• 제목/요약/키워드: Choice of Accelerator

검색결과 10건 처리시간 0.045초

Estimating Potential Value of Proton Accelerator in Korea Using Contingent Valuation Method

  • Jeong, Ki-Ho;Kim, Jun-Yeon
    • Journal of the Korean Data and Information Science Society
    • /
    • 제17권2호
    • /
    • pp.387-394
    • /
    • 2006
  • In Korea, a proton linear accelerator complex is being built as a part of the 21st Century Frontier Projects. Contingent valuation method (CVM) is a main evaluation method of nonmarket goods for which markets either do not exist at all or do exist only incompletely. This study shows the method can be applied to the benefit assessment of the proton accelerator complex. Using the discrete choice CVM method, this study estimates the willingness-to-pay (WTP) of a would-be user for the proton accelerator complex as 20,133 won per month.

  • PDF

스타트업의 액셀러레이터 선택 시 의사결정요인에 관한 연구 (Key Factors Affecting a Startup Entrepreneur's Choice of Accelerator)

  • 권용석;황보윤;이종훈
    • 벤처창업연구
    • /
    • 제14권1호
    • /
    • pp.33-46
    • /
    • 2019
  • 스타트업 생태계 활성화를 위한 액셀러레이터의 역할에 대한 큰 잠재력을 인정한 대한민국 정부는 2016년 일명 액셀러레이터법을 도입하였으며, 이에 힘입어 최근 등록된 액셀러레이터는 136개 수준으로 활성화 되었다. 액셀러레이터는 발원지인 미국뿐 아니라 유럽에서도 부흥하고 있는 등 세계적으로 주목받고 있지만 현재까지 액셀러레이터에 대한 선행 연구는 많지 않은 것이 사실이다. 국내에서는 액셀러레이터 법제화 이후에도 액셀러레이터의 연구는 극소수에 불과해 액셀러레이터에 대한 다양하고 심도 있는 학문적 연구가 필요한 상황이다. 스타트업과 액셀러레이터 간의 관계에 대한 객관적인 정보는 액셀러레이터를 통한 성공적인 스타트업 지원에 필수적이다. 아직 국내 액셀러레이터는 초기단계이므로 관련 연구나 사회적인 합의가 매우 부족한 실정이다. 특히, 스타트업이 액셀러레이터의 프로그램을 통해서 얻고자 하는 부분에 대한 명확한 정보는 보다 정교한 액셀러레이팅 프로그램 설계를 가능하게 하여, 지원받는 초기 스타트업들의 발전에도 도움이 될 것이다. 이에 따라, 본 연구에서는 판단분석기법을 활용하여 액셀러레이터의 지원이 필요한 단계에 있는 스타트업이 액셀러레이터를 선택 할 때 어떤 부분을 고려하는지에 대해서 알아보았다. 본 연구를 통해 스타트업이 액셀러레이터 선택 시 의사결정에 대한 합의와 액셀러레이터의 발전 방안을 제시하고자 하였다. 실증 분석 결과 스타트업이 액셀러레이터를 선택 시 의사결정요인에 가장 큰 영향을 미치는 요인은 후속 투자유치로 나타났다. 이는 초기 단계의 스타트업이 성장을 위해 가장 중시하는 요인을 투자라고 생각하며, 이를 액셀러레이터에 원한다는 것으로 해설할 수 있다. 이러한 연구결과가 국내 스타트업의 액셀러레이터 정책 수립과 관련 산업 활성화를 위한 방향 설정에 도움을 줄 수 있을 것으로 기대하며 본 연구와 함께 액셀러레이터와 관련한 후속 연구가 지속되길 기대한다.

양성자가속기시설의 편익분석 (Evaluating Proton Accelerator in Korea)

