• 제목/요약/키워드: Chloride ions

검색결과 567건 처리시간 0.025초

A small-scale membrane electro-dialyser for domestic use

  • Chaalal, Omar;Hossain, Md.M.
    • Membrane and Water Treatment
    • /
    • 제6권1호
    • /
    • pp.43-52
    • /
    • 2015
  • A small-scale electro-dialysis system was constructed for domestic use. It is composed of six compartments in which five special polystyrene ionic membranes are housed. A series of experiments on the transport of sodium and chloride ions through polystyrene membranes was performed and the effects of electric current and voltage on the pH of water were investigated. This electrodialyser could reduce the NaCl content to an acceptable level (5307 mg/L) when water containing 9945 mg/L of sodium chloride is fed to the electrodialyser. The reduction was by the action of direct current 60 mA/100 mA when a 15 V / 20 V potential is maintained across the membrane. The results showed that the pH of the treated water attained a value in the range of 7-8, with the chloride concentration of 5307 mg/L when the voltage was in the range of 20 volts. This was achieved when two of the small-scale electro-dialysers were placed in series and the solutions from the respective compartments were mixed. This is considered useful because this complies to the requirement of drinking water standard both in terms of chloride and pH. Therefore, this type electrodialyserhas the potential for domestic uses in isolated houses where potable water supply is not available.

한라산 지역 용천수의 수리지화학적 특성 (Hydrogeochemical Characteristics of Spring Water in Halla Mountain Region, Cheju Island)

  • 윤정수;박상운
    • 한국지구과학회지
    • /
    • 제21권1호
    • /
    • pp.81-92
    • /
    • 2000
  • 본 연구는 한라산 지역에 분포하는 대표적인 9개 용천수에 대한 고도별 수질특성과 그 진화과정을 연구하였다. 조사 지역 9개 용천수의 수질분석결과 관음사용천수는 수소이온 농도에서 비정상적인 수질특성을 보였다. 해발고도 1000m 이하에 위치하는 영실, 남국선원, 성판악, 어리목 및 관음사용천수에서는 염소이온, 황산이온, 질산성질소 및 나트륨이온 함량이 높아 주변 육상오염원들에 의해 오염이 진행 중인 용천수로 분류된다. 중탄산이온, 황산이온 및 수소이온 농도는 강수량이 많았을 때 그 농도가 증가하였으며, 염소이온, 칼슘이온 및 질산성질소 농도는 강수량이 많았을 때 그 농도가 감소하였고, 마그네슘이온, 나트륨이온 및 전기비전도도 농도는 강수량의 영향이 미미하였다. 한라산 용천수는 백록담 담수와 윗세오름용천수를 제외한 전 용천수가 나트륨 또는 칼륨형(sodium or potassium type)과 중탄산형(bicarbonate type)의 용천수군으로 구분된다.

  • PDF

판형 열교환기 전열판의 부식 파손 분석 (Corrosion Failure Analysis of Flow Plate in Plate Heat Exchanger)

  • 송민지;최가현;채호병;김우철;김희산;김정구;이수열
    • Corrosion Science and Technology
    • /
    • 제20권4호
    • /
    • pp.204-209
    • /
    • 2021
  • Corrosion failure analysis of the flow plate, which is one of the accessories of the plate heat exchanger in a district heating system, was performed. The flow plate is made of 316 stainless steel, and water at different temperatures in the flow plate exchanges heat in a non-contact manner. The flow plate samples in which water mixing issues occurred were collected. Corrosion-induced pits, oxides, and contaminants were observed at locations where two plates are regularly in contact. The EDS analysis of the surface oxides and contaminants revealed that they were composed of carbon, silicon, and magnesium, which came from chemical adhesives. The IC/ICP analyses showed that the concentration of chloride ions was 30 ~ 40 ppm, which was not sufficient to cause corrosion of stainless steel. In the crevice, a local decrease in dissolved oxygen occurs along with an increase in chloride ions, thus forming an acidic environment. These environments destroyed the passive film of stainless steel, resulting in pits. Moreover, contaminants formed a narrower gap between the two metal plates and inhibited the diffusion of ions, thereby accelerating crevice corrosion.

식물추출액을 이용한 지반 고결제 개발 (Development of Soil Binder Using Plant Extracts)

