• Title/Summary/Keyword: Chlorofluorocarbon

Search Result 18, Processing Time 0.023 seconds

The Study on the Performance Characteristics of $NH_3$ Refrigeration System using a Shell and Tube Type Heat Exchanger

  • Hong Suck-Ju;Ha Ok-Nam;Kim Jae-Youl;Kwon Il-Wook;Lee Seung-Jae;Jeon Sang-Sin;Jeong Song-Tae;Ha Kyoung-Soo
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.4
    • /
    • pp.69-74
    • /
    • 2005
  • Nowadays CFC and HCFC refrigerants are restricted because they causes to depletion of ozone layer. Accordingly, an experiment is apply to the $NH_3$ gas for refrigerant to study the performance characteristic and to improve the energy efficiency. An experiment are carried out for the condensed pressure in a range from 14.5bar to 16bar and for degree of superheat in a range from 0 to $10^{\circ}C$ at each condensed pressure. As the result of experiment, when degree of superheat is $1^{\circ}C$ and condensed pressure is 14.5bar, the refrigeration system showed the high performance.

Groundwater Ages and Flow Paths at a Coastal Waste Repository Site in Korea, Based on Geochemical Characteristics and Numerical Modeling

  • Cheong, Jae-Yeol;Hamm, Se-Yeong;Koh, Dong-Chan;Lee, Chung-Mo;Ryu, Sang Min;Lee, Soo-Hyoung
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.1-13
    • /
    • 2016
  • Groundwater flow paths and groundwater ages at a radioactive waste repository located in a coastal area of South Korea were evaluated using the hydrochemical and hydrogeological characteristics of groundwater, surface water, rain water, and seawater, as well as by numerical modeling. The average groundwater travel time in the top layer of the model, evaluated by numerical modeling and groundwater age (34 years), approximately corresponds to the groundwater age obtained by chlorofluorocarbon (CFC)-12 analysis (26-34 years). The data suggest that the groundwater in wells in the study area originated up-gradient at distances of 140-230 m. Results of CFC analyses, along with seasonal variations in the δ18O and δD values of groundwater and the relationships between 222Rn concentrations and δ18O values and between 222Rn concentrations and δD values, indicate that groundwater recharge occurs in the summer rainy season and discharge occurs in the winter dry season. Additionally, a linear relationship between dissolved SiO2 concentrations and groundwater ages indicates that natural mineralization is affected by the dilution of groundwater recharge in the rainy summer season.

A Basic Study on Selection of Refrigeration Oils for R-134a Refrigerant (R-134a 냉매용 냉동기유 선정을 위한 기초 연구)

  • Na, B.C.;An, Y.J.;Han, D.C.;Chun, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.439-452
    • /
    • 1994
  • One of the chlorofluorocarbon compounds. R-12 deplete atmospheric ozone. It leads to international agreement to reduce CFC production. R-134a has similar thermodynamic properties to CFC-12. It has zero ODP(Ozone Depletion Potential). This Paper focuses on the lubricating oils for using with R-134a PAGs(Polyalkylene Glycol's) and esters are primary lubricants that are now being tested for use with R-134a Because of extreme polarity of R-134a. there are many problems in the selection of lubricating oil. This investigation analyzes compressor working conditions and calculates wear parts friction for simulation testing. Miscibility and material compatibility is proved by sealed glass tests. Friction was tested on the closed type pin on disk wear tester. This equipment simulates actual refrigerating compressor. Environment controlled test made more reliable result than field test Conventional oils(mineral oils, Alkylbenzene, PAO(Polyalpha Olefin) are immiscible with R-134a. PAGs and ester oils are miscible with R-134a. Friction coefficient is similar to conventional system(mineral oil/R-12 systems) at operating condition. At start & stop condition, PAGs/R-134a system has high friction coefficient. It provide reliable result on the lubricity, miscibility, material compatibility of R-134a with these new lubricants. It suggests proper selection of refrigeration oil that may improve compressor durability of performance.