  • 정기호;조진삼;김지영;김준연
    • 자원ㆍ환경경제연구
    • /
    • 제15권4호
    • /
    • pp.741-760
    • /
    • 2006
  • 양성자기반공학기술개발사업은 과학기술부의 21세기 프론티어연구개발사업 중 하나로서 100MeV 20mA급의 선형 양성자가속기와 관련 부대시설을 2003년~2012년까지 건설하는 사업이다. 본 논문은 선택컨조인트모형을 이용하여 동 사업의 핵심 연구시설인 양성자가속기시설에 대한 편익을 분석하였다. 추정에 사용된 계량경제학모형은 다항로짓모형이며 이용편익을 측정하는 척도로는 Hicks의 보상변이가 사용되었다. 분석결과, 에너지용량 속성은 기준값인 100MeV에 비해 3GeV가 특히 가치가 떨어지며, 빔전류 크기 속성은 고려된 값들간에 특정한 선호의 차이가 없는 것으로 나타났다. 접근성 및 경비절약 속성에 대해서는 양성자가속기시설의 국내위치를 가장 선호하며, 이용자 편의시설과 기술지원팀 및 연구부대시설 속성의 경우는 많을수록 가치가 증대하는 것으로 나타났다. 시설이용요금은 부호가 음(-)으로 측정되어, 적을수록 가치가 증대하였다. 추정결과로부터 도출된 양성자가속기시설의 이용편익은 응답자당 약 193만 원/시간으로 계산되었다.

  • PDF

기관에 발생한 Adenoid Cystic Carcinoma 치험 1예 (A case of cystic carcinoma of the trachea)

  • 김송명
    • Journal of Chest Surgery
    • /
    • 제16권1호
    • /
    • pp.153-160
    • /
    • 1983
  • Adenoid cystic carcinoma is a rare primary tracheal tumor and this tumor behave slow growth, low-grade ma!ignancy, locally invasion and long-term host survival. Operation with the primary goal of complete excision is the treatment of choice but this tumor require excessive margins at surgical removal because of locally invasive cancer. A 45-years-old male patient had complained paroxysmal coughing from 1 year ago prior to admission and was diagnosed pre-operatively as endotracheal adenoma. He had been treated by operation, and combined with radiotherapy by 4 MeV. Lineal Accelerator. The tracheal mass was removed by tracheo-bronchotomy transpleurally and right total pneumonectomy was performed. There was post-operative course uneventfully and no post-operative complication. The patient Is free from cancer until post-operative 1 year clinically and alive with good healthy.

  • PDF

Thermal study of a scanning beam in granular flow target

  • Ping Lin;Yuanshuai Qin;Changwei Hao;Yuan Tian ;Jiangfeng Wan ;Huan Jia ;Lei Yang ;Wenshan Duan ;Han-Jie Cai ;Sheng Zhang
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4310-4321
    • /
    • 2022
  • The concept of dense granular-flow target (DGT) for the China Initiative Accelerator Driven Subcritical system (CiADS) is an attractive choice for high heat removal ability, low chemical toxicity, and radiotoxicity. A wobbling hollow beam is proposed to enhance the homogeneity of temperature rise of flowing particles in beam-target coupling zone. In this paper, the design procedure of target and beam parameters was discussed firstly. Then we simulated the heat deposition and transfer of the scanning beam in DGT to study the effect of beam parameters. The results show the flux density of proton beam plays a crucial role in the distribution of temperature rise while the contributions from scanning frequency heat transfer are also obvious. Moreover, heat transfer in transversal directions is insignificant, resulting in a low heat flux towards the sidewalls of DGT. This work not only contributes to the design of DGT, but also beneficial for understanding the beam-target coupling in porous materials.

Sharing Pathological Mechanisms of Insomnia and Osteoporosis, and a New Perspective on Safe Drug Choice

  • Yi, Sun Shin;Chung, Soo-Ho;Kim, Pan Soo
    • Journal of Menopausal Medicine
    • /
    • 제24권3호
    • /
    • pp.143-149
    • /
    • 2018
  • Lack of adequate sleep has become increasingly common in our 24/7 modern society. Reduced sleep has significant health consequences including metabolic and cardiovascular disorders, and mental problems including depression. In addition, although the increase in life expectancy has provided a dream of longevity to humans, the occurrence of osteoporosis is a big obstacle to this dream for both male and female. It is known that insomnia and bone health problems, which are very critical conditions in human life, interestingly, share a lot of pathogenesis in recent decades. Nevertheless, due to another side effects of the synthetic drugs being taken for the treatment of insomnia and osteoporosis, patients have substantial anxiety for the safety of drugs with therapeutic expectation. This review examines the pathogenesis shared by sleep and osteoporosis together and herbal medicine, which has recently been shown to be safe and efficacious in the treatment of both diseases other than synthetic drugs. We suggestions for how to treat osteoporosis. These efforts will be the first step toward enabling patients to have comfortable and safe prescriptions through a wide selection of therapeutic agents in the future.

