DOI QR코드

DOI QR Code

Experimental Study on the Relationship between Time-Dependent Chloride Diffusion Coefficient and Compressive Strength

시간의존성 염화물 확산계수와 압축강도 상관성에 대한 실험적 연구

  • 이승훈 (삼성물산(주)건설부문 기술연구소) ;
  • 권성준 (한남대학교 건설시스템공학과)
  • Received : 2012.07.04
  • Accepted : 2012.11.12
  • Published : 2012.12.31

Abstract

Since strength and diffusion coefficient of concrete, representative concrete properties that in change with age, the time effect must be considered in the analysis of chloride penetration. In this study, an evaluation of correlation between accelerated diffusion coefficient, apparent diffusion coefficient, and compressive strength in high performance concrete with various mineral admixtures such as ground granulated blast furnace slag, fly ash, and silica fume was performed. For this work, thirty mix proportions were prepared. Accelerated diffusion coefficients at the age of 28, 91, 180, and 270 days were evaluated. For apparent diffusion coefficient, submerging test for 6 months was performed. For evaluation of compressive strength with ages, the compressive strength test was carried out at an age of 7, 28, 91, 180 days. The results of accelerated diffusion coefficient, apparent diffusion coefficient, and strength were compared, and the correlation was analyzed considering time dependency. From this study, linear relationship between accelerated diffusion and apparent diffusion coefficient were obtained regardless of concrete age. The linear relations were also observed in strength-accelerated diffusion coefficient and strength-apparent diffusion coefficient regardless of concrete age.

콘크리트의 대표적 물성치인 강도 및 염화물 확산계수는 재령에 따라 변화하며, 염화물 침투 해석시 이러한 영향들이 고려되고 있다. 이 연구는 다양한 혼화재료 (고로슬래그 미분말, 플라이애쉬, 실리카 퓸)을 포함하는 고성능콘크리트의 촉진염화물 확산계수, 겉보기 염화물 확산계수, 강도 특성을 재령에 따라 실험적으로 도출하고 그 상관성을 분석하는데 목적이 있다. 이를 위해 30개의 배합을 가지는 고성능 콘크리트가 제작되었고, 재령 28일, 91일, 180일, 270일에 대한 촉진확산계수를 실험적으로 도출하였으며, 또한 동일배합에 대하여 침지 6개월 이후의 겉보기 확산계수가 도출되었다. 재령에 대한 강도 특성을 평가하기 위해, 재령 7일, 28일, 91일, 180일에 대한 강도시험이 수행되었다. 시간 의존적인 촉진확산계수의 변화가 겉보기 확산계수 및 강도와 비교되었으며, 각각의 상관관계가 재령에 대하여 분석되었다. 이 연구를 통하여 겉보기 확산계수와 촉진확산계수는 재령에 큰 영향을 받지 않으면서 선형적인 상관성이 도출되었다. 또한 강도와 촉진확산계수 그리고 강도와 겉보기 확산계수에서도 재령에 큰 영향을 받지 않는 선형적인 관계가 도출되었다.

