• Title/Summary/Keyword: Chlorine input system

Search Result 7, Processing Time 0.018 seconds

Design of Real Time Complex Proportion Method Automatic Chlorine Input System using RTOS (RTOS를 이용한 실시간 복합비례방식 자동 염소투입기 시스템 설계)

  • Kim, Si-Hwan;Lin, Chi-Ho
    • Journal of IKEEE
    • /
    • v.6 no.2 s.11
    • /
    • pp.146-151
    • /
    • 2002
  • This paper proposes a method that regulate a chlorine density to real time using RTOS. The most of a cleaning bed make use of the flux method to input chlorine. But, This method is difficult to control of chlorine's amount because Amount used of water is difference in each time or according to season. In this paper, we have designed a two method to flux and remain chlorine. Each task is programmed to cope with changeable external environment. The efficiency of the proposed system is shown by comparison results for performance of the proposal system with cleaning bed using a flux method.

  • PDF

Development of an Optimal Operation Model of Residual Chlorine Concentration in Water Supply System (송·배수시스템의 최적 잔류염소농도 관리 모델 개발)

  • Kim, Kibum;Hyung, Jinseok;Seo, Jeewon;Shin, Hwisu;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.6
    • /
    • pp.587-597
    • /
    • 2017
  • This study aimed to develop a method to optimize residual chlorine concentrations in the process of providing water supply. To this end, this study developed a model capable of optimizing the chlorine input into the clearwell in the purification plant and the optimal installation location of rechlorination facilities, and chlorine input. This study applied genetic algorithms finding the optimal point with appropriate residual chlorine concentrations and deriving a cost-optimal solution. The developed model was applied to SN purification plant supply area. As a result, it was possible to meet the target residual chlorine concentration with the minimum cost. Also, the optimal operation method in target area according to the water temperature and volume of supply was suggested. On the basis of the results, this study derived the most economical operational method of coping with water pollution in the process of providing water supply and satisfying the service level required by consumers in the aspects of cost effectiveness. It is considered possible to appropriately respond to increasing service level required by consumers in the future and to use the study results to establish an operational management plan in a short-term perspective.

Analysing the Effect of Residual Chlorine Equalization for Water Quality Improvement in Water Distribution System (공급과정 수질개선을 위한 잔류염소 균등화 효과분석)

  • Choi, Taeho;Lee, Doojin;Bae, Cheolho;Moon, Jiyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.587-596
    • /
    • 2016
  • This study attempts to draw factors for an analysis of the operation effect of a rechlorination facility and autodrain equipment for residual chlorine equalization by installing and operating a rechlorination facility and autodrain equipment in P City and analyzing the practical evaluation method and operation effect. For this purpose, this study selected three indicators for an analysis of the effectiveness of residual chlorine equalization and conducted a comparative analysis before and after the implementation of the residual chlorine equalization. As a result of estimation, (1) the reduction of the residual chlorine concentration range from a water treatment plant to the pipe end was 16.0%; (2) the total reduction of chlorination input was 18.0%; and (3) the reduction of the generation of disinfection by-products was 19.5%. In addition, this achieved enough residual chlorine equalization in the supply process and shows that it could successfully achieve the economic feasibility of investment in equipment and the reduction of the generation of disinfection by-products. Like this, it is judged that the three indicators suggested in this study will be used sufficiently as indicators of an analysis of the effectiveness of residual chlorine equalization according to the operations of the rechlorination facility and autodrain equipment.

A Study on Water Quality Management Methods of Waterscape Facilities in Accordance Legislation of Water Quality Criteria (수질기준 법제화에 따른 물놀이형 수경시설의 수질관리방안 연구)

  • Na, Kyung-Ho;Yong, Jeong-Ju;Kim, Ji-Soo;Byeon, Ju-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.4
    • /
    • pp.487-493
    • /
    • 2017
  • This study was conducted to propose measures of water quality management as the water criteria for waterscape facilities which have been highlighted as alternatives to wading pools in summer season was legislated. The number of public waterscape facilities has reached 290 sites in Gyeounggi province and 971 sites in South Korea in 2017. The water tank capacity of 80.3 % public waterscape facilities was less than $100m^3$. Facilities with disinfection system were only 6.5 % and facilities with filtration function were also very low at 6.9 %. Most of the waterscape facilities, about 93%, are expected to be vulnerable to complying with revised water quality criteria because they have to be disinfected by handling. Chlorine disinfectants, which are more persistent than ozone or ultraviolet sterilization methods, are more preferred. However, care should be taken when adding disinfectans because hypochlorous acid, which is an effective component of chlorine disinfectant, remains after the disinfection, but it is easily decomposed with time. For this study, ${\bigcirc}{\bigcirc}$ park floor fountain with a capacity of $63m^3$ was selected and the amount of free residual chlorine concentration was measured by injecting a certain amount of chlorine bleach. As a result, it took 5 hours to decrease from the water quality standard of 4 mg/L to 0.04 mg/L. If the waterscape facility is operated for 7 to 8 hours, the chlorine bleach should be re-injected after 5 hours. In addition, the problem of pH increase due to the input of chlorine disinfectant is expected, and the neutralization method using vinegar was proposed.

