• Title/Summary/Keyword: Chonnam Province

Search Result 345, Processing Time 0.072 seconds

Transition of Rice Culture Practices during Chosun Dynasty through Old References V. Cultivation and Cropping Patterns (주요 고농서를 통한 조선시대의 도작기술 전개 과정 연구 V. 재배양식)

  • Lee, Sung-Kyum;Guh, Ja-Ok;Lee, Eun-Woong;Lee, Hong-Suk
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.1
    • /
    • pp.104-115
    • /
    • 1992
  • The rice culture techniques included 'Jodosukyungbeob'(旱稻水耕法 : culture techniques of early-ripening paddy rice), 'Mandosukyungbeob' (晩稻水耕法) : culture techniques of late-Ripening paddy rice 'Handobeob'(旱稻<山稻>法 : culture techniques of upland rice), 'Myojongbeob'(苗種法 : culture techniques of paddy rice by transplanting), 'Kunangbeob'(乾秧法 : culture techniques of rice by transplanting which rears seeding in dry paddy) and 'Sudogunpanongbeob'(水稻乾播農法 : culture techniques of paddy rice seeding in dry field). Especially, 'Kunangbeob' and 'Sudogunpanongbeob' were originally developed in Korea as seen in 1600s(Kyoungje : 經濟) and early 1800s (Yoji : 要旨). In 'Jodosukyungbeob' it took 9 days for seed dipping, water-sprouting and prevent damage by birds, each for 3 days in China, but in Korea seed dipping in water took 3 days and the rest of the procedures were flexibly established. In matured soils, practices were fall plowing right after harvest, recognition of effective tillering and additional fertilization use of human manure, and stimulation of sprouting by lime application. The unique culture techniques adequate for Korean situations were practiced, which included weed control after draining accurately for 3 to 4 times, draining at mid season for improving wind and drought tolerance, rice harvesting at appropriate time for preventing grain shattering, and seeding in rows. 'Mandosukyungbeob' was improved techniques contrast to those of China, and the major contents were selection of proper varieties, good stand establishment by seeding high rates, induction of vigorous tillers, and adoption of 'Jokjongbeob'(足種法 : seeding method by foot). Also, one of the most prominent rice cultures by our ancestors was 'Kunpanongbeob' that was systemized form habitual practice of Pyongan Province. The unique technique actualized was 'Hando [旱稻(山稻)]' culture technique which was the combinations of 'Jokjongbeob', root stimulation method, and disaster-tolerant mixture cropping with adoptation of variety theory, although it was originated from China. The transplanting techniques has come before 'Jikseol'($\ulcorner$直說$\lrcorner$) and its merits were sufficiently realized. However, this method was basically prohibited from the early Chosun dynasty because extremely bad harvest was expected under drought conditions and insufficient conditions of water storage. But, it was permitted in the areas that contained water all the times and in case of large-scale farming especially. Most of rice culture was transplanted in the end of the Chosun dynasty because transplanting was continuously spreaded in the three southern provinces of Korea. Under these circumstances, transplanting technique was improved from the early to the end of the Chosun dynasty by weed control, fertilizing, water management, and quadratic transplanting. Based on these techniques, agricultural productivity was improved 5 times by that time. 'Kunpanongbeob' was created and developed properly for Korean conditions that is dry in early season and flooding in late season. This was successively developed and established into transplanting technique of nursery seedling.

  • PDF

The Status, Problems and Countermeasure of Direct Rice Seeding in Honam Province - On Weed control - (호남지방(湖南地方) 직파재배(直播栽培)의 현황(現況), 문제점(問題點) 및 대책(對策) - 잡초방제적(雜草防除的) 측면(側面)에서 -)

