• 제목/요약/키워드: Chest X-ray image

검색결과 163건 처리시간 0.028초

Missed Skeletal Trauma Detected by Whole Body Bone Scan in Patients with Traumatic Brain Injury

  • Seo, Yongsik;Whang, Kum;Pyen, Jinsu;Choi, Jongwook;Kim, Joneyeon;Oh, Jiwoong
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권5호
    • /
    • pp.649-656
    • /
    • 2020
  • Objective : Unclear mental state is one of the major factors contributing to diagnostic failure of occult skeletal trauma in patients with traumatic brain injury (TBI). The aim of this study was to evaluate the overlooked co-occurring skeletal trauma through whole body bone scan (WBBS) in TBI. Methods : A retrospective study of 547 TBI patients admitted between 2015 and 2017 was performed to investigate their cooccurring skeletal injuries detected by WBBS. The patients were divided into three groups based on the timing of suspecting skeletal trauma confirmed : 1) before WBBS (pre-WBBS); 2) after the routine WBBS (post-WBBS) with good mental state and no initial musculoskeletal complaints; and 3) after the routine WBBS with poor mental state (poor MS). The skeletal trauma detected by WBBS was classified into six skeletal categories : spine, upper and lower extremities, pelvis, chest wall, and clavicles. The skeletal injuries identified by WBBS were confirmed to be simple contusion or fractures by other imaging modalities such as X-ray or computed tomography (CT) scans. Of the six categorizations of skeletal trauma detected as hot uptake lesions in WBBS, the lesions of spine, upper and lower extremities were further statistically analyzed to calculate the incidence rates of actual fractures (AF) and actual surgery (AS) cases over the total number of hot uptake lesions in WBBS. Results : Of 547 patients with TBI, 112 patients (20.4 %) were presented with TBI alone. Four hundred and thirty-five patients with TBI had co-occurring skeletal injuries confirmed by WBBS. The incidences were as follows : chest wall (27.4%), spine (22.9%), lower extremities (20.2%), upper extremities (13.5%), pelvis (9.4%), and clavicles (6.3%). It is notable that relatively larger number of positive hot uptakes were observed in the groups of post-WBBS and poor MS. The percentage of post-WBBS group over the total hot uptake lesions in upper and lower extremities, and spines were 51.0%, 43.8%, and 41.7%, respectively, while their percentages of AS were 2.73%, 1.1%, and 0%, respectively. The percentages of poor MS group in the upper and lower extremities, and spines were 10.4%, 17.4%, and 7.8%, respectively, while their percentages of AS were 26.7%, 14.2%, and 11.1%, respectively. There was a statistical difference in the percentage of AS between the groups of post-WBBS and poor MS (p=0.000). Conclusion : WBBS is a potential diagnostic tool in understanding the skeletal conditions of patients with head injuries which may be undetected during the initial assessment.

식도 이완 불능증과 간질성 폐렴을 동반한 전신성 홍반성 낭창 (Systemic Lupus Erythematosus Associated with Interstitial Pneumonia and Achalasia)

  • 권혜리;홍경욱;임승진;박소영;배영덕;김경호;최정희;모은경;박용범
    • Tuberculosis and Respiratory Diseases
    • /
    • 제65권4호
    • /
    • pp.323-327
    • /
    • 2008
  • 전신성 홍반성 낭창은 자가 면역 질환으로 폐와 흉막을 침범하며, 드물게 다양한 형태의 간질성 폐질환을 일으킨다. 식도 이완 불능증은 식도 운동 질환으로 전신성 홍반성 낭창과 동반한 예는 아주 드물다. 전신성 홍반성 낭창에 속발한 식도 이완 불능증의 기전에 대해서는 향후 연구가 필요할 것으로 사료된다. 전신성 홍반성 낭창에서 간질성 폐렴과 식도 이완 불능증을 동반한 환자를 경험하였기에 이를 보고하는 바이다.

PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가 (Evaluation for Optimization of CT Dose Reduction Methods in PET/CT)

  • 도용호;이홍재;김진의
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.55-62
    • /
    • 2015
  • PET/CT 검사 시 피폭 선량 감소를 위한 방법들이 지속적으로 개발되고 있다. 본 논문에서는 사용자에 의해 parameter 변경이 가능한 3가지 방법인 automatic exposure control(AEC), automated dose-optimized selection of X-ray tube voltage(CAREkV), sinogram affirmed iterative reconstruction(SAFIRE) 적용 시 각 방법의 적용 시와 3가지 방법의 조합에 따른 피폭선량 감소효과와 영상의 질 그리고 SUV 변화 유무를 평가하였다. Bograph mCT64 (Siemens, Germany)장비를 사용하여 anthropomorphic head, chest, pelvis phantom을 torso 모형으로 접합하여 스캔하였다. 120 kV, 40 mAs 조건으로 AEC의 적용 유무와 120 kV, 40 mAs AEC 조건으로 CAREkV의 적용 유무에 따른 피폭 선량 감소 효과를 평가 하였다. 120 kV, 25 mAs SAFIRE 조건에서 영상을 획득하여 120 kV, 40 mAs SAFIRE 미적용 시 대비 노이즈와 피폭선량 감소효과가 평가되었다. 120 kV, 40 mAs AEC 적용, 120 kV, 25 mAs 3가지 방법의 조합 조건으로 AAPM perfomance, anthropomorphic, IEC body phantom을 스캔하여 노이즈, 공간 분해능, 피폭선량 감소효과 그리고 PET SUV의 변화 유무를 평가하였다. AEC 적용 시, 미적용 대비 CTDIvol 50.52%, DLP 50.62% 감소하였다. CAREkV 적용 시 100 kV가 적용됨에 따라 mAs가 61.5% 증가하였으나 CTDI 6.2%, DLP 5.5% 감소하였다. Reference mAs를 낮게 지정할수록, strength값을 높게 지정할수록 피폭선량 감소 효과는 증가하였다. SAFIRE의 경우 40 mAs에서 25 mAs로 tube current를 37.5% 감소시켰음에도 불구하고 mean SD 2.2%, DLP 38% 감소하였다. AAPM phantom에서는 3가지 방법의 조합 시 AEC 대비 SD는 5.17% 감소하였으며 공간 분해능의 경우 유의한 차이가 없었다. Torso phantom의 경우 3가지 조합에서 AEC 대비 mean SD 6.7% 증가, DLP 36.9% 감소하였으며 IEC phantom 실험에서 PET SUV는 통계적으로 유의한 차이가 없었다(P>0.05). 본 논문에서 CT선량 감소를 위한 각 방법들 모두 피폭 선량 감소 효과를 보였으며 3가지 방법의 조합을 통하여 화질 저하와 PET SUV 변화 없이 AEC만 적용 시 대비 36.9%의 선량감소 효과가 있는 것으로 나타났다. 선량 감소 방법들의 최적화를 통하여 환자 피폭선량 저감화를 위한 지속적인 노력이 필요하며 특히 방사선 감수성이 높은 소아 환자에 적극적으로 적용되어야 할 것으로 사료된다.

  • PDF

Lung Cancer Knowledge among Secondary School Male Teachers in Kudat, Sabah, Malaysia

