• Title/Summary/Keyword: Chloride Diffusion Coefficient

Search Result 270, Processing Time 0.025 seconds

Chloride Ion Diffusion Characteristics of Fly ash. Concrete with Age (재령에 따른 플라이 애쉬 콘크리트의 염소이온 확산특성)

  • 이재호;이광명;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.681-686
    • /
    • 2003
  • One of the major degradation processes of reinforced concrete (RC) structure is corrosion of reinforced steel due to chloride attack. Severe environments, such as marine environment and exposure to de-icing salts, could accelerate the steel corrosion of RC structures through the chloride ion intrusion into concrete. In order to delay this degradation process, several kinds of admixtures have been used in concrete mix. In this study, effective diffusion coefficient of chloride ion ($D_{eff}$) and total passed charge of concrete with and without fly ash were measured using electrical method. It is found that fly ash concrete has much less chloride ion coefficient than ordinary concrete at later age. By analyzing the test results, $D_{eff}$ at 28 and 90 days was obtained as a function of water-binder ratio (W/B) and an equation for predicting $D_{eff}$ with age was proposed considering the decreasing rate of $D_{eff}$.

  • PDF

Effect of Latex on Corrosion Resistance of Steel Rebar in Concrete (콘크리트 내에서 보강철근의 부식저항성에 미치는 라텍스의 효과)

  • Park, Sung-Ki;Won, Jong-Pil;Sung, Sang-Kyung;Park, Chan-Gi
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.409-412
    • /
    • 2008
  • This study were evaluated the corrosion threshold reached at steel reinforcement in latex modified concrete(LMC). Accelerated testing was accomplished to the evalate the diffusion coefficient of LMC mix, and the time dependent constants of diffusion. Also, average chloride diffusion coefficient was estimated. From the average chloride ion diffusion coefficient, the time which critical chloride contents at depth of reinforcement steel was estimated. Test results indicated that the corrosion threshold reached at reinforcement in LMC are effected on the mix proportion factor including latex content, and water-cement ratio.

  • PDF

Strength and Resistance to Chloride Penetration in Concrete Containing GGBFS with Ages (GGBFS를 혼입한 콘크리트의 재령에 따른 강도 및 염소이온 침투 저항성)

  • Park, Jae-Sung;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.3
    • /
    • pp.307-314
    • /
    • 2017
  • Concrete is a durable and cost-benefit construction material, however performance degradation occurs due to steel corrosion exposed to chloride attack. Penetration of chloride ion usually decreases due to hydrates formation and reduction of pores, and the reduced chloride behavior is considered through decreasing diffusion coefficient with time. In the work, HPC (High Performance Concrete) samples are prepared with 3 levels of W/B (water to binder) ratios of 0.37, 0.42, and 0.27 and 3 levels of replacement ratios of 0%, 30% and 50%. Several tests containing chloride diffusion coefficient, passed charge, and compressive strength are performed considering age effect of 28 days and 180 days. Chloride diffusion is more reduced in OPC concrete with lower W/B ratio and GGBFS concrete with 50% replacement ratio shows significant reduction of chloride diffusion in higher W/B ratio. At the age of 28 days, GGBFS concrete with 50% replacement ratio shows more rapid reduction of chloride diffusion than strength development, which reveals that abundant GGBFS replacement has effective resistance to chloride penetration even in the early-aged condition.

Evaluation of Chloride Diffusion Characteristics in Concrete with Fly Ash Cured for 2 Years (2년 양생된 Fly Ash 콘크리트의 염화물 확산 특성 평가)