  • PDF

Hydrate Phase Equilibria for the Gas Mixtures Containing HFC (수소불화탄소를 포함하는 혼합기체의 가스 하이드레이트 상평형)

  • Seo, Yong-Won;Lee, Seung-Min;Lee, Ju-Dong;Lee, Gang-Woo;Yamasaki, Akihiro;Kiyono, Fumio
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.581-584
    • /
    • 2007
  • (HFC(hydrofluorocarbon, 수소불화탄소)는 오존층 파괴 지수가 낮기 때문에 CFC(chlorofluorocarbon)의 대체 물질로 냉매와 발포제로 널리 사용되고 있는 물질이다. 하지만 HFC는 지구온난화 지수가 높은 기체이므로 대기중으로 방출되는 것을 막기 위해 분리/회수하여 재활용하는 것이 중요하다. 본 연구에서는 공기와 HFC의 혼합기체로부터 HFC만을 분리해 내는 방법으로 가스 하이드레이트 형성법을 제안하였다. 이 방법의 열역학적 타당성을 검증하기 위하여 질소+HFC-134a 혼합기체에 대하여 275-285 K의 온도 범위와 1-27 bar의 압력범위에 걸쳐서 가스 하이드레이트 상평형을 측정하였다. 질소는 가스 하이드레이트를 형성하기 위하여 0 $^{\circ}C$에서 150 bar 이상의 높은 압력이 필요한 반면 HFC-134a는 대기압에 가까운 낮은 압력이 필요하다. 두 기체의 평형 압력의 차가 크다는 것은 가스 하이드레이트 형성법을 이용할 경우 기체의 분리 효율이 매우 높다는 것을 나타낸다. 그리고, 본 실험을 통해서 얻어진 혼합기체의 하이드레이트상(H)-액상($L_W$)-기상(V)의 3상 평형선이 순수한 HFC-134a의 3상 평형선에 가깝게 위치하였다. 이는 가스 하이드레이트를 이용한 분리법이 낮은 압력에서 운전될 수 있음을 나타낸다. 이 분리법은 낮은 압력에서 운전되어 경제적일 뿐만 아니라 물 이외의 다른 매개체를 사용하지 않기 때문에 환경 친화적인 공정이라 할 수 있다.

  • PDF

Analysis of statistical models on temperature at the Seosan city in Korea (충청남도 서산시 기온의 통계적 모형 연구)

  • Lee, Hoonja
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.6
    • /
    • pp.1293-1300
    • /
    • 2014
  • The temperature data influences on various policies of the country. In this article, the autoregressive error (ARE) model has been considered for analyzing the monthly and seasonal temperature data at the northern part of the Chungcheong Namdo, Seosan monitoring site in Korea. In the ARE model, five meteorological variables, four greenhouse gas variables and five pollution variables are used as the explanatory variables for the temperature data set. The five meteorological variables are wind speed, rainfall, radiation, amount of cloud, and relative humidity. The four greenhouse gas variables are carbon dioxide ($CO_2$), methane ($CH_4$), nitrous oxide ($N_2O$), and chlorofluorocarbon ($CFC_{11}$). And the five air pollution explanatory variables are particulate matter ($PM_{10}$), sulfur dioxide ($SO_2$), nitrogen dioxide ($NO_2$), ozone ($O_3$), and carbon monoxide (CO). The result showed that the monthly ARE model explained about 39-63% for describing the temperature. However, the ARE model will be expected better when we add the more explanatory variables in the model.

Effects of Catalysts and Blowing Agents on the Physical Properties and Cell Morphology of Polyurethane Foams (폴리우레탄 폼의 물성과 Cell Morphology에 대한 촉매와 발포제의 영향)

  • Kwon, Hyun;Lee, Su Heon;Kim, Sang Bum;Bang, Moon-Soo;Kim, Youn Cheol
    • Applied Chemistry for Engineering
    • /
    • v.16 no.3
    • /
    • pp.379-384
    • /
    • 2005
  • Polyurethane foams (PUFs) were prepared from polymeric 4,4'-diphenylmethane diisocyanate (PMDI), seven polyols with different functionalities and OH values, silicone surfactant, two catalysts, and three blowing agents. Chlorofluorocarbon (CFC-11), hydrochlorofluorocarbon (HCFC-141b) and hydrofluorocarbon (HFC-365mfc) were used as blowing agents. The effect of gelling and blowing catalysts on basic properties and cell structure of PUF with HCFC-141b was investigated. The cell size of the PUF decreased with an increase in the amount of catalyst from 0 to 2 pph (parts per hundred polyol). In the case of gelling type catalyst, the compressive strength increased from 11.9 to $12.66kg_f/cm^2$ with an increase in the amount catalyst from 0 to 2 pph but the density did not change significantly. The gelling time, density, and compressive strength of the PUF with three different blowing agents were measured. There was no detectable change in their properties. However, the cell structure of PUF with HCFC-141b was not uniform as in the other systems.