  • Al-Naggar, Redhwan Ahmed;Kadir, Samiah Yasmin Abdul
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권1호
    • /
    • pp.103-109
    • /
    • 2013
  • Background: The objective of this study is to determine knowledge about lung cancer among secondary school male teachers in Kudat, Sabah, Malaysia. Materials and Methods: A cross-sectional study was conducted among three secondary schools located in Kudat district, Sabah, Malaysia during the period from June until September 2012. The protocol of this study was approved by ethics committee of Management and Science University, Malaysia. The aims were explained and a consent form was signed by each participant. Respondents were chosen randomly from each school with the help of the headmasters. Self-administrated questionnaires, covering socio-demographic characteristics and general knowledge of lung cancer, were distributed. Once all 150 respondents completed the questionnaire, they passed it to their head master for collecting and recording. All the data were analyzed using Statistical Package for the Social Sciences (SPSS) version 13. ANOVA and t-test were applied for univariate analysis; and multiple linear regression for multivariate analysis. Results: A total of 150 male secondary school teachers participated in this study. Their mean age was $35.6{\pm}6.5$ (SD); maximum 50 and minimum 23 years old. More than half of the participants were Malay and married (52%, 79%; respectively). Regarding the knowledge about lung cancer, 57.3% of the participants mentioned that only males are affected by lung cancer. Some 70.7% mentioned that lung cancer can be transmitted from one person to another. More than half (56.7%) reported that lung cancer is not the leading cause of death in Malaysian males. As for risk factors, the majority reported that family history of lung cancer is not involved. However, 91.3% were aware that cigarettes are the main risk factor of lung cancer and more than half (52%) believed that second-hand smoking is one of the risk factor of lung cancer. More than half (51.3%) were not aware that asbestos, ionizing radiation and other cancer causing substances are risk factors for lung cancer. Quitting smoking, avoiding second-hand smoking and avoiding unnecessary x-ray image of the chest (53.3%, 96.0%, 87.3%; respectively) are the main preventive measures mentioned by the participants. For the factors that influence the participants knowledge, univariate and multivariate analysis showed that only race was significant. Conclusions: Overall, the knowledge of school male teachers about lung cancer was low. However, few items were scored high: cigarettes are the main risk factor; avoiding second-hand smoking; and avoiding x-rays. Interventions to increase lung cancer awareness are needed to improve early detection behavior. Increase the price of pack of cigarettes to RM 20 and banning smoking in public places such as restaurants are highly recommended as primary preventive measures.

자동현상기 지능화에 필요한 연산처리 기법의 개발을 위한 방사선 필름의 영상 지수의 분석 (Analysis of Image Factors of X-ray Films: Study for the Intelligent Replenishment System of Automatic Film Processor)

  • 박성태;윤종현;박광보;오용호;이형진;인경환;김건중
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.35-39
    • /
    • 1998
  • We analyzed image factors to determine the characteristic factors that need for intelligent replenishment system of the auto film processor. We processed the serial 300 sheets of radiographic films of chest phantom without replenishment of developing and fixation replenisher. We took the digital data by using film digitizer which scaned the films and automatically summed up the pixel values of the films. We analyzed characteristic curves, average gradients and relative speeds of individual film using densitometer and step densitometry. We also evaluated the pH of developer, fixer, and washer fluid with digital pH meter. Fixer residual rate and washing effect were measured by densitometer using the reagent methods. There was no significant reduction of the digital density numbers of the serial films without replenishment of developer and fixer. The average gradients were gradually decreased by 0.02 and relative speeds were also gradually decreased by 6.96% relative to initial standard step-densitometric measurement. The pHs of developer and fixer were reflected the inactivation of each fluid. The fixer residual rates and washing effects after processing each 25 sheets of films were in the normal range. We suggest that the digital data are not reliable due to limitation of the hardware and software of the film digitizer. We conclude that average gradient and relative speed which mean the film's contrast and sensitivity respectively are reliable factors for determining the need for the replenishment of the auto film processor. We need more study of simpler equations and programming for more intelligent replenishment system of the auto film processor.