  • Ryang, Hwan-Seung;Kim, Jong-Seog
    • Korean Journal of Weed Science
    • /
    • v.12 no.3
    • /
    • pp.271-291
    • /
    • 1992
  • This study was conducted to survey the situation of direct rice seeding in Honam province in Korea to investigate problems and seek countermeasure of weed control in direct rice seeding. The total area of direct rice seeding in the south-western part of Korea (Chonbuk, Chonnam, and Chungnam) was 1650.8ha (732.1ha for direct seeding in dry field and 918.7ha for direct seeding in flooding field) in 1992. The followings are summary of the study. 1. In case of direct rice seeding in dry field, butachlor EC and G at 3 to 5 DAS was mostly selected by farmers to control weeds in dry field. Benthiocarb or chlornitrofen was also used in few cases. At 10 to 14 DAS just before rice emergence, tank misture of butachlor EC and paraquat was treated by some farmers. At 35 to 40 days, after flooding mixture of sulfonylurea derivatives was sequentially applied. Surviving weeds including barnyardgrass were finally controlled by mixture of bentazon+quinclorac WP foliage application. 2. In case of direct rice seeding in flooding field, weed control were mostly unsuccessful partially due to wrong selection of herbicide and missing the optimum application time. Three relatively successful weed control in the survey were summarized as follows. 1) Oxadiazon EC, butachlor or benthiocarb were treated just after puddling(5 to 7 days before seeding). then mixture of bentazone+quinclorac WP or sulfonylurea derivatives was sequently applied to control remaining weeds at 20 days after seeding. 2) Mixtures of bensulfuronmethyl+dimepiperate G, pyrazosulfuronethyl+molinate G, or bensulfuronmethyl+mefenacet+dymron G were applied at 11 days after puddling when barnyardgrass were at 2.0 leaf stage. Phytotoxicity was not found in case of mixture of bensulfuronmethyl+dimepiperate G but found in the other two cases but disappeared later. 3) Mixtures of bensulfuronmethyl+quinclorac G., pyrazosulfuronethyl+quinclorac G or betazone and quinclorac G were treated after 18 to 20 days after puddling when barnyardgrass was within 3.0 leaf stage. It showed good weed control in both annuals and perrenials without phytotoxicity. On the contrary, other sulfonylurea derivatives such as middle periodic herbicide showed poor weed control against barnyardgrass, so that sequential treatment of bentazone+quinclorac WP mixture was required. 3. Herbicidal characteristics and optimum application time of 45 rigistered herbicides in Korea were analyzed to discover new substitute for quinclorac mixture, that showed excellent weed control against barnyardgrass at its 3 leaf stage or older. The analysis revealed that 70% of herbicides were for preemergence and the others were post periodic herbicide. Most farmers favor to apply herbicide when rice seedlings completely rooted, at this time barnyardgrass are at 2.5-3.0 leaf stage. Therefore herbicide of which optimum application time had long is required. In this study. 6 middle periodic herbicides among sulfonylurea derivatives and 2 quinclorac mixture were selected and evaluated their weeding spectrums at different leaf stage of barnyardgrass in both soil application in flooding condition and foliage application in dry paddy field. The order of weeding spectrum in magnitude was as follows : bentazone+quinclorac WP> bentazone + quinclorac G>bensulfuronmethyl + quinclorac G>pyrazosulfuronethyl + quinclorac G> pyrazosulfuronethyl + Molinate G>bensulfuronmethyl + mefenacet + dymron G>bensulfuronmethyl + mefenacet G>bensulfuron methyl+benthiocarb G. The above results coincided with that of the survey. In conclusion, there is no proper substitute for quinclorac mixrure, which can control barnyardgrass at 3.0 leaf stage or even older. Therefore quinclorac should be supplied continuously to farmers in order to anchor direct rice seeding in Korea. Author suggested the followings to eastablish direct rice seeding technology effectively and quickly : 1) A tentatively named "The research committee for direct rice seeding" which was composed of farmers. researchers and goberment. should be eastablished to cooperate effectively. 2) Development of a pricise direct rice seeding machine for both dry and flooding paddy field. which is workable regardless of condition and varieties of seeds. 3) Study on protecting rice seed and seedling from sparrows. 4) Systematic studies of weed control techniques in direct rice seeding to standardize herbicide application. 5) Studies on farm-land reformation. techniques of precise land preparation. and direct rice seeding using an airplane.

