• Title/Summary/Keyword: Chlorine effect

Search Result 369, Processing Time 0.027 seconds

Effect of Temperature on $H_2$ Spillover over $Pt/H_xMoO_3$ (Pt를 담지한 $H_xMoO_3$촉매의 수소 이동 속도에 미치는 온도의 영향)

  • 김진걸
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.2
    • /
    • pp.114-117
    • /
    • 2004
  • Rates of $H_2$ uptake into $Pt/MoO_3$ were measured for the noncalcined and $200^{\circ}C$ calcined $Pt/MoO_3$. Amount of $H_2$ uptake for $200^\circ{C}$calcined $Pt/MoO_3$ was greater than the amount of noncalcined $Pt/MoO_3$. From these two experiments, it was found that the rates of $H_2$ desorption were proportional to the increase of desorption temperature. XPS demonstrated that Cl reduced more faster in ITR after calcination at $200^{\circ}C$. This inducd smaller amount of residual chlorine at adlineation sites between Pt and $MoO_3$ substrates. This resulted in opening the more channel of hydrogen pathway into more $MoO_3$particles and controled the kinetics of hydrogen uptake.

  • PDF

Flow Characteristics Analyses within the Electrolysis Reactor using the CFD Simulation Technique (CFD 모사 기법을 이용한 전해반응기 내부 흐름 특성 분석)

  • Jeong, Jongsik;Lee, Seungjae;Lee, Jaebok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.6
    • /
    • pp.745-753
    • /
    • 2016
  • The objective of this study was to investigate design factors of the electrolysis reactor through the CFD(computational fluid dynamics) simulation technique. Analyses of velocity vector, streamline, chloride ion concentration distribution showed differences in flow characteristics between the plate type electrode and the porous plate type electrode. In case of the porous plate type electrode, chlorine gas bubbles generated from the anode made upward density flow with relatively constant velocity vectors. Electrolysis effect was more expected with the porous plate type electrode from the distribution of chloride ion concentration. The upper part of the electrolysis reactor with the porous plate type electrode had comparatively low chloride concentration because chloride was converted to the chlorine gas formation. Decreasing the size and increasing total area of rectifying holes in the upper part of cathodes, and widening the area of the rectifying holes in the lower part of cathodes could improve the circulation flow and the efficiency of electrolysis reactor.

Operating Conditions for Minimization of DBPs (Disinfection by-Products) in Drinking Water Supply System (소독부산물 최소화를 위한 운영조건 연구)

  • Shin, Hyung-Soon;Choi, Phil-Kweon;Kim, Jong-Su;Choi, Ill-Woo;Kim, Sang-Hoon;Kim, Tae-Hyun;Lee, Kyung-Hee;Lee, Soo-Moon;Jang, Eun-Ah;Jung, Yeon-Hoon;Kim, Jung-Yeol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.330-337
    • /
    • 2005
  • This study was carried out to propose the managemental improvement of the purification plants and the distribution facilities which can minimize the formation of disinfection by-products in drinking water distribution system. The disinfection by-products were highly created in the water treatment plant that the organic matters were high and the chlorine dosage was excessive. The concentration of DSPs was shown the highest value in August and the lowest value in December, because of temperature and pre-chlorine dosage effect. From the result of tracer test, the travel time from the treatment plant to the end of pipeline was around 3-4 days in summer, 5-6 days in winter, respectively, and the DSPs concentration of the reservoir(end of pipe) was 2-3 times higher than that of the beginning point. The improvement of the chlorination process and structural reformation of distribution facility was demanded to minimize the DSPs increase from purification plant to the end of pipe.

Development of the Smart Device for Real Time Water Quality Monitoring (실시간 수질 모니터링을 위한 스마트 디바이스의 개발)

  • Ryu, Dae-Hyun;Choi, Tae-Wan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.4
    • /
    • pp.723-728
    • /
    • 2019
  • Citizens' distrust of water pollution is very high in tap water that we routinely drink. In addition, water pollution accidents of tap water are difficult to predict and the risk is high, so real-time monitoring and management are needed. Therefore, it is necessary to introduce real-time water quality monitoring using the Internet of things(IoT). Residual chlorine is more persistent and economical than other disinfectants and it is easy to check residual effect, so it is mainly used as a disinfection index in waterworks. It can be monitored in real time by using IoT technology in order to secure the safety of tap water. In this study, we developed smart device for real-time water quality monitoring using amperometry sensor and analyzed its performance.

