to simplify our measurement system. We obtained the attenuation coefficients of SAW to be $0.62{\sim}0.75dB/mm$(from IDT1, 20.8 MHz), and $0.60{\sim}0.72dB/mm$(from IDT2, 14.5 MHz), $0.83{\sim}1.28dB/mm$(from the wedge type), respectively.

  • PDF

Development of an Active Dry EEG Electrode Using an Impedance-Converting Circuit (임피던스 변환 회로를 이용한 건식능동뇌파전극 개발)

  • Ko, Deok-Won;Lee, Gwan-Taek;Kim, Sung-Min;Lee, Chany;Jung, Young-Jin;Im, Chang-Hwan;Jung, Ki-Young
    • Annals of Clinical Neurophysiology
    • /
    • v.13 no.2
    • /
    • pp.80-86
    • /
    • 2011
  • Background: A dry-type electrode is an alternative to the conventional wet-type electrode, because it can be applied without any skin preparation, such as a conductive electrolyte. However, because a dry-type electrode without electrolyte has high electrode-to-skin impedance, an impedance-converting amplifier is typically used to minimize the distortion of the bioelectric signal. In this study, we developed an active dry electroencephalography (EEG) electrode using an impedance converter, and compared its performance with a conventional Ag/AgCl EEG electrode. Methods: We developed an active dry electrode with an impedance converter using a chopper-stabilized operational amplifier. Two electrodes, a conventional Ag/AgCl electrode and our active electrode, were used to acquire EEG signals simultaneously, and the performance was tested in terms of (1) the electrode impedance, (2) raw data quality, and (3) the robustness of any artifacts. Results: The contact impedance of the developed electrode was lower than that of the Ag/AgCl electrode ($0.3{\pm}0.1$ vs. $2.7{\pm}0.7\;k{\Omega}$, respectively). The EEG signal and power spectrum were similar for both electrodes. Additionally, our electrode had a lower 60-Hz component than the Ag/AgCl electrode (16.64 vs. 24.33 dB, respectively). The change in potential of the developed electrode with a physical stimulus was lower than for the Ag/AgCl electrode ($58.7{\pm}30.6$ vs. $81.0{\pm}19.1\;{\mu}V$, respectively), and the difference was close to statistical significance (P=0.07). Conclusions: Our electrode can be used to replace Ag/AgCl electrodes, when EEG recording is emergently required, such as in emergency rooms or in intensive care units.