6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교 (The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams)

  • 김회남
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.

  • PDF

만성골수성백혈병 15예의 비장조사 (Splenic Irradiation in Chronic Myeologenous Leukemia)

  • 오윤경;권형철;윤세철;박용휘;김춘추;김동집
    • Radiation Oncology Journal
    • /
    • 제3권2호
    • /
    • pp.137-144
    • /
    • 1985
  • 전신질환인 만성골수성백혈병(Chronic Myelogenous Leukemia: CML)에 있어서, 비장에만 국소적으로 방사선을 조사(Splenic Irradiation; SI)함으로써, 임상적 증상의 호전과 혈액소견상에 완해를 일으킨다는 것은 1903년대 이후로 알러져 있는 사실이다. 최근에 와서 Busulfan에 의한 화학요법이 주치료로서 도입되기 전까지는 SI가 CML치료에 광범위하게 사용되어 왔었다. 요즈음엔 비장의 방사선치료는 화학요법보다 그 결과가 좋지 못하지만, 통증을 동반한 비종대에서 증상의 완화를 위하거나, 가속기(accelerated phase)에 들어섰거나, 화학요법에 반응하지 않을 때 사용되고 있다. SI의 효과는 백혈구수의 감소, 헤모글로빈치의 상승등의 직접, 간접효과가 있으며 이 효과는 방사선치료를 끝낸 후에도 어느 기간 지속되며, 만족스런 반응을 보일 경우엔 반복치료도 시도되고 있다. 그리고 약물치료에 반응이 없었던 판자에서도 에로는 SI로 임상적 호전을 관찰할 수 있으며, SI전에 많은 치료를 받지 않았던 경우에 더 좋은 반응을 기대할 수 있음은 잘 알려져 있다. 가톨릭의대 방사선치료실에서는 화학요법도중 통증을 동반한 심한 비종대를 호소하거나, 화학요법에 반응이 없었던 15례의 CML환자에서 SI를 실시하였다. 저자들은 대상환자들의 SI전후의 임상적 증상, 이학적 소견 혈액학적 소견등의 변화 및 생존기간을 추적하였기에 문헌고찰과 함께 보고하는 바이다.

  • PDF

선형가속기의 소조사면에 대한 빔 자료 측정에서 검출기의 선량 특성 분석 (Dosimetric Characteristics of Detectors in Measurement of Beam Data for Small Fields of Linear Accelerator)

  • 구기래;양오남;임청환;최원식;신성수;안우상
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권3호
    • /
    • pp.265-273
    • /
    • 2012
  • 선형가속기를 기반으로 하는 세기조절방사선치료와 정위적방사선수술에서는 치료계획시스템의 소조사면에 대한 신뢰할만한 선량분포를 계산하기 위해서는 우선적으로 소조사면의 정확한 빔 자료 측정이 선행되어야 한다. 특히 소조사면의 빔 자료 측정에서 조사면 가장자리에서의 급격한 선량 변화, 측면 전자비평형, 그리고 검출기의 체적 영향으로 인한 적절한 검출기 선택이 중요하다. 따라서 본 연구에서는 선형가속기의 소조사면에 대한 빔 자료 측정에 있어서 검출기의 선량 특성을 알아보고자 하였다. 검출기는 0.01 cc 부피와 0.13 cc 부피의 이온전리함과 정위적다이오드를 사용하였으며, 빔 자료는 광자선(6 MV와 15 MV)에 대하여 조사면 크기를 $2{\times}2cm^2$에서 $5{\times}5cm^2$까지 변화시켜 각 검출기를 이용하여 깊이선량백분율, 선량출력계수, 그리고 빔측면도를 측정하였다. CC01 이온전리함과 정위적다이오드 검출기를 이용한 $PDD_{20}/PDD_{10}$$2{\times}2cm^2$ 조사면의 경우 6 MV와 15 MV에서 각각 1.02%와 0.12% 차이를 보였다. $3{\times}3cm^2$ 이상의 조사면에서는 각 검출기를 이용하여 얻어진 $PDD_{20}/PDD_{10}$의 차이가 6 MV와 15 MV에서 각각 평균 1.15%와 0.71% 이였다. CC01 이온전리함과 정위적다이오드 검출기를 이용한 선량출력계수 측정 결과, $2{\times}2cm^2$ 조사면의 경우 6 MV와 15 MV에서 0.5%와 1.5%이내에서 일치하였다. $3{\times}3cm^2$ 이상의 조사면에서는 각 검출기의 차이가 0.5% 이내이였다. 3개의 깊이에서 측정된 빔측면도의 반음영은 정위적다이오드 검출기의 경우 6 MV와 15 MV에서 각각 평균 2.7 mm와 3.5 mm, CC01 이온전리함의 경우 각각 평균 3.4 mm와 4.3 mm, CC13 이온전리함의 경우 각각 평균 5.2 mm와 6.1 mm이였다. 이를 통해 깊이선량백분율과 선량출력계수 측정 시 $2{\times}2cm^2$ 조사면에서는 CC01 이온전리함과 정위적다이오드 검출기를 $3{\times}3cm^2$에서 $5{\times}5cm^2$ 조사면에서는 각 검출기의 사용이 가능할 것으로 판단된다. 또한 소조사면에 대한 정확한 빔측면도의 반음영을 측정하기 위해서는 유효체적이 작은 CC01 이온전리함과 정위적다이오드 검출기 사용하는 것이 타당하겠다.

