• 제목/요약/키워드: Chlorine residuals

검색결과 17건 처리시간 0.024초

배수관망의 잔류염소 평활화를 위한 최적 재염소 처리 (Optimal Rechlorination for the Regulation of Chlorine Residuals in Water Distribution Systems)

  • 윤재흥;오정우;최영송
    • 상하수도학회지
    • /
    • 제12권2호
    • /
    • pp.90-98
    • /
    • 1998
  • The optimal rechlorination in water distribution systems was investigated by incorporating optimization techniques into a numerical water quality model. For a hypothetical system that consists of 10 junctions including a storage tank and 12 links, the bulk ($k_b$) and pipe-wall ($k_w$) decay-rate constants of chlorine residual are assumed to be 2.0 1/day and 1.5 m/day, respectively. It was also assumed that the lower and upper limits of chlorine residual in the network are 0.2 mg/L and 0.6 mg/L. When the chlorine source is only the storage tank (without rechlorination), the high levels of chlorine residual appear near the storage tank to maintain the chlorine residuals above the lower limit over the junctions. On the other hand, the chlorine residuals in the network are distribute within the desirable range (0.2 - 0.6 mg/L) after the optimal rechlorination through five injection sites including the storage tank. In case of a real water distribution system that comprises 28 junctions including a clear well and 27 links, the bulk and pipe-wall decay-rate constants are 0.3 1/day and 0.2 m/day, respectively. Before rechlorination, the required chlorine residual at the clearwell is 5.1 mg/L to keep the chlorine residuals above the minimum level (0.6 mg/L) over the junctions. By the optimal rechlorination at five injection sites, the chlorine residuals are distributed within a desirable range of 0.6 mg/L through 2.0 mg/L, which can avoid the excess of chlorine residuals near the clear well. Consequently, total chlirine doses are decreased by 81% in the hypothetical distribution network and 69 % in the real distribution network for satisfying the minimum chlorine residuals.

  • PDF

대구 지역의 계절 변화에 따른 급수관내 잔류염소 농도 거동 (The Seasonal Variation of Free Chlorine Residuals by Water Supply Distance in Daegu)

  • 이태관
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.363-369
    • /
    • 2005
  • This paper presents the integrated technique of water quality analysis and Geographic Information System(GIS) for assessing the variation of free chlorine residuals by water temperature and supply distance in Sangri water supply system in Daegu. GIS was utilized for mapping projectmap, extraction of a pipeline route, and supply distance. Free chlorine residual is analyzed every month for appraising the seasonal variation. As a result, free chlorine residuals are affected both water temperature and water supply distance, and it becomes worse as water temperature and water supply distance is increased. To maintain 0.4mg/l of free chlorine residual, initial dose concentration should be over 1.85mg/l in summer.

Relationship between Bacterial Regrowth and Free chlorine Residuals in Water Distribution System

  • Lee, Yoon-Jin;Yoon, Tae-Ho;Jun, Byong-Ho;Oh, Kyoung-Doo;Nam, Sang-Ho
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2003년도 Challenges and Achievements in Environmental Health
    • /
    • pp.136-139
    • /
    • 2003
  • This study is to observe the occurrence of heterotrophic bacteria in terms of free chlorine residuals in two different water distribution system which belongs to both K and Y water treatment plant of S city of Korea. The data analyzing in distribution systems (DS) shows that the free chlorine residuals decrease from 0.10 to 0.56 mgmg/L for K, and 0.51 to 0.78 mg/L for Y. The decay of free chlorine is clearly higher in both March and August than those of in January. The HPC in DS are ranged from 0 to 40 CFU/mL for K, 0 to 270 CFU/mL for Y, on R2A medium. In particular, its level is relatively high at consumers ground storage tanks, taps and point-of-end area of Y. The predominant genera is studied in distribution systems are Acinetobacter, Sphingomonas (branch of Pseudomonas), Micrococcus, Bacillus, Staphylococcus. The diversity of heterotrophic bacteria increase in the end-point area. Most of them are either encapsulated cells or cocci of gram-positve. In conclusion, the point-of-end area in distribution systems shows the longer flow distance from water treatment plants, the greater diversity and higher level of heterotrophic bacteria due to the significant decay of free chlorine residuals.

