Restoration of Chest X-ray Image Using Dual Projection Filter (이중 프로젝션 필터를 이용한 흉부 X-선 영상의 복원)

  • 이태수;민병구
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.25-32
    • /
    • 1992
  • A new restoration method of chest X -ray image (dual project filter) was proposed to improve SNR(signal to noise ratio) characteristics. In this method, a priori Information of system and anatomical structure and statistics of projected object are used in the design of filter. Dual projection filter varies its parameters, adapting to the local regions of chest(lung region, mediasternum, subdiaphragm) and the structure of chest (bone, tissue, blood vessel, bronchia). The performance of Dual Projection Filter was 0.1-0.2dB better than Dual Sensor Wiener Filter, which was used for initial estimate of Dual Porjection Filter.

  • PDF

Treatment of the Herniated Nucleus Pulposus Syndrome by Chemonucleolysis with Chymopapain

  • Dabezies, Eugene J.
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.111-120
    • /
    • 1984
  • A new restoration method of chest X-ray image (dual project filter) was proposed to improve SNR (signal to noise ratio) characteristics. In this method, a priori information of system and anatomical structure and statistics of projected object are used in the design of filter. Dual projection filter varies its parameters, adapting to the local regions of chest(lungregion, mediasternum, subdiaphragm) and the structure of chest (bone, tissue, blood vessel, bronchia). The performance of Dual Projection Filter was 0.1-0.2dB better than Dual Sensor Wiener Filter, which was used for initial estimate of Dual Porjection Filter.

  • PDF

The Relationship of Radiation Dose and Image Quality According to the Condition of Chest PA

  • Son, Jin-Hyun;Min, Jung-Whan;Kang, Byung-Sam;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.165-169
    • /
    • 2011
  • The purpose of this study is to compare the measurement result of radiation dose by using standard thoracic phantom and ionization chamber to advice proposal in the shooting condition of chest PA projection at hospitals recently. And to understand the change between radiation dose and resolution in different conditions. The period this study was from August 2010 to September 2010 and the subjects of the study was 3 general hospitals, 4 personal hospitals and 1 laboratory at the college. Finally we study with 6 DR, 1 CR, and 4 F/S equipments. Most hospitals met advice proposal, but some of the hospitals exceed advice dose from the result of our study. We can lower radiation dose about 25% when kVp is lowered about 20% in DR equipment. And we can lower radiation dose about 50% when mAs is lowered about 35%. The image quality was similar to the original in the study. Most hospitals which exceed advice dose were personal hospitals. The reason why it happened is that radiation dose for chest PA projection at personal hospitals is higher than general hospitals and the personal hospitals' equipments are older than general hospitals' equipments. We guess that patients' radiation dose of chest PA projection can be lowered from the result.

  • PDF

A Study on the Prevention of Healthcare Associated Infection in Chest PA Projection of Contact Infected Patients (접촉성 감염환자 흉부검사 시 의료관련감염 예방에 대한 연구)

  • Lee, Sang-Won;Kim, Dong-Jin;Lee, Bae-Won
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.297-304
    • /
    • 2018
  • This study proposes measures and methods to reduce healthcare associated infections by comparing and analyzing the bacterial contamination level before and after putting on personal protective equipment (PPE) on the test equipment and the contact infected patients getting chest PA projections. Among the 50 inpatients who were diagnosed with C. difficile, MRSA, and VRE, 28 patients who were instructed to undergo chest PA projection and follow-up were chosen, The 3 parts that come in contact with the detector, chin, chest, and hands, were designated for all, and the bacterial contamination level before and after disinfection and before and after putting PPE was determined. Statistical analysis was performed using Medcalc version 14, and quantitative analysis was performed using paired student t-test, with statistical significance being noted at p<0.05. Results for the comparison of the mean values before and after disinfection of the detector, chin (3.000), chest (2.000), and hands (3.430), showed that the number of bacteria after disinfection was lower than it was before disinfection. Analyzing for each part before and after disinfection, there were statistically significant differences for the chin, chest, and hands (p<0.01). Results for the comparison of the mean values before and after putting on PPE, chin (2.202), chest (2.140), and hands (4.213), showed that the number of bacteria after putting on PPE was lower than it was before putting on PPE. Analyzing for each part before and after putting on PPE, there were statistically significant differences for the chin, chest, and hands (p<0.03). As a result, it was confirmed that the number of bacteria after putting on PPE was lower than it was before putting it on. In the future, expanding the research scope for contact infected patients will establish standards for quarantine guidelines depending on the way it spreads, and contribute to the prevention of healthcare associated infections.