Keywords

References

  1. Broomfield, J. P., Corrosion of Steel in Concrete: Understanding, Investigation and Repair. London: E&FN, 1997, pp. 1-15.
  2. Song, H. W., Pack, S. W., Lee, C. H., and Kwon, S. J., "Service Life Prediction of Concrete Structures under Marine Environment Considering Coupled Deterioration," Journal of Restoration of Building and Monument, Vol. 12, No. 1, 2006, pp. 265-284.
  3. RILEM, "Durability Design of Concrete Structures," Report of RILEM Technical Committee 130-CSL, E&FN, 1994, pp. 28-52.
  4. JSCE-Concrete committee, Standard Specification for Concrete Structures, 109, 2003, pp. 28-52.
  5. MLTM, Standard Concrete Specification-Durability, Korea Concrete Institute, 2004, pp. 18-26.
  6. Maekawa, K., Ishida, T., and Kishi, T., "Multi-Scale Modeling of Concrete Performance," Journal of Advanced Concrete Technology, Vol. 1, No. 2, 2003, pp. 91-126. https://doi.org/10.3151/jact.1.91
  7. Maekawa, K., Ishida, T., and Kishi, T., Multi-Scale Modeling of Structural Concrete, Tylor & Francis, London and Newyork. 1st Ed., 2009, pp. 291-352.
  8. Song, H. W., Kwon, S. J., Byun, K. J., and Park, C. K., "A Study on Analytical Technique of Chloride Diffusion Considering Characteristics of Mixture Design for High Performance Concrete Using Mineral Admixture," Journal of the Korean Society of Civil Engineers, Vol. 25, No. 1A, 2005, pp. 213-223.
  9. Thomas, M. D. A. and Bentz, E. C., Computer Program for Predicting the Service Life and Life-Cycle Costs of Reinforced Concrete Exposed to Chlorides, Life365 Manual, SFA, 2002, pp. 12-56.
  10. Thomas, M. D. A. and Bamforth, P. B., "Modeling Chloride Diffusion in Concrete: Effect of Fly Ash and Slag," Cement and Concrete Research, Vol. 29, No. 4, 1999, pp. 487-495. (doi: http://dx.doi.org/10.1016/S0008-8846(98)00192-6)
  11. CEB-FIP Model Code for Service Life Design, The International Federation for Structural Concrete (fib), Task Group 5.6, 2006, pp. 16-33.
  12. Kwon, S.-J., Na, U. J., Park, S.-S., and Jung, S. H., "Service Life Prediction of Concrete Wharves with Early-Aged Crack: Probabilistic Approach for Chloride Diffusion," Structural Safety, Vol. 31, No. 1, 2009, pp. 75-83. (doi: http://dx.doi.org/10.1016/j.strusafe.2008.03.004)
  13. Lee, H. S. and Kwon, S. J., "Technique for Chloride Behavior Using Apparent Diffusion Coefficient of Chloride Ion from Neural Network Algorithm," Journal of the Korea Concrete Institute, Vol. 24, No. 4, 2012, pp. 481-490. (doi: http://dx.doi.org/10.4334/JKCI.2012.24.4.481)
  14. Tang, L., "Electrically Accelerated Methods for Determining Chloride Diffusivity in Concrete-Current Development," Magazine of Concrete Research, Vol. 48, No. 176, 1996, pp. 173-179. https://doi.org/10.1680/macr.1996.48.176.173
  15. NORDTEST Chloride Migration Coefficient from Non- Steady-State Migration Experiments, NT BUILD 492, 1999, pp. 1-11.
  16. Kwon, S. J., Song, H. W., Byun, K. J., and Park, C. K., "Analysis of Chloride Penetration in Concrete with Mineral Admixtures Using Neural Network Algorithm and Micro Modeling," Journal of the Korean Society of Civil Engineers, Vol. 27, No. 1A, 2007, pp. 117-129.
  17. Ary, C., Buenfeld, N. R., and Newmann, J. B., "Factors Influencing Chloride Binding in Concrete," Cement and Concrete Research, Vol. 20, No. 2, 1990, pp. 291-300. (doi: http://dx.doi.org/10.1016/0008-8846(90)90083-A)
  18. Tang, L., Chloride Transport in Concrete, Publication P-96:6. Division of Building Materials, Chalmers University of Technology, Sweden, 1996, pp. 26-85.
  19. Nordtest Method, NT BUILD 443, Concrete, Hardened: Accelerated Chloride Penetration, UDC 622. 43, Approved 1995, 11 pp.