  • PDF

간접변환방식 DR장비에서 CsI:Tl과 Gd2O2S의 검출기 화질 평가 (Image Quality Evaluation of CsI:Tl and Gd2O2S Detectors in the Indirect-Conversion DR System)

  • 공창기;최남길;정묘영;송종남;김욱;한재복
    • 한국방사선학회논문지
    • /
    • 제11권1호
    • /
    • pp.27-35
    • /
    • 2017
  • 본 연구의 목적은 DR (digital radiography) 장비에서 팬텀을 이용하여 간접변환방식의 CsI:Tl 검출기와 $Gd_2O_2S$ 검출기를 중심으로 두께가 두꺼운 흉부 팬텀과 중간 두께의 대퇴부 팬텀, 그리고 피사체의 두께가 얇은 손 팬텀의 영상을 획득하고 SNR과 CNR을 분석하여 검출기의 특성을 알아보고자 하였다. 피사체 두께 변화에 따른 SNR과 CNR을 측정한 결과 중간 두께의 대퇴부 팬텀과 두께가 얇은 손 팬텀을 촬영 하였을 때 SNR과 CNR은 $Gd_2O_2S$ 검출기보다 CsI:Tl 검출기에서 높게 나타났음을 확인 할 수 있었다. 그러나 두께가 두꺼운 흉부 팬텀을 사용하였을 때는 $Gd_2O_2S$ 검출기의 SNR이 80~125 kVp 일 때와 CNR이 80~110 kVp 일 때 CsI:Tl 검출기 보다 값이 높게 나타났고, 저관전압에서 고관전압으로 갈수록 SNR과 CNR은 모두 증가하였다. 중간 두께의 대퇴부 팬텀에서 CsI:Tl 검출기의 SNR과 CNR은 40~50 kVp 일 때 증가하다 고관전압으로 갈수록 감소하는 것을 확인 할 수 있었고, $Gd_2O_2S$ 검출기의 SNR과 CNR은 40~60 kVp 일 때 증가하다 고관전압으로 갈수록 감소하는 것을 확인 할 수 있었다. 두께가 얇은 손 팬텀에서 CsI:Tl 검출기의 SNR과 CNR은 저관전압에서 감소하다가 고관전압으로 갈수록 증가하면서 100~110 kVp에서는 감소하였고, $Gd_2O_2S$ 검출기의 SNR과 CNR은 고관전압으로 갈수록 감소하는 것을 확인하였다. MTF는 0.5~3 lp/mm에서 CsI:Tl 검출기가 $Gd_2O_2S$ 검출기보다 6.02~90.90%로 높음 보여주고 있고, DQE는 0.5~3 lp/mm에서 CsI:Tl 검출기가 $Gd_2O_2S$ 검출기보다 66.67~233.33% 높음 보여주고 있다. 결론적으로 MTF와 DQE의 비교에서는 CsI:Tl 검출기가 $Gd_2O_2S$ 검출기보다 높게 나타났지만, 두꺼운 흉부팬텀에서 일정 관전압 구간에서는 저가의 $Gd_2O_2S$ 검출기가 고가의 CsI:Tl 검출기보다 SNR과 CNR이 높다는 것을 확인하였다. 흉부 X선 검사 시 CsI:Tl 검출기보다 $Gd_2O_2S$ 검출기를 사용하여 우수한 화질의 흉부영상을 구현함으로써 검사에 유용할 것으로 판단되어지며, 사용자 입장에서 검출기 형태를 결정 할 때 가격대비 성능을 고려 해볼 사항으로 판단된다.

자동노출제어장치를 적용한 흉부 측면 방사선검사 시 환자 위치 변화가 주변 장기의 선량에 미치는 영향 (Effects of Change in Patient Position on Radiation Dose to Surrounding Organs During Chest Lateral Radiography with Auto Exposure Control Mode)