An Implementation of an Integrated Degasing System for Aluminum Molten Metal in Continuous Casting (알루미늄 연속주조 용탕의 탈 가스 일체화 장치 개발)

  • Lee, Yong-Joong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • There are some methods that have been used to manage a degasing process in recent years, such as an injection method that uses aluminum molten metal powder and chemicals supplier and input method that supplies argon and nitrogen, or chlorine gas by using a gas blow-tube. However, these methods show some problems, and it shows that it is a difficult process to handle, pollution due to producing a lot of toxic gases like chlorine and fluoride gas, irregular effects, and lowering work efficiency due to the excessive processing time. The problems that are the most fatal are the producing a lot of sludge due to the reaction of aluminum molten metal with chemicals, loss of metals, and decreasing the life of refractory materials. In order to solve these problems, this paper develops a technology that is related to aluminum continuous casting molten metal and monolithic degasing apparatus. A degasing apparatus developed in this study improved the existing methods and prevented environmental pollution with smokeless, odorless, and harmlessness by using a new method that applies argon and nitrogen gas in which the methods used in the West and Japan are eliminated. The method developed in this study decreases the molten metal processing and settling time compared to the existing methods and improves the workers' health, safety, and environment because there is no pollution in processes.

A Case Study on Chlorine Dioxide Usage at a Conventional Water Treatment Plant (기존 정수장 이산화염소 시범도입 사례연구)

  • Lee, Song-Hee;Lee, Byung-Doo;Kim, Jin-Keun;Seog, Kwon-Soo;Lee, Joung-Taek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.115-119
    • /
    • 2005
  • As the regulations on DBPs are tightened, many water treatment plants (WTPs) in Korea have already introduced or will introduce enhanced coagulation, alternative disinfectants and advanced treatments such as ozonization and granular activated carbon to improve drinking water qualify. After a phenol leakage accident at the Nakdong-River in 1991, 26 WIPs in Korea introduced carbon dioxide generators, but there has been no accumulation of significant operating data. This research summarizes things that should be considered for the introduction of carbon dioxide disinfection process to WTPs based on one year operation data from A WTP that has had high concentration of DBP during a specific period in the summer. The removal efficiency of DBP was $30{\sim}40%$, but those of 2-MIB, Geosmin were less than 10%. The generation rate of $ClO_2$ by-products such as chlorite and chlorate were $70{\sim}100%$ of input dosage, but the ratios increased over time. At the same time, strong chlorine odors may be produced in the distribution system when $ClO_2$ was used with $Cl_2$ as a result of reaction between the chlorite and residual chlorine.

Effects of the applications of excessive irrigation water and acetaldehyde on Chinese yam tubers at byobusan area of Aomori prefecture in Japan

  • Kawasaki, Michio;Keimatsu, Ryo;Endo, Akira
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.247-247
    • /
    • 2017
  • Byobusan area of Aomori prefecture in Japan was a marshy sand dune and had developed for agricultural land use with a large-scale sprinkler system. Recently, it becomes an agricultural problem at this area that distinctive damage with browning maculation and fissures frequently occurs in Chinese yam tubers. Acetaldehyde is one of the factor candidates of underground part damage in plants. In this study, incidence rate of the tuber damage, and the morphological character and elemental composition of the damage parts in tubers were investigated with applications of excessive irrigation water or acetaldehyde water solution into the yam field. The incidence rate of the distinctive tuber damage increased as the input amount of irrigation water was increased. At the browning maculation parts of the tubers, many fissures and damages of cork layer were observed under scanning electron microscopy. In addition, the periderm of tubers was significantly thicker in damaged parts than in non-damaged parts. Funguses, bacterium and nematodes were not observed in the damaged part under scanning electron microscopy. The weight ratio of each constituent element in an analyzed area relative to the total weight of major essential elements was measured with energy dispersive X-ray spectrometry. The results showed that the weight ratios of boron, carbon, phosphorus, sulfur and calcium were higher in damaged parts than in non-damaged parts whereas the weight ratios of oxygen and chlorine were lower in damaged parts than in non-damaged parts. It was also shown by this spectrometry that iron, cadmium, lead and zinc were not directly involved in occurrence of the tuber damage. In this study, there was no remarkable difference of tuber appearance between non-acetaldehyde and acetaldehyde application treatments. From the above results, it is shown that the damage would be a physiological disorder induced by the input of a large quantity of water in the sandy field.

  • PDF