  20. Korea Expressway Corporation, "Characteristics Study with Cement Type for Concrete Durability Improvement of RC," Technical Report, 1999, pp. 129-133.
  21. Song, H.-W., Jang, J.-C., Saraswathy, V., and Byun, K. J., "An Estimation of the Diffusivity of Silica Fume Concrete," Building and Environment, Vol. 42, No. 3, 2007, pp. 1358-1367. (doi: http://dx.doi.org/10.1016/j.buildenv.2005.11.019)
  22. Khedr, S. A. and Zaid, M. N., "Characteristics of Silica- Fume Concrete," Journal of Materials in Civil Engineering, Vol. 6, No. 3, 1994, pp. 357-375. https://doi.org/10.1061/(ASCE)0899-1561(1994)6:3(357)
  23. Polder, R. B., Wegen, G. V., and Boutz, M., "Performance Based Guideline for Service Life Design of Concrete for Civil Engineering Structures-A Proposal Discussed in the Netherlands," International RILEM Workshop on Performance Based Evaluation and Indicators for Concrete Durability, Madrid, Spain., March 2006, pp. 19-21.
  24. Lee, C. Y., Kim, H. S., Kim, J. C., Cheong, H. M., and Ahn, T. S., "Comparison of Test Methods for Evaluation of Chloride Diffusion Coefficient in Concrete," Proceedings of the Korea Concrete Institute, Vol. 20, No. 1, 2008, pp. 581-584.
  25. Leem., Y. M., Yang, E. I., and Min, S. H., "Comparison of Diffusion Characteristics of Chloride According to the Condition of Hardened Concrete," Journal of the Korean Society of Safety, Vol. 19, No. 3, 2004, pp. 89-94.
  26. Yoon, C. S., Kim, K. H., Yang, W. Y., and Cha, S. W., "Chloride Diffusion Coefficient at Reference Time for High Performance Concrete for Bridge Pylons in Marine Environment," Journal of the Korea Concrete Institute, Vol. 24, No. 4, 2012, pp. 435-444. (doi: http://dx.doi.org/10.4334/ JKCI.2012.24.4.435)
  27. Polder, Rob B., Wegen, Gert van der, and Boutz, M., "Performance Based Guideline for Service Life Design of Concrete for Civil Engineering Structures-A Proposal Discussed in the Netherlands," International RILEM Workshop on Performance Based Evaluation and Indicators for Concrete Durability, Madrid, Spain, 2006.
  28. Al-Amoudi, O. S. B., Al-Kutti, W. A., Ahmad, S., and Maslehuddin, M., "Correlation between Compressive Strength and Certain Durability Indices of Plain and Blended Cement Concretes," Cement and Concrete Composites, Vol. 31, Issue 9, 2009, pp. 672-676. (doi: http://dx.doi.org/10.1016/j.cemconcomp.2009.05.005)
  29. Yoon, E. S., Lee, T. W., and Park, S. B., "Analysis of Correlation between Compressive Strength, Void Ratio and Chloride Diffusion Coefficient of Concrete Using Various Kinds of Cement," Journal of the Korea Concrete Institute, Vol. 17, No. 5, 2005, pp. 735-742. https://doi.org/10.4334/JKCI.2005.17.5.735

Cited by

  1. Evaluation on the Chloride Ion Diffusion Coefficient of Mortar Depending on Replacement Ratio of Recycled Fine Aggregate vol.16, pp.6, 2016, https://doi.org/10.5345/JKIBC.2016.16.6.479
  2. Service Life Evaluation through Probabilistic Method Considering Time-Dependent Chloride Behavior vol.28, pp.2, 2016, https://doi.org/10.4334/JKCI.2016.28.2.149
  3. Service Life Evaluation Considering Height of RC Structures and Distance from Sea Shore vol.4, pp.2, 2016, https://doi.org/10.14190/JRCR.2016.4.2.172
  4. Analysis for Effect of Diffusion Parameter with Time-dependent Diffusion Coefficient on Service Life Considering Deterministic and Probabilistic Method vol.4, pp.3, 2016, https://doi.org/10.14190/JRCR.2016.4.3.259
  5. Current Trends of Durability Design and Government Support in South Korea: Chloride Attack vol.9, pp.3, 2017, https://doi.org/10.3390/su9030417