  • Yoon, Yong-Sik;Hwang, Sang-Hyeon;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.1
    • /
    • pp.8-15
    • /
    • 2019
  • When RC(Reinforced Concrete) structures are exposed to harsh environment, deterioration phenomenon occurs, and the corrosion in rebar due to chloride intrusion is known as representative deterioration, so called chloride attack. In this paper, chloride resistance performance of 2 years aged concrete is evaluated considering 3 levels of water to binder ratio(0.37, 0.42, and 0.47) and 2 levels of substitution ratio of fly ash(0% and 30%). Accelerated chloride diffusion coefficient tests referred to Tang's method, total passed charge tests referred to ASTM C 1202, and compressive strength tests referred to KS F 2405 are performed. With adaptation of the previous test results and the results from this study, time-dependent chloride diffusion characteristics are analyzed for each concrete. The FA(Fly Ash) concrete has higher chloride resistance performance than OPC(Ordinary Portland Cement) concrete. According to the evaluation standard of ASTM C 1202, the FA concrete has "Moderate" grade after 49 days while OPC concrete does "Moderate" grade after 365 days. As the results of time-parameter for chloride diffusion, OPC concrete and FA concrete show the decreasing behavior of time-parameters with increasing water to binder ratio. Also, FA concrete has 1.57~2.74 times of time-parameter than OPC concrete. That's cause is thought that the time-parameter indicates the gradient of decreasing of diffusion coefficient. FA concrete has higher time-parameters than OPC concrete by pozzolanic reaction of FA.

Correlation between chloride-induced corrosion initiation and time to cover cracking in RC Structures

  • Hosseini, Seyed Abbas;Shabakhty, Naser;Mahini, Seyed Saeed
    • Structural Engineering and Mechanics
    • /
    • v.56 no.2
    • /
    • pp.257-273
    • /
    • 2015
  • Numerical value of correlation between effective parameters in the strength of a structure is as important as its stochastic properties in determining the safety of the structure. In this article investigation is made about the variation of coefficient of correlation between effective parameters in corrosion initiation time of reinforcement and the time of concrete cover cracking in reinforced concrete (RC) structures. Presence of many parameters and also error in measurement of these parameters results in uncertainty in determination of corrosion initiation and the time to crack initiation. In this paper, assuming diffusion process as chloride ingress mechanism in RC structures and considering random properties of effective parameters in this model, correlation between input parameters and predicted time to corrosion is calculated using the Monte Carlo (MC) random sampling. Results show the linear correlation between corrosion initiation time and effective input parameters increases with increasing uncertainty in the input parameters. Diffusion coefficient, concrete cover, surface chloride concentration and threshold chloride concentration have the highest correlation coefficient respectively. Also the uncertainty in the concrete cover has the greatest impact on the coefficient of correlation of corrosion initiation time and the time of crack initiation due to the corrosion phenomenon.

Concrete mix design for service life of RC structures exposed to chloride attack

  • Kwon, Seung-Jun;Kim, Sang-Chel
    • Computers and Concrete
    • /
    • v.10 no.6
    • /
    • pp.587-607
    • /
    • 2012
  • The purpose of this research is to propose a design technique of concrete mix proportions satisfying service life through genetic algorithm (GA) and neural network (NN). For this, thirty mix proportions and the related diffusion coefficients in high performance concrete are analyzed and fitness function for diffusion coefficient is obtained considering mix components like w/b (water to binder ratio), cement content, mineral admixture (slag, flay ash and silica fume) content, sand and coarse aggregate content. Through averaging the results of 10 times GA simulations, relative errors to the previous data decrease lower than 5.0% and the simulated mix proportions are verified with the experimental results. Assuming the durability design parameters, intended diffusion coefficient for intended service life is derived and mix proportions satisfying the service life are obtained. Among the mix proportions, the most optimized case which satisfies required concrete strength and the lowest cost is selected through GA algorithm. The proposed technique would be improved with the enhancement of comprehensive data set including wider the range of diffusion coefficients.

Corrosion Prediction of a Cement Mortar-Grouted Rockbolt by Measuring Its Chloride Diffusion Coefficient (시멘트 모르타르계 록볼트 충전재의 염화물 확산계수 측정을 통한 록볼트 부식 예측)

  • Bae, Gyu-Jin;Chang, Soo-Ho;Kim, Dong-Gyou;Park, Hae-Geun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.3
    • /
    • pp.259-271
    • /
    • 2006
  • This paper aims to predict the corrosion of a fully cement-grouted rockbolt induced by chloride diffusion in a cement mortar grout. From the viewpoint of the long-term durability, a rockbolt may be deteriorated by chemical components, such as sulphate and chloride, in groundwater. Especially, the steel rod of a rockbolt is corroded mainly by chloride. The rockbolt corrosion results in the volume expansion of a rod and then the cracking of a cement grout. In this study, the chloride diffusion coefficient of a cement mortar grout was used to evaluate the possibility of rockbolt corrosion by chloride, and to predict the long-term durability of a rockbolt. The electric acceleration test method was adopted to measure the chloride diffusion coefficient. In addition, a simple pullout testing system was newly proposed to measure the pullout capacity of a rockbolt more easily in a laboratory condition. From the experiments, it was showed that the chloride could diffuse in the cement grout more easily than in ordinary concrete materials. As a result, it was considered that a rockbolt might be easily corroded in a short term by the diffusion of chemical components with high concentration, although it was fully grouted.