Formulation of Alternative Non-Aqueous Cleaning Agents to Chlorofluorocarbon Compounds for Cleaning Flux, Solder and Grease (Flux, Solder 및 Grease 세정용 CFC 대체 비수계 세정제 배합 연구)

  • Jung, Young Woo;Lee, Ho Yeoul;Lee, Myoung Jin;Song, Ah Ram;Bae, Jae Heum
    • Clean Technology
    • /
    • v.12 no.4
    • /
    • pp.250-258
    • /
    • 2006
  • CFC compounds such as CFC-113 and 1,1,1-TCE, etc. have been used in various industries due to their excellent chemical stability, thermodynamic characteristics, non-inflammability and anti-corrosiveness. However, in oder to protect the earth environment, "the Montreal Protocol on substances that deplete the ozone layer" was adopted in 1989 for prevention of production and utilization of these CFC compounds and alternative cleaning agent have been required in the industry. The objective of this study is to develop non-aqueous cleaning agents that do not require major change of cleaning system, have excellent cleaning efficiency, are favorable to the environment, are harmless to the human body, and are not generated corrosive materials. In this work, non-aqueous cleaning agents have been formulated with glycol ether series and paraffinic hydrocarbon series with siloxane, and their physical properties and cleaning efficiencies were analyzed and compared with those of regulated materials. As a result of physical properties measurement of the formulated cleaning agents, it is expected that they may have good penetration ability into contaminated materials due to their properties with low density and low surface tension. Measurement of flash point and vapor pressure of the cleaning agents will be helpful for evaluation of their safety and working environment. The experimental results of cleaning flux, solder and grease by the formulated cleaning agents show that their cleaning abilities of soils were good and that there were no residues on the substance after cleaning. Therefore, alternative cleaning agents which have equivalent cleaning ability to regulating materials, good penetration ability and low hazard to human body, have been developed in this work.

  • PDF

A Study on Applicability of Hydrofluoroethers as CFC-Alternative Cleaning Agents (CFC 대체 산업세정제로의 HFEs의 적용가능성 연구)

  • Min, Hye-Jin;Shin, Jin-Ho;Bae, Jae-Heum;Kim, Hong-Gon;Lee, Hyun-Joo
    • Clean Technology
    • /
    • v.14 no.3
    • /
    • pp.184-192
    • /
    • 2008
  • Fluoride-type cleaning agents such as 2,2,2-trifluoroethanol (TFEA) and hydrofluoroethers (HFEs) do not destroy ozone in the stratosphere and have low global warming potential compared to hydrofluorocarbons(HFCs) and hydrochlorofluorocarbons (HCFCs). Especially, HFEs which have no flash point are paid attention as next generation type of cleaning agents for chlorofluorocarbons (CFCs) since they are safe in handling and have excellent penetration ability compared to hydrocarbon cleaning agents with low flash point. Here, the physical properties and cleaning abilities of fluoride-type cleaning agents such as TFEA, HFE-7100, HFE-7200, HFE-476mec, HFE-449mec-f, AE-3000 and AE-3100E and silicide-type cleaning agents such as trifluoroetoxytrimethylsilane (TFES) and hexamethyldisilazane (HMDS) were measured and compared with those of ozone destruction substances such as CFC-113 and 1,1,1-trichloroethane. They were also compared with toxic methylene chloride (MC) and isopropyl alcohol (IPA) which are now being used as an alternative cleaning agents. As a result, TFEA and HFEs had lower cleaning ability for removal of various soils compared to chloride-type cleaning agents, but they showed excellent cleaning ability fur fluoride-type soils. TFES and HMDS also showed excellent cleaning ability for silicide-type soils.

  • PDF