  • PDF

Effects of Soil Hardness on the Root Distribution of Pinus rigida Mill. Planted in Association with Sodding Works on the Denuded Land (사방시공지(砂防施工地)에 있어서 리기다소나무의 수근(樹根)의 분포(分布)에 미치는 토양견밀도(土壤堅密度)의 영향(影響))

  • Cho, Hi Doo
    • Journal of Korean Society of Forest Science
    • /
    • v.56 no.1
    • /
    • pp.66-76
    • /
    • 1982
  • Soil harness represents such physical properties as porosity, amount of water, bulk density and soil texture. It is very important to know the mechanical properties of soil as well as the chemical in order to research the fundamental phenomena in the growth and the distribution of tree roots. The writer intended to grip soil hardness by soil layer and also to grasp the root distribution and the correlation between soil hardness and the root distribution of Pinus riguda Mill. planted on the denuded hillside with sooding works by soil layer on soil profile. The site investigated is situated at Peongchang-ri 13, Kocksung county, Chon-nam Province. The area is consisted of 3.63 ha having on elevation of 167.5-207.5 m. Soil texture is sandy loam and parant rock in granite. Average slope of the area is $17^{\circ}-30^{\circ}$. Soil moisture condition is dry. Main exposure of the area is NW or SW. The total number of plots investigated was 24 plots. It divided into two groups by direction each 12 plots in NW and SW and divided into three groups by the position of mountain plots in foot of mountain, in hillside, and in summit of mountain, respectively. Each sampling tree was selected as specimen by purposive sampling and soil profile was made at the downward distance of 50cm form the sampling tree at each plot. Soil hardness, soil layer surveying, root distribution of the tree and vegetation were measured and investigated at the each plot. The soil hardness measured by the Yamanaka Soil Hardness Tester in mm unit. the results are as follows: 1) Soil hardness increases gradually in conformity with the increment of soil depth. The average soil indicator hardness by soil layer are as follows: 14.6mm in I - soil layer (0-10cm in depth from soil surface), 16.2mm in II - soil layer (10-20cm), 17.2 in III - soil layer (20-30cm), 18.3mm in IV - soil layer(30-40cm), 19.8mm in V - soil layer (4.50mm). 2) The tree roots (less than 20mm in diameter) distribute more in the surface layer than in the subsoil layer and decrease gradually according to the increment of soil depth. The ratio of the root distribution can be illustrated by comparing with each of five soil layers from surface to subsoil layer as follows: I - soil layer; 31%, II - soil layer; 26%, III - soil layer; 18%, IV - soil layer; 12%, V - soil layer; 13%, 3) Soil hardness and tree root distribution (less than 20mm in diameter) of Pinus rigida Mill. correlate negatively each other; the more soil hardness increases, the most root distribution decreases. The correlation coefficients between soil hardness and distribution of tree roots by soil layer are as follows: I - soil layer; -0.3675 (at the 10% significance level), II - soil layer; -0.5299 (at the 1% significance level), III - soil layer; -0.5573 (at the 2% significance level), IV - soil layer; -0.6922 (at the 5% significance level), V - soil layer; -0.7325 (at the 2% significance level). 4) the most suitable range of soil hardness for the growth of Pinus rigida Mill is the range of 12-14.9mm in soil indicator hardness. In this range of soil indicator hardness, the root distribution of this tree amounts to 41.8% in spite of 33% in soil harness and under the 20.9mm of soil indicator hardness, the distribution amounts to 93.2% in spite of 82% in soil hardness. Judging from above facts, the roots of Pinus rigida can easily grow within the soil condition of 20.9mm in soil indicator hardness. 5) The soil layers are classified by their depths from the surface soil.

  • PDF

TECHNICAL STUDY ON THE CONTROLLING MECHANIQUES OF THE ENVIRONMENTAL FACTORS IN THE MUSHROOM GROWING HOUSE IN CHONNAM PROVINCE (전남지방(全南地方)에 있어서의 양송이 재배(栽培)에 최적(最適)한 환경조건(環境條件) 조절법분석(調節法分析)에 관(關)한 연구(硏究))