Electrogeneration of Hypochlorite Ions using a Dimensionally Stable Anode-Type (Ti/PtPd(10%)Ox) Electrode

  • Teresa Zayas;Miriam Vega;Guillermo Soriano-Moro;Anabella Handal;Miguel Morales;Leonardo Salgado
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.268-275
    • /
    • 2024
  • The study examined the electrogeneration of hypochlorite ions (ClO-) via electrolysis of aqueous NaCl solutions using a dimensionally stable anode-type (DSA-type) electrode based on platinum and palladium oxides supported on titanium mesh (Ti/PtPd(10%)Ox). The electrogenerated ClO- was quantified on the basis of the absorption band at 292 nm (Aλ = 292) of the UV-Vis spectrum. The effect of initial pH, concentration of NaCl, cell potential difference and electrolysis time were investigated in this study. The results showed that the electrolysis of aqueous NaCl solutions increases the solution pH up to high values (≥ 8.0) that favor the formation of ClO- over chlorine or hypochlorous acid. The hypochlorite concentration increases significantly at pH values > 7.0 and shows a linear trend with increasing NaCl concentration and with increasing cell potential difference. When the cell potential and NaCl concentration are held constant, the maximum hypochlorite value during electrolysis depends on both the cell potential and NaCl concentration. The Ti/PtPd(10%)Ox anode favors the production of hypochlorite ions, making this anode a promising material for use in electrochemical oxidation of wastewater via an indirect mechanism.

The effect of Laundry Detergents, Fabric Softeners, and Bleaches on Bactericidal Activities (의류용 세제와 섬유유연제 및 표백제가 미생물 제거에 미치는 영향)

  • 차옥선;최해운
    • Journal of the Korean Home Economics Association
    • /
    • v.37 no.4
    • /
    • pp.29-40
    • /
    • 1999
  • Effects of the commercial laundry detergents, fabric softeners, and bleaches on bactericidal activities were studied. Bactericidal activities under various conditions during washing, rinsing, and bleaching were evaluated in terms of minimum inhibitory concentration(MIC) by a broth dilution method. The experiments were carried out using Staphylococcus aureus and Escherichia coli which were usually employed in antibacterial activity tests. The results are summarized as follows : 1. All samples of Powder detergents(10 samples), soaps(7 samples) and fabric softeners(4 samples) were inactive against the Staphylococcus aureus and Escherichia coli. 2. One sample in the liquid detergents(6 samples) showed a very low MIC for Staphylococcus aureus and Escherichia coli., and three samples showed a selective effect for two bacterial strains. 3. Bleaching agent(containing peroxide) did not have bactericidal effect for Staphylococcus aureus and Escherichia coli. but the other(containing chlorine) had the effect for every bacterial strain in standard concentration. 4. All samples showed bactericidal effect above 60$^{\circ}C$.

  • PDF

Characterization of Gate Oxides with a Chlorine Incorporated $SiO_2/Si$ Interface (염소(Chlorine)가 도입된 $SiO_2/Si$ 계면을 가지는 게이트 산화막의 특성 분석)

  • Yu, Byoung-Gon;Lyu, Jong-Son;Roh, Tae-Moon;Nam, Kee-Soo
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.2
    • /
    • pp.188-198
    • /
    • 1993
  • We have developed a technique for growing thin oxides (6~10 nm) by the Last step TCA method. N-channel metal-oxide-semiconductor (n-MOS) capacitor and n-channel metal-oxide-semiconductor field-effect transistor's (MOSFET's) having a gate oxide with chlorine incorporated $SiO_2/Si$ interface have been analyzed by electrical measurements and physical methods, such as secondary ion mass spectrometry (SIMS) and electron spectroscopy for chemical analysis (ESCA). The gate oxide grown with the Last strp TCA method has good characteristics as follows: the electron mobility of the MOSFET's with the Last step TCA method was increased by about 7% and the defect density at the $SiO_2/Si$ interface decreases slightly compared with that with No TCA method. In reliability estimation, the breakdown field was 18 MV/cm, 0.6 MV/cm higher than that of the gate oxide with No TCA method, and the lifetime estimated by TDDB measurement was longer than 20 years. The device lifetime estimated from hot-carrier reliability was proven to be enhanced. As the results, the gate oxide having a $SiO_2/Si$ interface incorporated with chlorine has good characteristics. Our new technique of Last step TCA method may be used to improve the endurance and retention of MOSFET's and to alleviate the degradation of thin oxides in short-channel MOS devices.