  • 박성식;최선규;남인현
    • 한국지반공학회논문집
    • /
    • 제28권3호
    • /
    • pp.67-75
    • /
    • 2012
  • 본 연구에서는 식물추출액을 이용하여 모래 입자 사이에 친환경적으로 탄산칼슘을 석출시켜 모래 고결을 유발하고자 하였다. 식물추출액에는 고결유발 미생물(예: $Sporosarcina$ $pasteurii$)과 같이 요소를 탄산이온과 암모늄이온으로 분해하는 우레아제 성분이 포함되어 있다. 분해된 탄산이온과 용액 속에 녹아 있는 칼슘이온이 결합하여 탄산칼슘을 석출시키는 원리를 이용하여 모래의 고결을 유도하였다. 깨끗한 낙동강모래에 식물추출액과 요소 그리고 칼슘원(염화칼슘 또는 수산화칼슘)을 혼합한 용액을 섞어서 비빈 다음 다짐방법으로 공시체를 제작하였다. 요소의 농도를 세 종류로 달리하였으며, 제작된 공시체를 실내($18^{\circ}C$)에서 3일 동안 양생시킨 다음 일축압축시험과 SEM 및 XRD분석을 실시하여 사질토의 고결 정도를 연구하였다. 칼슘원에 관계없이 요소의 농도가 높을수록 탄산칼슘이 더 많이 침전되어 일축압축강도는 식물추출액을 사용하지 않은 경우보다 최대 10배까지 증가하는 경향을 보였다. 염화칼슘을 사용한 공시체가 수산화칼슘을 사용한 경우보다 더 높은 강도를 나타내었다.

전기화학적 임피던스법에 의한 철근콘크리트의 부식연구 (Studies on the Concrete Reinforcement Corrosion by Electrochemical Impedance Spectroscopy)

  • 강태혁;조원일;조병원;주재백;윤경석
    • 공업화학
    • /
    • 제9권6호
    • /
    • pp.907-913
    • /
    • 1998
  • 전기화학적 임피던스법(electrochemical impedance spectroscopy, EIS)을 사용하여 염소이온에 의한 철근 콘크리트의 부식현상을 연구하였다. 콘크리트를 만들 때 물에 용해된 상태의 염소이온은 콘크리트 내부에 존재하게 되며, 이 염소이온의 농도를 변화시키며 실험을 수행하였다. 재령 400일 이상 EIS법으로 측정한 결과, 세밀한 전기화학적 등가회로 및 물리적 모델을 구성하였으며, 얻어진 임피던스 파라미터로부터 철근 콘크리트의부식현상을 물리적 모델로 설명할 수 있었다. 실험에서 얻은 측정값과 CNLS(complex nonlinear least squares) fitting법으로 구한 값은 잘 일치하였으며, 모델로부터 얻어진 임피던스 상수를 이용하여 부식 속도를 계산할 수 있어 이를 통한 부식 속도 예측이 가능함을 알 수 있었다.

  • PDF

제주도 동부지역 지하수의 염수화에 관한 연구 (Study on The Salinization in Groundwater of the Eastern Area of Cheju Island)

  • 김지영;오윤근;류성필
    • 한국환경과학회지
    • /
    • 제10권1호
    • /
    • pp.47-58
    • /
    • 2001
  • According to the results of the groundwater quality investigation about 230 holes all over the country, the groundwater which was in excess of standard grows larger every year and closed holes increased to 23,457 holes in 1997 from 15,724 holes in 1996. This is the major reasons that water quality contamination, shortage of water quantity, increasing of salinity and so on. There are 7 groundwater salinization sources which are condisered as most important on a regional level. And among theses the Cheju Island groundwater salinization sources are (1) halite solution, (2) natural saline groundwater, (3) sea-water intrusion. The method of taking an isotopes is one of research methods of the origin of groundwater salinization and is used in so many studies because it has very high confidence. $^{18O}O, ^2H, ^3H, ^{14}C$ and so on in an isotopes are frequently used in the method of them. Consequently on this study we analyzed major ions and $^3H$ in groundwater, sea-water and rain of the eastern part of cheju island known as contaminated site from long time ago to examine the origin of groundwater salinization. Relation ratios of the major ions versus chloride ion shows similar tendency to sea-water. This indicates that sea-water entered the groundwater layer. And amount of $^3H$ in holes of the land side is higher than of the sea side. Relation of chloride ion versus $^3$H indicates negative character. Therefore we can think that the reason of groundwater salinization of this part is natural saline groundwater and halite solution by relation.

  • PDF

해양 콘크리트구조물의 철근부식 모니터링을 위한 매크로셀 센서 시스템의 적용 (Application of Macrocell Sensor System for Monitoring of Steel Corrosion in Concrete Structure Exposed to Marine Environment)

  • 이승태;문대중;김완종;문재흠;김학수
    • 한국해안·해양공학회논문집
    • /
    • 제22권4호
    • /
    • pp.241-247
    • /
    • 2010
  • 철근부식은 해양 콘크리트 구조물의 내구성능을 저하시키는 가장 중요한 인자 중 하나이다. 본 논문은 해양환경에 노출된 콘크리트 구조물의 부식거동을 평가하기 위하여 매크로셀 센서 기법 중 하나인 anode-ladder-system의 적용성을 평가한 것이다. 해양환경으로부터 유입되는 염화물의 침투, 확산에 의한 철근부식 위험성에 노출되어 있는 철근콘크리트 구조물의 전위 및 전류를 측정하여 철근의 부식거동을 정성적으로 평가하였다. 부식 모니터링 센서는 평균 해수면으로부터 각각 3.7, 6.0 및 8.2 m 높이에 매설하였으며, 애노드 단자의 부식특성은 평균해수면의 거리에 따라 다르게 거동함을 확인하였다. 또, migration 실험을 통하여 콘크리트 강도와 확산거동과의 관계를 고찰하였다. 결론적으로, 해양 콘크리트 구조물의 부식을 방지 및 완화하기 위해서는 적절한 콘크리트 피복두께의 확보 및 초기 콘크리트의 품질 개선이 중요한 것으로 조사되었다.