  • Lee, Eun Chol
    • Journal of Korean Society of Forest Science
    • /
    • v.9 no.1
    • /
    • pp.1-44
    • /
    • 1969
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demostrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental houses showed a sufficient heat insulation on effect to protect insides of the houses from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar houses to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on-ground type house, and (2) the solar heat generating system should be reconstructed properly. A trial solar heat generating system is shown in Fig. 40. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom houses. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that x is the outside temperature and y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between x and y can be expressed by the following regression lines. Underground iron pipe ventilation system ${\cdots}{\cdots}$ y=0.9x-12.8 Underground earthen pipe ventilation system ${\cdots}{\cdots}$y=0.96x-15.11 Vertical side wall ventilation system${\cdots}{\cdots}$ y=0.94x-17.57 5. The experimental results have shown that the relationships existing between the admitted and expelled air and the $Co_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 1) If it is assumed that x is an air speed cm/sec. and y is an expelled air speed in cm/sec. in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below: 2) If it is assumed that x is an admitted volume of air in $m^3/hr$ and y is an expelled volume of air in $m^3/hr$ in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below. 3) If it is assumed that the expelled air speed in cm/sec and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as x and y, respectively, since the y is a function of the x, the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}$ y=0.54X+0.84 4) If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as x, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as y, in a natural ventilation system, since the y is a function of the x the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}{\cdots}$ y=114.53-6.42x 5) If it is assumed that the expelled volume of air is shown as x and the $CO_2$ concentration which is expressed by multiplying 1000 times the actual of $CO_2$ % is shown as y in a natural ventilation system, since the y is a function of of the x, the relationships that exist between x and y can be expressed by the following exponent equation: G.E. (100%)-C.V. (50%) ventilation system${\cdots}{\cdots}$ $$y=127.18{\times}1.0093^{-X}$$ 6. The experimental results have shown that the ratios of the crass sectional area of the G.E. and C.V. vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: G.E. (admitting vent of the underground ventilation)${\cdots}{\cdots}$ 0.30-0.5% (controllable) C.V. (expelling vent of the ceiling ventilation)${\cdots}{\cdots}$ 0.8-1.0% (controllable) 7. Among several heating devices which were studied in the experiments, the hot-water boilor which was modified to be fitted both as hot-water toiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

Study on the Controlling Mechaniques of the Environmental Factors in the Mushroom Growing House in Chonnam Province (전남 지방에 있어서의 양송이 재배에 최적한 환경조건 조절법 분석에 관한 연구)

  • Chung, Byung-Jae;Lee, Eun-Chol
    • Journal of the Korean Wood Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.32-34
    • /
    • 1974
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demonstrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental house showed a sufficient heat insulation on effect to protect insides of the house from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar house to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on ground type house, and (2) the solar heat generating system should be reconstructed properly. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom house. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that X is the outside temperature and Y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between X and Y can be expressed by the following regression lines. Underground iron pipe ventilation system. Y=0.9X-12.8 Underground earthen pipe ventilation system. Y=0.96X-15.11 Vertical side wall ventilation system. Y=0.94X-17.57 5. The experimental results have 8hown that the relationships existing between the admitted and expelled air and the $CO_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 5.1 If it is assumed that X is an air speed cm/sec. and Y is an expelled air speed in cm/sec. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below: 5.2 If it IS assumed that X is an admitted volume of air in $m^3$/hr. and Y is an expelled volume of air in $m^3$/hr. in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the regression lines shown below. 5.3 If it is assumed that expelled air speed in emisec. and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as X and Y. respectively, since the Y is a function of the X. the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV (50%) ventilation system. Y=-0.54X+0.84 5.4 If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as X, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as Y, in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following regression line: GE(100%)-CV(50%) ventilation system. Y=114.53-6.42X 5.5 If it is assumed that the expelled volume of air is shown as X and the $CO_2$ concencration which is expressed by multiplying 1000 times the actual of $CO_2$% is shown as Y in a natural ventilation system, since the Y is a function of the X, the relationships that exist between X and Y can be expressed by the following exponent equation: GE(100%)-CV(50%) ventilation system. Y=$127.18{\times}1.0093^{-x}$ 5.6 The experimental results have shown that the ratios of the cross sectional area of the GE and CV vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: GE(admitting vent of the underground ventilation) 0.3-0.5% (controllable) CV(expelling vent of the ceiling ventilation) 0.8-1.0% (controllable) 6. Among several heating devices which were studied in the experiments, the hot-water boilor which wasmodified to be fitted both as hot-water boiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF