• Title/Summary/Keyword: Chongju

Search Result 778, Processing Time 0.027 seconds

Evaluation on the Environment Amelioration Functions of Green Spaces in Chongju City by GIS (지리정보체계를 이용한 청주시 녹지의 환청개선 기능 평가)

  • Koh, Kang Suk;Suh, Min Hwan;Kim, Jung Hyun;Kim, Kee Dae;Kil, Ji Hyun;Kim, Jeong Soo;Lee, Myung Woo
    • Journal of Environmental Impact Assessment
    • /
    • v.8 no.1
    • /
    • pp.51-59
    • /
    • 1999
  • This study was conducted to evaluate the functions of green spaces for the environment amelioration in Chongju City. The results obtained from this study were as follows; 1. Total amounts of $SO_2$ and $NO_2$ which can be absorbed by green spaces in Chongju City from EPA model were calculated as 27,655 tons and l,551 tons per year, respectively. 2. It was estimated that more green spaces were needed to mitigate the effect of air pollutants emitted from industrial complex at Songjung-Dong, Bokdae-Dong and Sachang-Dong in Chongju City. This is acquired as a result of overlaying the map of administrative district, forest state, and $SO_2$ isoline using GIS method. 3. The amounts of green spaces and the selection of their proper location have to be considered at the stage of city planning and in this case, the amounts of air pollutants are also considered.

  • PDF

A Presentation of Noise Removal Method for High Quality Communication in Multimedia Communication System (멀티미디어 통신시스템에서 고화질의 영상통신을 위한 잡음 제거 방법의 제안)

  • Cho, Dong-Uk;Baek, Seung-Jae;Hong, Sung-Won;Park, Jin-Soo;Kim, Dong-Won;Kim, Yong-Chan;Kim, Ji-Yeong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.04a
    • /
    • pp.654-658
    • /
    • 2000
  • 고효율의 멀티미디어 통신 서비스를 제공하기 위해 오류정정 능력이 뛰어난 채널코딩 기법과 차세대 통신 시스템에서 영상서비스는 그 데이터 양의 방대함으로 인해 효과적인 영상 압축 기법이 요구되고 있다. 또한 디지털 영상물의 저작권 보호(copyright protection)에 대한 디지털 워터마킹 기술이 중요한 현안이 되고 있다. 본 논문에서는 멀티미디어 통신 시스템에서 고화질의 영상을 보장하기 위한 채널 코딩기법을 제안하고자 한다. 이를 위해 연집오류를 산발 오류로 분포시킬 수 있는 새로운 인터리빙 방법의 제안과 터보 코드를 적용하여 채널상에서 발생하는 잡음을 제거하는 방법을 제안하고자 한다

  • PDF

Sampling and Analysis of Acidic Air Pollutants Using an Annular Denuder System during the Summer Season in Chongju City (디누더 측정기를 이용한 여름철 청주시의 산성오염물질 측정과 분석)

  • 이학성;강병욱
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.4
    • /
    • pp.441-448
    • /
    • 1996
  • The cyclone/annular denuder system/filter pack sampling system (ADS) was used to collect the acidic air pollutants in Chongju city. The data set was collected on nine different days with 24 hour sampling period from July 27 through August 27, 1995. The chemical species measured were $HNO_3, HNO_2, SO_2 and NH_3$ in the gas phase, and $PM_{2.5}(d_P<2.5 \mum), SO_4^{2-}, NO_3^- and NH_4^+$ in the particulate phase. Mean concentrations measured from this study were: $0.90 \mug/m^3 for HNO_3, 1.27 \mug/m^3 for HNO_2, 10.9 \mug/m^3 for SO_2, 4.82 \mug/m^3 for NH_3, 27.5 \mug/m^3 for PM_{2.5}, 5.24 \mug/m^3 for SO_4^{2-}, 1.22 \mug/m^3 for NO_3^-, and 1.64 \mug/m^3 for NH_4^+$. The fine particle $(PM_{2.5})$ mass measured for the ADS samples was slightly higher than the fine particle mass measured for the corresponding dichotomous sampler. For the wind coming from Chongju industrial complex the concentrations of acidic air pollutants measured were higher when compared with other directions. Specially, $SO_2 and PM_{2.5}$ concentrations for the wind coming from Chongju industrial complex were 3.6 and about 2 times, respectively, higher than those of other wind directions. High correlations were observed between $PM_{2.5} and fine particle's ion components $(r=0.82 with SO_4^{2-}, r=0.76 with NO_3^- and r=0.89 with NH_4^+). NH_4^+ and SO_4^{2-}$ was also highly correlated (r=0.97).

  • PDF

The Study on the Conservation According to Analysis of Composition of Canopied Landscape - A Case of Chongju Garosoo-gill- (관개경관 구도분석에 따른 보전방안에 관한 연구 - 청주 가로수길 중심으로 -)

  • Kwon Sang Zoon;Hong Young Rok
    • Journal of Environmental Science International
    • /
    • v.14 no.4
    • /
    • pp.379-387
    • /
    • 2005
  • This study aims to establish the schematic plan for renewing canopied landscape of Garosoo-gil of Chongju and to review to conserving the resources of streetscape of the Garosoo-gil. The study reinterpreted the Garosoo-gil of tree canopied road, representing meanings and functions of the road with main traffics as well as the image of Chongju city achieved buffer zone for open spaces to city green network. The study relied on the present composition, the status of road trees and streetscapes; additionally, the present streets cape was performed with examinations of those factors, the composition of roadscape, the change of structure according to visitor's movement and road construction condition, which was composed with focused places on concerning the loss and demolition of trees by Garosoo-gil. According to the result, the streetscape could be prospected to decreasing the number of trees and changing the sceneries of streetscape. As a result, the dominant canopied streetscape was found three areas. The analysis could help to find a way to establish the schematic plan for making the streets cape be symbolized and take place identified and better festival events with greens. The study could not only suggest the place of the streetscape to be divided into conservation area and protection area, for tree canopy but also establish alternatives for making the Garosoo-gil be a beautiful street park and enduring for a better landscape of main entrance road.

Implementation Of Client Management Database Program For Digital Hearing Aids Fitting System

  • Lee Gun Jae;Park Byoung Uk;Yoo Dong Gu;Kim Hack Yoon
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.755-758
    • /
    • 2004
  • A hearing aid performs the role of fitting in order to provide those with a hearing problem with a better hearing ability in ordinary circumstances. The existing Fitting system in the hearing aid is consisted somewhat complex, and simply performs the role of Fitting without any supervisions of those with a hearing problem. Such is these methods makes it unable to establish an organized supervision, and shows a problem in making high efficiency. In order to solve this problem mentioned as above, the based thesis have connected the Fitting program and the patient-management database program for the easy use by the user.

  • PDF

A Low Power UART Design by Using Clock-gating (클록 게이팅을 이용한 저전력 UART 설계)

  • Oh, Tae-Young;Song, Sung-Wan;Kim, Hi-Seok
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.865-868
    • /
    • 2005
  • This paper presents a Clock-gating technique that reduces power dissipation of the sequential circuits in the system. The Master Clock of a Clock-gating technique is formed by a quaternary variable. It uses the covering relationship between the triggering transition of the clock and the active cycles of various flip-flops to generate a slave clock for each flip-flop in the circuit. At current RTL designs flip-flop is acted by Master clock's triggering but the Slave Clock of Clock-gating technique doesn't occur trigger when external input conditions have not matched with a condition of logic table. We have applied our clocking technique to UART controller of 8bit microprocess

  • PDF

A study of defects of filtered-X LMS algorithm for modeling error (모델링오차에 따른 Filtered-X LMS 알고리즘의 오동작에 관한 고찰)

  • Park Byoung-Uk;Ko Byeong-Seob;Kim Hack-Yoon
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.359-362
    • /
    • 2000
  • ANC시스템에 있어서 현재 많이 이용되고있는 Filtered-X LMS 알고리즘에서 2차 음원과 제어점간의 임펄스응답은, 미리 동정하여 사용하는 것이 일반적이지만, 2차 음원과 제어점간의 전달특성이 이후에 변화할 경우, 실제의 전달함수와 적응에 이용한 전달함수간에 모델링 오차가 발생하게된다. 이 모델링 오차에 의하여 알고리즘은 오동작을 일으키고, 시스템은 불안정하게 되기도 한다. 따라서, 본 연구에서는 참조신호가 랜덤신호일 경우에 발생하는 모델링 오차와 Filtered-X LMS 알고리즘의 오동작에 관한 이론식을 도출하고, 시뮬레이션을 통하여 이를 입증하였다.

  • PDF

Estimation of Air Pollution by Lichens in Chongju (地衣類에 의한 精州市 大己汚染度 評價)

  • 김재한;강숙경
    • Journal of the Korean Geographical Society
    • /
    • v.36 no.3
    • /
    • pp.313-328
    • /
    • 2001
  • The lichen is generally used as a bio-indicator for the estimation of air pollution. The purpose of this research is to diagnose the level of air pollution by means of lichen Chongju region, relative to the direction of the dominant Wind(WNW) and the distance from the air pollution source. As a result it reveals that the industrial estate, its surroundings and inner city are confronting lichen desert phenomenon, According to the I.A.P index the average SO$_2$density in Chongju city in estimated above 0.03 ppm. However, the number of lichen species and its coverage are increased as the distance becomes further from the pollution source.

  • PDF

Influence on the PFC circuit with characteristics variation of MPP core (금속분말 코어의 특성변화가 PFC 회로에 미치는 영향)

  • Ju J.K.;Ahn T.Y.;Jang P.W;Jeong I.B.;Choi G.B.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.434-438
    • /
    • 2003
  • This paper present an investigation of the influence on the PFC(power factor correction) circuit with characteristics variation of MPP (Molybdenum permalloy powder) core. The experiment results of the 1.5kW class Boost converter for PFC rectifier with the average current mode control are evaluated to verify the influence on the PFC converter with inductance variation of the MPP core. As a results, it is shown that the ripple of the inductor using a MPP core increase with output power of the converter.

  • PDF

A differential capacitance deviation-to-time converter for triaxial position sensor (3축 위치 센서를 위한 차동 용량차-시간 변환기)

  • Won, Chang-Su;Chung, Won-Sup;Son, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.125-126
    • /
    • 2008
  • A differential capacitance deviation-to-time converter for interfacing position sensor is presented. It consists of triaxial position sensor, six comparators, six current mirrors, and control logic. The prototype differential capacitance deviation-to-time interval converter has been simulated using Chartered $0.35-{\mu}m$ CMOS parameters. The simulation results show that the maximum conversion time of the converter is $350{\mu}s$ and the linearity error is less than ${\pm}0.00l5%$.

  • PDF