  • PDF

Introduction to Electrochemical Quartz Crystal Microbalance Technique for Leaching Study of Metals (금속 침출연구를 위한 전기화학적 미소수정진동자저울 기술 소개)

  • Kim, Min-seuk;Chung, Kyeong Woo;Lee, Jae-chun
    • Resources Recycling
    • /
    • v.29 no.1
    • /
    • pp.25-34
    • /
    • 2020
  • Electrochemical Quartz Crystal microbalance is a tool that is capable of measuring nanogram-scale mass change on electrode surface. When applying alternating voltage to the quartz crystal with metal electrode formed on both sides, a resonant frequency by inverse piezoelectric effect depends on its thickness. The resonant frequency changes sensitively by mass change on its electrode surface; frequency increase with metal dissolution and decrease with metal deposition on the electrode surface. The relationship between resonant frequency and mass change is shown by Sauerbrey equation so that the mass change during metal dissolution can be measured in real time. Especially, it is effective in the case of reaction mechanism and rate studies accompanied by precipitation, volatilization, compound formation, etc. resulting in difficulties on ex-situ AA or ICP analysis. However, it should be carefully considered during EQCM experiments that temperature, viscosity, and hydraulic pressure of solution, and stress and surface roughness can affect on the resonant frequency. Application of EQCM was shown as a case study on leaching of platinum using aqueous chlorine for obtaining activation energy. A platinum electrode of quartz crystal oscillator with 1000 Å thickness exposed to solution was used as leaching sample. Electrogenerated chlorine as oxidant was purged and its concentration was controlled in hydrochloric acid solution. From the experimental results, platinum dissolution by chlorine is chemical reaction control with activation energy of 83.5 kJ/mol.

Bactericidal Effects of Food-borne Bacteria using Chlorine Dioxide and Electrolyzed Water (이산화염소수와 전해수를 이용한 식중독균의 살균효과)

  • Lee, Hye-Rin;Kim, Su-Jin;Bang, Woo-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.4
    • /
    • pp.232-237
    • /
    • 2022
  • The present study investigated the bactericidal effects of chlorine dioxide (CD) and electrolyzed water (EW) on pathogenic bacteria, such as Bacillus cereus, Staphylococcus aureus, Salmonella Typhimurium, and Escherichia coli O157:H7, by treatment them with CD and EW, respectively, for 0, 2, 4, 6, 8, and 10 min. Additionally, the sensitivities of Gram-positive (B. cereus and S. aureus) and Gram-negative (S. Typhimurium and E. coli O157:H7) to CD and EW were compared, respectively. In CD, the D-values for B. cereus, S. aureus, S. Typhimurium, and E. coli O157:H7 were 1.85±0.64, 2.06±0.85, 2.26±0.89, and 2.59±0.40 min, respectively. In EW, the D-values for B. cereus, S. aureus, S. Typhimurium, and E. coli O157:H7 were 2.13±0.32, 1.64±0.64, 1.71±0.32, and 1.86±0.36 min, respectively. All strains decreased consistently for 10 min in both CD and EW. However, the D-values of each bacterial species did not differ significantly between CD and EW (P>0.05). When comparing the bactericidal effect of CD and EW, no difference in D-value was observed, even though the pH and available chlorine concentration of CD were significantly lower than those of EW. These data could be used for the application of CD and EW in the food industry, considering characteristics such as the selection of optimal disinfectants, determination of optimal concentrations, and sensitivity to disinfection targets.

Effect of Chlorine Addition on Low Temperature $SiO_2$ Deposition (저온 이산화규소 증착시 도입된 염소 기체의 영향)

  • 박영배;이시우
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.S1
    • /
    • pp.157-161
    • /
    • 1995
  • 산화규소 증착 시 도입된 염소 기체는 저온부에서 수소기 감소에 효과적이었고, 증악 속도의 증가가 관찰되었다. 고온부에서는 증착속도가 감소하였고 막의 거칠기와 다공성이 증가 하였으며, 막내의 염소 잔존량이 감소함과 동시에 막은 불균일한 양론비를 나타내었다. 계면의 미결합은 모든 온도 범위에서 감소하였지만 염소 첨가량의 증가는 오히려 미결합을 증가 시키는 경향을 나타내었다. 계면의 미결합은 모든 온도 범위에서 감소하였지만 염소 첨가량의 증가는 오히려 미결합을 증가 시키는 경향을 나타내었다.

  • PDF