  • 김승욱;임청환;주영철;유신영
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.903-909
    • /
    • 2023
  • 본 연구는 자동노출제어장치를 이용한 흉부 측방향 검사 시에 환자의 중심위치 변화가 주변 장기의 피폭선량과 화질에 미치는 영향을 탐구하는데 목적이 있다. 실험은 인체모형팬텀을 대상으로 하였다. 바늘침을 팬텀의 관상선 중심 하단부에 부착하였고, 납 자를 검출기 하단부에 부착하여, 50 cm 지점이 AEC 이온챔버의 중앙 하단부에 위치하도록 하였다. 조사조건은 125 kVp, 320 mA, 초점-영상검출기간 거리는 180 cm, 조사야 크기는 14×17 inch를 사용하였다. AEC 이온 챔버는 중앙-하단 1개만 사용했고, Sensitivity 'Middle', Density '0' 으로 설정하여, 중심 X선은 6번째 흉추를 향해 수직입사 하였다. AEC mode를 적용한 상태에서 바늘침과 납 자의 50 cm 지점이 일치되게 위치시킨 후 팬텀을 배 쪽으로 5 cm (F5), 등 쪽으로 5 cm (B5) 씩 이동시킨 후 ESD를 측정하여 선량 인자를 분석하였다. 환자 중심위치 변화에 따른 갑상선의 ESD는 Center의 경우 232.60±2.20 μGy, F5는 231.22±1.53 μGy, B5는 184.37±1.19 μGy로 나타났으며, 유방의 ESD는 Center의 경우 288.54±3.03 μGy, F5는 260.97±1.93 μGy, B5는 229.80±1.62 μGy, 폐 중심부의 ESD는 Center의 경우 337.02±3.25 μGy, F5는 336.09±2.29 μGy, B5는 261.76±1.68 μGy 로 나타났다. 선량 인자의 각 그룹 간 평균값의 차이를 비교한 결과 통계적으로 유의한 차이가 나타났으며(p<0.01), 각각 독립적인 그룹으로 나타났다. 연구의 결과, 환자 중심위치 변화에 따른 갑상선, 유방, 폐 중심부의 선량의 차이는 환자가 전방 5 cm 정도의 움직임에서는 유방(10%)를 제외한 장기에서는 큰 차이가 없었으나, 후방 5 cm 정도의 움직임에서는 각 부위에서 평균 23.7%의 선량 감소를 나타냈다. 또한, 환자 중심위치가 후방으로 이동 시 화질의 저하가 나타났다.

전자선 단층 촬영을 이용한 관상동맥 우회로 개존의 비침습적 평가 (Noninvasive Evaluation of Coronary Artery Bypass Graft Patency by Electron Beam Tomography)

  • 최규옥;김호석;조범구
    • Journal of Chest Surgery
    • /
    • 제32권8호
    • /
    • pp.693-701
    • /
    • 1999
  • 최근 혈관 질환의 진단을 위한 비침습적 영상이 발달하면서, 기존의 도자술은 중재적 치료에 국한되는 실 정이다. 그러나 관상동맥이나 우회로는 작은 직경, 심박동 움직임 등으로 도자술이 아직도 진단에 필수적이 며, 비침 응\ulcorner영상 진단의 마지막 도전 영역이다. 전자선 단층 촬영기는 높은 시간 해상능으로 심장 영상을 얻을 수 있다. 전자선 단층 촬영을 이용하여 모관상 동맥 협착이나 관상동맥 우회로 이식술 후 개존성의 평 가가 시도되고 있으며, 이중 관상동맥 우회로술 평가의 정확도는 매우 높아서 임상 적용이 가능하다. 저자와 다른 연구자의 경험에 의하면 복재 정맥은 넓은 직경, 비교적 짧고 직선적인 경로, 심박동에 덜 영 향 받음으로써 EBT조영술의 정확도가 높았다. 전향적 민감도와 특이도가 각각 92%, 97%를 보였다. 그러나 위양성과 위음성을 보인 두 예는 후향적으로 분석 할 때 경험 부족에 의한 초기의 판독 오류로 사료되어 복 재 정맥의 경우 후향적으로는 100%의 정확도를 보였다. 반면 내유동맥 이식혈관은 작은 내경과 주변의 수술 클립에 의한 인공산물로 개존성을 확인하기가 대체로 어려웠고, 역동적 검사를 병행하여 우회로내 혈류를 확인하는 것이 필요하다. 내유동맥의 경우 상대적으로 정확도가 낮아 민감도, 특이도가 각각 100%, 80%를 보였으며, 위양성을 보인 2예는 후향적으로도 개존을 확인할 수 없었다. 전자선 단층 촬영 혈관 조영술은 관상 동맥 우 막\ulcorner이식술 후의 우회 혈관 개존성의 평가, 특히 복재 정맥 우회로의 경우 매우 정확도가 높은 비침습적 검사로써, 임상 적용이 기대된다. 앞으로 촬영 기기와 영상 재구성 software의 발달로 정확도를 더욱 높일 수 있는 잠재성이 있다.