A Survey on Quality of Radiographs in Frontal Projection of the Chest (흉부(胸部) 정면(正面)X선사진(線寫眞)의 화질(畵質)에 관한 검사(檢討))

  • Choi, Jong-Hak;Jeon, Man-Jin;Lee, Chang-Yup
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.11-14
    • /
    • 1985
  • The author came to analize and get the following problems after researched radiographic quality in order to find out the necessary factors to improve in radiographs of frontal projection of the chest selected at random of the adult patients (1545 male, 1520 female) who had been examined in 4 departments of radiology of the general hospitals in Seoul and Kyungki area. 1. Problems of x-ray film or of radiographic cassette appeared in 2.97% radiographs on account of selection of the film size (except costophrenic sinus) (1.79%), poor screen-film contact (0.85%), light leakage of cassette (0,33%). 2. Problems of patients' positioning or breathing appeared in 16.57% radiographs of all because of overlapping of lung apex and clavicle (6.98%), overlapping of scapula and lung field (5.87%), asymmetrical projection of clavicles (1.76%), errors in positioning and breathing of the patient (1.96%). 3. Problems of x-ray exposure factors or film processing appeared in 22.25% radiographs because of over-density (2.64%), under-density (3.95%), fog (0.59%), demonstration density under clavicles or lung marking unsharply (3.82%), not clear of lung marking from breast region (0.94%), not clear the lung marking from the part overlapped of heart and lungs (3.92%), not clear the lung marking from the part overlapped of liver and lung (6.49%).

  • PDF

Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System (프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구)

  • Son, Junyoung;Choi, Sunghoon;Lee, Donghoon;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Chest digital tomosynthesis has become a practical imaging modality because it can solve the problem of anatomy overlapping in conventional chest radiography. However, because of both limited scan angle and finite-size detector, a portion of chest cannot be represented in some or all of the projection. These bring a discontinuity in intensity across the field of view boundaries in the reconstructed slices, which we refer to as the truncation artifacts. The purpose of this study was to reduce truncation artifacts using a weighted normalization approach and to investigate the performance of this approach for our prototype chest digital tomosynthesis system. The system source-to-image distance was 1100 mm, and the center of rotation of X-ray source was located on 100 mm above the detector surface. After obtaining 41 projection views with ${\pm}20^{\circ}$ degrees, tomosynthesis slices were reconstructed with the filtered back projection algorithm. For quantitative evaluation, peak signal to noise ratio and structure similarity index values were evaluated after reconstructing reference image using simulation, and mean value of specific direction values was evaluated using real data. Simulation results showed that the peak signal to noise ratio and structure similarity index was improved respectively. In the case of the experimental results showed that the effect of artifact in the mean value of specific direction of the reconstructed image was reduced. In conclusion, the weighted normalization method improves the quality of image by reducing truncation artifacts. These results suggested that weighted normalization method could improve the image quality of chest digital tomosynthesis.

A Prospective Analysis of Dynamic Loss of Breast Projection in Tissue Expander-Implant Reconstruction

  • Mioton, Lauren M.;Jordan, Sumanas W.;Kim, John Y.S.
    • Archives of Plastic Surgery
    • /
    • v.42 no.3
    • /
    • pp.309-315
    • /
    • 2015
  • Background Breast projection is a critical element of breast reconstruction aesthetics, but little has been published regarding breast projection as the firm expander is changed to a softer implant. Quantitative data representing this loss in projection may enhance patient education and improve our management of patient expectations. Methods Female patients who were undergoing immediate tissue-expander breast reconstruction with the senior author were enrolled in this prospective study. Three-dimensional camera software was used for all patient photographs and data analysis. Projection was calculated as the distance between the chest wall and the point of maximal projection of the breast form. Values were calculated for final tissue expander expansion and at varying intervals 3, 6, and 12 months after implant placement. Results Fourteen breasts from 12 patients were included in the final analysis. Twelve of the 14 breasts had a loss of projection at three months following the implant placement or beyond. The percentage of projection lost in these 12 breasts ranged from 6.30% to 43.4%, with an average loss of projection of 21.05%. Conclusions This study is the first prospective quantitative analysis of temporal changes in breast projection after expander-implant reconstruction. By prospectively capturing projection data with three-dimensional photographic software, we reveal a loss of projection in this population by three months post-implant exchange. These findings will not only aid in managing patient expectations, but our methodology provides a foundation for future objective studies of the breast form.

A Statistical Observation on Chest Radiography of Infants and Early Children (유유아(乳幼兒)의 흉부X선검사(胸部X線檢査)에 대(對)한 통계학적(統計學的) 고찰(考察))

  • Choi, Jong-Hak;Jeon, Man-Jin;Kim, Yong-Ill
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.45-50
    • /
    • 1979
  • For this study, 2,712 sheets of the chest x-ray films of neonatuses, infants and early children were observed statistically and then the following results were obtained: 1. Seasonal increment of patients was overwhelming in spring and summer in compare with in autumn and winter. 2. Males was majority in distribution by sex. Neonatal and infancy group was the largest in number by forming 29.46% in distribution by age group and then follows six-years group(14.75%), one-year group(13.64%) and five-years group(12.61%) 3. In radiographical projection for chest, a great proportion was P-A projection as 53.72%. But, almost all the neonatal and infancy group and emergency patients were by A-P projection 4. As for x-ray findings, 78.47% was normality while 21.53% was abnormality. Tuberculosis(176 cases), was the largest in number in abnormal cases and next in rank was pneumonia(128 cases)and then congenital heart disease(82 cases). 5. Adequacy of exposure was disclosed as follows: 57.01% in correct-exposure 29.20% in over-exposure, 13.79% in under-exposure. 6. The x-ray beam was not restricted in 77.10% of total films. 7. "Good" formed 30.01% in position immobilizing of the patient and "ordinary" formed 38.02%, "bad" 31.97%. Especially, "Bad" formed high percentage in neonatal and infancy group.

  • PDF

A Study on the Chest Radiographic Condition in Adult. (흉부X-선(胸部X-線) 촬영조건(撮影條件)에 대(對)한 고찰(考察))

  • Lee, Sang-Suk;Youn, Chul-Ho;Joo, Kuang-Tai;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.2 no.1
    • /
    • pp.31-35
    • /
    • 1979
  • A thorax is consisted of a heart, great vesseles, lungs, ribs, sternum and thoracic spine etc. The quality of chest radiogram is very important in order to find out abnormality in the lung field. The image has two major characteristics; density and contrast which directly influence the diagnostic quality of the roentgenogram. It is very hard to make excellent film image in the lung field because of overlapping bones and other soft tissues. To take a good radiogram of lung field, we studied the condition of chest P-A projection in adult and obtained results as follows: 1. The average chest radiographic condition is resulted as 62KVP, 16 mAs in hospitals around Kyung Ki-Do, Korea, 2. The density of the chest 20cm in thickness, is equal to the water phantom 8cm in thickness. 3. The best quality of chest radiogram is achieved in the condition of the lung field at 100KVP, 9.6mAs by use of Grid 8:1.

  • PDF

RVOT Obstruction Caused by Projection of The Herniated Aortic Cusp Through Subpulmonic VSD (심실중격결손증에 속발한 대동맥판탈출에 의한 우심실유출로 협착 [1례 보고])

  • 이병우
    • Journal of Chest Surgery
    • /
    • v.14 no.3
    • /
    • pp.254-259
    • /
    • 1981
  • This is a case of successfully surgically treated RVOT obstruction caused by projection of the herniated aortic cusp through subpulmonic supracristal VSD at Department of Thoracic and Cardiovascular Sugery, Hanyang University Hospital. The patient was a 17 year old boy. Congenital heart anomaly was suspected at 2 years of his age. He had palpitation, dyspnea on exertion and epistaxis for 2 years prior to admission to our hospital. On examination, the blood pressure was 170/0mmHg. And the pulse rate was 100/rain. Widening of pulse pressure, water hammer pulse [bounding pulse]. To and fro murmur and head nodding were noted. Cardiomegaly was seen in chest x-ray. EKG, Echocardiography, Cardiac catheterization and angiocardiography were performed. On April 27, 81. Open heart surgery was performed under the impression of VSD combined with AI. On Rt. ventriculotomy, we noticed RVOT obstruction caused by prolapsed rt coronary cusp through a VSD. The subpulmonic supracristal VSD measuring 2.5 x 3 Cm in diameter was closed with Teflon patch graft and then the prolapsed aortic leaflet was plicated by placing three 8-figure suture between the free edge and the base of the leaflet through transverse aortotomy. After operation, excellent result was obtained: B.P, was 110/50mmHg and any sign of AI or residual shunt was not found at discharge.

  • PDF