  • PDF

Bacterial Regrowth in Water Distribution Systems and Its Relationship to the Water Quality: Case Study of Two Distribution Systems in Korea

  • Yoon, Tae-Ho;Lee, Yoon-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권2호
    • /
    • pp.262-267
    • /
    • 2004
  • This study was done to observe the occurrence of heterotrophic bacteria in terms of free chlorine residuals in two different water distribution systems, which belongs to both K and Y water treatment plant of S city in Korea. The data analyzed in the distribution systems show that the free chlorine residuals decreased from 0.10 to 0.56 mg/l for K, and 0.51 to 0.78 mg/l for Y. The decay of free chlorine is clearly higher in both March and August than in January. The HPC in the distribution systems are ranged from 0 to 40 cfu/ml for K, 0 to 270 cfu/ml for Y, on $R_2$A medium. In particular, its level is relatively high at the consumer's ground storage tanks, taps, and the point-of-end area of Y. The predominant genera that were studied in the distribution systems were Acinetobacter, Sphingomonas (branch of Pseudomonas), Micrococcus, Bacillus, Staphylococcus. The diversity of heterotrophic bacteria increases in the end-point area. Most of them are either encapsulated cells or of Gram-positve cocci. In conclusion, the point-of-end area in distribution systems shows the longer flow distance from the water treatment plants, along with a greater diversity and a higher level of heterotrophic bacteria, due to the significant decay of free chlorine residuals.

수돗물 배급수 계통의 유리잔류염소농도에 따른 종속영양세균의 거동에 관한 연구 (Heterotrophic Bacteria in Terms of Free Chlorine Residuals in water Distribution Systems)

  • 윤태호;이윤진;이옥재;이의광;김현;이동찬;남상호
    • 한국환경보건학회지
    • /
    • 제28권3호
    • /
    • pp.9-18
    • /
    • 2002
  • This study was to observe the occurrence of heterotrophic bacteria in terms of free chlorine residuals in two different water distribution systems belong to both K and Y water treatment plant. The data analyzed in this study showed that in distribution systems(DS), the free chlorine residuals were decreased from 0.10 to 0.56 ㎎/1 for K, and 0.51 and 0.78 ㎎/l for Y The decay of free chlorine were clearly higher in both March and August than those in January. The HPC in DS were ranged from 0 to 40 CFU/ml for K,0 to 270 CFU/ml for Y, on R2A medium. In particular, Its level was relatively high at consumers' ground storage tanks, taps and point-of-end area of Y, The predominant genera found in the distribution systems were Acinetobacter, Sphingomonas (branch of Pseudomonas), Microroccus, Bacillus, Staphylococcus. The diversity of heterotrophic bacteria was increased in the end-point area. Most of them were either encapsulated cells or cocci of gram-positve. In conclusion, the point-of-end area in distribution systems showed that the longer flow distance from WTP the greater diversity and higher level of heterotrophic bacteria due to the significant decay of free chlorine residuals.

흐름 주입 분석법에 의한 총 잔류염소의 정량 (Determination of Total Chlorine Residuals by Flow Injection Analysis)

  • 최용욱
    • 대한화학회지
    • /
    • 제43권4호
    • /
    • pp.430-437
    • /
    • 1999
  • 흐름주입 분석법(FIA)에 의한 간접 요오드화 UV 검출법으로 총 잔류염소를 신속하게 정량하는 방법을 연구하였다. FIA장치를 최적화하기 위해 용리액의 pH, 요오드화 이온의 농도, 혼합 및 반응코일의 길이,시료주입량 및 유속, 온도 및 검출파장에 대한 변화를 관찰하였다. pH 8.3에서 하이포아염소산 이온은 요오드화 이온을 선택적으로 산화시키고 자신은 염화이온으로 환원되었다. 방해이온을 제거하기 위한 가리움제로서 에틸렌다이아민이 가장 좋은 효율을 나타내었다. 하이포아염소산 이온의 검정곡선은 0.03-0.3 mg/L의 농도 범위에서 0.999이상의 직선성을 나타내었고, 검출한계는 0.007 mg/L이었다. 이러한 분석조건하에서 몇몇 전주근교 상수중 총 잔류염소의 농도를 정량하였다.

  • PDF

관로 내 적정소독능 확보를 위한 재염소 기법의 적용 (Application of Rechlorination for Adequate Disinfection Ability in Water Distribution System)

  • 이두진;김영일;이종민;정남정;김용운
    • 상하수도학회지
    • /
    • 제20권5호
    • /
    • pp.701-707
    • /
    • 2006
  • Disinfectant residual should be maintained to achieve biological stability during distribution of treated water. The wide distribution of retention times associated with storage and transport of water in a network and the reactivity of disinfectants make it difficult to maintain adequate residuals at critical locations. Rechlorination at some intermediate locations may reduce the total disinfectant dose while keeping residuals within specified limits throughout the water distribution system. In order to select the adequate location of rechlorination for achieving to maintain of residual chlorine throughout the distribution system, EPANET was used in this study. EPANET was well predicted chlorine transport and residual loss in the distribution system. Location of rechlorination was selected to maintain 0.4mg/L of residual chlorine throughout a water distribution system by field investigation and model simulation. The quantity of chlorine may reduced 36.7% and provided smooth residual between 0.42 and 0.60mg/L, when rechlorination would be used continuously at strategic location within the distribution system.

수온 변화에 따른 상수관망 내 수질반응계수 추정 및 월별 잔류염소농도 분포 변화 분석 (Assessment of temperature-dependent water quality reaction coefficients and monthly variability of residual chlorine in water distribution networks)

  • 정기문;최태호;강두선;이주원;황태문
    • 한국수자원학회논문집
    • /
    • 제56권11호
    • /
    • pp.705-720
    • /
    • 2023
  • 국내에서는 지속적인 상수도 수질사고 발생으로 인해 수돗물 수질에 대한 이용자 불신이 확산되고 있다. 특히, 수질사고 외에도 수돗물에 포함된 염소 성분 등으로 인해 맛, 냄새 등에 대한 이용자들의 수질민원 또한 지속적으로 발생하고 있다. 따라서 상수도 사업자들은 이용자에게 공급되는 잔류염소농도가 충분히 잔류하면서도 과도하게 유지되지 않도록, 시간적(Scheduling) 및 공간적(Rechlorination) 관점에서 상수관망 내 잔류염소농도가 균등하게 분포하도록 다양한 방법을 검토 및 적용하고 있다. 본 연구에서는 상수관망 해석을 통한 월별 잔류염소농도 최적 관리 방법의 일환으로, 대규모 상수관망시스템을 대상으로 Lab-scale 실험을 통한 수체반응계수, EPANET 수질해석을 통한 관체반응계수 등 관망 수질반응계 수를 온도별로 추정하고, 온도별 수질반응계수를 바탕으로 염소투입농도 조건에 따른 월별 잔류염소농도 분포 현황을 분석하였다. 분석 결과, 온도 조건이 달라짐에 따라 잔류염소농도 하한 및 상한기준을 만족시킬 수 있는 효율적인 염소투입농도 조건 또한 달라지므로, 월별 잔류염소농도의 공간적 분포를 고려하여 구체적이고 정량적인 염소투입 계획 수립이 필요한 것으로 판단된다.

Efficiency Comparison between Chlorine and Chlorine Dioxide to Control Bacterial Regrowth in Water Distribution System

  • Lee, Yoon-Jin
    • 한국환경보건학회지
    • /
    • 제32권4호
    • /
    • pp.282-291
    • /
    • 2006
  • This study investigated the inactivation of the total coliform, an indicator organism in chlorine and chlorine in order to control microbial regrowth for water distribution systems and select an appropriate disinfection strategy for drinking water systems. The disinfection effects of chlorine and chlorine dioxide with regard to the dosage of disinfectant, contact time and DOC was investigated experimentally. In spite of the consistency of chlorine residuals at approximately 0.2 mg/l, bacteria regrowth was detected in the distribution system and it was confirmed by the scanning electron microscope results. The influence of organic carbon change on the killing effect of chlorine dioxide was strong.