$CuCl_2-NiCl_2-CoCl_2$용액으로부터 Alamine336과 LIX84에 의한 구리의 용매추출 (Solvent Extraction of Copper from $CuCl_2-NiCl_2-CoCl_2$ Solutions by Alamine336 and LIX84)

  • 이만승;안종관;안재우
    • 자원리싸이클링
    • /
    • 제11권6호
    • /
    • pp.12-17
    • /
    • 2002
  • $CuCl_2$-$NiCl_2$-$CoCl_2$용액으로부터 구리를 분리하기 위해 추출제로 Alamine336과 LIX84를 사용하여 추출실험을 하였다. 염산용액에서 Alamine336과 LIX84에 의한 구리, 코발트, 니켈의 분배계수와 구리의 분리계수는 금속이온과 염소이온간에 형성되는 착물의 농도에 큰 영향을 받았다. 염소이온농도가 0.5에서 4.0M사이인 용액에서 코발트로부터 구리의 분리성은 LIX84가 Alamine336보다 우수하였다. 염소이온농도가 1.0M인 용액에서 LIX84와 Alamine336의 부피백분율을 5에서 40%까지 변화시켜 추출한 결과 LIX84로 추출하는 경우 Alamine336에 비해 더 높은 구리의 분리계수를 얻었다.

Pseudomonas spp.의 원형질체 생성과 재생 (The Spheroplast Formation and Regeneration of Pseudomonas spp.)

  • 이주실;이영록
    • 미생물학회지
    • /
    • 제24권1호
    • /
    • pp.24-31
    • /
    • 1986
  • Pseudomonas 속에 속하는 여러균주의 원형질체 생성을 위한 최적조건과 이들의 재생에 영향을 미치는 몇 가지 요인들을 조사하였다. Pseudomonas는 lysozyme ($100{\mu}g/ml$)과 10mM EDTA를 처리하였을 때 99.0%에서 99.9%까지 원형침체로 천환 되었으며, 이때 사용한 완충액의 최적 pH는 8.0이였고 효소처리는 상온에서 진탕하지 않고 처리하였을 때가 비교적 균주간에 차이가 없이 효과적으로 원형질체가 생성되었다. $MgCl_{2}$ 그러고 Streptomycin수용액이 윈형 질체의 안정성을 높였고, 원형질체의 생성에는 $Mg^+\;and\;Na^+$ 이온이 효과적으로 작용하였다. 원형질체의 재생은 Rich Regeneration Medium배지에 20mM $MgCl_{2}$를 첨가하였을 때 원형질체의 재생율이 28배까지 증가하였다. 원형질체의 생성과 그것을 희석하는데 사용한 완충액에 1% Bovine Serum Albumlne를 첨가한 경우 재생율이 10배 가까이 증가되었고, 또한 완충액에 1% BSA를 첨가하고 재생배지에 0.5% 제라틴을 첨가했을 때에는 14배까지 재생율이 증가되어다.

  • PDF

이온크로마토그래피를 활용한 무기산류 정도관리 방법 연구 (A Study on Quality Control of Inorganic Acids using Ion Chromatograph)

  • 박해동;박승현;정기효
    • 한국산업보건학회지
    • /
    • 제31권1호
    • /
    • pp.22-30
    • /
    • 2021
  • Objectives: The objectives of this study were to develop a quality control protocol of inorganic acids using ion chromatograph and to evaluate analytical proficiency of the legally designated agencies. Methods: This study prepared inorganic acid samples by injecting three anion certified solutions (chloride, nitrate, and sulfate) on the quartz filters. To investigate the storage stability and concentration consistency of the samples, 240 samples for each anion were tested at weeks 0, 2, 4, 8, 12, and 16 while storing at 4℃ and 25℃. To evaluate analytical proficiency, two separate testings were administrated for six skilled analysts and 46 analysts affiliated with legally designated agencies. Results: Average recoveries of the three ions after 16 weeks of storage were fairly high (over 95%). In addition, average recoveries (chloride = 97%, nitrate = 96%, and sulfate = 103%) after 16 weeks of storage at low temperate were relatively higher than those (94%, 93%, and 98%) at room temperature. The coefficients of variation (CV) for the three ions were less than 5% except for the sulfate sample at 5.56 ㎍ (CV = 12.4%). The average ratios of the concentration values analyzed by the legally designated agencies to the injected concentrations were close to 1. However, their CVs were relatively greater (chloride ≤ 49%, nitrate ≤ 14%, and sulfate ≤ 28%), which implies a need for quality control. Conclusions: The quality control protocol used in this study for the three inorganic acids can be utilized in the quality control for ion chromatography.