Experimental Study on the Relationship between Time-Dependent Chloride Diffusion Coefficient and Compressive Strength (시간의존성 염화물 확산계수와 압축강도 상관성에 대한 실험적 연구)

  • Lee, Seung-Hoon;Kwon, Seung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.715-726
    • /
    • 2012
  • Since strength and diffusion coefficient of concrete, representative concrete properties that in change with age, the time effect must be considered in the analysis of chloride penetration. In this study, an evaluation of correlation between accelerated diffusion coefficient, apparent diffusion coefficient, and compressive strength in high performance concrete with various mineral admixtures such as ground granulated blast furnace slag, fly ash, and silica fume was performed. For this work, thirty mix proportions were prepared. Accelerated diffusion coefficients at the age of 28, 91, 180, and 270 days were evaluated. For apparent diffusion coefficient, submerging test for 6 months was performed. For evaluation of compressive strength with ages, the compressive strength test was carried out at an age of 7, 28, 91, 180 days. The results of accelerated diffusion coefficient, apparent diffusion coefficient, and strength were compared, and the correlation was analyzed considering time dependency. From this study, linear relationship between accelerated diffusion and apparent diffusion coefficient were obtained regardless of concrete age. The linear relations were also observed in strength-accelerated diffusion coefficient and strength-apparent diffusion coefficient regardless of concrete age.

An Experimental Study on the Estimation of Chloride Diffusion Coefficient of LNG Storage Tanks (LNG 저장탱크 염해 확산 계수 산출을 위한 실험적 고찰)

  • Lee, Seung-Rim;Hwang, Seung-Hyun
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.119-123
    • /
    • 2012
  • Although LNG storage tanks are very delicate with chloride attack owing to its operating inshore location, specific integrity management system for chloride attack has not been studied so far. As the design warranty life time, about 25 years, has come, to prevent paying huge amount of construction cost and required resources for new alternative storage tanks and manage the life time of operating storage tanks, the basic data of chloride attack is necessary. This study intended to build up basic data for following detailed study to develop technologies for life time management of LNG storage tanks, NT Build 492 method in North Europe was used to test chloride diffusion coefficient for the newly-constructing concrete outer tank. Results of these tests lead us to the conclusion that 90 days diffusion coefficients show 46% of 28 days' due to a large quantity of fly ash mixing and much similar to estimation from concrete process table. It seems resonable to conclude that 90 days specimens are recommended estimating the chloride diffusion coefficient for LNG storage tanks to enhance the reliabilities.

Crack and Time Effect on Chloride Diffusion Coefficient in Nuclear Power Plant Concrete with 1 Year Curing Period (1년 양생된 고강도 원전 콘크리트의 염화물 확산에 대한 균열 및 시간효과)

  • Chun, Ju-Hyun;Ryu, Hwa-Sung;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.83-90
    • /
    • 2017
  • Concrete structure for nuclear power plant is mass concrete structure with large wall depth and easily permits cracking in early age due to hydration heat and drying shrinkage. It always needs cooling water so that usually located near to sea shore. The crack on concrete surface permits rapid chloride intrusion and also causes more rapid corrosion in the steel. In the study, the effect of age and crack width on chloride diffusion is evaluated for the concrete for nuclear power plant with 6000 psi strength. For the work, various crack widths with 0.0~1.4 mm are induced and accelerated diffusion test is performed for concrete with 56 days, 180days, and 365 days. With increasing crack width over 1.0mm, diffusion coefficient is enlarged to 2.7~3.1 times and significant reduction of diffusion is evaluated due to age effect. Furthermore, apparent diffusion coefficient and surface chloride content are evaluated for the concrete with various crack width exposed to atmospheric zone with salt spraying at the age of 180 days. The results are also analyzed with those from accelerated diffusion test.