6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교 (The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams)

  • 김회남;박성용;서태석;권수일;윤세철
    • 한국의학물리학회지:의학물리
    • /
    • 제8권2호
    • /
    • pp.87-102
    • /
    • 1997
  • 목적 : 방사선량 측정시 에너지, 매질, 측정기 등의 측정 조건과 측정 프로토콜에 따라 절대 흡수선량값이 결정된다. 본 연구에서는 이러한 측정 조건의 변화와 측정 프로토콜의 차이에 따른 절대 선량 값을 구하여 비교 분석 하고자 한다. 방법 : 시멘스 선형가속기에서 발생하는 6MV 광자선을 이용하여 3개의 다른 매질(물, 고체 물팬텀, 폴리스틸렌팬텀)내에서 2개의 전리함 (PTW ion chamber, NEL ion chamber)과 2개의 전기계(Victoreen electrometer, Keithley electrometer)를 사용하여 흡수선량을 측정하였다. 매질, 전리함, 전기계등의 측정 조건을 달리하여 서로 다른 조합에 대한 측정값을 TG21, IAEA 프로토콜에 의해 각각 분석하였다. 결과 및 결론 : 2개의 전기계와 2개의 전리함 조합에 따른 TG2l 및 IAEA 의 Ngas,, ND값의 비는 평균적으로 1% 이내에서 일치하였다. 3개의 서로 다른 매질, 4개의 서로 다른 전리함 및 전기계 조합에 따른 12 가지 측정조건에 대한 흡수선량의 변화는 평균 0.6%의 차이를 보여 주였으며 임의의 전리함 및 전기계 조합에 대하여 물팬텀 및 고체물팬텀에 대한 TG21, MEA 측정법에 의한 흡수선량비의 변화 양상이 같은 양상을 보여주고 있으나 그 차이가 평균 1.96%를 보임으로서 고체물팬텀이 절대 흡수선량 측정에는 적절치 않은 것으로 사료된다. TG21 측정법에 따른 물팬텀과 폴리스틸렌팬텀을 이용한 절대 흡수선량값이 1.54%의 차이를 보임으로서 팬텀 매질에 대한 비교 factor가 필요할 것으로 사료된다. 측정매질, 전리함, 전기계 등의 여러 조건에 대한 흡수선량값의 차이가 TG21, IAEA 프로토콜에서 1% 이내의 차이를 보여 주고 있으며 상대적인 변화 양상이 측정법에 상관없이 같은 경향으로 변함으로서 측정조건이 측정법에 영향을 주지 않았음을 알 수 있다. 다만 표준 측정법을 사용할 때 팬텀에 의한 차이는 많이 날 수 있으므로 측정법에서 사용하는 표준 팬텀을 사용 할 것을 권장하며 이것이 어려운 경우는 병원에서 사용하는 팬텀에 대한 보정값을 자체적으로 구하여 사용하는 것이 오차를 줄일 수 있을 것으로 사료된다.

  • PDF