  • PDF

진성 적혈구증다증 환자에서 발현한 Erdheim-Chester Disease 1예 (A Case of Erdheim-Chester Disease Who Has Policythemia Vera)

  • 김지은;이현정;이진국;윤형규;송정섭
    • Tuberculosis and Respiratory Diseases
    • /
    • 제64권3호
    • /
    • pp.224-229
    • /
    • 2008
  • ECD는 포말 대식세포의 전신 침범으로 염증 반응을 일으키는 드문 질환으로 다양한 임상양상과 불량한 예후를 보이는 질환이다. 본 증례는 골 동통과 폐막 침범이 된 자에서 흉막 생검을 통한 확진으로 ECD가 진단된 경우이며 기저질환으로 진성 적혈구 증다증이 있는 자에서 발현한 예를 경험하였기에 이를 문헌고찰과 함께 보고하는 바이다.

컴퓨터 단층촬영의 조직간 밀도차이에 대한 노이즈 영향 (Effect of Noise on Density Differences of Tissue in Computed Tomography)

  • 양원석;손정민;천권수
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.403-407
    • /
    • 2018
  • 현재 우리나라의 암 사망률 중 가장 높은 암은 폐암이며 조기발견이 어려운 대표적인 암이다. 조기 발견을 위하여 저선량 흉부 CT를 활용하고 있으며 이는 일반 흉부 X선 사진에 비해 약 3배 정도 폐암 진단율이 높다. 그러나 저선량 흉부 CT는 영상 해상도가 크게 저하될 뿐 아니라 신호가 약해 잡음에 민감한 단점이 있다. 또한 공기로 채워져 있는 폐는 밀도가 낮은 장기로 잡음의 유무가 암의 조기 진단에 영향을 크게 줄 수 있다. 본 연구는 Visual C++을 이용하여 2.0밀도를 가진 큰 원 내부에 물의 밀도인 1.0을 값을 갖는 원을 설정하고 그 안에 각각 밀도가 다른 작은 5개의 원을 수학적 팬텀화하고 가우시안 노이즈를 1%, 2%, 3%, 4% 각각 발생시켜 밀도차에 의한 노이즈의 영향을 평균 값과 표준편차 값, 신호대잡음비(SNR)로 확인하였다. 1% 노이즈 발생 시 큰 원과 작은 원의 밀도차가 가장 큰 영역의 SNR은 4.669로 노이즈의 영향이 작게 나타났으며 밀도차가 가장 낮은 영역의 SNR은 1.183으로 노이즈의 영향이 크게 나타났다. 또한 음의 밀도차에서도 같은 결과 값을 얻었으며 양의 밀도와 음의 밀도 모두 큰 원과 작은 원의 밀도차이가 높은 경우에 SNR 값이 높은 것을 확인 할 수 있다. 화질 또한 밀도차가 크게 나타났을 때 확연하게 육안으로 확인할 수 있었으며 노이즈레벨이 증가하는 경우에는 SNR이 감소하여 잡음의 영향이 크게 나타났다. 이는 밀도차가 적은 장기 또는 암과의 밀도가 비슷한 영역의 장기는 노이즈 영향이 크게 나타날 것이며 노이즈의 발생 확률에 따른 밀도차이의 영향이 진단에 영향을 끼칠 것으로 사료된다.